• 제목/요약/키워드: Total Measuring Accuracy

Search Result 140, Processing Time 0.036 seconds

Planning and Dosimetric Study of Volumetric Modulated Arc Based Hypofractionated Stereotactic Radiotherapy for Acoustic Schwannoma - 6MV Flattening Filter Free Photon Beam

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Arun, Gandhi;Kathirvel, Murugesan;Subramanian, Sai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.5019-5024
    • /
    • 2015
  • Background: The purpose of this study was to assess the dosimetric and clinical feasibility of volumetric modulated arc based hypofractionated stereotactic radiotherapy (RapidArc) treatment for large acoustic schwannoma (AS >10cc). Materials and Methods: Ten AS patients were immobilized using BrainLab mask. They were subject to multimodality imaging (magnetic resonance and computed tomography) to contour target and organs at risk (brainstem and cochlea). Volumetric modulated arc therapy (VMAT) based stereotactic plans were optimized in Eclipse (V11) treatment planning system (TPS) using progressive resolution optimizer-III and final dose calculations were performed using analytical anisotropic algorithm with 1.5 mm grid resolution. All AS presented in this study were treated with VMAT based HSRT to a total dose of 25Gy in 5 fractions (5fractions/week). VMAT plan contains 2-4 non-coplanar arcs. Treatment planning was performed to achieve at least 99% of PTV volume (D99) receives 100% of prescription dose (25Gy), while dose to OAR's were kept below the tolerance limits. Dose-volume histograms (DVH) were analyzed to assess plan quality. Treatments were delivered using upgraded 6 MV un-flattened photon beam (FFF) from Clinac-iX machine. Extensive pretreatment quality assurance measurements were carried out to report on quality of delivery. Point dosimetry was performed using three different detectors, which includes CC13 ion-chamber, Exradin A14 ion-chamber and Exradin W1 plastic scintillator detector (PSD) which have measuring volume of $0.13cm^3$, $0.009cm^3$ and $0.002cm^3$ respectively. Results: Average PTV volume of AS was 11.3cc (${\pm}4.8$), and located in eloquent areas. VMAT plans provided complete PTV coverage with average conformity index of 1.06 (${\pm}0.05$). OAR's dose were kept below tolerance limit recommend by American Association of Physicist in Medicine task group-101(brainstem $V_{0.5cc}$ < 23Gy, cochlea maximum < 25Gy and Optic pathway <25Gy). PSD resulted in superior dosimetric accuracy compared with other two detectors (p=0.021 for PSD.

A study on enhanced D-InSAR technique Considering Spatial and Temporal Coherence (공간적·시간적 긴밀도를 고려한 개선된 D-InSAR 기법에 관한 연구)

  • Lee, Won Eung;Yoon, Hong Sik;Youm, Min Kyo;Kim, Han Bual
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.25 no.2
    • /
    • pp.67-74
    • /
    • 2017
  • The D-InSAR is a technique for precisely measuring the subsidence of subsidence using difference of two SAR images. In order to calculate the subsidence using D-InSAR, a high coherence between master image and the slave image is essential. Since the existing D-InSAR method calculates the displacement based on the total coherence, the accuracy of the subsidence is lowered when the coherence map contains mountains or bare-land. In order to solve this problem, in this study, a point having a temporal coherence and spatial coherence of 0.7 or more was extracted to form TIN, and the subsidence was calculated based on this TIN. In addition, we compared the existing D-InSAR technique with the new D-InSAR technique considering spatial and temporal coherence. As a result, the new D-InSAR technique showed smaller standard deviation, relative variance, variation coefficient and quadrature deviation than the existing D-InSAR technique. It is also easy to grasp the trend of the subsidence.

The Influence of Participation of Physical Activity in Adolescence and Senescence Adults on Affective Cognition (청년기·노년기 성인의 신체활동 참여가 정서인지에 미치는 영향)

  • Yoon, Byungtak;Ryu, Kwangmin;Kim, Jingu
    • Science of Emotion and Sensibility
    • /
    • v.20 no.4
    • /
    • pp.41-54
    • /
    • 2017
  • Physical activity has positive effects on cognitive functions by aging. However, it is rare to find research that have scientifically investigated the effects on the affective-cognitive function. Thus, this study aims to brain-scientifically research its effects of physical activity on the affective-cognitive function of adults in adolescence and senescence. As subjects of this study, a total of 60 males adults in D region were selected, and then equally divided into four groups of young exercise group(25~35y/o), young non-exercise group(26~35y/o), old exercise group(60~70y/o), and old non-exercise group(60~70y/o). As experiment tools, the EEG measuring equipment and International Affective Picture System(IAPS) were used. The experiment of this study used an affective-cognitive task where subjects pressed a button depending on emotional valence(positive, neutral, negative) shown in the pictures. During the task, EEG measured eight areas(Fp1, Fp2, Fz, C3, C4, Cz, T3, T4) out of brain areas in accordance with the international 10-20 electrode system, EEG was measured. For statistical analysis, a three-way ANOVA on $4(group){\times}3(stimulus){\times}8(area)$ was conducted. The results showed main effects of group in both reaction time and accuracy, and also in the latency of P3. And there was an interaction between group and stimulus the amplitude of P3. In conclusion, Physical activity has positive effects on the affective-cognitive function of people in adolescence and senescence.

Study on the Correlation between the Soil Properties and Albiflorin, Paeoniflorin Contents of Paeonia lactiflora Pall. (작약의 Albiflorin, Paeoniflorin 함량과 토양특성 간의 상관관계 연구)

  • Eo, Hyun Ji;Park, Youngki;Park, Gwang Hun;Kim, Ji-Ah;Kim, Da Som;Kang, Yeongyeong;Kim, Kiyoon;Jang, Jun Hyuk;Kim, Hyun-Jun
    • Korean Journal of Plant Resources
    • /
    • v.34 no.4
    • /
    • pp.384-394
    • /
    • 2021
  • The aim of this study was to investigate the correlation between soil properties and marker compounds contents of Paeonia lactiflora. The methods of determining marker compounds were validated by measuring the linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy and recovery using UPLC analysis. P. lactiflora contained albiflorin at 0.04 ± 0.00 ~ 2.79 ± 0.21%, paeoniflorin at 1.98 ± 0.14 ~ 6.67 ± 0.84%. The root dry weight (RDW) of P. lactiflora was 0.06 ± 0.02 ~ 1.27 ± 0.28 kg. The soil properties analysis such as soil pH, electric conductivity (EC), organic matter (OM), total nitrogen (TN), available phosphate (Avail. P2O5), exchangeable cation and cation exchange capacity (CEC) were performed following standard analysis manual. The results of correlation analysis between soil properties and growth characteristics, available P2O5 was positively coreelated with the RDW of P. lactiflora. On the other hand, the RDW of P. lactiflora showed significantly negative correlation with contents of albiflorin and paeoniflorin. The results of this study was might be help to provide useful information on the establish of standard cultivation by the investigate correlation analysis between growth characteristics and marker compound contents of P. lactiflora.

Analysis of the Correlation Between Kidney Function Indicators and Kidney Size According Age Groups in Ultrasonography (신장 초음파 검사에서 연령대에 따른 신장 기능 지표와 신장 크기 간의 상관관계 분석)

  • Go, Ryo-won;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.871-879
    • /
    • 2020
  • The purpose of this study was to analysis the correlation between kidneys function indicators and these size in ultrasonography. A total of 170 (male:86, female:84) patients of sex and age groups were examined by abdominal ultrasonography. The patients classified as those in their 20's, 30's, 40's, and over 50's. We measured the length, width, and cross-sectional height of the kidneys twice. At this time, the length of these were measured from the maximum upper to the maximum lower pole and the widest width in the same ultrasonography was measured to obtain the cross-sectional area. Other relevant indicators included body surface area, serum creatinine, glomerular filtration rate (GFR), MDRD (Modification of diet in renal disease) and C-G (Cockcroft-Gault). Significant comparisons of differences between relevant factors by age groups and sex were conducted with a one-way distribution analysis. Correlation analysis was also performed between relevant factors by using Pearson and Spearman correlation coefficient. It was defined as meaningful when the p-value was less than 0.05. As a result, the length, the width, and the cross-sectional area of kidneys were correlated with GFR, C-G, MDRD. Therefore, it is expected that the accuracy of diagnosis of kidneys disease will be increased if the relevant indicators are evaluated together rather than measuring only length of these in ultrasonography.

Development of Remote Measurement Method for Reinforcement Information in Construction Field Using 360 Degrees Camera (360도 카메라 기반 건설현장 철근 배근 정보 원격 계측 기법 개발)

  • Lee, Myung-Hun;Woo, Ukyong;Choi, Hajin;Kang, Su-min;Choi, Kyoung-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.157-166
    • /
    • 2022
  • Structural supervision on the construction site has been performed based on visual inspection, which is highly labor-intensive and subjective. In this study, the remote technique was developed to improve the efficiency of the measurements on rebar spacing using a 360° camera and reconstructed 3D models. The proposed method was verified by measuring the spacings in reinforced concrete structure, where the twelve locations in the construction site (265 m2) were scanned within 20 seconds per location and a total of 15 minutes was taken. SLAM, consisting of SIFT, RANSAC, and General framework graph optimization algorithms, produces RGB-based 3D and 3D point cloud models, respectively. The minimum resolution of the 3D point cloud was 0.1mm while that of the RGB-based 3D model was 10 mm. Based on the results from both 3D models, the measurement error was from 10.8% to 0.3% in the 3D point cloud and from 28.4% to 3.1% in the RGB-based 3D model. The results demonstrate that the proposed method has great potential for remote structural supervision with respect to its accuracy and objectivity.

A study on TOC monitoring and spatial distribution analysis using a spectrometer in rivers (하천에서의 분광측정기를 이용한 TOC 모니터링 및 공간분포 분석 연구)

  • Yoon, Soo Bin;Lee, Chang Hyun;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.815-822
    • /
    • 2023
  • Organic pollution is one of the most common forms of water contamination. Under the Water Quality Conservation Act, indicators for measuring organic substances include BOD, COD, and TOC. Analysis of BOD and COD is labor-intensive, and in the case of organic substances where biological decomposition is not feasible or toxic substances are present, the accuracy is often low. Therefore, the Ministry of Environment is shifting towards TOC-centric management. With advancements in sensor technology today, various parameters can be monitored using sensors. In this study, digital monitoring of river TOC using a spectrophotometer called Spectro::lyser V3 was conducted. Initially, experiments were carried out at the Andong River Experiment Center to assess the applicability of the measurement equipment. Subsequently, data collected at the confluence of the Nakdong River was analyzed for the spatial distribution of TOC using the Kriging technique. This research proposes the utilization of sensors for river TOC monitoring and spatial distribution analysis. Real-time monitoring of changes in river TOC concentration can serve as fundamental data for pollution monitoring and response. Sensor-based river monitoring offers advantages in terms of temporal resolution and real-time data acquisition. When various spatial information interpretation methods are applied, it is expected to contribute to diverse studies such as aquatic ecological health, river water source selection, and stratification analysis in the future.

Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging

  • Ji Young Choi;Jihye Yun;Subin Heo;Dong Wook Kim;Sang Hyun Choi;Jiyoung Yoon;Kyuwon Kim;Kee Wook Jung;Seung-Jae Myung
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1093-1101
    • /
    • 2023
  • Objective: Cine magnetic resonance imaging (MRI) has emerged as a noninvasive method to quantitatively assess bowel motility. However, its accuracy in measuring various degrees of small bowel motility has not been extensively evaluated. We aimed to draw a quantitative small bowel motility score from cine MRI and evaluate its performance in a population with varying degrees of small bowel motility. Materials and Methods: A total of 174 participants (28.5 ± 7.6 years; 135 males) underwent a 22-second-long cine MRI sequence (2-dimensional balanced turbo-field echo; 0.5 seconds per image) approximately 5 minutes after being intravenously administered 10 mg of scopolamine-N-butyl bromide to deliberately create diverse degrees of small bowel motility. In a manually segmented area of the small bowel, motility was automatically quantified using a nonrigid registration and calculated as a quantitative motility score. The mean value (MV) of motility grades visually assessed by two radiologists was used as a reference standard. The quantitative motility score's correlation (Spearman's ρ) with the reference standard and performance (area under the receiver operating characteristics curve [AUROC], sensitivity, and specificity) for diagnosing adynamic small bowel (MV of 1) were evaluated. Results: For the MV of the quantitative motility scores at grades 1, 1.5, 2, 2.5, and 3, the mean ± standard deviation values were 0.019 ± 0.003, 0.027 ± 0.010, 0.033 ± 0.008, 0.032 ± 0.009, and 0.043 ± 0.013, respectively. There was a significant positive correlation between the quantitative motility score and the MV (ρ = 0.531, P < 0.001). The AUROC value for diagnosing a MV of 1 (i.e., adynamic small bowel) was 0.953 (95% confidence interval, 0.923-0.984). Moreover, the optimal cutoff for the quantitative motility score was 0.024, with a sensitivity of 100% (15/15) and specificity of 89.9% (143/159). Conclusion: The quantitative motility score calculated from a cine MRI enables diagnosis of an adynamic small bowel, and potentially discerns various degrees of bowel motility.

Detection of Hepatic Lesion: Comparison of Free-Breathing and Respiratory-Triggered Diffusion-Weighted MR imaging on 1.5-T MR system (국소 간 병변의 발견: 1.5-T 자기공명영상에서의 자유호흡과 호흡유발 확산강조 영상의 비교)

  • Park, Hye-Young;Cho, Hyeon-Je;Kim, Eun-Mi;Hur, Gham;Kim, Yong-Hoon;Lee, Byung-Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.22-31
    • /
    • 2011
  • Purpose : To compare free-breathing and respiratory-triggered diffusion-weighted imaging on 1.5-T MR system in the detection of hepatic lesions. Materials and Methods: This single-institution study was approved by our institutional review board. Forty-seven patients (mean 57.9 year; M:F = 25:22) underwent hepatic MR imaging on 1.5-T MR system using both free-breathing and respiratory-triggered diffusion-weighted imaging (DWI) at a single examination. Two radiologists retrospectively reviewed respiratory-triggered and free-breathing sets (B50, B400, B800 diffusion weighted images and ADC map) in random order with a time interval of 2 weeks. Liver SNR and lesion-to-liver CNR of DWI were calculated measuring ROI. Results : Total of 62 lesions (53 benign, 9 malignant) that included 32 cysts, 13 hemangiomas, 7 hepatocellular carcinomas (HCCs), 5 eosinophilic infiltration, 2 metastases, 1 eosinophilic abscess, focal nodular hyperplasia, and pseudolipoma of Glisson's capsule were reviewed by two reviewers. Though not reaching statistical significance, the overall lesion sensitivities were increased in respiratory-triggered DWI [reviewer1: reviewer2, 47/62(75.81%):45/62(72.58%)] than free-breathing DWI [44/62(70.97%):41/62(66.13%)]. Especially for smaller than 1 cm hepatic lesions, sensitivity of respiratory-triggered DWI [24/30(80%):21/30(70%)] was superior to free-breathing DWI [17/30(56.7%):15/30(50%)]. The diagnostic accuracy measuring the area under the ROC curve (Az value) of free-breathing and respiratory-triggered DWI was not statistically different. Liver SNR and lesion-to-liver CNR of respiratory-triggered DWI ($87.6{\pm}41.4$, $41.2{\pm}62.5$) were higher than free-breathing DWI ($38.8:{\pm}13.6$, $24.8{\pm}36.8$) (p value < 0.001, respectively). Conclusion: Respiratory-triggered diffusion-weighted MR imaging seemed to be better than free-breathing diffusion-weighted MR imaging on 1.5-T MR system for the detection of smaller than 1 cm lesions by providing high SNR and CNR.

Social Network Analysis for the Effective Adoption of Recommender Systems (추천시스템의 효과적 도입을 위한 소셜네트워크 분석)

  • Park, Jong-Hak;Cho, Yoon-Ho
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.4
    • /
    • pp.305-316
    • /
    • 2011
  • Recommender system is the system which, by using automated information filtering technology, recommends products or services to the customers who are likely to be interested in. Those systems are widely used in many different Web retailers such as Amazon.com, Netfix.com, and CDNow.com. Various recommender systems have been developed. Among them, Collaborative Filtering (CF) has been known as the most successful and commonly used approach. CF identifies customers whose tastes are similar to those of a given customer, and recommends items those customers have liked in the past. Numerous CF algorithms have been developed to increase the performance of recommender systems. However, the relative performances of CF algorithms are known to be domain and data dependent. It is very time-consuming and expensive to implement and launce a CF recommender system, and also the system unsuited for the given domain provides customers with poor quality recommendations that make them easily annoyed. Therefore, predicting in advance whether the performance of CF recommender system is acceptable or not is practically important and needed. In this study, we propose a decision making guideline which helps decide whether CF is adoptable for a given application with certain transaction data characteristics. Several previous studies reported that sparsity, gray sheep, cold-start, coverage, and serendipity could affect the performance of CF, but the theoretical and empirical justification of such factors is lacking. Recently there are many studies paying attention to Social Network Analysis (SNA) as a method to analyze social relationships among people. SNA is a method to measure and visualize the linkage structure and status focusing on interaction among objects within communication group. CF analyzes the similarity among previous ratings or purchases of each customer, finds the relationships among the customers who have similarities, and then uses the relationships for recommendations. Thus CF can be modeled as a social network in which customers are nodes and purchase relationships between customers are links. Under the assumption that SNA could facilitate an exploration of the topological properties of the network structure that are implicit in transaction data for CF recommendations, we focus on density, clustering coefficient, and centralization which are ones of the most commonly used measures to capture topological properties of the social network structure. While network density, expressed as a proportion of the maximum possible number of links, captures the density of the whole network, the clustering coefficient captures the degree to which the overall network contains localized pockets of dense connectivity. Centralization reflects the extent to which connections are concentrated in a small number of nodes rather than distributed equally among all nodes. We explore how these SNA measures affect the performance of CF performance and how they interact to each other. Our experiments used sales transaction data from H department store, one of the well?known department stores in Korea. Total 396 data set were sampled to construct various types of social networks. The dependant variable measuring process consists of three steps; analysis of customer similarities, construction of a social network, and analysis of social network patterns. We used UCINET 6.0 for SNA. The experiments conducted the 3-way ANOVA which employs three SNA measures as dependant variables, and the recommendation accuracy measured by F1-measure as an independent variable. The experiments report that 1) each of three SNA measures affects the recommendation accuracy, 2) the density's effect to the performance overrides those of clustering coefficient and centralization (i.e., CF adoption is not a good decision if the density is low), and 3) however though the density is low, the performance of CF is comparatively good when the clustering coefficient is low. We expect that these experiment results help firms decide whether CF recommender system is adoptable for their business domain with certain transaction data characteristics.