• 제목/요약/키워드: Top floor

검색결과 238건 처리시간 0.024초

평상복 착용시 인체의 자세가 의복압에 미친 영향 (Effects of Body Postures on Garment Pressure in Daily Wear)

  • 김양원
    • 한국생활과학회지
    • /
    • 제13권1호
    • /
    • pp.153-158
    • /
    • 2004
  • With considerable development of comfortable and functional clothing in recent years, we need to evaluate the effects of garment pressure in daily wear on each parts of human body because the garment pressure is important to design the clothing. This study was designed to examine the effects of body postures on garment pressure on each parts of human body in the actual clothing conditions. All the data were collected from 50 volunteered subjects. The Garment pressure was measured in lune and December with 8 points CPMS clothing pressure system from scapular, upper am, elbow, under arm, front waist line, side waist line, abdomen, crista ilica, upper hip, middle hip, front thigh, back thigh, front knee and back knee. The postures of subjects were controlled with 3 positions such as standing (posture 1), sitting on the chair (posture 2), and sitting on the floor (posture 3) during measurement of clothing pressure. Clothing weights were more in men than in woman. It showed that clothing weights had no effects on the garment pressure. In this study, however, just the garment pressures on scapular and top of the hip increased significantly by clothing weight (p<. 05). Clothing horizontally pressed on scapular and top of hip but not on other parts. When subjects stood up, the garment pressure was the highest on the side waist. Especially, clothing pressure on the front waist point was lower than that of the left side waist. On the upper parts of the human body, the garment pressure of left side waist was the highest, and followed by front waist, crista ilica, and abdomen in order. When subjects were sitting on the chair, the garment pressure on the lower parts of the human body was the highest on the top of hip. When the subjects were sitting on the chair or on the floor, the surface area on their skin of hip and waist parts increased by postures. In addition, it showed that men felt more comfortable than women on higher clothing pressure level.

  • PDF

위험물 저장시설의 무기질 바닥마감재와 이를 이용한 시공방법에 관한 연구 (A Study on Development and Construction Methods of the Inorganic Floor Finishing Material of Hazardous Material Storage Facilities)

  • 오동석;유철희;김병덕;김흠;박상민
    • 한국가스학회지
    • /
    • 제18권4호
    • /
    • pp.35-43
    • /
    • 2014
  • 무기질 바닥마감재로 기존 위험물 저장시설의 유기질계 바닥재의 문제점을 극복할 수 있다. 하지만 기존 시공된 바닥재를 제거하는데 있어서 제거기와 바닥재의 물리적 충돌에 의해 불꽃이 발생될 수 있다. 이러한 위험물 저장시설에서의 폭발에 의한 화재가 발생할 수 있는 위험요소를 억제하도록 기존 바닥재를 제거하지 않고 시공할 수 있다. 또한, 상도제는 대전방지제가 함유되어 있어 위험물 저장시설에 있어서 바닥마감재 시공 후 발생될 수 있는 정전기에 의한 2차적 피해를 억제 할 수 있어 효과적이다. 따라서 본 연구에서 개발된 무기질 바닥마감재는 점검자의 안전 관리적 측면과 경제적 측면에 효과가 있을 것으로 기대된다.

Resorption of bone graft after maxillary sinus grafting and simultaneous implant placement

  • Kim, Young-Kyun;Kim, Su-Gwan;Kim, Bum-Su;Jeong, Kyung-In
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권3호
    • /
    • pp.117-122
    • /
    • 2014
  • Objectives: The purpose of this study was to evaluate the sinus bone graft resorption over 3 years after two-stage implant placement. Materials and Methods: The subjects for this study included 30 patients whose maxillary posterior ridges were too atrophic for implants. Bone-added osteotome sinus floor elevation was used in 15 maxillary sinuses, while the bone graft by lateral approach technique was used in 25 maxillary sinuses. The height from the top of the fixture to the sinus floor was estimated immediately after implant placement and the follow-up period was over 3 years. The surgery was classified with two groups: sinus bone grafting with and without autogenous bone. All implants were placed simultaneously. Results: The mean vertical bone loss was $3.15{\pm}2.95mm$. The survival rate of implants was 94.7%. Conclusion: The amount of bone resorption was not significantly associated with the surgical methods, the type of bone graft materials used, or sinus perforation during surgery.

바닥 복사난방 배관설비에서 배관파열 사례 연구 (A Case Study on the Plumbing Pipe Burst of Floor Radiant Heating)

  • 정홍도;신용한;박진관;정효민;정한식
    • 설비공학논문집
    • /
    • 제24권10호
    • /
    • pp.745-749
    • /
    • 2012
  • Heating pipes burst was occurred in the apartment complex that was applied floor radiant heating system. There were two opinions for the cause of the bursted heating pipes that was the flaw during construction and defects in the product and also there were conflicting among them. Officials analyzed it in order to investigate the cause of the rupture. Tensile test results showed different tensile strength between the lower part of heating pipe and the upper part of heating pipes. The lower tensile strength is maintained while the top was not secured. The reason why rupture heating pipes is that flow velocity isn't secured and then the air get stagnant. Stagnant air makes hardening. It is caused rupturing. The proper flow rate was confirmed 0.166 m/sec after experiment. It isn't make stagnant air inside heating pipes.

A STUDY FOR DOSE DISTRIBUTION IN SPENT FUEL STORAGE POOL INDUCED BY NEUTRON AND GAMMA-RAY EMITTED IN SPENT FUELS

  • Sohn, Hee-Dong;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • 제36권4호
    • /
    • pp.174-182
    • /
    • 2011
  • With the reactor operation conditions - 4.3 wt% $^{235}U$ initial enrichment, burn-up 55,000 MWd/MTU, average power 34 MW/MTU for three periods burned time for 539.2 days per period and cooling time for 100 hours after shut down, to set up the condition to determine the minimum height (depth) of spent fuel storage pool to shut off the radiation out of the spent fuel storage pool and to store spent fuels safely, the dose rate on the specific position directed to the surface of spent fuel storage pool induced by the neutron and gamma-ray from spent fuels are evaluated. The length of spent fuel is 381 cm, and as the result of evaluation on each position from the top of spent fuel to the surface of spent fuel storage pool, it is difficult for neutrons from spent fuels to pass through the water layer of maximum 219 cm (600 cm from the floor of spent fuel storage pool) and 419 cm (800 cm from the floor of spent fuel storage pool) for gamma-ray. Therefore, neutron and gamma-ray from spent fuels can pass through below 419 cm (800 cm from the floor) water layer directed to the surface of spent fuel storage pool.

납-고무베어링을 적용한 제어장비의 동적 특성평가 (Dynamic Property Evaluation of Control Equipment using Lead Rubber Bearing)

  • 이경진;김갑순;서용표
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.341-348
    • /
    • 2002
  • In these days, The base isolation system is often used to improve the seismic capacity of the structures instead of conventional techniques of strengthening the structural members. The purpose of this study is to evaluate dynamic property evaluation of control equipment using lead Lead Rubber Bearing. In this study, a base isolation test of seismic monitoring control cabinet with LRB(lead rubber bearing) was performed. The cabinet will be installed on access floor in MCR(main control room) of nuclear power plant. Details and dynamic characteristics of the access floor were considered in the construction of testing specimen. N-S component of El Centre earthquake was used as seismic input motion. Acceleration response spectrums in the top of cabinets showed that the first mode frequency of cabinet with LRB(lead rubber bearing) was shifted to 7.5 Hz in compared with 18Hz of cabinet without LRB and the maximum peak acceleration was reduced in a degree of22 percent from 2.35 g to 1.84 g

  • PDF

하방 촬영된 깊이 영상을 이용한 신장 추정 (Estimation of Human Height Using Downward Depth Images)

  • 김흥준;이동석;권순각
    • 한국멀티미디어학회논문지
    • /
    • 제20권7호
    • /
    • pp.1014-1023
    • /
    • 2017
  • In this paper, we propose a method for estimating the human height by using downward depth images. We detect a point with the lowest depth value in an object as top of the head and estimate the height by calculating the depth difference with the floor. Since the depth of the floor varies depending on the angle of the camera, the correction formula is applied. In addition, the binarization threshold is variably applied so that height can be estimated even when several people are adjacent. Simulation results show that the proposed method has better performance than the conventional methods. The proposed method is expected to be widely used in body measurement, intelligent surveillance, and marketing.

LQG design scheme for multiple vibration controllers in a data center facility

  • Kohiyama, Masayuki;Yoshida, Minako
    • Earthquakes and Structures
    • /
    • 제6권3호
    • /
    • pp.281-300
    • /
    • 2014
  • This study proposes a scheme to design control parameters for a data center facility with a vibration controller on its top floor and a secondary isolation device with its own vibration controller designed to protect vibration-sensitive computer equipment. The aim is to reduce the effects of acceleration and drift from an earthquake on computer servers placed on the isolation device that must operate during a seismic event. A linear elastic model is constructed and the evaluation function of the linear quadratic Gaussian (LQG) control is formulated. The relationship between the control parameters and the responses is examined, and based on the observations, a control parameter design scheme is constructed to reduce the responses of both the building and the computer server effectively.

대학교 기숙사의 실내공기질 환경 개선에 관한 연구 (A Study on Environmental Improvement of Indoor Air Quality in University Dormitory)

  • 김호진;양정훈;석호태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1398-1405
    • /
    • 2008
  • As the structure, material and construction of building develop continuously, so the recent residential buildings are being large, high-rise and group. High-rise residential buildings consume a lot of energy on supplying cold and hot water. As well, high-rise residential buildings bring on discomfortable use and unexpected conditions on account of faucet outlet pressure rise and the difference of water supply pressure between top floor and bottom floor. Thus, the purpose of this study is to research on using conditions of cold and hot water supply system through survey and field measurement in high-rise residential buildings and to analyze problems.

  • PDF

황토벽돌벽 주택의 실내온열환경에 관한 연구 (A Study on the Indoor Thermal Environment of House Using Earth Brick Wall)

  • 이재윤
    • 한국주거학회논문집
    • /
    • 제15권1호
    • /
    • pp.25-32
    • /
    • 2004
  • The purpose of this study is to understand the indoor thermal environment in the earth brick wall building what is called a ecological Architecture. To investigate thermal performances of the earth brick walls, it measured indoor and outdoor air temperature, relative humidity, globe temperature and PMV in reference house. The result of this study were summarized as the followings; 1) When the outdoor average air temperature was $21.8^{\circ}$, livingroom was $24.9^{\circ}$, kitchen was $25.1^{\circ}$ and 2nd floor room was $25.6^{\circ}$ at 150 cm height from the floor. 2) Although the average outdoor relative humidity was 78%, the livingroom was 67.5%. 3) As the air temperature difference between at the top and bottom was $0.6^{\circ}$ in living room, this value was below 1 % of PPD by ASHRAE Handbook. 4) Predicted Mean Vote(PMV) by ISO-7730 was +0.41.