• Title/Summary/Keyword: Toric

Search Result 57, Processing Time 0.019 seconds

Simple factor analysis of measured data

  • Kozar, Ivica;Kozar, Danila Lozzi;Malic, Neira Toric
    • Coupled systems mechanics
    • /
    • v.11 no.1
    • /
    • pp.33-41
    • /
    • 2022
  • Quite often we have a lot of measurement data and would like to find some relation between them. One common task is to see whether some measured data or a curve of known shape fit into the cumulative measured data. The problem can be visualized since data could generally be presented as curves or planes in Cartesian coordinates where each curve could be represented as a vector. In most cases we have measured the cumulative 'curve', we know shapes of other 'curves' and would like to determine unknown coefficients that multiply the known shapes in order to match the measured cumulative 'curve'. This problem could be presented in more complex variants, e.g., a constant could be added, some missing (unknown) data vector could be added to the measured summary vector, and instead of constant factors we could have polynomials, etc. All of them could be solved with slightly extended version of the procedure presented in the sequel. Solution procedure could be devised by reformulating the problem as a measurement problem and applying the generalized inverse of the measurement matrix. Measurement problem often has some errors involved in the measurement data but the least squares method that is comprised in the formulation quite successfully addresses the problem. Numerical examples illustrate the solution procedure.

The Optical Tolerances' Decision of the Ophthalmic Dispensing for Korean Models (한국형 안경조제의 광학적 허용오차 설정)

  • Kim, YongGeun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.189-199
    • /
    • 1998
  • The system for optical tolerances of completion spectacles was made to sum of the accumulated error - the circumstances on composing prescription, the visual-distance, the tilting angle, the losing of a temple, the vertex distance, the axis of toric lens and the sloping of lens etc. It was given by the relation of allowed values size(T) and power(D), $T=T_0e^{-aD}$. Here, $T_0$ is the size of allowed values of plane-lens with power is 0 and ${\alpha}$ is the factor of allowed values. In case of being adopted to new form s tolerance corresponding to RAL 915, for the tolerance is large direction, the factor of allowed values ${\alpha}$ is $0.166(T_0=5.90)$ and for the tolerance is small direction, the factor of allowed values ${\alpha}$ is $0.166(T_0=2.95)$.

  • PDF

Development of Ftheta Lens for Laser Scanning Unit (Laser Scanning Unit용 FΘ 렌즈 개발)

  • Jeong, In-Sook;Ban, Min-Sung;Son, Kwang-Eun;Lee, Byoung-Bag
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.13-19
    • /
    • 2013
  • Ftheta Lens, whose image height is proportional to its field view angle, is one of the most important parts in Laser Scanning Unit(LSU). In this paper $f{\theta}$ lens design, mold production and modification method of lens design and mold are introduced. Lens design was carried out with Zemax and Special Toric surfaces were applied for lens surfaces to minimize distortion both in main and sub scanning directions. And a high precision machine with 1nm resolution was used to fabricate lens mold cores. After injection the lens was evaluated and the difference from design was examined. This difference was compensated by modifying lens design and new lens mold cores were made according to modified lens design to obtain the quality of original design.

Inverse model for pullout determination of steel fibers

  • Kozar, Ivica;Malic, Neira Toric;Rukavina, Tea
    • Coupled systems mechanics
    • /
    • v.7 no.2
    • /
    • pp.197-209
    • /
    • 2018
  • Fiber-reinforced concrete (FRC) is a material with increasing application in civil engineering. Here it is assumed that the material consists of a great number of rather small fibers embedded into the concrete matrix. It would be advantageous to predict the mechanical properties of FRC using nondestructive testing; unfortunately, many testing methods for concrete are not applicable to FRC. In addition, design methods for FRC are either inaccurate or complicated. In three-point bending tests of FRC prisms, it has been observed that fiber reinforcement does not break but simply pulls out during specimen failure. Following that observation, this work is based on an assumption that the main components of a simple and rather accurate FRC model are mechanical properties of the concrete matrix and fiber pullout force. Properties of the concrete matrix could be determined from measurements on samples taken during concrete production, and fiber pullout force could be measured on samples with individual fibers embedded into concrete. However, there is no clear relationship between measurements on individual samples of concrete matrix with a single fiber and properties of the produced FRC. This work presents an inverse model for FRC that establishes a relation between parameters measured on individual material samples and properties of a structure made of the composite material. However, a deterministic relationship is clearly not possible since only a single beam specimen of 60 cm could easily contain over 100000 fibers. Our inverse model assumes that the probability density function of individual fiber properties is known, and that the global sample load-displacement curve is obtained from the experiment. Thus, each fiber is stochastically characterized and accordingly parameterized. A relationship between fiber parameters and global load-displacement response, the so-called forward model, is established. From the forward model, based on Levenberg-Marquardt procedure, the inverse model is formulated and successfully applied.

Generation of Lens surface by moving mask lithography (가변 속도 이동식 마스크를 이용한 렌즈 곡면 형성)

  • Lee Joon-Sub;Park Woo-Jae;Song Seok-Ho;Oh Cha-Hwan;Kim Pill-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.508-515
    • /
    • 2005
  • We propose a fabrication method for refractive lens by variable velocity moving mask lithography and slit pattern. Distribution of exposure dose should be controlled for the curved photoresist surface that works as a refractive surface. We analyze theoretically the distribution of exposure dose by change of moving velocity, moving direction of mask and the shape of mask pattern, and confirm for the curved surface experimentally. The lens could have sag height of a few of hundreds ${\mu}m$, by using thick photoresist or Deep RIE process.

A Study on the Lifetime Estimation and Leakage Test of Rubber O-ring in Contacted with Fuel at Accelerated Thermal Aging Conditions (가속노화조건 하 연료접촉 고무오링의 수명예측 및 누유시험 연구)

  • Chung, Kunwoo;Hong, Jinsook;Kim, Young-wun;Han, Jeongsik;Jeong, Byunghun;Kwon, Youngil
    • Tribology and Lubricants
    • /
    • v.35 no.4
    • /
    • pp.222-228
    • /
    • 2019
  • As rubber products such as O-rings, which are also known as packings or toric joints, come in regular, long term contact with liquid fuel, they can eventually swell, become mechanically weakened, and occasionally crack; this diminishes both their usefulness and intrinsic lifetime and could cause leaks during the steady-state flow condition of the fuel. In this study, we evaluate the lifetime of such products through compression set tests of FKM, a family of fluorocarbon elastomer materials defined by the ASTM international standard D141; these materials have great compression, sunlight, and ozone resistance as well as a low gas absorption rate. In this process, O-rings are immersed in the liquid fuel of airtight containers that can be expressed as a compression set, and the liquid fuel leakage in a flow rig tester at variable temperatures over 12 months is investigated. Using the Power Law model, our study determined a theoretical O-ring lifetime of 2,647 years, i.e. a semi-permanent lifespan, by confirming the absence of liquid fuel leakage around the O-ring assembled fittings. These results indicate that the FKM O-rings are significantly compatible for fuel tests to evaluate long-term sealing conditions.

Trends and Refractive Status of Cataract Surgery - An Optometry Clinic-Based Survey in Chungbuk (백내장 수술 경향과 굴절상태 - 충북 지역의 안경원 중심으로 조사)

  • Kim, Hyeong-Su;Son, Jeong-Sik;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.143-148
    • /
    • 2013
  • Purpose: The aim of this study was to investigate the distribution of age and gender, types of intraocular lens (IOL), and refractive errors in subjects who had cataract surgery. Methods: 2,217 subjects who had cataract surgery were surveyed at an optometry clinic in Chungbuk from 2010 to 2012. Information about IOL was obtained from case history, reflective and retroillumination images IOL by auto refracto-keratometer. Refractive errors were determined by objective and subjective refraction. Results: The mean age of the subjects was $71.74{\pm}10.62$ years. The number of cataract surgeries increased from 524 persons in 2010 to 888 persons in 2012. Of the subjects surveyed, 52 persons (2.3%) were under the 40 years of age, 144 persons (6.5%) were in 50s, 404 persons (18.2%) were in 60s, 1,132 persons (51.1%) were in 70s, 485 persons (21.9%) were in above 80s. Cataract surgery was significantly prevalent in more female (1,338 persons, 60.4%) than in male (879 persons, 39.6%). Types of IOL were 2,141 persons (96.6%) for monofocal lens, special IOLs such as multifocal, accommodative and toric lens were 76 persons (3.4%). The distribution of refractive errors after cataract operation were 1,588 eyes (38.5%) for simple myopic astigmatism, 327 eyes (7.9%) for simple hyperopic astigmatism, 601 eyes (14.6%) for mixed astigmatism, 1,240 eyes (30.0%) for myopia, 136 eyes (3.3%) for hyperopia, and 234 eyes (5.7%) for emmetropia. The uncorrected and best corrected visual acuity of the subjects were $0.55{\pm}0.25$ and $0.80{\pm}0.23$, respectively. Conclusions: The prevalence of cataract surgery increased with age until 70s years of age, it was more prevalent in men than women over 60s, and frequency of special types of IOL were low. Most cataract surgeries left residual refractive errors. Therefore even after cataract surgery it may need spectacles for better vision at either distance or near.