• Title/Summary/Keyword: Toothbrush abrasion

Search Result 13, Processing Time 0.03 seconds

A Study on the Toothbrush-Dentifrice Abrasion of Class V Restroations (치경부 5급 와동 수복의 잇솔질 마모에 관한 연구)

  • Hwang, Su-Jin;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.69-81
    • /
    • 2005
  • The objective of this study was to evaluate the toothbrush abrasion characteristics of class V restorations. Thirty extracted human premolars, which were collected from oral surgery clinics were used. We mounted five teeth in a metal ring mold of 50 mm in diameter and 15 mm in height using chemically cured acrylic resin. Class V cavities were prepared in lingual cervical root surfaces and restored using one of following restorative materials : Dentin Conditioner/Fuji II LC (Group FL), All Bond II/Z-250 (Group ZT), One-up Bond F/Palfigue Estelite (Group PE), F2000 Primer/Adhesive (Group FT), and Prime & Bond 2.1/Dyract AP (Group DR). They were stored under distilled water at $37^{\circ}C$ for seven days. The toothbrush abrasion test was conducted using a wear testing machine of pin-on disk type under a load of 1.5 N for 100,000 cycles. We have examined the bonded interfaces, the changes of surface roughness and color of abraded surfaces. From this experiment, the following results were obtained. 1. The change of surface roughness showed high degree: RMGIC>compomer>composite resin (p<0.05). 2. Because of the protrusion and missing of filler particles, SEM observation of abraded surfaces of RMGIC and compomers revealed the increase of surface roughness due to the selective removal of matrix resin. 3. The color change by toothbrush abrasion was affected in large part by the change of $L^*$ and $b^*$ of resin composites (p<0.05). 4. The color change by toothbrush abrasion was so small to detect by human eyes. 5. SEM observation of abraded surfaces revealed the interface bonding was the best in the FT group.

Influence of toothbrush abrasion and surface treatments on the color and translucency of resin infiltrated hybrid ceramics

  • Labban, Nawaf;Al Amri, Mohammad;Alhijji, Saleh;Alnafaiy, Sarah;Alfouzan, Afnan;Iskandar, Mounir;Feitosa, Sabrina
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • PURPOSE. The study compared the color change, lightness, and translucency of hybrid resin ceramics exposed to toothbrush abrasion and surface treatment. MATERIALS AND METHODS. Four hybrid ceramics [Lava Ultimate (LU), Vita Enamic (EN), Shofu HC (SH), and Crystal Ultra (CU)] were compared with a glass-ceramic (Vita Mark II) control. One hundred and twenty specimen blocks were prepared using a precision saw machine. Specimens in each material were divided into four subgroups based on the surface treatment (polishing or staining) and a storage medium (water or citric acid). Simulated tooth brushing with a mixture of 100 RDA (radioactive abrasives) with 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Measurements for the color change, lightness, and translucency were measured after toothbrushing using a spectrophotometer. Statistical analysis compared outcomes using paired t-test, ANOVA, and Tukey post hoc test. RESULTS. The maximum color change was identified in SH (stained acid) [1.44 (0.40)], whereas the lowest was identified in EN (polished water) [0.66 (0.16)] material. The maximum and minimum loss of surface translucency was observed in SH (polished water) [12.3 (0.52)] and EN (stained acid) [6.5 (0.55)] specimens, respectively. Lastly, loss of lightness was the highest in VM (polished acid) [69 (0.95)], whereas the lowest was observed in CU (stained water) [56.7 (0.86)]. CONCLUSION. The comparison presented a significant effect of toothbrush abrasion on translucency and lightness of the hybrid resin ceramics. Color change was not significantly influenced irrespective of the storage medium employed. Surface staining demonstrated the preservation and stability of color and optical properties under the influence of toothbrush abrasion and chemical trauma.

Evaluation of abrasion for non-abrasive denture cleanser

  • Lee, Sang-Min;Min, Ji-Hyun;Choi, Jong-Hoon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.21 no.2
    • /
    • pp.99-107
    • /
    • 2021
  • Objectives: To compare and evaluate the degree of abrasion of the denture base resin according to the type of denture cleansers. Methods: Denture base resin specimens were prepared and dried. The resin specimens were installed in the automatic brushing machine so that the toothbrush weighed 200 g. The brushing was performed 1,000 times each, a total of 10,000 times using (1) distilled water (DW), (2) non-abrasive cleanser (NAC), and (3) toothpaste (TP), respectively. Thirty specimens were allocated for each group. The thickness of abrasion by brushing was calculated by converting the weight of the specimen. Results: In all DW, NAC, and TP groups, significant differences were found in the average amount of abrasion of the resin specimen due to 1,000 to 10,000 brushings (p<0.001). The average abrasion amount of the resin specimen due to brushing 10,000 times was 2.31±1.20 ㎛ in DW group, 2.52±0.25 ㎛ in NAC group, 6.50±0.60 ㎛ in TP group, and the amount of abrasion in the TP group was statistically significant compared to other groups (p<0.001). Conclusions: The use of TP is not recommended as a method for maintaining the longevity of dentures and for oral health, and NAC was considered to be possible to be used as a denture cleanser because it had a similar amount of abrasion of that of DW.

The Effect of Silicone Toothbrush on Plaque Control and Gingival Inflammation. A Comparative Clinical Study (치태제거 및 치은염증에 대한 실리콘 칫솔의 효과)

  • Chung, Yeh-Jin;;Suh, Jong-Jin;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.4
    • /
    • pp.911-923
    • /
    • 2000
  • A comparative clinical study on the ordinary toothbrush($Buttler^{(R)}$, America) and the silicone toothbrush($Jefe^{(R)}$, Korea) was performed. The volunteers who took part in this study were students of Dental college of Yonsei University and patients attending Dental Hospital of Yonsei University. They were classified into two group, control and experimental group. Control group brushed with nylon toothbrush and experimental group did with silicone toothbrush under the researcher's guidances. Volunteers were examined on Plaque Index(PI), Gingival Index(GI), Probing Depth(PD), Bleeding on Probing(BP) and Recession(R) at base line, 1st. week, 2nd. week and 4th. week. According to the results, both group have the tendency of improvement in the degrees of GI, PI and the improvement degree of GI of both group has the significant differences from base line statistically, and there are not statistically significant differences between the silicone and nylon group in respect of PI, GI values. So based on the present study, it could be carefully ascertained that the silicone toothbrush has similar effect with nylon toothbrush in respect of PI and GI. If it is sure that the silicone toothbrush is seldom abrasive and possibly enough to massage the gingiva, this new brush is worth to be recommended by the dentists.

  • PDF

A STUDY ON TOOTHBRUSH ABRASION OF CERVICAL RESTORATIVE MATERIALS (치경부 심미수복재의 잇솔질 마모에 관한 연구)

  • Baik, Byeong-Ju;Yang, Jeong-Sook;Lee, Doo-Cheol;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.118-128
    • /
    • 2001
  • This study was performed to evaluate the toothbrush abrasion characteristics of seven commercially available light-cured cervical restorative materials one resin-modified glass-ionomer material(Fuji II LC) three polyacid-modified composites(Compoglass, Dyract, F2000), and three light-cured composites(Heliomolar, Palpique Estelite, UniFil F). All samples were stored in distilled water at $37^{\circ}C$ for 10 days. 2.0N of weight was loaded during the test and the abraded surfaces were examined with profilometer and SEM after 100,000 cycles. The results obtained were summarized as follows; 1. The highest hardness value of 79.7 was observed in the FT group and the lowest value of 20.0 was observed in the HM group. Results of Tukey test showed that an overall significant difference was indicated except the CG and DR groups(p<0.05). 2. The highest surface roughness was observed in the FL group and the lowest was observed in the UF group. Results of Tukey test showed the significant difference between the FL or FT and UF groups(p<0.05). 3. Statistically higher abrasion and surface roughness were observed for the dentifrice of paste type, Perio A+, than for that of gel paste type, Tom & Jerry. 4. The surface roughness values increased on the abraded surfaces because of the protrusion of filler particles due to selective removal of matrix resin.

  • PDF

EVALUATION ON THE ABRASION RESISTANCE OF A SURFACE SEALANT (레진전색제의 마모저항성에 대한 평가)

  • Kim, Soo-Mee;Han, Sae-Hee;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.180-190
    • /
    • 2007
  • The purpose of this study was to evaluate the abrasion resistance of surface penetrating sealant which was applied on a composite resin restoration and to provide proper time to reapply sealant on composite resin surface. Two hundred rectangular specimens, sized $8\times3\times2mm$, were made of Micronew (Bisco, Inc., Schaumburg, IL, U.S.A) and divided into two groups; F group (n = 10) was finished with coarse and medium grit of Sof-Lex discs and BisCoverwas applied B group (n = 190) after finishing with discs. B group was again subdivided into nineteen subgroups From B-1 group to B-18 group were subjected to toothbrush abrasion test using a distilled water-dentifrice slurry and toothbrush heads B-IM group was not subjected to toothbrush abrasion test. Average surface roughness (Ra) of each group was calculated using a surface roughness tester (Surfcorder MSE-1700: Kosaka Laboratory Ltd., Tokyo, Japan) . A representative specimen of each group was examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using cluster analysis, paired t-test, and repeated measure ANOVA. The results of this study were as follows; 1. Ra off group was $0.898{\pm}0.145{\mu}m$ and B-IM group was $0.289{\pm}0.142{\mu}m$. Ra became higher from B-1 group $(0.299{\pm}0.48{\mu}m$ to B-18 group $(0.642{\pm}0.313{\mu}m$. 2. Final cluster center of Ra was $0.361{\mu}m$ in cluster 1 $(B-IM\simB-7)$, $0.511{\mu}m$ in cluster 2 $(B-8\simB-14)$ and $0.624{\mu}m$ in cluster 3 ($(B-15\simB-18)$. There were significant difference among Ra of three clusters. 3 Ra of B-IM group was decreased 210.72% than Ra of F group. Ra of B-8 group and B-15 group was increased 35.49% and 51.35% respectively than Ra of B-IM group. 4. On FE-SEM, B-IM group showed the smoothest resin surface. B-8 group and B-15 group showed vertically shallow scratches , and wide and irregular vertical scratches on composite resin surface respectively. Within a limitation of this study, finished resin surface will be again smooth and glazy if BisCover would be reapplied within 8 to 14 months after applying to resin surface.

COMPARISON OF THE PHYSICAL PROPERTIES OF FOUR KINDS OF ACRYLIC RESIN DENTURE TEETH (4종 아크릴릭 레진 인공치의 물리적 성질에 관한 비교)

  • Hwang, Jong-Woo;Chung, Chae-Heon;Ko, Yeong-Mu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.210-230
    • /
    • 1995
  • To compare the wear resistance of four kinds of commercial acrylic resin teeth [SR-Orthosit PosterioresR(Ivoclar Co., Liechtenstein), Endura PosteriorR(Shofu Inc. Japan), trubyte IPN teethR(Dentsply International Inc., York,), Trubyte BiotoneR(dentsply Inermational Inc. Brazil) by means of the toothbrush abrasion method, the artificial resin teeth were embedded in epoxy resin with the occlusal surfaces aligned in one plane for a total of 40 blocks. There after, each lock was mounted in the arm of the toothbrush abrasion machine(K 236, Japan). Wear measurements were made on the three preconditioned states. Those were as follows : no treatment specimens, thermocycled specimens, and thermocycled specimens which were immeresed applied load of 400g during the buring the brushing cycle. At the end of the 30,000-stroke cycle, each specimen was removed, and weighed. The microhardness of four kinds of commercial resin teeth were determined by means of microhardness tester. Microhardness tests were performed on te no treatment specimens, thermocycled specimens, and thermocycled specimens with immersion in the denture cleansing solution. Finally, the comparison of thermal properties were perfomed using differential scanning calorimeter(DSC-1500). The following results were obtained : 1. In the case of no treatment teeth, the wear amount of endura Posterior(EN) was the greatest among the others(p<0.01), and the wear amount of three kinds of artificial resin teeth was increased in the order of Trubyte IPN teeth(IN), Trubyte Biotone(BN), SR-Orthosit Posteriores(SN) but there was no statistic significance(p>0.01). 2. The wear amount of Trubyte IPN teeth(IT) and Trubyte Biotone(BT), was increased due to thermocycling effect, but that of Endura Posteriores(ET) was decreased conversely(p<0.01). 3. Except for the SR-Orthosit Posteriores(STC), the wear amount of three kinds of artificial resing teeth(that is, ETC, ITC, BTC) was increased due to denture cleansing solution$(Cledent^R)$, but there was no statistic significance(p>0.01). But the wear amount of the SR-Orthosit Posteriores(STC) was the greatest among the others(p<0.01). 4. The wear amount of toothbrush was the greatest in case of contact with occlusal surface of SROrthosit Posteriores resin teeth(p<0.01). 5. the microhardness values(KHN) of the SR-Orthosit Posteriores was the highest among the experimental artificial resin teeth(p<0.01). 6. There was no relationship between microhardness valuse(KHN) and wear amount of four kinds of experimental artificial resin teeth(p<0.01). 7. The differential canning calorimetric property of four kinds of artificial resin teeth did not show endothermal or exothermal peak in the range of $100^{\circ}C$

  • PDF

The study on toothbrush filaments (칫솔 강모 형태에 관한 연구)

  • Han, Seung-Min;Yang, Seung-Min;Lee, Young-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung;Choi, Sang-Mook;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.4
    • /
    • pp.857-864
    • /
    • 2002
  • The aim of this study is to investigate the end of filaments of the different toothbrushes in the market through the stereomicroscope and to evaluate the % of rounded-end filaments considered to be acceptable. 9 brands, total 11 type toothbrushes were tested. 2 toothbrushes of each type which is marked as rounded-end filaments were tested. The toothbrushes which are not marked as rounded-end filaments were excluded. The domestic as well as foreign toothbrushes which are familiar to consumers were tested. 2 tufts of each toothbrushes were cut and examined by stereomicroscope using $40{\times}$ magnification. The procedure was carried out with blind-technique, and the digital photographs were taken. Besides the % of rounded-end filaments, total tufts number, material of the tuft, stiffness, and other special characteristics were recorded. By the classification of Silverstone and Featherstone, rounded-end filaments were examined and counted. The results shows that there are different range of rounded-end filaments according to the toothbrush types(17.7%-91.2%). Atman toothbrush has the most rounded-end filaments(91.2%) among the observed toothbrushes, and the Advantage Plus(Ora1-B) has the next(86.75%). E-Clean #411 has the least(17.70%) and E-Clean #410 of the same brand has also low % rounded-end filaments(20.60%). While G.U.M #409(Butler) has 67.90% rounded-end filaments, G.U.M #471 of the Same brand has comparative low 41.83% rounded-end filaments. 4 types of total 11 have the rounded-end filaments over 80%, however other 4 types have under even 50%. Considering that the correct brushing habit with a toothbrush which has rounded-end filaments can protect the gingival injury and tooth abrasion, it is thought that we dentists need to give the correct information about toothbrush to the patients

CHARACTERISTICS OF FLUORIDE RELEASING RESTORATIVE MATERIALS AFTER TOOTHBRUSH-DENTIFRICE ABRASION (잇솔질 마모 처리한 불소방출성 수복재의 특성)

  • Park, Jong-Ha;Baik, Byeong-Ju;Yang, Yeon-Mi;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.705-713
    • /
    • 2004
  • The objectives of this study were to evaluate the fluoride release and the change of surface roughness of fluoride releasing restorative materials after toothbrush-dentifrice abrasion. Seven commercially available fluoride releasing restorative materials (Fuji II LC Improved: FL, Compoglass F: CG, Dyract AP: DR, F2000: FT, Ariston: AT, Tetric: TR, and Gradia: GD) were selected as experimental materials. The results obtained were summarized as follows: 1. The AT, FL, and CF groups produce an initially large burst of fluoride release and comparatively low but continuous release of fluoride. But other groups produce no initial burst of fluoride and levels of release remain relatively constant. 2. The rate of fluoride release remains steady state after 40 days. The results of Tukey's test (P<.05), the fluoride release showed the order of decreasing rank as follows: AT > FL > compomers > TC and GD. 3. The surface roughness indicated that the highest value was observed in the FT group and the lowest value was observed in the CF group. The surface roughness of Tukey's test showed the significant differences between groups of FT, AT and FL and groups of CF, DR, GD and TC (P<0.05).

  • PDF

Effect of Ultra-Soft and Soft Toothbrushes on the Removal of Plaque and Tooth Abrasion

  • Jeong, Moon-Jin;Cho, Han-A;Kim, Su-Yeon;Kang, Ka-Rim;Lee, Eun-Bin;Lee, Ye-Ji;Choi, Jung-Hyeon;Kil, Ki-Sung;Lee, Myoung-Hwa;Jeong, Soon-Jeong;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.18 no.3
    • /
    • pp.164-171
    • /
    • 2018
  • To improve the oral health status of Korean people, it is necessary to encourage proper oral hygiene management habits, such as toothbrushing, through appropriate health promotion techniques. Therefore, the purpose of this study was to evaluate the removal of plaque and tooth abrasion using ultra-soft (filament 0.11~0.12 mm) and soft toothbrushes for toothbrushing. The plaque removal was performed using a dentiform and Arti-spray, and the Patient Hygiene Performance (PHP) index was calculated as the sum total score divided by the total number of surfaces. In the abrasivity experiment, according to the number of brushings, a micro Vickers hardness tester was used, and a sample in the range of 280~380 Vickers hardness number was selected. The number of toothbrushing stroke were 1,800 (2 months), 5,400 (6 months), 10,800 (12 months), and 21,600 (24 months). The tooth abrasion was measured using a scanning electron microscope. Statistical analysis was performed using IBM SPSS Statistics 22.0 and a p-value <0.05 was considered significant. According to the results, there was no statistically significant difference in the degree of plaque removal between ultra-soft and soft toothbrushes. The difference in tooth abrasion between before and after toothbrushing was found to be greater with the soft toothbrushes than with the ultra-soft toothbrushes. Therefore, the ultra-soft toothbrush not only lowers tooth damage by reducing tooth abrasion, but also shows a similar ability to remove plaque as soft toothbrushes.