• 제목/요약/키워드: Total Pressure

검색결과 3,991건 처리시간 0.029초

오가피(五加皮) EtOH Extract의 장기투여여(長期投與與)가 가토(家兎)의 혈청중총(血淸中總) Cholesterol치(値)에 미치는 영향(影響) (The Effects of Long-Term Administration of Acanthopanax EtOH Extract on the Serum Total Cholesterol Content in Normal and Cholesterol-Administered Rabbits)

  • 고석태;김성원;임동윤
    • Journal of Pharmaceutical Investigation
    • /
    • 제8권1호
    • /
    • pp.17-26
    • /
    • 1978
  • Effects of Acanthopanax EtOH Extract (AEE) on the serum total cholesterol content of normal and cholesterol administered rabbits were investigated as a series of studies on pharmacological action, especially blood pressure to Korean Acanthopanax. AEE was administered orally(100mg/kg/day) and subcutaneously (30mg/kg/day) in both normal and cholesterol administered rabbits for 36 days. In this experiment the results obtained by comparing with values of the corresponding control group were as follows; 1) In the normal rabbits, long-term administration of AEE for 36 days did not entirely influence the serum total cholesterol content measured at 12th, 24th and 36th day and also not affect the original blood pressure and changes of blood pressure to norepinephrine, angiotensin and acetylcholine recorded at 36th day. 2) In the cholesterol administered rabbits, hypercholesteremia was induced by oral administration of cholesterol(300mg/kg/day) with feed. The rise rate of serum total cholesterol content was not modified at 12th day, whereas significantly inhibited at 24th and 36th days after begining this examination in both groups orally and subcutaneously administered AEE. Original blood pressure was declined and depressor action of acetylcholine was weakened in only group admininstered orally AEE of cholesterol-fed groups. Changes of blood pressure to norepinephrine and angiotensin in these all cholesterol-fed groups, and to acetylcholine in subcutaneous group of these cholesterol-fed groups were not affected significantly by AEE.

  • PDF

커먼레일 시스템용 저압 유압회로의 성능특성에 관한 연구 (A Study on the Performance Characteristics of Low Pressure Hydraulic Circuit of Common Rail System)

  • 이춘태
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.51-57
    • /
    • 2014
  • High pressure common rail injection technology has revolutionized the diesel industry. Over the last decade it has allowed engine builders to run higher injection pressures as much as above 1,300bar in order to increase engine efficiency, while reducing emissions. This common rail system has low pressure circuit which is consist of low pressure pump, cascade overflow valve and flow metering unit. The low pressure pump's purpose is to feed fuel oil to the high pressure pump. The cascade overflow valve keeps pressure in front of the metering unit constant and provides lubrication for the high pressure pump. The metering unit, known as the MPROP or fuel pressure regulator, regulates the maximum flow rate delivers to the rail. In this paper, we have investigated the performance characteristics of each components and total low pressure circuit of common rail system.

터보펌프 인듀서의 유동특성에 관한 연구 (A Study on the Flow Characteristics of a Turbopump Inducer)

  • 구현철;홍순삼;차봉준;양수석
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.41-46
    • /
    • 2002
  • Flow field downstream of an inducer was measured to see the flow and performance characteristics of a turbopump inducer. A large axisymmetric collector instead of a volute casing was installed to obtain circumferentially uniform flow - without interaction of the inducer and the volute. A conventional 3-hole probe was used to measure the flow. At inducer exit axial component of absolute velocity decreased on hub region with decrease in flow rate. Tangential velocity component static pressure, and total pressure increased from hub to tip. Relative flow angle from tangential direction was a little higher than outlet blade angle at flow coefficient $\varphi$=0.087 and 0.073. Dynamic pressure was $53\%$ of the mean total pressure at inducer exit at $\varphi$=0.073.

  • PDF

터보펌프 인듀서의 출구 유동 및 성능 특성 (Characteristics of Exit Flow and Performance of a Turbopump Inducer)

  • 홍순삼;구현철;차봉준;김진한
    • 한국유체기계학회 논문집
    • /
    • 제6권4호
    • /
    • pp.38-44
    • /
    • 2003
  • Flow field downstream of an inducer was measured to see the flow and performance characteristics of a turbopump inducer. A large axisymmetric collector instead of a volute casing was installed to obtain circumferentially uniform flow - without interaction of the inducer and the volute. A conventional 3-hole probe was used to measure the flow. At inducer exit, axial component of absolute velocity decreased on hub region with decrease in flow rate. Tangential velocity component, static pressure, and total pressure increased from hub to tip. Relative flow angle from tangential direction was a little higher than outlet blade angle at flow coefficient ${\phi}=0.087$ and 0.073. Dynamic pressure was $53\%$ of the mean total pressure at inducer exit at ${\phi}=0.073$.

표고버섯의 급여가 SHR 흰쥐의 혈압 및 혈청 지질 수준에 미치는 영향 (Supplementary Effect of Lentinus Edodes on Serum and Hepatic Lipid Levels in Spontaneously Hypertensive Rat)

  • 이성현;박홍주;조소영;정현진
    • Journal of Nutrition and Health
    • /
    • 제37권7호
    • /
    • pp.509-514
    • /
    • 2004
  • This study was conducted to investigate the supplementary effects of Lentinus edodes on blood pressure and blood lipid levels in the Hypertensive Rat. We supplied 3 kinds of experimental diets (Control; CO, cap of Lentinus edodes; LC, and stipe of Lentinus edodes; LS) to spontaneously hypertensive rats (SHR) for 8 weeks. Diet intake, body weight, organ weights, and serum lipid levels were measured. There was no significant difference in diet intake, and body, liver and epididymal fat pad weights among experimental groups. The levels of systolic and diastolic blood pressure were significantly lower in LC and LS groups than CO group. The concentrations of serum total cholesterol were lower in LC and LS groups than CO group. These results suggested that Lentinus edodes decrease blood pressure levels and serum total cholesterol concentration in the spontaneously hypertensive rats. But these effects of Lentinus edodes didn't show any significant difference between animals fed cap and stipe of this mushroom.

초음속 회전익의 앞전 형상이 공력 성능에 미치는 효과에 대한 수치적 연구 (Numerical Study on The Effects of Blade Leading Edge Shape to the Performance of Supersonic Rotors)

  • 박기철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.149-155
    • /
    • 2001
  • Recently, it is required to design higher stage pressure ratio compressor while maintaining equal adiabatic efficiency. To increase the stage pressure ratio, blade rotational speed or diffusion factor should be increased. In the case of increasing rotational speed, relative speed of flow at blade leading edge is well supersonic. In supersonic blade, total pressure loss is mainly due to shock wave and blade leading edge thickness should be very thin to minimize the shock wave loss. As a result, the blade is like to be week in terms of mechanical strength and the manufacturing cost is very high because NC machining is necessary. It is also one of big hurdle to overcome to make small compressor. In this paper, the effects of blade leading edge to the performance of supersonic blade In terms of total pressure loss. The efficiency of already known method to make thin blade leading edge from the casted blade with rather thick leading edge thickness is also assessed.

  • PDF

가스터빈용 소형 원심압축기의 탈설계점 성능에 관한 실험연구 (Experimental Study on Off-Design Performance of a Small Centrifugal Compressor for Gas Turbine Applications)

  • 오종식;이헌석;오군섭
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.211-218
    • /
    • 2000
  • Off-design experimental performance was investigated for a small centrifugal compressor, whose impeller diameter is about 125mm, used in an industrial gas turbine. Test rig was designed and manufactured with a radial inflow turbine and a combustor to supply driving power to the compressor. Static pressure was measured on the casing of the impeller, vaneless diffuser, vaned diffuser and volute. Total pressure was obtained using specially fabricated rakes at the vaned diffuser throat and exit. Circumferential nonuniformity was found, near surge, in the Impeller, vaned diffuser and volute region. Spanwise nonuniform flow from the impeller affected the total pressure defects in the vaned diffuser region. Static pressure distortion in the circumferential direction in the volute was found near surge, where the minimum occurred near 140 degree position.

  • PDF

75톤급 액체로켓 엔진 터보펌프 터빈의 성능특성연구 (Investigation on the Performance Characteristics of the 75ton Class Turbopump Turbine)

  • 정은환;이항기;박편구;곽현덕;김진한
    • 한국추진공학회지
    • /
    • 제14권5호
    • /
    • pp.65-71
    • /
    • 2010
  • 75톤급 개방형 액체로켓용 터보펌프 터빈의 성능시험을 수행하였다. 넓은 압력비와 회전수 영역에서 터빈의 출력을 측정하였으며 이를 통해 터빈로터 전후의 유동특성을 파악하였다. 아울러, 터빈의 효율 변화 및 측정된 로터입구의 압력을 기 개발된 30톤급 터빈과 비교하였으며 이를 바탕으로 설계 의도에 부합되는 향상된 성능의 동익을 재설계하였다.

액체로켓엔진 공급시스템 모듈 개발 (Development of Supply System Module for Liquid Rocket Engine)

  • 김혜민;이상복;김완조;노태성
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.79-84
    • /
    • 2010
  • 액체로켓엔진 공급시스템을 구성하는 배관, 오리피스, 굽힘관, 벨로우즈, 밸브, 플랜지 등의 공급계 부품들에 대한 액체로켓엔진 공급시스템 모듈을 개발하였다. 이 모듈은 각 부품별로 Sizing이 가능하며 압력강하를 계산할 수 있다. 또한, 공급시스템이 구성되면 시스템 전체 부품 개수, 압력강하, 출구압력, 무게를 도출할 수 있다.

  • PDF

공기사이클 냉동시스템의 성능해석 (Performance Analysis of an Air-Cycle Refrigeration System)

  • 원성필
    • 설비공학논문집
    • /
    • 제24권9호
    • /
    • pp.671-678
    • /
    • 2012
  • The objective of this study is to analyze theoretically the performance of an open air-cycle refrigeration system in which environmental concerns increase. The pressure ratio of the external compressor and efficiencies of the components that compose of the system are selected as important parameters. As the pressure ratio of the external compressor increases, the pressure ratio of the ACM compressor is determined high, the refrigerating temperature and capacity increase, the COP decreases, and the total entropy production rate increases. The effect of heat exchanger effectiveness and turbine efficiency on the performance are greater than that of the ACM compressor efficiency. Also the performance of the air-cycle refrigeration system with two heat exchangers has been enhanced like high COP and low total entropy production rate, compared to the system with one heat exchanger.