• Title/Summary/Keyword: Torsional Test

Search Result 321, Processing Time 0.018 seconds

Development of a Finite Element Model for Evaluating Torsional Stiffness of the Frame of a Large Truck (대형트럭 프레임의 비틀림 강성 평가를 위한 유한요소 모델 개발)

  • Oh Chae-Youn;Moon Il-Dong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.4 s.235
    • /
    • pp.563-569
    • /
    • 2005
  • This paper develops a finite element model of a cabover type large truck. The finite element model is for evaluating torsional stiffness of the frame of the large truck. The torsional test of the frame is conducted in order to validate the developed finite element model. A load cell is used to measure the load applied to the frame. An angle sensor is used to measure the torsional angle. An actuator is used to apply a load to the frame. A vertical upward load and a vertical downward load are applied to the frame in the torsional test. The frame's torsional stiffness is computed with the measured load and torsional angle in the torsional test. The finite element model of the large truck includes cab, deck and payload, suspension, and tire. Cab, deck, and suspension are modeled not to affect the frame's torsional stiffness. The simulation is performed with the developed finite element model for evaluating the frame's torsional stiffness. The simulation results show a very good correlation with the torsional test results in the tendency of changing of the frame's torsional stiffness not only with the direction of the applying load but also with the amount of the applying load. In addition, the simulation results predict the measured torsional stiffness of the frame with about $5{\%}$ error.

Torsional response of stiffened circular composite spar (보강된 복합재 원형 스파의 비틀림 거동)

  • Kim, Sung Joon;Lee, Donggeon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.27 no.1
    • /
    • pp.51-56
    • /
    • 2019
  • To reduce the structural weight, thin-walled circular composite tube has been used as a main spar of high altitude-long endurance unmanned air vehicle(HALE UAV). Predicting the torsional response of stiffened circular spar is complex due to the inhomogeneous nature of section properties, which are dependent on fiber architecture and constituent material properties. The stiffener were placed in the top and bottom sectors of a tube to increase the torsional capabilities such as the rigidity and buckling strength. Numerical simulations were performed to estimate the effect of the stiffener on the torsional capacities. A static experimental test was performed on a stiffened tube, and the test results were compared with a numerical model. The numerical models showed good correlation and demonstrated the ability to predict the torsional capacity. Results presented herein will exhibit the effectiveness of stiffener on torsional strength and stiffness.

Thickness of shear flow path in RC beams at maximum torsional strength

  • Kim, Hyeong-Gook;Lee, Jung-Yoon;Kim, Kil-Hee
    • Computers and Concrete
    • /
    • v.29 no.5
    • /
    • pp.303-321
    • /
    • 2022
  • The current design equations for predicting the torsional capacity of RC members underestimate the torsional strength of under-reinforced members and overestimate the torsional strength of over-reinforced members. This is because the design equations consider only the yield strength of torsional reinforcement and the cross-sectional properties of members in determining the torsional capacity. This paper presents an analytical model to predict the thickness of shear flow path in RC beams subjected to pure torsion. The analytical model assumes that torsional reinforcement resists torsional moment with a sufficient deformation capacity until concrete fails by crushing. The ACI 318 code is modified by applying analytical results from the proposed model such as the average stress of torsional reinforcement and the effective gross area enclosed by the shear flow path. Comparison of the calculated and observed torsional strengths of existing 129 test beams showed good agreement. Two design variables related to the compressive strength of concrete in the proposed model are approximated for design application. The accuracy of the ACI 318 code for the over-reinforced test beams improved somewhat with the use of the approximations for the average stresses of reinforcements and the effective gross area enclosed by the shear flow path.

Experimental investigation of characteristics of torsional wind loads on rectangular tall buildings

  • Li, Yi;Zhang, J.W.;Li, Q.S.
    • Structural Engineering and Mechanics
    • /
    • v.49 no.1
    • /
    • pp.129-145
    • /
    • 2014
  • In order to investigate the characteristics of torsional wind loads on rectangular tall buildings, five models with different rectangular cross-sections were tested in a boundary wind tunnel. Based on the test results, the RMS force coefficients, power spectrum densities as well as vertical correlation functions of torsional wind loads were analyzed. Formulas that took the side ratio as parameters were proposed to fit the test results above. Comparisons between the results calculated by the formulas and the wind tunnel measurements were made to verify the reliability of the proposed formulas. An simplified expression to evaluate the dynamic torsional wind loads on rectangular tall buildings in urban terrain is presented on basis of the above formulas and has been proved by a practical project. The simplified expressions as well as the proposed formulas can be applied to estimate wind-induce torsional response on rectangular tall buildings in the frequency domain.

Nominal Torsional Moment Strength of RC Beam with Torsional Moment Strength of Concrete (콘크리트의 비틀림강도를 포함한 RC보의 공칭비틀림강도)

  • 박창규
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.3
    • /
    • pp.73-84
    • /
    • 2002
  • Nominal shear strength of concrete beam is the combined strength of concrete shear strength and steel shear strength in current design code. But Torsional moment strength of concrete is neglected in calculation of the nominal torsional moment strength of reinforced concrete beam in current revised code. Tensile stress of concrete strut between cracks is still in effect due to tension stiffening effect. But the tensile stresses of concrete after cracking are neglected in bending and torsion in design. The torsional behavior is similar to the shear behavior in mechanics. Therefore the torsional moment strength of concrete should be concluded to the nominal torsional moment strength of reinforced concrete beam. To verify the validity of the proposed model, the nominal torsional moment strengths according to CEB, two ACI codes(89, 99) and proposed model are compared to experimental torsional strengths of 55 test specimens found in literature. The nominal torsional moment strengths by the proposed model show the best results.

Wind-induced lateral-torsional coupled responses of tall buildings

  • Wu, J.R.;Li, Q.S.;Tuan, Alex Y.
    • Wind and Structures
    • /
    • v.11 no.2
    • /
    • pp.153-178
    • /
    • 2008
  • Based on the empirical formulas for power spectra of generalized modal forces and local fluctuating wind forces in across-wind and torsional directions, the wind-induced lateral-torsional coupled response analysis of a representative rectangular tall building was conducted by setting various parameters such as eccentricities in centers of mass and/or rigidity and considering different torsional to lateral stiffness ratios. The eccentricity effects on the lateral-torsional coupled responses of the tall building were studied comprehensively by structural dynamic analysis. Extensive computational results indicated that the torsional responses at the geometric center of the building may be significantly affected by the eccentricities in the centers of mass and/or rigidity. Covariance responses were found to be in the same order of magnitude as the along-wind or across-wind responses in many eccentricity cases, suggesting that the lateral-torsional coupled effects on the overall wind-induced responses can not be neglected for such situations. The calculated results also demonstrated that the torsional motion contributed significantly to the total responses of rectangular tall buildings with mass and/or rigidity eccentricities. It was shown through this study that the framework presented in this paper provides a useful tool to evaluate the wind-induced lateral-torsional coupled responses of rectangular buildings, which will enable structural engineers in the preliminary design stages to assess the serviceability of tall buildings, potential structural vibration problems and the need for a detailed wind tunnel test.

Torsional modal testing of a non-ferromagnetic shaft by magnetostrictive patch transducers (자기변형 패치 트랜스듀서를 이용한 비자성 축의 비틀림 모달 테스팅)

  • Cho, Seung-Hyun;Han, Soon-Woo;Park, Chan-Il;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1159-1164
    • /
    • 2006
  • Torsional vibration is an important vibration mode when shafts, cylinders and pipes are considered. However, the modal testing of torsional vibrations is not an easy job to carry out because of the lack of proper transducers. This work presents a new torsional vibration transducer based on the magnetostrictive principle and its application to torsional modal testing. The transducer is so designed as to generate/measure only torsional vibrations excluding other vibration modes such as longitudinal and bending vibrations. The transducer is composed of ferromagnetic patches bonded to a test structure, permanent magnets, and a solenoid. Though patches and magnets are bonded to a structure, torsional vibrations are generated and measured wirelessly by a solenoid encircling a test structure. The proposed transducer works even at considerably high frequencies, say, tens of kilohertz. Furthermore, the transducer can be manufactured at a low price. To check the performance of the proposed method, the torsional modal testing on a hollow aluminum shaft was conducted. The results, such as eigenfrequencies, obtained by the proposed transducer agreed favorably with theoretical results.

  • PDF

Torsional Modal Testing of a Non-ferromagnetic Shaft by Magnetostrictive Patch Transducers (자기변형 패치 트랜스듀서를 이용한 비자성 축의 비틀림 모달 테스팅)

  • Cho, Seung-Hyun;Han, Soon-Woo;Park, Chan-Il;Kim, Yoon-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.8 s.113
    • /
    • pp.879-885
    • /
    • 2006
  • Torsional vibration is an important vibration mode when shafts, cylinders and pipes are considered. However, the modal testing of torsional vibrations is not an easy task to carry out because of the lack of proper transducers. This work presents a new torsional vibration transducer based on the magnetostrictive principle and its application to torsional modal testing. The transducer is so designed as to generate/measure only torsional vibrations excluding other vibration modes such as longitudinal and bending vibrations. The transducer is composed of ferromagnetic patches bonded to a test structure, permanent magnets, and a solenoid. Though patches and magnets are bonded to a structure, torsional vibrations are generated and measured wirelessly by a solenoid encircling a test structure. The proposed transducer works even at considerably high frequencies, say, tens of kilohertz. Furthermore, the transducer can be manufactured at a low price. To check the performance of the proposed method, the torsional modal testing on a hollow aluminum shaft was conducted. The results, such as eigenfrequencies, obtained by the proposed transducer agreed favorably with theoretical results.

Failure Modes of RC Beams with High Strength Reinforcement (고강도 비틀림보강철근을 사용한 철근콘크리트 보의 파괴모드)

  • Yoon, Seok-Kwang;Lee, Su-Chan;Lee, Do-Hyeong;Lee, Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.2
    • /
    • pp.143-150
    • /
    • 2014
  • To avoid abrupt torsional failure due to concrete crushing before yielding of torsional reinforcement and control the diagonal crack width, design codes specify the limitations on the yield strength of torsional reinforcement of RC members. In 2012, Korean Concrete Institute design code increased the allowable maximum yield strength of torsional reinforcement from 400 MPa to 500 MPa based on the analytical and experimental research results. Although there are many studies regarding the shear behavior of RC members with high strength stirrups, limited studies of the RC members regarding the yield strength of torsional reinforcement are available. In this study, twelve RC beams having different yield strength of torsional reinforcement and compressive strength of concrete were tested. The experimental test results indicated that the torsional failure modes of RC beams were influenced by the yield strength of torsional reinforcement and the compressive strength of concrete. The test beams with normal strength torsional reinforcement showed torsional tension failure, while the test beams with high strength torsional reinforcement greater than 480 MPa showed torsional compression failure. Therefore, additional analytical and experimental works on the RC members subjected to torsion, especially the beams with high strength torsional reinforcement, are needed to find an allowable maximum yield strength of torsional reinforcement.

A study on the characteristics of torsional vibration for 4*4 vehicles drivetrain (4륜구동 차량구동계의 비틀림진동 특성에 관한 연구)

  • Choi, Eun-O;Kim, Hei-Song;Hong, Dong-Pyo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.11
    • /
    • pp.1957-1964
    • /
    • 1997
  • Torsional vibration is to vibrate strongly when the ignition pulses of the engine is excited with natural frequency of driveline. Torsional vibration like this can cause various noises as rattle and booming. For this study multi-degree of freedom analysis model of torsional vibration, which is combined with mass moment of inertia and torsional spring, was developed toward two wheel drive, four wheel drive and torsional vibration characteristics were compared and analyzed through the natural frequences, mode shapes and frequency response characteristics which was acquired by the simulation of it. The pertinence of that model was proved by the field test and the outcome of the simulations coincided with feeling test. Therefore, four wheel drive simulation model is considered to be useful thing for reducing torsional vibration of driveline and developing full-time four wheel drive vehicles.