• Title/Summary/Keyword: Total Heat Exchange Factor

Search Result 7, Processing Time 0.02 seconds

An Inverse Analysis on the Estimation of Two-dimensional Total Heat Exchange Factor on the Billet in the Reheating Furnace (가열로 내 소재의 2 차원 총괄열흡수율 추정에 관한 역해석)

  • Kwag, Dong-Seong;Kang, Deok-Hong;Kim, Ki-Hong;Kim, Woo-Seung
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.175-180
    • /
    • 2003
  • An inverse problem to determine two-dimensional total heat exchange factor is studied for the prediction of the billet temperature in the reheating furnace. Temperature measurements by the experiment are used in the inverse analysis. This inverse analysis employs the conjugate gradient method. The total heat exchange factors for 12-zones of the cross-section of the billet are estimated. The estimated temperatures at measurement locations are in good agreements with the measured temperatures.

  • PDF

Prediction of Billet Temperature by the Total Heat Exchange Factor on the Reheating Furnace (총괄열흡수율을 이용한 가열로내 소재(Billet) 온도예측)

  • Gang, Deok-Hong;Kim, Gi-Hong;Lee, Yong-Guk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.11
    • /
    • pp.1549-1554
    • /
    • 2000
  • A new method to determine the total heat exchange factor was proposed for the prediction of billet temperature in a reheating furnace. This method employed the squared of the difference between measured and predicted temperatures as an objective function. The real billet temperature in a walking beam type reheating furnace with 19.75m of its effective length was directly measured by thermocouples. The present method was validated by showing that the predicted billet temperature was in a good agreement with the measured one.

Performance Comparison of 7mm Fin-Tube Heat Exchangers for Various Design Conditions (설계 조건에 따른 7mm 직경 핀-관 열교환기의 성능비교)

  • Chang, Keun-Sun;Kim, Hyuk;Hong, Seok-Ryul;Kim, Young-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.633-638
    • /
    • 2006
  • This study presents the air side heat transfer and friction characteristics of fin-tube heat exchangers with various fin types. A total of 8 samples of heat exchangers are tested. Fin patterns tested are slit, louver and plate fins. Each fin type has three cases of number of tube rows(N=1, 2, 3) and two different fin pitches. The results are plotted in terms of Colburn j-factor and friction factor f with respect to Reynolds number in the range of 200 to 510.

  • PDF

An Inverse Analysis on the Estimation of Two-dimensional Overall Heat Absorptance on the Slab in the Reheating Furnace (가열로 내 소재의 2 차원 총괄열흡수율 추정에 관한 역해석)

  • Kang, Deok-Hong;Kwag, Dong-Seong;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.11 s.242
    • /
    • pp.1257-1264
    • /
    • 2005
  • An inverse problem to determine two-dimensional total heat exchange factor is studied for the prediction of the slab temperature in the reheating furnace. Temperature measurements by the experiment are used in the inverse analysis. This inverse analysis employs the conjugate gradient method. The overall heat absorptances for 12-zones of the cross-section of the slab are estimated. The estimated temperatures at measurement locations are in good agreements with the measured temperatures.

The Study on the Gas Temperature Set by Calculating the Sensitivity of Slab Temperature in Reheating Furnace (소재온도 감도계산을 통한 가열로내 분위기온도 설정방안 연구)

  • Gang, Deok-Hong;Kim, Gi-Hong;Lee, Yong-Guk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1030-1036
    • /
    • 2001
  • A new mathematical model to determine the optimal gas temperatures in reheating furnace was proposed for the good quality of products. This model employs sensitivity method to calculate the optimal gas temperatures in each zone for heating the slab up to its discharging target temperature and for heating it uniformly. This method was validated by showing that the calculated discharging temperature of the slab was in a good agreement with its prescribed discharging target one through an off-line simulation.

Analysis of Heating Load Characteristics for Greenhouses Constructed in Reclaimed Lands (간척지 설치 온실의 난방부하 특성 분석)

  • Nam, Sang Woon;Shin, Hyun Ho
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.6
    • /
    • pp.1-8
    • /
    • 2017
  • The purpose of this study was to provide basic data for development of environmental design technology for greenhouses constructed in reclaimed lands. We analyzed the climatic conditions around seven major reclaimed land areas in Korea, which have a plan to install advanced horticultural complexes. The characteristics of heating load through the thermal environment measurement of the greenhouse in Saemangeum were analyzed. The part to be applied to the environmental design of the greenhouses in reclaimed lands were reviewed. The overall heat transfer coefficient of the experimental greenhouse with the aluminum screen and multi-layer thermal curtain averaged $3.79W/m^2^{\circ}C$. It represents a 44 % heat savings rate compared with plastic greenhouses with a single covering, which was significantly lower than that of the common greenhouses with 2-layer thermal curtains. This is because the experimental greenhouse was installed on reclaimed land and wind was stronger than the inland area. Among the total heating load, the transmission heat loss accounted for 96.4~99.9 %, and the infiltration loss and the ground heat exchange were low. Therefore, it is necessary to take countermeasures to minimize the transmission heat loss for greenhouses constructed in reclaimed lands. As the reclaimed land is located on the seaside, the wind is stronger than the inland area, and the fog is frequent. Especially, Saemangeum area has 2.6 times stronger wind speed and 3.4 times longer fog duration than the inland area. In designing the heating systems for greenhouses in reclaimed lands, it is considered that the maximum heating load should be calculated by applying the wind coefficient larger than the inland area. It is reasonable to estimate the operation cost of the heating system by applying the adjustment factor 10 % larger than the average in calculating the seasonal heating load.

Characteristics of Vitrification Process for Mixture of Simulated Radioactive Waste Using Induction Cold Crucible Melter (유도가열식 저온용융로를 이용한 혼합모의 방사성폐기물의 유리화 공정 특성)

  • 김천우;양경화;박병철;박승철;황태원;박종길;신상운;하종현;송명재
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.165-174
    • /
    • 2004
  • In order to simultaneously vitrify the ion exchange resin(IER) and combustible dry active waste(DAW) generated from Korean nuclear power plants, a vitrification pilot test was conducted using an induction cold crucible melter(CCM) . The energy necessary for startup of the glass using a Ti-ring was evaluated as about 290 kWh. The power supplied from a high frequency generator to melt the glass properly was ranged from 160 to 190 kW without any interruption. When the mixture of the IER and DAW was fed into the CCM, the concentration of CO was lowered up to 1/40 compared to feeding the IER solely. It may be caused by the DAW which can produce about 1.8 times higher heat compared to the IER. When the swelling phenomenon occurred in the glass melt, the concentration of $NO_2$, oxidizing gas, was higher than NO, reducing gas. Total feed amounts of the IER and DAW were 368 and 751 kg, respectively. And then, about 74 of volume reduction factor was achieved.

  • PDF