• Title/Summary/Keyword: Total Effective Moment

Search Result 50, Processing Time 0.024 seconds

Prediction of the Total Effective Moment (ME) Using Stroke Range in Lightweight Piezoelectric Composite Actuator(LIPCA) (경량압전 복합재료 작동기의 작동범위를 이용한 총유효 모멘트 (ME)의 예측)

  • Yoon Kwang-Joon;Kim Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.2 s.245
    • /
    • pp.120-127
    • /
    • 2006
  • The fatigue behavior of LIPCA was so sensitive to the manufacturing condition, the environmental factors and the change of the test apparatus. Therefore, we could be considering not only the relationship between the stroke range $({\Delta}h)$ and actuating frequency but also the relationship between the stroke range $({\Delta}h)$ and the total effective moment $(M^E)$. Thus, this study proposed the calculation method of the applying $M^E$ when the $({\Delta}h)$ of LIPCA was increased from 1.mm to 20mm. To estimate the relationship between the total effective moment $(M^E)$ and the Bernoulli-Euler bending moment (M) was reviewed. And the residual stress distribution of LIPCA and THUNDER using the CLT was evaluated. In conclusions, converting the $({\Delta}h)$ of LIPCA to the radius of curvature (p) and calculating the $(M^E)$, it was found that the p by the $M^E$ changed similarly as the $({\Delta}h)$. It was found that the $M^E$ was 2.2 times as the M. While CFRP and PZT of LIPCA, which had the superior compressive characteristic, had the compressive residual stress, GFRP was subject to the tensile residual stress. Since this reversed configuration between the compressive residuals stress and the tensile one was made, the requirement of the stroke range $({\Delta}h)$ increase was satisfied.

Service load response prediction of reinforced concrete flexural members

  • Ning, Feng;Mickleborough, Neil C.;Chan, Chun-Man
    • Structural Engineering and Mechanics
    • /
    • v.12 no.1
    • /
    • pp.1-16
    • /
    • 2001
  • A reliable and accurate method has been developed to predict the flexural deformation response of structural concrete members subject to service load. The method that has been developed relates the extent of concrete cracking, measured as a function of the magnitude of applied moment in a member, to the reduction in the effective moment of inertia of cracked reinforced concrete members under service load conditions. The ratio of the area of the moment diagram where the moment exceeds the cracking moment, to the total area of the moment diagram for any loading, provides the basis for the calculation of the effective moment of inertia. This ratio also represents mathematically a probability of crack occurrence. Verification of this method for the determination of the effective moment of inertia has been achieved from an experimental test program, and has included beam tests with different loading configurations, and shear wall tests subjected to a range of vertical and lateral load levels. Further verification of this method has been made with reference to the experimental investigation of other recently published work.

Relationship Between CFRP Ply Orientation and Performance Stroke in Piezoelectric Zirconate Titanate Composite Actuator(PZTCA) of Artificial Muscle (인공근육에 적용되는 압전복합재료 작동기의 탄소섬유 배향각과 작동변위의 관계)

  • Kim Cheol-Woong;Lee Sung-Hyuk;Yoon Kwang-Joon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.641-644
    • /
    • 2005
  • The aim of this research is to evaluate the relationship between the total effective moment $(M^E)$ and Bemoulli-Euler bending moment (M) when the ply orientations of UD CFRP in Piezoelectric Zirconate Titanate Composite Actuator (PZTCA) are changed. The obtained results as follows. Firstly, as the performance test results by the CFRP ply orientation, the performance of [0] and [90] were stable. However, while the performance of [+45] was suddenly decreased after 5 hours. Secondly, the change of $M^E$ by the CFRP ply orientation was evaluated. As the CFRP ply orientation was increased from [0] to [+60], the $M^E$ were gradually decreased. However, they became a little bit increased from [+60] to [90]. Finally, after the change of M by the CFRP ply orientation was evaluated, it was found that $M^E=2.2M$ was valid for just [0] and that there was a relationship between $M^E$ and M according to the ply orientation.

  • PDF

Prediction of deflection of high strength steel fiber reinforced concrete beams and columns

  • Kara, Ilker Fatih;Dundar, Cengiz
    • Computers and Concrete
    • /
    • v.9 no.2
    • /
    • pp.133-151
    • /
    • 2012
  • This paper presents an analytical procedure for the analysis of high strength steel fiber reinforced concrete members considering the cracking effect in the serviceability loading range. Modifications to a previously proposed formula for the effective moment of inertia are presented. Shear deformation effect is also taken into account in the analysis, and the variation of shear stiffness in the cracked regions of members has been considered by reduced shear stiffness model. The effect of steel fibers on the behavior of reinforced concrete members have been investigated by the developed computer program based on the aforementioned procedure. The inclusion of steel fibers into high strength concrete beams and columns enhances the effective moment of inertia and consequently reduces the deflection reinforced concrete members. The contribution of the shear deformation to the total vertical deflection of the beams is found to be lower for beams with fibers than that of beams with no fibers. Verification of the proposed procedure has been confirmed from series of reinforced concrete beam and column tests available in the literature. The analytical procedure can provide an accurate and efficient prediction of deflections of high strength steel fiber reinforced concrete members due to cracking under service loads. This procedure also forms the basis for the three dimensional analysis of frames with steel fiber reinforced concrete members.

Proposal of Equation on Changable Performance Stroke (Δ h) and Radius of Curvature (ρ) According to the CERP Ply Orientation in PZTCA (CFRP 배향각에 따라 변화하는 PZTCA의 작동변위(Δ h)와 곡률반경(ρ)의 관계식 제안)

  • Hong Jung-Hwa;Yoon Kwang-Joon;Kim Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.3 s.246
    • /
    • pp.318-327
    • /
    • 2006
  • Due to the diversified use of recent Piezoelectric Zirconate Titanate Composite Actuate. (PZTCA), various PZTCAs with the different ply orientation of the fiber layer have been applied. For this reason, the applicable bending moment equation is necessary even though the fiber layer ply orientation and the laminate configuration are changed. The aim of this research is to evaluate the relationship between the total effective moment $(M^E)$ and Bernoulli-Euler bending moment (M) when the ply orientations of UD CFRP are changed. In conclusions, firstly, as the performance test results by the CFRP ply orientation, the performance of [0] and [90] were stable. However, while the performance of [+45] was suddenly decreased after 5 hours. Secondly, the change of $(M^E)$ by the CFRP ply orientation was evaluated. As the CFRP ply orientation was increased from [0] to [+60], the $(M^E)$ were gradually decreased. However, they became a little bit increased from [+60] to [90]. Finally, after the change of M by the CFRP ply orientation was evaluated, it was found that $M^E=2.2M$ was valid for just [0] and that there was a relationship between $M^E$ and M according to the ply orientation.

A Comparative Study on Design by Actual Stress and Design by Member Strength in Bolt Connections (철골볼트 접합부 존재응력설계와 부재내력설계의 비교 연구)

  • 이만승
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.04a
    • /
    • pp.94-101
    • /
    • 1999
  • There are two methods commonly used in design of splice plate connection of frame structure. The one is Design by Actual Stress which can sufficiently transfer actual force to an adjacent member using rows of bolts. The other is Design by Member Strength which is able to transfer total allowable stress of effective section area to a connected member. In real design, as a matter of convenience, Standard Connection Drawings have used according to Design by Member Strength. But this method underestimate connection force in shear connection where large connection moment occured. In this study, these Design methods are compared by connection moment in shear connections. and the adequate use of them are recommended. Also In order to evaluate more accurately the actual stress of splice plate of flange on moment. connection, a new calculation method of it is recommended.

  • PDF

Multigroup cross-sections generated using Monte-Carlo method with flux-moment homogenization technique for fast reactor analysis

  • Yiwei Wu;Qufei Song;Kuaiyuan Feng;Jean-Francois Vidal;Hanyang Gu;Hui Guo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2474-2482
    • /
    • 2023
  • The development of fast reactors with complex designs and operation status requires more accurate and effective simulation. The Monte-Carlo method can generate multi-group cross-sections in arbitrary geometry without approximation on resonances treatment and leads to good results in combination with diffusion codes. However, in previous studies, the coupling of Monte-Carlo generated multi-group cross-sections (MC-MGXS) and transport solvers has shown relatively large biases in fast reactor problems. In this paper, the main contribution to the biases is proved to be the neglect of the angle-dependence of the total cross-sections. The flux-moment homogenization technique (MHT) is proposed to take into account this dependence. In this method, the angular dependence is attributed to the transfer cross-sections, keeping an independent form for the total sections. For the MET-1000 benchmark, the multi-group transport simulation results with MC-MGXS generated with MHT are improved by 700 pcm and an additional 120 pcm with higher order scattering. The factors that cause the residual bias are discussed. The core power distribution bias is also significantly reduced when MHT is used. It proves that the MCMGXS with MHT can be applicable with transport solvers in fast reactor analysis.

The Effect of Total Contact Inserts on the Gait Parameters During High-Heeled Shoes Walking (높은 굽 신발 보행 시 전면 접촉인솔이 보행 변수에 미치는 영향)

  • Moon, Gon-Sung;Kim, Tack-Hoon
    • Physical Therapy Korea
    • /
    • v.18 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • The purpose of this study was to investigate the effect of high heeled shoes with the total contact insert (TCI) on the frontal plane of the joints for the lower extremity during the gait. Ten healthy females voluntarily participated in this study and the height of the high heeled shoes was 7 cm. A three-dimensional motion analysis system (VICON) and force plates were used to analyze the movements of the joints for the lower extremities. The results were as follows: There were no significant differences for the angle value on the event of the gait cycle in the maximum eversion and inversion of the ankle joint, the varus and valgus of the knee joint, and the adduction and abduction of the hip joint (p>.05). But, there was a significant difference or the range of motion in the ankle joint (p<.05). The value of ankle and knee moment with a TCI was less than the value for no TCI. And there were significant differences for the moment value of the maximum inversion and eversion on the ankle joint and for the maximum varus and valgus on the knee joint (p<.05). Therefore, a TCI would be effective in stabilizing the joints of the lower extremities and increasing the balance of a body to reduce the injure from a fall during the gait.

A Study on the Optimal Design Method of Reinforced Concrete Two Way Slabs (Direct Method에 의한 鐵筋콘크리트 二方向슬라브의 最適設計에 관한 硏究)

  • Kim, Yong-Hee;Lyu, Hong-Leal;Park, Moon-Ho
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.2
    • /
    • pp.97-105
    • /
    • 1984
  • We have, at present, found some studies on the optimum design of reinforced concrete about the simple slab but very few about the multi-story and multi-span slab. The aim of this study is to make a optimum design of coalesced beam and column slab constructure. Some results of the evaluation by using the optimalized algorithm that was developed in this study are as follows. 1. Slab was mainly restricted by the constraint of effective depth, bending moment, and minimum steel ratio; especially the effective depth was the preceding crifical constraint. In the optimum design of slab, therefore, the constraint about the minimum thickness should be surely considered. 2. This optimum design is good economy as much as some 3.4&~6.2% compared with the conventional design method. 3. In most case, it was converged by 3 to 6 iteratin regardless of the highest or lowest value and only in case of N=1 and case 1, there is a little oscillation after the 3rd iteration but it makes no difference in taking either the highest or lowest value because the range of oscillation is low as much as about 1.2% of the total construction cost. 4. In this study the result seeking for constraints that make no difference in the least cost design shows that shear stress and maximum steel ration may not be considered in it. 5. Bending moment was converged by one time iteration regardless of the initial value, while steel ratio, in most case, by two times because both bending moment and steel ratio are the fuction of effective depth.

  • PDF