• Title/Summary/Keyword: Torque Measurement

Search Result 386, Processing Time 0.059 seconds

MEASUREMENT OF FIELD PERFORMANCE FOR TRACTOR

  • M. J. NahmGung;Park, C. H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.819-826
    • /
    • 2000
  • This study was performed to develop a measurement system of tractor field performance for plow and rotary operations. Measurement system for tractor consisted of torque sensors to measure torque of drive axles and PTO axle, speed sensors to measure rotational speed of drive axles and engine, microcomputer to control data logger, and data logger as I/O interface system. The measurement system was installed on four-wheel-drive tractor. Four-element full-bridge type strain gages were used for torque measurement of drive axles and optical encoders were used to measure speeds of drive axles and engine. Slip rings were mounted on the rotational axles. Signals from sensors were inputted to data logger that was controlled by microcomputer with parallel communication. Sensors were calibrated before the field tests. Regression equations were found on completion of the calibrations. The field experiment was performed at paddy fields and uplands. Rotary and plow were used when the tractor was operated in the field. Travelling speeds of the tractor were 1.9 km/h, 2.7 km/h, 3.7 km/h, 5.5 km/h, 8.2 km/h, and 11.8 km/h. Operating depths of implements were maintained approximately 20cm during the tests. Torque data of drive axles were different at each location during plow and rotary operations. Results showed that torque of rear axles were greater than those of front axles. Total torque were 6860 - 11064 Nm at the upland and 7360 - 14190 Nm at the paddy field for plow operations. It was found that torque at the paddy field were about 20% greater than those at the upland for plow operations. Torque data showed that rotary operations required less power than plow operation at the paddy field and the upland. Torque measurements at each axle for rotary operations were only 8 - 16% of plow operations in the upland and 15 - 20% in the paddy field.

  • PDF

Full Scale Measurement Method for Rudder Torque & Force (Rudder Torque 및 Force 실선 계측 Method)

  • Lim, Jong-Ho;Park, Kyung-Rak;Ok, Yu-Kwan
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2011.09a
    • /
    • pp.1-4
    • /
    • 2011
  • The full spade rudder for the high speed has advantage to prevent gap cavitation of the rudder. DSME has developed the full spade rudder and GL has carried out CFD analysis and FE analysis to confirm strength and fatigue for DSME and Owner. Necessarily, it needs to compare rudder torque & rudder force between CFD, FE analysis and full scale measurement. This report introduces the measurement method and application of strain gauge for measuring the rudder torque and rudder force for the 8,400 TEU container ship.

  • PDF

Development of device measuring very high torque via torque arm with attached load cells (로드셀과 토크암을 이용한 대용량 토크 측정장치 개발에 관한 연구)

  • Lee, Y.B.;Han, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.1
    • /
    • pp.6-10
    • /
    • 2010
  • A measurement of very high torque for track drive unit in construction equipment is usually in difficulties due to the requirement of a torque meter with high capacity, and the limitation of geometry for an experimental set-up. To improve the troublesome problem, a new device was proposed, where a torque transmitted through the torque arm can be measured by load cells attached at each torque arm. The experimental set-up of the new device was carried out in order to measure the torque values for a mechanical feedback type planetary gear box, in which the power flow circulates itself in a closed-loop. The new device enables to measure torque values of 60,000Nm. Additionally, the measured values were estimated statistically in the aspect of their repeatability and reproducibility, so that an acceptable behaviour as a measuring device can be confirmed.

  • PDF

Three Dimensional Measurements and Parameter Identification of Force and Torque Distmbances of High Speed Rotating Actuators (고속회전구동기의 힘 및 토크 외란 3차원 측정과 파라미터 추정)

  • Lee, Hyun-Ho;Oh, Hwa-Suk;Cheon, Dong-Ik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.4
    • /
    • pp.409-416
    • /
    • 2007
  • A momentum type actuator produces force and torque disturbances as well as its designed control torque. These disturbances are ones of the largest disturbance sources inside the spacecraft, which deteriorate the pointing stability of the high precision spacecraft. The measurement and analysis of actuator disturbances are therefore imperative for such a spacecraft, and thus a three dimensional torque measurement table has been developed for that purpose. The data acquired from the measurement table are processed in the frequency domain and displayed in the power spectral density(PSD). Through this process, disturbance model parameters are obtained and used for the attitude stability simulation. The process has been adopted for the disturbance measurement of the reaction wheel, and the validity of measurements and parameter identification procedure is verified.

Torque and Force Measurement of a Prototype HAU Reaction Wheel and the Effect of Disturbance on the Attitude Stability of Spacecraft

  • Oh, Hwa-Suk;Kwon, Jae-Wook;Lee, Hyunwoo;Nam, Myung-Ryong;Park, Dong-Jo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.743-751
    • /
    • 2001
  • A Prototype reaction wheel, named the Hankuk Aviation University (HAU) reaction wheel, has been developed for KAISTSAT satellite series. Torque and force disturbances are inherent in reaction wheels, and thus the force and torque characteristics should be examined for every newly developed reaction wheel. The torque and force disturbance noises in the prototype HAU reaction wheel are measured with a torque-measuring table developed for the present study. A new measuring procedure based on a simple principle is applied for the measurements. The frequency characteristics of the torque and force noises are analyzed by examining the power spectral density. The effect of the torque noise on the attitude stability is also examined through numerical simulations with a single-axis attitude model. The noise-induced attitude error and jitter and found to be well below the specified error limits for the KAISTSAT satellite series.

  • PDF

A study on torque measuring technique for track drive unit of earthmoving equipment with very large capacity (대형 건설장비용 주행유닛의 토크 측정기술에 관한 연구)

  • Lee, Yong-Bum;Han, Seung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.4
    • /
    • pp.97-103
    • /
    • 2009
  • Since a demand for an extensive range of earthmoving equipment like a hydraulic excavator with a capacity of 85tons has been asked in construction fields, a performance of its track drive unit has to be verified experimentally. Among the verification of the performances, a torque measurement is at issue, in which a torque meter is utilized widely. However, the very large scaled torque meter is necessary when a discharged torque from the track drive unit is increased significantly. In addition, the price for experimental set-up of a torque meter is too high due to its limitation of the geometry such as long length, and a break down in operation occurs frequently. In this study, to measure a high torque up to 200,000Nm, a new technique was proposed as an alternative of conventional measurement by using a torque meter. The new technique enables to measure the high torque stably in a compact space via a torque arm and two load cells. The experimental results showed a propriety of the proposed torque measuring technique for a track drive unit with very large capacity.

  • PDF

A STUDY ON THE CORRELATION BETWEEN IMPLANT STABILITY VALUES AND INITIAL INSERTION TORQUE

  • Lee Jong-Hyuk;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.314-324
    • /
    • 2006
  • Statement of problem. Osseointegration is important mechanism of dental implant but it is not easy to evaluate. Indirect measurement is non-invasive and clinically applicable but they need more study about correlation between indirect values and degree of osseointegration. Purpose. The aims of this study were to evaluate the coefficient of correlation between indirect measurement and direct measurement under different healing time, and assessment of effect of initial insertion torque to the implant stability. Material and Methods. 20 rabbits received 3 implants on each side of tibia. Three kinds of implants (machined surface implant, Sandblasted with Large grit and Acid etched implant, Resorbable Blast Media treated implant) were used. During the surgery implant insertion torque were measured with $Osseocare^{TM}$. After the 1, 4, 8, 12 weeks of healing time, animals were sacrificed and stability values (Implant Stability Quotient with $Osstell^{TM}$, removal torque with torque gauge) were measured. Results. The Bone quality of rabbit tibia was classified into 2 groups according to the insertion torque. Resonance frequency analysis (ISQ) and removal torque showed positive correlation until $4^{th}$ week (r=0.555, p=0.040). After $8^{th}$ week (r=0.011, p=0.970) the correlation became weak and it turned negative at $12^{th}$ week (r=-0.074, p=0.801). Insertion torque and ISQ showed changing correlation upon the healing time ($1^{st}$ week: r=0.301, p=0.033, $4^{th}$ week: r=-0.429, p=0.018, $8^{th}$ week: r=0.032, p=0.865, $12^{th}$ week: r=-0.398, p=0.029). Insertion torque and removal torque has positive correlation but it was not statistically significant ($1^{st}$ week: r=0.410, p=0.129, $4^{th}$ week: r=0.156, p=0.578, $8^{th}$ week: r=0.236, p=0.398, $12^{th}$ week: r=0.260, p=0.350). Conclusion. In this study, bone quality may affect the degree of osseointegration positively during healing time and correlation between ISQ and degree of osseointegration can be different according to the healing time and bone quality.

Joint Module with Joint Torque Sensor Having Disk-type Coupling for Torque Error Reduction (토크 오차 감소를 위한 디스크형 커플링을 갖는 토크센서가 내장된 로봇 관절모듈)

  • Min, Jae-Kyung;Kim, Hwi-Su;Song, Jae-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.2
    • /
    • pp.133-138
    • /
    • 2016
  • Force control and collision detection for a robot are usually conducted using a 6-axis force/torque sensor mounted at the end-effector. However, this scheme suffers from high-cost and the inability to detect collisions at the robot body. As an alternative, joint torque sensors embedded in each joint were used, which also suffered from various errors in torque measurement. To resolve this problem, a robot joint module with an improved joint torque sensor is proposed in this study. In the proposed torque sensor, a cross-roller bearing and disk-type coupling are added to prevent the moment load from adversely affecting the measurement of the joint torque under consideration. This joint design also aims to reduce the stress induced during the assembly process of the sensor. The performance of the proposed joint torque sensor was verified through various experiments.

Low Torque High Precision Automatic Backlash Measuring System for Aircraft Machine Gun Control Reducer (항공 기관총 구동제어 감속기용 저토크 고정밀 자동 백래시 측정장치 개발)

  • Park, Taehyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.7
    • /
    • pp.34-42
    • /
    • 2022
  • Minimizing the backlash of gears and reducers is important for their proper and precise functioning. In this study, an automatic backlash measuring system was developed for the mass production and quality control of a military-grade reducer. The developed automatic backlash measurement system eliminates human error during the backlash measurement process. It also reduces the manufacturing time and digitizes the backlash number. The system was tested for an aircraft machine gun control reducer that required low-torque and high-precision conditions. The test results show that the torque range was 0.820-4.788 Nm. The maximum torque error is less than 0.231 N·m at 2.943 N·m, and 1.2 arcmin of the maximum backlash error with ± 0.3 arcmin of repeatability. The developed system satisfies all required conditions: torque of 1-3 Nm, torque accuracy within ± 0.5 N·m, and backlash accuracy of ± 3 arcmin.