• 제목/요약/키워드: Total Floor Area

검색결과 246건 처리시간 0.031초

상악동 거상술을 이용하여 구치부에 식립된 $Br{\aa}nemark$ Ti-Unite와 ITI SLA 임플란트의 임상적 평가 (Clinical evaluation of $Br{\aa}nemark$ Ti-Unite implant and ITI SLA implant in the post maxillary area with sinus elevation technique.)

  • 홍성배;채경준;정의원;김창성;심준성;최성호;조규성;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제35권4호
    • /
    • pp.813-822
    • /
    • 2005
  • The predictable outcome of implant placement in the atrophic maxilla with sinus floor elevation procedure(osteotome sinus floor elevation technique and window opening technique) is well documented. Aim of this study was to evaluate the efficacy of $Br{\aa}nemark$ Ti-Unite implant system and ITI SLA implant system placed in the atrophic posterior maxilla with sinus floor elevation procedure. Eighty patients received placement of $Br{\aa}nemark$ Ti-Unite implants(195 implants) in their atrophic posterior Maxilla with sinus floor elevation procedure(153 osteotome sinus floor elevation technique and 42 window opening procedure). Fifty patients received placement of ITI SLA implants(83 implants) in their atrophic posterior Maxilla with sinus floor elevation procedure(77 osteotome sinus floor elevation technique and 6 window opening procedure). Chart review were taken from each patient. The total failed implants were seven and the total implant survival rate was 96.4% in $Br{\aa}nemark$ Ti-Unite system. The total failed implants were one and the total implant survival rate was 98.8% in ITI SLA system. The implant survival rate with osteotome technique was 96% and 97.6% with window opening in $Br{\aa}nemark$ Ti-Unite system. The implant survival rate with osteotome technique was 98.7% and 100% with window opening. The implant survival rate with osteotome technique was 96% and 97.6% with window opening in ITI SLA system. The results of this evaluation show that the placement of $Br{\aa}nemark$ Ti-Unite system as well as ITI SLA system is a reasonable treatment option for patients with the atrophic posterior maxillary area.

Airtightness of Light-Frame Wood Houses built in Daejeon and Chungnam Area

  • Jang, Sang-sik;Ha, Been
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권2호
    • /
    • pp.147-158
    • /
    • 2017
  • Among the energy consumption in building, the heating energy takes the largest part. Therefore, it is important to minimize the heat energy loss in building for the reduction of overall energy use in construction. The most important points for the minimization of energy loss in building are insulation and airtightness. Especially, in wood houses, airtightness is very important for energy saving as well as increase of durability. However, the researches on airtightness of wood buildings have been started recently and are very deficient especially in Korea. In this study, air leakage properties and airtightness performance were evaluated for light-frame wood houses built in Daejeon and Chungnam area. Total 7 houses were evaluated, among which four houses (Case 1 to Case 4) were in the construction stage before interior finish and the other three houses (Case 5 to Case 7) were after completion of construction work. The tests for airtightness were conducted by pressurization-depressurization method, and the factors included in the measurements includes air leakage rate at 50 Pa (CMH50), air change rate at 50 Pa (ACH50), equivalent leakage area (EqLA) and EqLA per floor area. As a result of this study, key air leakage points in wood houses were found to be the gaps between floor and wall, the holes for wiring and plumbing, the double glasses windows and the entrance doors. The average value of ACH50 for the houses after completion of construction work was $3.5h^{-1}$ that was similar to Europe standard ($3.0h^{-1}$). ACH50 was proportional to EqLA per floor area but inversely proportional to the internal volume, the net floor area and the area of window.

중국연변지역 조선족 농촌주택의 시기별 변천에 대한 조사연구 - 평면의 변화를 중심으로 - (A Research on Periodical Changes of Rural Houses of Korean-Chinese People in Yanbian Area, China - Focused on changes of floor plans -)

  • 허성걸;조원석;변경화
    • 한국농촌건축학회논문집
    • /
    • 제17권3호
    • /
    • pp.1-9
    • /
    • 2015
  • The purpose of this paper is to analysis on periodical changes of rural houses of Korean-Chinese people residing in Yanbian area, China focused on periodical changes of floor plans according to Chinese government's policies and regulations influencing on rural houses. Changes of floor plans are classified into four periods; immigrating settled period, 1960-1970s, 1980-1990s, and after 2000. Total number of 67 cases were analyzed that data was collected 48 cases of literature studies and 19 cases of field study in Yanbian, China. The results are as followings. In immigrating settled period, floor plans of the rural houses have tended to be continued the pattern of the Korean traditional rural houses. Nevertheless China was changed socialism system, rarely floor plans were influenced by the system during this period. From 1960s to 1970s, the livestock and rural mechanization are influenced by the "People's Commune" policy. The "Barn" and "Mill" were converted into "warehouse". The residential part consists of one Jeongji (space mixed dinning and kitchen) and one to three of Ondolbang (room). From 1980s to 1990s influenced by the policies of "Cultural Revolution", "Birth Control" and "Chinese Economic Reform", the Korean traditional customs like "elders first" and "distinction between the male and female have been gradually vanished. Meanwhile, spaces of the rural houses have consisted of Jeongji, big Utppang (room), and warehouse. Each space is opened and mutual. Since 2000, influenced by the policy of a "new Socialist Countryside Construction", the bathroom and kitchen are added in interior spaces, the life style in rural houses has been changed as for both the sedentary style and western style.

역사적 도심 내 자가(自家) 병용주택의 현황 및 유형별 특성 - 청주시 성안동과 중앙동을 대상으로 - (Current Situation and Characteristics of Owner Shop Houses in the Historic Area - Focused on Seongan-dong and Jungang-dong, Cheongju, Korea -)

  • 유슬기;정진주;김태영
    • 한국농촌건축학회논문집
    • /
    • 제26권2호
    • /
    • pp.35-40
    • /
    • 2024
  • This study examines the classification and typical characteristics of 148 owner shop houses existing in the historical city center of Cheongju. First, they can be classified into single-story, middle-story, and divided types according to the distribution of residential and commercial functions. The single-story(36) has 'ㅡ', 'ㄱ', and 'narrow and deep'-shaped arrangement, with stores on the front and houses on the rear. The middle-story second floor(89) is divided into a first-story store and a second-story house, and the third floor(23) has different functions for each floor, but more than half of them have houses on the second and third floors. Among the total, there are also 16 cases in which the division type is taken with different construction times and structures. Second, in the position of the stairs connected to the upper floor among the middle-floor types(112), the outer stair type(52) to separate from the living space while making the most of the stores on the first floor accounts for 47%, but the biggest feature is that the inner staircase type(34) with privacy reaches 30%. The rear stair room type(26) entering through alleyways or private yards is also 23%. Third, the front pillar spacing varies from 1bay to 4bay in appearance, but the 2bay type on the 2nd floor and the 1bay type on the 3rd floor occupy the largest proportion. This exterior type is a characteristic of a owner shop house that can measure the range of personal ownership. Despite the conflicting functions of stores and houses, 35~40% of the cases are in which the opening positions of the upper and lower floors are unified.

Effect on the Center of Pressure of Vision, Floor Condition, and the Height of Center of Mass During Quiet Standing

  • Kim, Seung-su;Lim, Kitaek;Choi, Woochol Joseph
    • 한국전문물리치료학회지
    • /
    • 제28권2호
    • /
    • pp.154-160
    • /
    • 2021
  • Background: Theoretically, balance is affected by the height of center of mass (COM) during quiet standing. However, no one examined this in humans with variables derived from the center of pressure (COP). Objects: We have conducted balance experiment to measure COP data during quiet standing, in order to examine how the COP measures were affected by the height of COM, vision, floor conditions, and gender. Methods: Twenty individuals stood still with feet together and arms at sides for 30 seconds on a force plate. Trials were acquired with three COM heights: 1% increased or decreased, and not changed, with two vision conditions: eyes closed (EC) and eyes open (EO), and with two floor conditions: unstable (foam pad) and stable (force plate) floor. Outcome variables included the mean distance, root mean square distance, total excursion, mean velocity, and 95% confidence circle area. Results: All outcome variables were associated with the COM height (p < 0.0005), vision (p < 0.0005), and floor condition (p < 0.003). The mean velocity and 95% confidence circle area were 5.7% and 21.8% greater, respectively, in raised COM than in lowered COM (24.6 versus 23.2 mm/s; 1,013.4 versus 832.3 mm2). However, there were no interactions between the COM height and vision condition (p > 0.096), and between the COM height and floor condition (p > 0.183) for all outcome variables. Furthermore, there was no gender difference in all outcome variables (p > 0.186). Conclusion: Balance was affected by the change of COM height induced by a weight belt in human. However, the effect was not affected by vision or floor condition. Our results should inform the design of balance exercise program to improve the outcome of the balance training.

건축물 연면적에 따른 노상·노외 주차수요 산정 모형 구축 (Establishment of a Estimation Model of On-Road and Off-Road Parking Demand Based on the Total Floor Area of Buildings)

  • 남제모;이영우
    • 한국ITS학회 논문지
    • /
    • 제22권2호
    • /
    • pp.44-53
    • /
    • 2023
  • 최근 충분한 주차공간 확보의 어려움으로 심각한 주차문제가 발생하고 있으며 또 다른 교통문제나 사회문제로 이어지기도 한다. 일정 범위 이상의 지역·지구에서 발생하는 주차문제를 해결하기 위해서는 지역특성을 반영한 노상 및 노외주차장에 대한 연구가 필요하며 본 연구에서는 지역·지구의 특성을 고려한 노상 및 노외주차 공급 정책을 수립하는데 기초 연구로 활용하기 위한 주차수요 산정모형을 구축하였다. 연구수행을 위해 대구광역시 동구를 행정동으로 구분하여 주차시설, 주차수요를 조사하였다. 조사시간은 평일에 주간과 야간으로 구분하였으며 차종은 승용차 소형트럭·버스, 대형트럭·버스 3종으로 구분하였다. 주차수요 산정을 위한 설명변수로 단독주택, 공동주택, 근린생활시설, 문화·집회시설, 업무시설, 판매시설 등 6가지의 용도별 건축물 연면적을 사용하였다. 상관분석 결과 6가지 설명변수 중 근린생활시설의 연면적이 노상 및 노외 주차수요와 유의미한 상관관계를 나타내었다. 근린생활시설의 연면적을 설명변수로 하여 회귀분석 모형을 구축하였고 통계적으로 유의미한 결과를 얻었다.

항공레이저측량 자료를 이용한 시가지 건축밀도 평가에 관한 연구 (The Evaluation of Architectural Density on Urban District using Airborne Laser Scanning Data)

  • 이근상;고덕구;조기성
    • 한국지리정보학회지
    • /
    • 제6권3호
    • /
    • pp.95-106
    • /
    • 2003
  • 본 연구에서는 최근 도시계획, 수자원 및 방재 분야에서 높은 관심을 가지고 연구중인 항공레이저측량기법을 활용하여 시가지의 건축밀도를 평가하였다. 먼저, 레이저스캐너인 LiDAR(light detection and ranging)로 취득한 표고자료로부터 DEM(digital elevation model)과 DSM(digital surface model)을 구축하였으며, 건물의 높이를 계산하기 위해 DEM에는 ZONALMEAN 필터, DSM에는 ZONALMAJORITY 필터를 적용하였다. 필터링 과정으로부터 계산한 층수와 현지조사의 층수를 비교한 결과 표준오차 ${\pm}0.199$층을 확보할 수 있었다. 또한 건물 연면적 레이어와 구획 레이어를 중첩하여 통계분석함으로서 도시 구획별 용적률을 제시할 수 있었다. 항공레이저측량 자료를 이용하여 계산한 용적률과 현지조사로부터 계산한 용적률의 비교 결과, 용적률의 표준오차를 ${\pm}2.68%$로 확보할 수 있었다. 따라서, 항공레이저측량 자료는 향후 토지이용계획을 수립하는 의사결정자에게 매우 유용한 자료를 제공해 줄 것으로 기대한다.

  • PDF

고령화 사회에 따른 국민임대아파트 1층 공유공간의 계획방향에 대한 연구 (A study on Design Planning of the National Rental Apartment's Community Space Located on Ground Level Floor for Aging Society)

  • 채민석;이주현;이현수
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.71-79
    • /
    • 2008
  • Lower birth rate and higher elder people are serious social problem in Korea. In 2003, the total birth rate is 1.19 per person, that record is lowest among OECD country. In 2005, Korea has been the aging society with 9.0% in aged population rate. Increasing of aged population results in elder estrangement and confliction with other generations. The social problem can be solved in some degree by improving housing environment and many kinds of welfare program. This study suggests a solution of the problem by applying community space located on ground level floor. The ground level floor of apartment has many physical benefits like connection to the earth, extension, safeness for the aged and child. in case of the National Rental apartment, small residential area and high rate of elder, child, the disabled make the ground level floor useful space for community. According to case study, almost the National Rental apartment hasn't enough facilities supporting various generations and don't supply comfortable environment. So, this study presents how to design the National Rental Apartment's community space located on ground level floor.

신축공동주택의 기밀성능 실측에 관한 연구 (The Field Measurement of Airtightness in the Apartment Buildings)

  • 박원석;윤재옥
    • KIEAE Journal
    • /
    • 제3권3호
    • /
    • pp.43-50
    • /
    • 2003
  • Nowdays the apartment is a main type of modernized residential buildings. According to the improvement of construction techniques and functions of windows and doors, recent apartments are enhanced air tightness of windows, doors and building envelopes. As Infiltration is decreased and natural ventilation is reduced, energy could be saved in winter. However, indoor air quality is bad. The air Infiltration of a building could be enlarged by physical actions, such as building designs, constructions and reduction of air tightness which is caused by aging. This research analyzes and measures with KNS-4000P (Sapporo air tightness measurement) the air tightness of the high rise apartments which is recently constructed and not occupied yet. With depressurization method, the KNS-4000 installed on the window and the indoor air-leakage was measured. At that time, Air come out from the edge of the windows and doors because of the pressure differences between indoor and outdoor. We measure the amount of the air as effective air leakage areas. This method of depressurization takes less time to measure than other methods and is less affected from other conditions. We measured infiltration of total 56 household, 29 households S apartment (total floor area : $64.42m^2$) in Balan and 29 households D apartment(total floor area : $78.21m^2$) in Chonan. As a result of the field measurements at October 2003, normalized leakage area of D apartment in Cheonan was $2.05cm^2/m^2{\sim}3.49cm^2/m^2$ (average: $2.77cm^2/m^2$) and normalized leakage area of S apartment in Balan is $1.23cm^2/m^2{\sim}1.68cm^2/m^2$ (average: $1.5cm^2/m^2$).

공동주택 커뮤니티 센터의 공간프로그램 개발 (Space Programing of Community Center in Multi-Family Housing)

  • 주서령;박연심;박경옥;장성수
    • 한국주거학회논문집
    • /
    • 제13권3호
    • /
    • pp.33-43
    • /
    • 2002
  • The purpose of this paper is to develop a space program of the new community center in multi-family housing. The community center defined in this study is a communal facility which integrate cultural and welfare facilities and activity programs into a complex. Through the analysis of the community programs and spaces for multi-family housing community, a new community center program is proposed. And basic area guidelines are proposed through the making of the space modelling of the important area of the center. According to the guidelines, more spaces compared to the present standards and conditions are needed for a new community center. However, the adjustment of area regulation is essential, considering the fast changing trend of resident's social needs. A new regulation system that controls the total area of function spaces of a community center, rather than controlling each function and area, is required. This kind of system makes it possible to decide programs freely within the limit of total floor area regulation by neighborhood's characteristics and residents'preference.