• Title/Summary/Keyword: Topology Errors

Search Result 53, Processing Time 0.021 seconds

Identification of Parameter Errors in Electric Power Systems by WLAV State Estimation (WLAV 상태추정에 의한 전력계통 파라미터 에러 추정에 관한 연구)

  • Kim, Hong-Rae;Gwon, Hyeong-Seok;Kim, Dong-Jun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.9
    • /
    • pp.451-458
    • /
    • 2000
  • This paper addresses the issues of the parameter error detection and identification in electric power systems. In this paper, the parameter error identification and estimation is carried out as part of the state estimation. A two stage estimation procedure is used to detect and identify the parameter errors. The suspected parameters are identified by the WLAV state estimator as the first stage. A new WLAV state estimator adding the suspected system parameters in the state vector is used to estimate the exact value of parameter errors. Supporting examples are given by using IEEE 14 bus system.

  • PDF

Diagnostic System of Modeling Errors Generated from IGES CAD Data Exchange (IGES CAD 데이터의 교환에서 오류 진단 시스템)

  • Park, Sang-Ho;Park, Jong-Wook;Han, Soon-Heung;Choi, Young;Yang, Jung-Sam;Lee, Byung-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.218-225
    • /
    • 2003
  • A diagnostic system has been developed which reports modeling errors generated when exchanging CAD data using IGES (Initial Graphics Exchange Specification) format. The system determines whether the CAD data contains errors. It also helps to define the criteria for determining the integrity and interoperability of CAD data with downstream applications of another CAD/CAM/CAE/PDM systems. The methodology of our algorithms is to analyze IGES model data by identifying errors and anomalies with respect to the diagnosis of geometry and topology. The GUI (Graphic User Interface) of the developed system helps users to input values and to visualize diagnostic results at real time.

Development of a CAD-based Utility for Topological Identification and Rasterized Mapping from Polygonal Vector Data (CAD 수단을 이용한 벡터형 공간자료의 위상 검출과 격자도면화를 위한 유틸리티 개발)

  • 조동범;임재현
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.4
    • /
    • pp.137-142
    • /
    • 1999
  • The purpose of this study is to develope a CAD-based tool for rasterization of polygonal vector map in AutoCAD. To identity the layer property of polygonal entity with user-defined coordinates as topology, algorithm in processing entity data of selection set that intersected with scan line was used, and the layers were extracted sequentially by sorted intersecting points in data-list. In addition to the functions for querying and modifying topology, two options for mapping were set up to construct plan projection type and to change meshes' properties in existing DTM data. In case of plan projection type, user-defined cell size of 3DFACE mesh is available for more detailed edge, and topological draping on landform can be executed in case of referring DTM data as an AutoCAD's drawing. The concept of algorithm was simple and clear, but some unexpectable errors were found in detecting intersected coordinates that were AutoCAD's error, not the utility's. Also, the routines to check these errors were included in algorithmic processing. Developed utility named MESHMAP was written in entity data control functions of AutoLISP language and dialog control language(DCL) for the purpose of user-oriented interactive usage. MESHMAP was proved to be more effective in data handling and time comparing with GRIDMAP module in LANDCADD which has similar function.

  • PDF

X-Band 6-Bit Phase Shifter with Low RMS Phase and Amplitude Errors in 0.13-㎛ CMOS Technology

  • Han, Jang-Hoon;Kim, Jeong-Geun;Baek, Donghyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.4
    • /
    • pp.511-519
    • /
    • 2016
  • This paper proposes a CMOS 6-bit phase shifter with low RMS phase and amplitude errors for an X-band phased array antenna. The phase shifter combines a switched-path topology for coarse phase states and a switch-filter topology for fine phase states. The coarse phase shifter is composed of phase shifting elements, single-pole double-throw (SPDT), and double-pole double-throw (DPDT) switches. The fine phase shifter uses a switched LC filter. The phase coverage is $354.35^{\circ}$ with an LSB of $5.625^{\circ}$. The RMS phase error is < $6^{\circ}$ and the RMS amplitude error is < 0.45 dB at 8-12 GHz. The measured insertion loss is < 15 dB, and the return losses for input and output are > 13 dB at 8-12 GHz. The input P1dB of the phase shifter achieves > 11 dBm at 8-12 GHz. The current consumption is zero with a 1.2-V supply voltage. The chip size is $1.46{\times}0.83mm^2$, including pads.

A Study on the Applications of a Geographic Information Systems To A Transportation Planning Model (교통모형에서의 지리정보시스템 활용방안에 관한 연구)

  • Kim, Dae-Ho;Park, Jin-Woo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.1 no.2 s.2
    • /
    • pp.167-175
    • /
    • 1993
  • This article contains three objectives. First it is to revise unnecessary procedures of a transportation models and transform results of a model into an image. Second objectives is to develop an operational structures which automatically input all data needed from arc-node topology to link-node topology of transportation network. By solving the network discrepancy, time and money for constructing to transportation can be saved. In addition, the rate of errors that my caused during data input process can be reduced. Conclusively, it is found that the integration package may provide user friendliness and reduce the rate of errors. The package can extract informations such as distance between zones and nodes, lane numbers, and hierarchy from arc-node topology for executing SDI. Another advantage of integration is the ability of spatial analysis. The integrated package may provide adequate arrangements of traffic facilities and checking systems of the shortest path. Finally, the database function of GIS package provides various information about study area for transportation analysis.

  • PDF

Design and homogenization of metal sandwich tubes with prismatic cores

  • Zhang, Kai;Deng, Zichen;Ouyang, Huajiang;Zhou, Jiaxi
    • Structural Engineering and Mechanics
    • /
    • v.45 no.4
    • /
    • pp.439-454
    • /
    • 2013
  • Hollow cylindrical tubes with a prismatic sandwich lining designed to replace the solid cross-sections are studied in this paper. The sections are divided by a number of revolving periodic unit cells and three topologies of unit cells (Square, Triangle and Kagome) are proposed. Some types of multiple-topology designed materials are also studied. The feasibility and accuracy of a homogenization method for obtaining the equivalent parameters are investigated. As the curved elements of a unit cell are represented by straight elements in the method and the ratios of the lengths of the curved elements to the lengths of the straight elements vary with the changing number of unit cells, some errors may be introduced. The frequencies of the first five modes and responses of the complete and equivalent models under an internal static pressure and an internal step pressure are compared for investigating the scope of applications of the method. The lower bounds and upper bounds of the number of Square, Triangular and Kagome cells in the sections are obtained. It is shown that treating the multiple-topology designed materials as a separate-layer structure is more accurate than treating the structure as a whole.

Shape design for viscoelastic vibration isolators to minimize rotational stiffness (회전강성 최소화를 위한 절연요소의 형상 설계)

  • Oh, Hwan-Youp;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.343-347
    • /
    • 2008
  • Design of shape for visco-elastic vibration isolation elements, which are very cost-effective and so popular in many applications is frequently based on experiences, intuitions, or trial and errors. Such traditions in shape design make it difficult for drastic changes or new concepts to come out. In this paper, both topological method and shape optimization method are combined together to find out a most desirable isolator shape efficiently by using two commercial engineering programs. ABAQUS and MATLAB. The procedure is divided into two steps. At the first step, a topology optimization method is employed to find an initial shape. where density of either 0 or 1 for finite elements is used for physical realizability. At the second step, based on the initial shape, finer tuning of the shape is done by boundary movement method. An illustration of the procedure will be presented for a mount of an air-conditioner compressor system and the effectiveness will be discussed.

  • PDF

Shape Design for Viscoelastic Vibration Isolators to Minimize Rotational Stiffness (회전강성 최소화를 위한 절연요소의 형상 설계)

  • Oh, Hwan-Youp;Kim, Kwang-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.12
    • /
    • pp.1250-1255
    • /
    • 2008
  • Design of shape fur visco-elastic vibration isolation elements, which are very cost-effective and so popular in many applications is fi?equently based on experiences, intuitions, or trial and errors. Such traditions in shape design make it difficult for drastic changes or new concepts to come out. In this paper, both topological method and shape optimization method are combined together to find out a most desirable isolator shape efficiently by using two commercial engineering programs, ABAQUS and MATLAB. The procedure is divided into two steps. At the first step, a topology optimization method is employed to find an initial shape, where density of either 0 or 1 for finite elements is used fur physical realizability. At the second step, based on the initial shape, finer tuning of the shape is done by boundary movement method. An illustration of the procedure is presented fur a mount of an air-conditioner compressor system and the effectiveness is discussed.

Development of a Diagnosis System far CAD Model Errors using OpenCASCADE (OpenCASCADE를 이용한 CAD 모델의 오류 진단 시스템의 개발)

  • Yang, Jeong-Sam;Han, Soon-Hung;Choi, Yong;Park, Sang-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.151-158
    • /
    • 2002
  • Automotive engineers involved in a new car project use various CAD systems that are chosen based on work requirements. For example, engineers in Hyundai Motors are using Pro/Designer and Alias fur the style design, but they use CATIA to design parts and assemblies, ANSYS for FEM analysis, and Pro/Engineer to design engines. Because they use different CAD systems, they have difficulties in collaborative design. Data, which contains errors, is transferred between CAD systems. It is difficult to find out such errors in a large CAD model. An evaluation method for CAD models has been developed in this study. This diagnosis tool analyses a STEP or an IGES file generated from a CAD system, and produces a quantitative error report. The tool has been tested with actual data sets. This paper proposes an algorithm that produces mathematical error values of entities of IGES models that have geometrical data, and entities of STEP models that have topological data, and inspects every part off model. To develop this system, we have used the OpenCASCADE kernel, which is an open source kernel developed by Matra Datavision of France.

KPX's EMS Network Analysis Operation Status in Korea Power System (KPX의 한국 전력 계통에서 EMS 계통해석기능 활용실태 소개)

  • Kang, Hyung-Koo;Han, Hee-Cheon
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.30-34
    • /
    • 2005
  • Due to old Toshiba EMS's database size limit and hardware old aging, KPX(Korea Power Exchange) had introduced New EMS from AREVA(old ALSTOM) in July 2002. After then KPX had committed many man power and time to normalize EMS NA(Network Analysis) functions for using real power system. At initial stage, to normalize State Estimator which is the backbone of all other NA functions and DTS(Dispatcher Training Simulator}, KPX had corrected numerous topology errors, network model errors, non-scanned and wrongly scanned SCADA measured errors. After SE function study, running test and tuning, State Estimator could finally have been run properly and stably from June 2003. Based on SE running, KPX had normalized real time Contingency Analysis, and study mode Power Flow, STNET and DTS. From early 2004, dispatchers have been trained to use NA and DTS for the purpose of stable SE running, NA operation & results reading and urgent equipment outage reviewing. EMS NA have been greatly contributed to operate real time power system stably. Above NA normal operation by KPX own efforts under the no experience of NA running, KPX made a good precedent. This paper is intended to introduce EMS NA normalization process, operation status, and etc in Korea power system operation.

  • PDF