• 제목/요약/키워드: Torque standard

검색결과 141건 처리시간 0.026초

순간전압강하에 의한 단상 민감부하 및 삼상 유도전동기의 외란 민감도에 관한 연구 (A Study on the Susceptibility of Single-phase Sensitive Loads and the Three-phase Induction Motor by Voltage Sag)

  • 윤상윤;문종필;김재철;이희태
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권1호
    • /
    • pp.37-44
    • /
    • 2006
  • In this paper we explore the susceptibility of common sensitive loads by voltage sags of power distribution systems. The experimental approach was used for obtaining the susceptibility of single-phase loads and the three-phase induction motor. The experimental result of single-phase loads was transformed to the ITIC(Information of Technology Industry Council) format and used for evaluating the adverse impacts of a individual and repetitive sags using the performance contour of the foreign standard data. In order to assess the impact of voltage sags on three-phase induction motor, also, the experiment was peformed. The experiment was focused on the current, torque, and speed loss of the motor during a voltage sag. For comparing the impacts of individual and repetitive voltage sags, the variations of motor torque is focused among the experimental results. The sensitive curves of instantaneous current peak are used to describe the susceptibility of three-phase induction motor and 진so it were used for the quantitative analysis of the impact of three-phase induction motor due to voltage sags. Through the results of experiment, we verified that some types loads have more severe impact at repetitive voltage sags than individual ones and proposed method can be effectively used to evaluate the actual impact of voltage sags.

등속성 운동시 20대 정상성인의 손목 관절근력의 정상치 측정 (Isokinetic Measures of Forearm Muscle Strength in Young Normal Adults)

  • 김도연;김현경;백승호;정경수
    • 한국전문물리치료학회지
    • /
    • 제1권1호
    • /
    • pp.47-54
    • /
    • 1994
  • This study was designed to develop an objective method of strength measurement of muscles controlling the wrist joint in normal subjects. Forty subjects (20 male, 20 female) with a mean age of 22 years, were tested isokinetically at $60^{\circ}/sec$ and $120^{\circ}/sec$. Results were as follows, 1) Peak torque for wrist flexors, extensors were significantly different for both speeds, but wrist ulnar deviator, radial deviator peak torques were not, 2) Mean values for all muscle groups controlling the wrist were not significantly different for both speeds in the female group, 3) All mean values at both $60^{\circ}/sec$ and $120^{\circ}/sec$ were significantly different between males and females, 4) Means and standard deviations of wrist joint angle of movement at peak torque were determined.

  • PDF

CFD에 의한 2D 에어포일 공력특성 및 3D 풍력터빈 성능예측 (Predicting the Aerodynamic Characteristics of 2D Airfoil and the Performance of 3D Wind Turbine using a CFD Code)

  • 김범석;김만응;이영호
    • 대한기계학회논문집B
    • /
    • 제32권7호
    • /
    • pp.549-557
    • /
    • 2008
  • Despite of the laminar-turbulent transition region co-exist with fully turbulence region around the leading edge of an airfoil, still lots of researchers apply to fully turbulence models to predict aerodynamic characteristics. It is well known that fully turbulent model such as standard k-model couldn't predict the complex stall and the separation behavior on an airfoil accurately, it usually leads to over prediction of the aerodynamic characteristics such as lift and drag forces. So, we apply correlation based transition model to predict aerodynamic performance of the NREL (National Renewable Energy Laboratory) Phase IV wind turbine. And also, compare the computed results from transition model with experimental measurement and fully turbulence results. Results are presented for a range of wind speed, for a NREL Phase IV wind turbine rotor. Low speed shaft torque, power, root bending moment, aerodynamic coefficients of 2D airfoil and several flow field figures results included in this study. As a result, the low speed shaft torque predicted by transitional turbulence model is very good agree with the experimental measurement in whole operating conditions but fully turbulent model(${\kappa}-\;{\varepsilon}$) over predict the shaft torque after 7m/s. Root bending moment is also good agreement between the prediction and experiments for most of the operating conditions, especially with the transition model.

자동차 조향장치용 TAS module을 위한 Multi-track Encoder기반 신호처리보드의 구현 (Preliminary study of Angle sensor module for Vehicle Steering System Based on Multi-track Encoder)

  • 우승탁;한춘수;백준병;이상훈;정민우;추성중;박재률;유종호;정상훈;김주영
    • 센서학회지
    • /
    • 제26권6호
    • /
    • pp.432-437
    • /
    • 2017
  • As 4.0 industry has been developed, research on a self-driving car technology and related parts of an automobile has been highly investigated recently. Particularly, a TAS(Torque Angle Sensor) module on steering wheel system has been considered as a key technology because of its precise angle, torque detection and high speed signal processing. The environmental assessment is generally required on the TAS module to examine high resolution of angle/torque detection. In the case of existing TAS module, angle detection errors has been occurred by back-lash on main and sub gear in addition to complicated structure caused by gears. In this paper, a structure of the TAS module, which minimizes the numbers of components and angle detection errors on the module compared with the existing TAS module, for vehicle steering system based on a Multi-track Encoder has been proposed. Also, angle detection signal processing board, and key technology of the TAS module were fabricated and evaluated. As a result of the experiments, we confirmed an excellent performance of the fabricated signal processing board for angle detection and an applicability of the fabricated angle detection board on the TAS module of vehicles by the environmental assessment an automobile standard.

토크 벡터링을 적용한 전기차의 선회 성능 평가에 관한 연구 (A Study of Torque Vectoring Application in Electric Vehicle for Driving Stability Performance Evaluation)

  • 이종현;이경하;김일호;정덕우;허승진
    • 한국자동차공학회논문집
    • /
    • 제22권3호
    • /
    • pp.250-256
    • /
    • 2014
  • EV(Electric Vehicle) has many benefits such as prevention of global warming and so on. But due to driving source changing from combustion engine to battery and e-motor, new R&D difficulties have arisen which changing of desired vehicle performance and multidisciplinary design constraints by means of strong coupled multi-physics domain problems. Additionally, dynamics performances of EV becomes more important due to increasing customer's demands and expectations for EV in compare with internal combustion engine vehicle. In this paper suggests model based development platform of EV through integrated simulation environment for improving analyse & design accuracy in order to solve multi-physics problem. This simulation environment is integrated by three following specialized simulation tools IPG CarMaker, AVL Cruise, DYMOLA that adapted to each purpose. Furthermore, control algorithm of TV(Torque Vectoring) system is developed using independent driven e-motor at rear wheels for improving handling performance of EV. TV control algorithm and its improved vehicle performances are evaluated by numerical simulation from standard test methods.

발레 무용수의 Fouette en dehors동작 시 하지분절에 대한 생체역학적 분석 (A Biomechanical Analysis of Lower Extremity Segment dur ing the Fouette en dehors Performed by Ballet Dancers)

  • 이진;오정환
    • 한국운동역학회지
    • /
    • 제22권1호
    • /
    • pp.43-53
    • /
    • 2012
  • The purpose of this study was to quantitatively examine the biomechanical variables of Fouette turns for expert and beginner ballet dancers and to determine the difference in the variables between the two groups. sixteen female ballet dancers participated in this study. They were divided into an expert group(age, $25.38{\pm}1.92$ years; height, $168.38{\pm}4.66$ cm; mass, $49.63{\pm}4.41$ kg) and a beginner group(age, $20.88{\pm}1.13$ years; height, $161.63{\pm}7.42$ cm; mass, $48.88{\pm}3.64$ kg) depending on their ballet experience. Descriptive data were expressed as mean ${\pm}$ standard deviation (SD) for all variables including the duration, displacement of the center of the body, velocity of the center of the body, angle of the body segments, angular velocity of the body segments, ground reaction force, lower extremity torque, muscle activity, body weight, age, and body mass. An independence t-test was conducted to determine how the following variables differed between the beginners and experts: duration, displacement of the center of the body, velocity of the center of the body, angle of the body segments, angular velocity of the body segments, ground reaction force, lower extremity torque, and muscle activity. All comparisons were made at the p<0.05 significance level. The results show that the experts scored high on the biomechanical variables, although all the variables were not significant. Significant differences were found in the angle of body segments, angular velocity of the body segments, lower extremity torque, and muscle activity(p<0.05). The findings of this study demonstrate that the experts have the required skill to make an improved Fouette turn. The findings may also help ballet dancers to learn and understand the Fouette turn.

견갑면에서의 견관절 외전정도에 따른 등속성회전운동의 근력 평가 (An Evaluation for Isokinetic Strength During Shoulder Rotation Movement in the Scapular Plane with Various Abduction)

  • 최재원;김수민;김현애;김경;황보각;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제12권2호
    • /
    • pp.95-105
    • /
    • 2000
  • Glenohumeral internal and external rotation with shoulder abducted in the frontal plane often causes impingement of the supraspinatus tendon. whereas similar activity in scapular plane does not cause impingement. The Purpose of this study was to determine if assessment among the three positions as 30 degrees, 60 degrees, 90 degrees abduction in the sitting position of the scapular plane could be affected the comparison between intemal and external peak torque, total work, average power. In this study, Isokinetic shoulder rotational strength was evaluated in twenty healthy male university students, using the Cybex NORMTM System (CYBEX Division of LUMEX, Inc., Ronkonkoma, New York). Test data was gathered in the plane of the scapular, 30 degrees of horizontal flexion anterior to coronal plane, and the subjects performed the test with the arm 30, 60, and 90degrees abducted in the sitting position. also, test speed was set at deg/sec. Statistical analysis was performed using SPSS 7.5 for Windows software and mean and standard deviations were calculated. ANOVA was used to analyze the difference of the values in the three test positions. A paired t-test was used of examining the difference in the means peak torque between external and internal rotation. Not any significant difference was found among three abduction positions in scapular plane, even though there was a consistent pattern of greater strength in the abducted position of 60 degrees. Internal relation strength peak torque and total work were greater than those of external rotation in every test positions.

  • PDF

철도 차량용 EMB의 클램핑 포스 과도응답 향상을 위한 토크 예측 제어 (Torque Predictive Control for Dynamic Performance Improvement of Clamping Force in EMB for Railroad Cars)

  • 장윤;박영수;이교범
    • 전기전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.174-184
    • /
    • 2017
  • 본 논문은 철도 차량용 electro-mechanical brake (EMB)의 클램핑 포스 과도응답 향상을 위한 토크 예측 제어 방법을 제안한다. 일반적으로 철도 차량에는 공압식 제동 시스템이 사용된다. 공압식 제동 시스템은 외부환경 변화에 민감하며, 과도응답 속도가 느리기 때문에 공주시간이 증가한다. 또한, 긴급 제동과 같은 기준 이상의 제동 토크를 인가하는 경우에 제동 효율이 낮은 단점이 있다. 이러한 공압식 제동 시스템의 단점은 철도 차량용 EMB 시스템을 적용하여 극복할 수 있다. 철도 차량용 EMB 시스템은 차량의 축중을 감소시키고, 설계 공간을 확보하기 때문에 연비 증가 및 설계 유연성 확보 등의 장점을 갖는다. 본 논문에서는 철도 차량용 EMB의 클램핑 포스 과도응답 향상을 위한 제어 방법을 제안한다. 제안하는 제어 방법의 타당성은 시뮬레이션을 통해 검증한다.

호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구 (A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE)

  • 조수미;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제36권3호
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

각가속도 변화에 의해 탐지된 슬립에 기반한 주행로봇의 견인력 제어 (Traction Control of Mobile Robot Based on Slippage Detection by Angular Acceleration Change)

  • 최현도;우춘규;강현석;김수현;곽윤근
    • 제어로봇시스템학회논문지
    • /
    • 제15권2호
    • /
    • pp.184-191
    • /
    • 2009
  • The common requirements of rough terrain mobile robots are long-term operation and high mobility in rough terrain to perform difficult tasks. In rough terrain, excessive wheel slip could cause an increase in the amount of dissipated energy at the contact point between the wheel and ground or, even more seriously, the robot could lose all mobility and become trapped. This paper proposes a traction control algorithm that can be independently implemented to each wheel without requiring extra sensors and devices compared with standard velocity control methods. The proposed traction algorithm is analogous to the stick-slip friction mechanism. The algorithm estimates the slippage of wheels by angular acceleration change, and controls the increase or decrease state of torque applied to wheels Simulations are performed to validate the algorithm. The proposed traction control algorithm yielded a 65.4% reduction of total slip distance and 70.6% reduction of power consumption compared with the standard velocity control method.