• 제목/요약/키워드: Toothbrush

검색결과 183건 처리시간 0.029초

Effects of an electric toothbrush combined with 3-color light-emitting diodes on antiplaque and bleeding control: a randomized controlled study

  • Kwon, Chakyoung;Lee, Jae-Mok;Suh, Jo-Young;Seo, Seung-Jun;Lee, Youngkyun;Kim, Yong-Gun
    • Journal of Periodontal and Implant Science
    • /
    • 제50권4호
    • /
    • pp.251-259
    • /
    • 2020
  • Purpose: This randomized controlled study aimed to evaluate the effects of an electric toothbrush with 3 colors of light-emitting diodes (LEDs) on antiplaque and bleeding control. Methods: This randomized, placebo-controlled, double-blinded, parallel-group clinical trial included 50 healthy adults with gingivitis, who were randomly assigned to 2 groups. The experimental group used electric toothbrushes with 3 colors of LEDs and the control group used the same electric toothbrush as the experimental group, but with LED sources with one-hundredth of the strength. The subjects used the electric toothbrush 3 times a day for 4 minutes each time. As clinical indices, bleeding on marginal probing (BOMP), the Löe-Silness gingival index (GI), and the Turesky-Quigley-Hein plaque index (QHI) were assessed at baseline, at 3 weeks, and at 6 weeks. Results: There were significant decreases in all clinical indices (BOMP, GI, QHI) in both the experimental and control groups compared to baseline at 3 weeks and at 6 weeks. In a comparison between the experimental and control groups, no statistically significant differences were observed for any clinical indices at 3 weeks (P>0.05). However, at 6 weeks, statistically significant differences were observed between the experimental and control groups in BOMP and GI, which are indicators of gingival inflammation (P<0.05). Conclusions: This study demonstrated that an electric toothbrush combined with 3-color LEDs reduced gingival bleeding and inflammation after 6 weeks.

가정용 칫솔 UV 살균기의 성능 개선법에 관한 연구 (Studies on the improvement of UV sterilizer for toothbrush)

  • 양은정;이미선;김정우
    • 자연과학논문집
    • /
    • 제11권1호
    • /
    • pp.41-44
    • /
    • 1999
  • 가정용 칫솔 UV 멸균기의 성능을 개선 할 목적으로, 먼저 UV 처리에 따른 칫솔의 멸균효과를 알아보기 위한 실험을 하였다. UV를 5분, 15분, 30분, 60분의 여러 시간동안 처리하여 실험한 결과, 유의성 있는 효과는 15분 후에 나타났으며, 그 때 80% 이상의 세균 치사율이 됨을 알 수 있었다. UV에 장시간 노출될 경우 나타나는 플라스틱의 탈색을 예방하기 위하여 15분 UV 처리 후 2시간의 무처리 시간을 주고, 다시 3분을 처리한 결과, 97%의 치사율을 보임을 알 수 있었다. 한편, 멸균기에서 칫솔 위치에 따른 멸균효과는 UV light를 직접적으로 받는 위치의 칫솔에만 국한되어 멸균이 되어 이의 개선점이 제시되었다.

  • PDF

RE-ACCELERATION MODEL FOR THE 'TOOTHBRUSH' RADIO RELIC

  • KANG, HYESUNG
    • 천문학회지
    • /
    • 제49권3호
    • /
    • pp.83-92
    • /
    • 2016
  • The Toothbrush radio relic associated with the merging cluster 1RXS J060303.3 is presumed to be produced by relativistic electrons accelerated at merger-driven shocks. Since the shock Mach number inferred from the observed radio spectral index, Mradio ≈ 2.8, is larger than that estimated from X-ray observations, MX ≲ 1.5, we consider the re-acceleration model in which a weak shock of Ms ≈ 1.2 - 1.5 sweeps through the intracluster plasma with a preshock population of relativistic electrons. We find the models with a power-law momentum spectrum with the slope, s ≈ 4.6, and the cutoff Lorentz factor, γe,c ≈ 7-8×104 can reproduce reasonably well the observed profiles of radio uxes and integrated radio spectrum of the head portion of the Toothbrush relic. This study confirms the strong connection between the ubiquitous presence of fossil relativistic plasma originated from AGNs and the shock-acceleration model of radio relics in the intracluster medium.

자동 위치 검출을 이용한 지능형 칫솔 시스템 개발 (Smart Toothbrush System Development Using Auto Tooth brushing Position Detection)

  • 이강휘;이정환;이영재;김경섭;김동준;윤태호;양희경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1908-1909
    • /
    • 2007
  • The design of an intelligent toothbrush, capable of monitoring brushing motion, orientation through the grip axis, during toothbrushing is described. Inappropriate Toothbrushing styles, even in adults, sometimes cause dental problems, cavities, gingivitis, etc. This smart system provides user to monitor his or her brushing pattern using accelerometer and magnetic sensors for evaluation of toothbrushing style. Directional information of toothbrush with respect to earth's magnetic field and activity data were measured by a miniaturized low-power micro- controller, MSP430 and transmitted to personal computer by 2.4GHz radio transmitter, nRF2401. A personal computer provides an on-line display of activity and orientation measurements during toothbrushing. The signal trace is then analyzed to extract clinically relevant measurement. This preliminary study showed that the proposed monitoring system was conceived to aid dental care personnel in patient education and instruction in oral hygiene regarding brushing style.

  • PDF

미취학 어린이에서 음파 칫솔과 일반 칫솔의 효과 (Effectiveness of Sonic and Manual Toothbrush in Preschool Children)

  • 신영섭;이효설;송제선;이제호
    • 대한소아치과학회지
    • /
    • 제43권4호
    • /
    • pp.374-381
    • /
    • 2016
  • 본 연구의 목적은 $L{\ddot{o}}e$ & Silness의 치태지수를 사용하여 음파 칫솔과 일반 칫솔의 효과를 비교하는 것이다. 연세대학교 치과대학병원 소아치과에 내원한 전신질환이 없는 3-6세 어린이 34명을 대상으로 교차설계, 연구자에 대한 눈가림법을 사용한 무작위 대조군 연구가 진행되었다. 연구 참여자는 2개의 군으로 무작위로 나누어져 음파 칫솔과 일반 칫솔을 번갈아 2주씩 사용하였고, 칫솔질 전후 구강위생상태를 $L{\ddot{o}}e$ & Silness의 치태지수를 사용하여 측정하여 차이를 비교하였다. 음파 칫솔 사용 후 $0.26{\pm}0.28$, 일반 칫솔 사용 후 $0.09{\pm}0.22$의 치태지수 감소를 보였고, 이는 통계학적으로 유의한 차이를 보였다(p < 0.05). 성별과 나이에 따른 음파 칫솔의 치태 제거 효과는 통계학적으로 유의한 차이를 보이지 않았다(p > 0.05). 연구 결과, 3-6세 어린이에서 음파 칫솔이 일반 칫솔에 비해 치태 제거 효과는 좋았고, 성별과 연령에 따른 치태 제거 효과의 차이는 나타나지 않았다.

체스형의 칫솔모 형태가 치태 및 치은염, 치주낭에 미치는 영향 (The effect of newly designed toothbrush on plaque control, treatment of gingivitis and periodontitis)

  • 채중규;신철우;서종진;최성호;조규성;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제29권1호
    • /
    • pp.131-139
    • /
    • 1999
  • The present study investigate the effect of newly designed toothbrush(Chess tip : experimental group), conventional toothbrush(control group) on plaque control, gingivitis, and periodontitis. The results of 4weeks post-research by clinical comparison between the two groups are as follows. 1. In analysis of plaque index between groups there was Significant difference in the experimental group at 2,4 week. 2. In analysis of gingival index between groups there was significant difference in the experimental group at 1,2,4 week. 3. Both experimental group and control group showed decrease in periodontal pocket depth after 4week, but there was significant difference in the experimental group at 4 week. 4. Both experimental group and control group showed decrease in bleeding on probing after 4week, but there was significant difference in the experimental group at 4 week. These results indicate that newly designed toothbrush has beneficial effects as additional aid of mechanical treatment at the point of periodontal pocket, plaque control, and bleeding on probing.

  • PDF

The effect of pretreating resorbable blast media titanium discs with an ultrasonic scaler or toothbrush on the bacterial removal efficiency of brushing

  • Koh, Minchul;Park, Jun-Beom;Jang, Yun-Ji;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • 제43권6호
    • /
    • pp.301-307
    • /
    • 2013
  • Purpose: This in vitro study was performed to assess the adherence of Porphyromonas gingivalis to a resorbable blast media (RBM) titanium surface pretreated with an ultrasonic scaler or toothbrush and to evaluate the effects of the treatment of the RBM titanium discs on the bacterial removal efficiency of brushing by crystal violet assay and scanning electron microscopy. Methods: RBM titanium discs were pretreated with one of several ultrasonic scaler tips or cleaned with a toothbrush. Then the titanium discs were incubated with P. gingivalis and the quantity of adherent bacteria was compared. The disc surfaces incubated with bacteria were brushed with a toothbrush with dentifrice. Bacteria remaining on the disc surfaces were quantified. Results: A change in morphology of the surface of the RBM titanium discs after different treatments was noted. There were no significant differences in the adherence of bacteria on the pretreated discs according to the treatment modality. Pretreatment with various instruments did not produce significant differences in the bacterial removal efficiency of brushing with dentifrice. Conclusions: Within the limits of this study, various types of mechanical instrumentation were shown to cause mechanical changes on the RBM titanium surface but did not show a significant influence on the adherence of bacteria and removal efficiency of brushing.

전동칫솔모의 작동형태에 따른 치면세균막 제거율에 관한 실험연구 (An experimental study on plaque removal effect through the acting types of the electric toothbrushes)

  • 이천희;안선하;장영호
    • 한국치위생학회지
    • /
    • 제11권4호
    • /
    • pp.465-474
    • /
    • 2011
  • Objectives : The removal of most reliable mechanical dental plaque that is to say tooth brushing was generalized to control of dental plaque, many oral health goods have also developed due to the effect differences followed by individual habit. The electric toothbrush have studied and developed widely as major field of study that electric toothbrush having various moving phase was sold and developed at the market. Methods : Accordingly author studied about selling electric toothbrushes shape (vibration type, ultra-sonic minuteness vibration type, semi rotation type) to raise the efficiency after comparing to the moving them that total 8 groups classified by poor tooth models for example normal set of tooth, crowding tooth, bracket attached tooth, prosthetic status etc. and executed plaque removal effect on the tooth through comparing experiment. Results : The removal rate of artificial plaque on the tooth was improved in proportion to the increase of tooth brushing time(p<0.05). The ultra-sonic minuteness vibration and semi rotation type was superior to toothbrush of vibration type comparing to the removal rate of plaque on the tooth(p<0.05). Conclusions : The electric toothbrush of supersonic minuteness vibration and semi rotation type can be recommended most of tooth types regardless of oral tooth setting status for example, normal set of tooth, crowding tooth, bracket attached tooth, porcelain tooth.

Influence of toothbrush abrasion and surface treatments on the color and translucency of resin infiltrated hybrid ceramics

  • Labban, Nawaf;Al Amri, Mohammad;Alhijji, Saleh;Alnafaiy, Sarah;Alfouzan, Afnan;Iskandar, Mounir;Feitosa, Sabrina
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.1-11
    • /
    • 2021
  • PURPOSE. The study compared the color change, lightness, and translucency of hybrid resin ceramics exposed to toothbrush abrasion and surface treatment. MATERIALS AND METHODS. Four hybrid ceramics [Lava Ultimate (LU), Vita Enamic (EN), Shofu HC (SH), and Crystal Ultra (CU)] were compared with a glass-ceramic (Vita Mark II) control. One hundred and twenty specimen blocks were prepared using a precision saw machine. Specimens in each material were divided into four subgroups based on the surface treatment (polishing or staining) and a storage medium (water or citric acid). Simulated tooth brushing with a mixture of 100 RDA (radioactive abrasives) with 0.3 ml distilled water was used for 3650 cycles (7300 strokes) for each specimen. Measurements for the color change, lightness, and translucency were measured after toothbrushing using a spectrophotometer. Statistical analysis compared outcomes using paired t-test, ANOVA, and Tukey post hoc test. RESULTS. The maximum color change was identified in SH (stained acid) [1.44 (0.40)], whereas the lowest was identified in EN (polished water) [0.66 (0.16)] material. The maximum and minimum loss of surface translucency was observed in SH (polished water) [12.3 (0.52)] and EN (stained acid) [6.5 (0.55)] specimens, respectively. Lastly, loss of lightness was the highest in VM (polished acid) [69 (0.95)], whereas the lowest was observed in CU (stained water) [56.7 (0.86)]. CONCLUSION. The comparison presented a significant effect of toothbrush abrasion on translucency and lightness of the hybrid resin ceramics. Color change was not significantly influenced irrespective of the storage medium employed. Surface staining demonstrated the preservation and stability of color and optical properties under the influence of toothbrush abrasion and chemical trauma.

Effect of 125 Hz and 150 Hz vibrational frequency electric toothbrushes on the rate of orthodontic tooth movement and prostaglandin E2 levels

  • Anadha N. Gujar;Prashantha Govinakovi Shivamurthy
    • 대한치과교정학회지
    • /
    • 제53권5호
    • /
    • pp.307-316
    • /
    • 2023
  • Objective: To evaluate the effects of an electric toothbrush with vibrational frequencies of 125 Hz and 150 Hz on the orthodontic tooth movement (OTM) rate and the production of prostaglandin E2 (PGE2). Methods: Out of thirty patients (aged 18-25 years; 16 females and 14 males), ten patients each formed Group A and B, who used electric toothbrushes with 125 Hz and 150 Hz vibrations, respectively. The remaining ten patients (Group C) served as the control group and did not use electric toothbrushes. The rate of OTM and levels of PGE2 using microcapillary pipettes were calculated before the start of retraction (T0), on the 30th day (T1), on the 60th day (T2), and on the 90th day (T3) from the start of retraction in all the groups. Results: There was a statistically significant difference in the mean OTM values and PGE2 levels in all three groups at different time intervals, with the maximum difference seen in Group B compared to Group A and least in Group C at T1, T2 and T3. Conclusions: The rate of OTM and levels of PGE2 were highest in patients who used an electric toothbrush with 150 Hz mechanical vibration compared to those who used an electric toothbrush with 125 Hz mechanical vibration and least in patients who did not use an electric toothbrush. Mechanical vibration led to an increase in the PGE2 levels and accelerated the OTM.