• Title/Summary/Keyword: Torque evaluation

Search Result 294, Processing Time 0.027 seconds

Comparison between Isokinetic Peak Torque and Isotonic 1RM on the Knee Joint

  • Jaehyun Yoo
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.2
    • /
    • pp.201-205
    • /
    • 2023
  • Objective: Resistance exercise is a necessary element to improve quality of life, and measurement and evaluation of muscle strength provide important information for prescription and management of rehabilitation and exercise programs. This study analyzed the correlation between direct and indirect 1RM for isokinetic maximum torque of the knee joint in order to provide useful information in the field of exercise programs. In addition, the flexion-extension ratio and the difference in left-right deviation were verified. Design: A cross-sectional study Methods: The subjects of this study were 33 healthy adult men and women without medical problems who participated in the health exercise class program at S University in Seoul. The correlation between isokinetic maximum torque and direct and indirect 1RM was analyzed, and a dependent t-test was performed to analyze the flexion-extension ratio and left-right deviation. Results: There was a high correlation between the isokinetic maximum torque and direct and indirect 1RM, and no statistically significant difference was shown between the test methods in the analysis of the flexion-extension ratio and left-right deviation. Conclusions: Isokinetic muscle function measuring equipment is expensive, so it is difficult to use it in local exercise rehabilitation and training sites. Through this study, it was found that direct and indirect 1RM isokinetic maximum torque showed a high correlation, and there was no difference in evaluating muscle function such as flexion-extension ratio and left-right deviation. Therefore, it is considered that the muscle function evaluation using 1RM in general field can be usefully utilized.

Torque Profile Measuring and Sensibility Evaluation of a Haptic Device (햅틱 장치의 프로파일 측정 및 감성 평가)

  • Jun, Cha-Soo;Choo, Heon-Seong;Park, Se-Hyung;Kim, Lae-Hyun;Shin, Sang-Kyun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.15 no.3
    • /
    • pp.222-233
    • /
    • 2010
  • Developed in this research is a TP (tangible prototyping) system, which consists of two modules; (1) a virtual reality model to evaluate the functions and appearance of the product, and (2) a haptic device to emulate tactile and kinesthetic properties of mechanical dial knobs. As an example, a washing machine is modeled using a commercial CAD system and transformed in VRML and X3D formats. Some dynamic behaviors and kinematic characteristics are programmed using X3D script and Java. Various haptic behaviors of the dial are generated by modulating torque profile according to the rotation angle. A torque profile measuring system is developed to evaluate the behaviors of the haptic dial physically. Haptic sensibility evaluations are accomplished using the TP by semantic differential method.

Analysis of the Torque Characteristics of a Multi-Degrees of Freedom Surface Permanent-Magnet Motor

  • Kang, Dong-Woo;Go, Sung-Chul;Won, Sung-Hong;Lim, Seung-Bin;Lee, Ju
    • Journal of Magnetics
    • /
    • v.15 no.1
    • /
    • pp.36-39
    • /
    • 2010
  • The multi-degrees of freedom surface permanent-magnet motor (Multi-D.O.F. SPM) has several degrees of freedom operations that are defined as the "roll", "yaw", and "pitch". Normally, the torque that is generated to rotate a rotor includes ripples. The analysis of the torque ripples is important for improving motor performance. In terms of the electric analysis, torque ripple occurs as a result of many factors, including the rotor and stator structures, the distribution of the air-gap flux density, and the waveform of the current in the coils. In particular, the torque ripple is an important factor in the stable operation of the Multi-D.O.F. SPM. Therefore, in this work, the torque ripple was analyzed using various types of magnetization for the permanent magnet. An improved model was proposed for the Multi-D.O.F. SPM based on this analysis.

Optimization of Hip Flexion/Extension Torque of Exoskeleton During Human Gait Using Human Musculoskeletal Simulation (인체 근골격 시뮬레이션을 활용한 인체 보행 시 외골격의 고관절 굴곡/신장 토크 최적화)

  • Hyeseon Kang;Jinhyun Kim
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.1
    • /
    • pp.117-121
    • /
    • 2023
  • Research on walking assistance exoskeletons that provide optimized torque to individuals has been conducted steadily, and these studies aim to help users feel stable when walking and get help that suits their intentions. Because exoskeleton auxiliary efficiency evaluation is based on metabolic cost savings, experiments on real people are needed to evaluate continuously evolving control algorithms. However, experiments with real people always require risks and high costs. Therefore, in this study, we intend to actively utilize human musculoskeletal simulation. First, to improve the accuracy of musculoskeletal models, we propose a body segment mass distribution algorithm using body composition analysis data that reflects body characteristics. Secondly, the efficiency of most exoskeleton torque control algorithms is evaluated as the reduction rate of Metabolic Cost. In this study, we assume that the torque minimizing the Metabolic Cost is the optimal torque and propose a method for obtaining the torque.

Isikinetic evaluation of the knee flexors and extensors on muscle strength in 100 men and women aged 21 - 68yr (21-68세 남녀 100명의 슬관절 굴근과 신근의 근력에 대한 등속성 평가)

  • Nam, Hyoung-Chun
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.2
    • /
    • pp.967-976
    • /
    • 2001
  • The purpose of the present study was to the investigate the effect of aging in men and women on muscle strength of knee extensor and flexors by using the cybex 6000 isokinetic dynamometer. A total of 100 volunteers participated in this study and were divided into five groups according to their chronological age as follows: 20s, 30s, 40s, 50s, 60s, 10 men and 10 women in each decade respectively. Isokinetic ($60^{\circ}{\cdot}s-l$) knee extensor and flexor peak torque, peak torque to body weight ratio, opposing muscles(flexor/extensor) peak torque ratio, deficit of peak torque between dominant and non-dominant were measured. The results obtained were as follows: 1) In men, While the aged increased. the peak torque of the knee flexor and extensor statistically sig nificant decreased in the dominant and non-dominant side. 2) In women, Statistically significant difference of knee extensor peak torque was found as the aged increased in the dominant and non-dominant side, but significant difference of knee flexor peak torque did not that. 3) In men, No significant difference in the peak torque of knee flexor to body weight ratio was found as the aged increased in the non-dominant side, but statistically significant difference in the peak torque of knee flexor to body weight weight ratio was found as the aged increased in the dominant side. 4) In women. No significant difference in the peak torque of knee flexor to body weight ratio was found as the aged increased in the dominant side, but statistically significant difference in the peak torque of knee flexor to body weight ratio was found as the aged increased in the non-dominant side. 5) In men and women, While the aged increased, statistically significant difference was found the dominant and non-dominant side in the peak torque of knee extensor to body weight ratio. 6) Peak torque of hamstring to quadriceps ratio of dominant and non-dominant side in men and women were not significantly different as the age increases. 7) Mean deficit of peak torque between dominant and non-dominant side in men and women were not significantly different as the age increases. From these results we conclude a proper exercise program is need before 50s decade to preserve in muscle strength of knee flexors and extensors.

  • PDF

The Isokinetic Strength Evaluation of Trunk Flexors and Extensors by Contranction Type (체간 굴곡근과 신전근의 수축 형태에 따른 등속성 근력평가)

  • Kim Yang-Hee;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.2
    • /
    • pp.57-69
    • /
    • 1998
  • The role of eccentric muscle activities in functional everyday activities and sport is important and equally significant to concentric conditions. Eccentric and concentric exercise and evaluation are, therefore, very important. The purposes of this study were to measure eccentric md concentric peak torgue, percentage of peak torque, average power and percentage of average power of trunk flexors and extensors by using the Cybex NORM isokinetic dynamometer, and to standardize the value obtained. Thirty four young volunteers were tested, 17 females and 17 males, who had no history of back pain or abnormality. Each subjects were tested on three repetitions for isokinetic concentric and eccentric contraction at 5 velocities. The results were as follows; 1) Peak torque percent body weight of eccentric contraction were significantly greater than concentric contraction at each angular velocity and in trunk flexors and extensors(p<0.01). 2) Peak torque percent body weight of concentric contraction were significantly decreased as the angular velocity increased both male and female(p<0.01). 3) Peak torque percent body weight of eccentric contraction were not significantly changed as the angular velocity increased both male and female(p<0.05), 4) Peak torque percent body weight of male were significantly greater than female at each angular velocity and in concentric and eccentric contraction of trunk flexors and extensors(p<0.01)

  • PDF

Evaluation of the Identification method of Joint Mechanical Properties Using Isokinetic Movement (등속운동을 이용한 관절계 역학적 특성치 정량화 방법의 유용성 평가)

  • 이창한;허지운;김철승;엄광문
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1190-1193
    • /
    • 2004
  • The purpose of this study is to evaluate the possibility of identifying joint damping property through commercially available isokinetic ergometer (BIODEX). The proposed method is to estimate the damping torque of the knee joint from the difference between the external joint torque for maintaining isokinetic movement and the gravity torque of the lower leg. The damping torque was estimated at various joint angular velocities, from which the damping property would be derived. Measurement setup was composed of the BIODEX system with an external force sensor and Labview system. Matlab was used in the analysis of the damping property. The experimental result showed that the small variation in angular velocity due to acceleration and deceleration of the crank arm resulted in greater change of inertial torque than the damping torque, so that the estimation of damping property from the isokinetic movement is difficult.

  • PDF

Reliability Evaluation of Torque Generator (토크 발생기의 신뢰성 향상)

  • Jung, D.S.;Lee, Y.B.;Park, J.W.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.59-65
    • /
    • 2012
  • Torque Generator is a product which has function to transform hydraulic energy to mechanical energy of torque and rotating speed, and be used for direction change device of agricultural machines. This study proposes failure analysis and test analysis on torque generator and introduces a process that reliability of a product is enhanced by design improvement. And also it presents improvements of maximum output torque by modifying design and surface treatment. Lastly it verifies reliability improvement by analyzing test results of before and after life test.

Control of Redundant Manipulators Using Null-Space Dynamics (여유자유도 로보트 충격제어)

  • Kim, Il-Hwan
    • Journal of Industrial Technology
    • /
    • v.15
    • /
    • pp.63-70
    • /
    • 1995
  • This paper presents an impact control algorithm for reducing the potentially damaging effects by interation of redundant manipulators with their environments. In the proposed control algorithm, the redundancy is resolved at the torque level by locally minimizing joint torque, subject to the operational space dynamic formulation which maps the joint torque set into the operational forces. For a given pre-impact velocity of the manipulator, the proposed approach is on generating joint space trajectories throughout the motion near the contact which instantaneously minimize the impulsive force which is a scalar function of manipulator's configurations. The comparative evaluation of the proposed algorithm with a local torque optimization algorithm with a local torque optimization algorithm without reducing impact is performed by computer simulation. The simulation results illustrate the effectiveness of the algorithm in reducing both the effects of impact and large torque requirements.

  • PDF

Evaluation of Trapezoidal PWM Inverter using a new Harmonic Torque Factor (새로운 고조파 토오크 평가함수에 의한 Trapezoidal PWM 인버터의 평가)

  • Lee, Chi-Hwan;Koo, Bon-Ho;Kwon, Wu-Hyen
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.754-756
    • /
    • 1987
  • In this paper, a new Harmonic Torque Factor(HTF) that represents torque ripple of induction motor is proposed. Trapezoidal PWM is analyzed to torque ripple by HTF and than we obtain optimum triangular factor at some carrier ratio. Six-step, sinusoidal PWM and Trapezoidal PWM are compared and evaluated for choosing a good control strategy of PWM inverter. It turns out that six-step inverter is better than sinusoidal PWM and Trapezoidal PWM when their carrier ratio is 9, and Trapezoidal PWM is superior to sinusoidal PWM. At induction motor is driven by PWM inverter, torque ripples are investigated by computer simulation using d-q two axis model. It is proved that a new Harmonic Torque Factor ix valid.

  • PDF