• Title/Summary/Keyword: Top floor

Search Result 238, Processing Time 0.028 seconds

Analysis of Cases Using Top-Down Construction Method Under Various Site Condition (현장 조건에 따른 Top-Down 공법 사례분석에 관한 연구)

  • Shin, Hyun-Jung;Shin, Kyoo-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.197-199
    • /
    • 2011
  • To utilize the Top-Down construction method, it is required to analyse building area, floors, and soil conditions to choose the three basic elements of retaining wall, base column, and floor structure. The purpose of this research is to compare the methods of Top-Down with other construction methods. The research method is to analyse the project conditions of Top-Down project cases. The aim is to develop a method of selecting alternatives, considering construction characteristics, work schedule, supporting methods, foundation types.

  • PDF

Load Carrying Capacity of Top Down Prefounded Columns on Different Excavation Schedule (굴착순서에 따른 Top Down 선기둥 지지력 산정)

  • Rhim, Hong-Chul;Hwang, Hee-Sun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.4 s.22
    • /
    • pp.45-52
    • /
    • 2006
  • Top Down method is more widely used in downtown construction, recently. As underground construction constitutes a significant portion of the total construction cost and time in Top Down construction, it is important to develop a construction method to reduce the time required in underground works. The purpose of this study is to analyze load carrying capacity of Top Down prefounded columns on different excavation schedule. When several floors are excavated, the valid buckling length of prefounded column is increased and allowable buckling stress is decreased. The result shows that all columns are safe in buckling down to B3 story whether 2 or 3 stories are excavated. However, several columns are not safe from B4 story when 2 or 3 stories are excavated straightly. With these results, a process can be designed that the first three stories in the basement are excavated, and then excavate B4 story after placing concrete on B1 and B2 floor.

Seismic fragility evaluation of piping system installed in critical structures

  • Ju, Bu Seog;Jung, Woo Young;Ryu, Yong Hee
    • Structural Engineering and Mechanics
    • /
    • v.46 no.3
    • /
    • pp.337-352
    • /
    • 2013
  • Seismic performance of critical facilities has been focused on the structural components over the past decade. However, most earthquake damages were observed to the nonstructural components during and after the earthquakes. The primary objective of this research was to develop the seismic fragility of the piping system incorporating the nonlinear Tee-joint finite element model in the full scale piping configuration installed in critical facilities. The procedure for evaluating fragility curves corresponding to the first damage state was considered the effects of the top floor acceleration sensitivities for 5, 10, 15, and 20 story linear RC and steel building systems subjected to 22 selected ground motions as a function of ground motion uncertainties. The result of this study revealed that the conditional probability of failure of the piping system on the top floor in critical facilities did not increase with increased level of story height and in fact, story level in buildings can tune the fragilities between the building and the piping system.

Numerical Analysis of Heat Flow and Heat Transfer in Flue Channel of Two-Dimensional Ondol Panel Heating System (2차원(次元) 온돌 상난방(床煖房)시스템의 연도내 열유동(熱流動) 및 열전달(熱傳達) 수치해석(數値解析))

  • Kim, Y.D.;Min, M.K.;Lee, S.H.;Kim, W.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.337-343
    • /
    • 1994
  • Numerical analysis was applied to a simplified two-dimensional Ondol heating model which consists of heating space on the top of it along with radiant and convective heating floor panel, flue channel in the midway and rectangular underground soil region at the bottom. These three components constitute a system thermally coupled at the top and bottom interfaces of the flue channel. Investigated in the present paper are effects with variations of the Reynolds numbers of 100, 200, and 300, Grashof numbers of $0.1{\times}10^6$ and $0.3{\times}10^6$ and aspect ratios of 15 and 20 on the heat transfer and fluid flow characteristics of two-dimensional Ondol heating model by computer simulation.

  • PDF

A Study on Crack Reduction Method in open Section of Down-Up Underground Construction Method Affected by Earth Pressure (토압 영향을 받는 Down-Up 지하공사 공법의 오픈 구간 균열 저감 방안 연구)

  • Shim, Hak-Bo;Jeon, Hyun-Soo;Seok, Won-Kyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.196-197
    • /
    • 2021
  • The underground method can be divided into Top-Down, Semi-Top-Down, Up-Up and Down-Up methods according to the construction order of the upper and lower structures. Among them, the Down-Up method proceeds with the construction of the first floor and its lower floors, and when the foundation is completed, the vertical members of the basement are sequentially completed from the foundation and the above-ground floor is constructed. In this paper, the crack reduction method around the open section of the Down-Up method affected by earth pressure was analyzed and divided into design and construction parts.

  • PDF

Comparative Evaluation of Condensation by Type and Layer Around Built-in Furniture of Apartment Buildings (WUFI를 이용한 공동주택 붙박이가구의 층별·형태별 결로 생성 비교 평가)

  • Yoo, Jiwon;Chang, Seong Jin;Lee, Jongki;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.29 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • Recently, as the continuously increasing of the one-person households, builders were focusing on a built-in furniture development for efficiency. Through the dead space of the space can be reduced. Also, Condensation that occurs in a built-in furnitures installation space may result in different results depending on the room's direction, floor, finish, adjacent room effect, occupant's lifestyle. In this background, it can be considered in terms of functional aspect and morphological aspect by using WUFI2D simulation system. As a result, the tendency of occurrence of condensation was examined by comparing the water content and the growth potential of fungus graph which came from WUFI2D. Results of this study are as followings: Built-in furniture, both top & bottom open, is more stable to condensation than the built-in furniture with the top or bottom open. Also, Among from the top floor built-in furniture to the bottom of it, the bottom one is more stable to condensation.

  • PDF

Prediction of Structure-Borne Noise for Floating Floor Using SEA (SEA 기법을 이용한 부유상구조의 구조기인 소음 예측)

  • Park, Hee-Jun;Woo, Kwan-Je
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.258-264
    • /
    • 2007
  • Floating floors, which are mainly used for reducing interior noise levels of railway vehicle, are known to be superior to single structure in respect to sound transmission loss and vibration reduction performances. The stiffness of isolator is one of the important design variables in floating floors. From modal tests, modal properties of underframe, top floor and isolators are derived. They are used as input parameters for predicting structure-borne noise using AUTOSEA.

  • PDF

A Study on the highly efficient ondol system combined the strengthen polyethylene pipe with pulsating heat pipe (강화폴리에스테르튜브(XL 튜브)에 진동형 히트 파이프를 결합한 고성능 난방 패널의 성능에 관한 연구)

  • Kim, Chang-Hee;Kim, Jong-Su;Woo, Jae-Ho;Kong, Sang-Wun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.578-583
    • /
    • 2008
  • Korea which has change of clear season is using unique heater by the name of On-dol being invented since ancient times. Floor-heating device has no radiator, and generates no noise and dust. It can obtain satisfied heating sense than other heating system in low room temperature. And also it is a pleasant system that equals bottom and top temperature in a room. The purpose of this study is to develop the Floor-heating device using pulsating heat pipe. It propose floor-heating device using pulsating heat pipe of the dry process which alternative polyethylene pipe(low XL pipe) that is used widely to existent floor heating system and produce pilot Experiment and analyzed operation condition and performance of most suitable. In this study, main purpose is to develop floor-heating system using pulsating heat pipe by finding an optimum working condition according to changing ratio and evaluating a performance.

  • PDF

Development of Top-Down Connection System to Solve the Problem of Construction Tolerances in Installing Prefabricated Beams to Pre-founded Columns (시공오차가 있는 선기초기둥에 공장제작보의 설치가 용이한 탑다운공사용 접합기술개발)

  • Kim, Seung-Weon;Jung, Hee-Weon;Park, Dae-Yung;Kim, Dong-Gun;Park, Joo-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.25-30
    • /
    • 2011
  • Almost prefounded columns for top-down construction certainly have construction tolerances in plan and plumbness. Therefore, it is very difficult to connect prefabricated beams to prefounded columns at each floor level after excavation by usual top-down connection method and this usual connection method leads to long construction time, increasing cost and decreasing quality. This paper presents a new method for connecting prefabricated beam to prefounded column with GROUT-JACKET CONNECTION SYSTEM consisting of sleeve, bearing-shear bands and grout. Details and illustrations of the connections and applications by GROUT-JACKET CONNECTION SYSTEM for the top-down construction are also included in this paper.

  • PDF

A Study on Construction Sequence Optimization and Structural Analysis in consideration of Structural Concept of Hanging Structure based on the Applied Case (적용사례 중심의 매달린 구조물의 구조적 특성을 고려한 시공순서 최적화 및 시공단계별 구조해석 연구)

  • Park, Yong-Hyeon;Kim, Jong-Soo;Ju, Young-Kyu
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.7
    • /
    • pp.147-156
    • /
    • 2019
  • The purpose of this study is to consider structural issues and analyze construction sequences when constructing hanging floors supported by Mega truss. Since suspended structures were supported by the Mega truss, vertical load on suspended structures was needed to transfer from low to high. Deflection management of structures was the primary point under construction. The results of this study were as follows; The steel structures, which has relatively lighter self-weight, were constructed upwards after the base floor steel truss erection. Concrete Placing, which has relatively heavier self-weight, were performed in two phases to minimize structure's deflection. Slab was placed downwards from the top floor to lower floor whereas column was places upwards. Deflection measurements were carried out at every construction sequences.