• Title/Summary/Keyword: Torque Sensor

Search Result 425, Processing Time 0.031 seconds

A study on performance measurement system of traction equipment (추진장치 성능측정 시스템에 관한 연구)

  • Han, Young-Jae;Kim, Seog-Won;Kim, Young-Guk;Park, Chan-Kyoung;Choi, Jong-Sun;Kim, Jung-Su
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.170-175
    • /
    • 2003
  • The korean high speed train(350km/h), composed of 7cars that are 2 power cars, 2 motorized car and 3 trailer cars, has been developed and is under on-line test. To verify the design requirements about the functions and traction performances of this train, KRRI(Korea Railroad Research Institute) decided to evaluate traction performances of the train during on-line test. For this purpose, such as torque, velocity, voltage and current, must be measured. KRRI has developed the measurement system that can be measured vast and various signals effectively. In this paper, we introduce traction performances of korean high speed train. The traction measurement items are focused on the verification of motor block performances. Motor block are consist of 2 motor. For this test, we verified traction performances of korean high speed train.

Experimental approach for selecting an optimal PID control gain using genetic algorithm for stewart platform (유전 알고리즘을 이용한 스튜어트 플랫폼의 최적 PID 제어 게인 선정을 위한 실험적 접근)

  • Park, Min-Kyu;Hong, Sung-Jin;Lee, Min-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.1
    • /
    • pp.73-80
    • /
    • 2000
  • The stewart platform manipulator proposed by stewart is the parallel manipulator which is composed of several independent actuators connecting the upper plate with the base plate and capable of executing a six degree of freedom motion. The manipulator has a structure of a closed loop form, and provides better load-to-weight ratio and ratio and rigidity than a serial manipulator with an open loop form. Moreover, the manipulator has high positional accuracy because position errors of actuators are not additive. Because of these advantages, this manipulator is widely used in many engineering applications such as a driving simulator, a tool of machining center, a force/torque sensor and so on. When this Stewart platform manipulator is controlled in joint space, it is difficult to design a controller using an analytic method due to nonhnearity and unknown parameters of actuators. Therefore, a PID controller is often used because of easiness in applications. To find the PID control gain, a trial-and-error method is generally used. This method is time-consuming, and does not guarantee a optimal gain. Thus, this paper proposes a GA-PID controller which selects an optimal PID control gain using genetic algorithms. And this proposed controller is evaluated experimentally and shows acceptable performance.

  • PDF

Evaluation of Remote Handling Performance with the Polarized Stereo Monitoring System (편광방식 스테레오 모니터링 시스템의 원격조작성 평가)

  • Lee, Yong-Bum;Lee, Nam-Ho;Park, Soon-Yong;Lee, Jong-Min;Jin, Sung-Il
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.55-62
    • /
    • 1996
  • This paper describes development of Polarized Stereo Monitoring System (KAERI-PSM) and compares the remote handling performance of KAERI-PSM with that of other monitoring systems, electric shutter type stereo monitoring system and general TV monitoring system. Remote handling performance is evaluated by total time and error number on remote operating experiments. Four kinds of remote handling experiments are carried out through 1) directly 2) general TV 3) electric shutter type monitor, and 4) KAERI-PSM. In these experiments six employees are participated and PUMA robot with force-torque reflectional joystic is used. The result of experiments show that camera angle against object is significant factor in monitoring and stereo monitoring system give more performance benifits in terms of accuracy and speed of remote handling operation than general TV monitoring system. In comparision of the polarized and electric shutter type stereo monitoring system, both have similar accuracy and speed for remote handling operation, but the former is superior in image quality and stability of the performance.

  • PDF

Performance Test of a Real-Time Measurement System for Horizontal Soil Strength in the Field

  • Cho, Yongjin;Lee, DongHoon;Park, Wonyeop;Lee, Kyouseung
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.304-312
    • /
    • 2016
  • Purpose: Soil strength has been measured using a cone penetrometer, which is making it difficult to obtain the spatial data required for precision agriculture. Our objectives were to evaluate real-time horizontal soil strength (RHSS) to measure soil strength in real time while moving across the field. Using the RHSS data, the tillage depth was determined, and the power consumption of a tractor and rotavators were compared. Methods: The horizontal soil-strength index (HSSI) obtained by the RHSS was compared with the cone index (CI), which was measured using a cone penetrometer. Comparison analysis in accordance with the measurement depth that increased at 5-cm interval was conducted using kriged maps at six sensing depths. For tillage control and evaluation of the power consumption, the system was installed with a potentiometer for tillage depth, a torque sensor from the rear axle, and a power take-off (PTO) shaft. Results: The HSSI was lower than the CI, but they were the same at 54.81% of the total grids for the 5-cm depth and at 3.85% for the 10-cm depth. In accordance with the recommended tillage map, tillage operations between 0 and 15 cm left 2.3% and 7% residue cover on the soil, and that between 20 and 10 cm covered a wider utilization of 3% and 18.4%, respectively. When the tillage depth was 15 cm, the comparison result of the power requirements between the PTO and rear axle in terms of control performance revealed that the maximum power requirements of the axle and PTO were 44.63 and 23.24 kW, respectively. Conclusions: An HSSI measurement system was evaluated by comparison with the conventional soil strength measurement system (CI) and applied to a tractor to compare the tillage power consumption. Further study is needed on its application to various farm works using a tractor for precision agriculture.

A Development of Rehabilitation System for Upper Limb Using Robot Manipulator (로봇을 이용한 상지 재활 시스템에 관한 연구)

  • 원주연;심형준;한창수
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.309-318
    • /
    • 2003
  • In this paper a 6 degree-of-freedom robot was studied for medical purpose. In the past the robot used for industry field was utilized for medical robot but in these days the robot used for rehabilitation. welfare, and service. This system was Proposed for a stroke patient or a patient who can not use one arm. A master-slave system was constructed to exercise either paralysis or abnormal arm using normal arms movement. Study on the human body motion result was applied to calculate a movement range of humans elbow and shoulder. In addition, a force-torque sensor is applied to estimate the rehabilitation extent of the patient in the slave robot. Therefore, the stability of the rehabilitation robot could be improved. By using the rehabilitation robot, the Patient could exercise by himself without any assistance In conclusion. the proposed system and control algorithm were verified by computer simulation and system experiment.

Flow Characteristics and Drag Reduction at Different Pressures of Counterflow Air Jets in Supersonic Flow (초음속 환경에서 역분사 공기 제트의 압력 변화에 따른 유동 특성 및 항력 감소)

  • Choi, Jongin;Lee, Jaecheong;Kang, Seungwon;Huh, Hwanil
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.1
    • /
    • pp.58-65
    • /
    • 2018
  • To improve the performance of high-speed vehicles, various studies have been carried out on the head of vehicles. In this study, tests are conducted on flow characteristics and drag reduction using counterflow air jets in supersonic flow. The flow is visualized by the Schlieren method using a high-speed camera, and the drag is measured using a torque sensor according to the injection pressure conditions. The results of the measurements indicate that the flow changes from unsteady state to steady state for injection pressure ratios between 1.58 and 1.70, and drag reduction is observed as the pressure of the counterflow air jets increases.

Study of Oil Jet Effect on the Temperature of Piston Head (피스톤 헤드 온도에 오일 제트가 미치는 영향에 대한 연구)

  • Min, Sunki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.536-540
    • /
    • 2018
  • As the performance of engines improves, the temperature of engines is increasing, resulting in a high piston temperature. An excessively high piston temperature may result in torque drop or engine failure. An oil jet is used to reduce the piston temperature. In this study, to monitor the effect of oil jet, a templug was used to measure the piston temperature. A templug is a kind of sensor and the hardness of the templug changes according to the piston temperature. Using a templug, the maximum temperature of the piston was measured with and without an oil jet. The piston temperature was lowered using the oil jet. The highest temperature region changed from the center crown to the front/rear area. In addition, the temperature difference between the highest and lowest regions became smaller.

Experimental Study on Propulsion Characteristic of Autonomous Intervention ROV (자율작업용 원격운용잠수정의 추진 특성에 관한 실험 연구)

  • Yeu, Taekyeong;Lee, Yoongeon;Chae, Junbo;Yoon, Sukmin;Lee, Yeongjun
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.454-461
    • /
    • 2019
  • In autonomous interventions using an underwater vehicle with a manipulator, grasping based on target detection and recognition is one of the core technologies. To complete an autonomous grasping task, the vehicle body approaches the target closely and then holds it through operating the end-effector of the manipulator, while the vehicle maintains its position and attitude without unstable motion. For vehicle motion control, it is very important to identify the hydrodynamic parameters of the underwater vehicle, including the propulsion force. This study examined the propulsion characteristics of the autonomous intervention ROV developed by KRISO, because there is a difference between the real exerted force and the expected force. First, the mapping between the input signal and thrusting force for each underwater thruster was obtained through a water tank experiment. Next, the real propulsion forces and moments of the ROV exerted by thrusting forces were directly measured using an F/T (force/torque) sensor attached to the ROV. Finally, the differences between the measured and expected values were confirmed.

Detection and Identification of CMG Faults based on the Gyro Sensor Data (자이로 센서 정보 기반 CMG 고장 진단 및 식별)

  • Lee, Jung-Hyung;Lee, Hun-Jo;Lee, Jun-Yong;Oh, Hwa-Suk;Song, Tae-Seong;Kang, Jeong-min;Song, Deok-ki;Seo, Joong-bo
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.2
    • /
    • pp.26-33
    • /
    • 2019
  • Control moment gyro (CMG) employed as satellite actuators, generates a large torque through the steering of its gimbals. Although each gimbal holds a high-speed rotating wheel, the wheel imbalances induces disturbance and degrades the satellite control quality. Therefore, the disturbances ought to be detected and identified as a precaution against actuator faults. Among the method used in detecting disturbances is the state observers. In this paper, we apply a continuous second order sliding mode observer to detect single disturbances/faults in CMGs. Verification of the algorithm is also done on the hardware satellite simulator where four CMGs are installed.

Stability Analysis of Multi-motor Controller based on Hierarchical Network (계층적 네트워크 기반 다중 모터 제어기의 안정도 분석)

  • Chanwoo Moon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.677-682
    • /
    • 2023
  • A large number of motors and sensors are used to drive a humanoid robot. In order to solve the wiring problem that occurs when connecting multiple actuators, a controller based on a communication network has been used, and CAN, which is advantageous in terms of cost and a highly reliable communication protocol, was mainly used. In terms of the structure of the controller, a torque control type structure that is easy to implement an advanced algorithm into the upper controller is preferred. In this case, the low communication bandwidth of CAN becomes a problem, and in order to obtain sufficient communication bandwidth, a communication network is configured by separating into a plurality of CAN networks. In this study, a stability analysis on transmission time delay is performed for a multi-motor control system in which high-speed FlexRay and low-speed CAN communication networks are hierarchically connected in order to obtain a high communication bandwidth, and sensor information and driving signals are delivered within the allowed transmission time. The proposed hierarchical network-based control system is expected to improve control performance because it can implement multiple motor control systems with a single network.