• Title/Summary/Keyword: Tooth number

Search Result 583, Processing Time 0.029 seconds

Investigation of the Distance from One Tooth Center to Adjacent Tooth Center and Dental Arch Size to Develope New Removable Die System for Fabrication of Dental Prosthetic Appliance (치과보철물 제조용 모형 조립체(가철식 치형 시스템) 개발을 위한 인접 치아 중심 간격 및 악궁 크기 조사)

  • Kim, Bu-Sob;Ma, Seung-Ho;Jeong, Kyung-Mok;Byun, Tae-Hee
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.151-161
    • /
    • 2007
  • To obtain the information of dental arch size and the distance from one tooth center to adjacent tooth center of occlusal surface of each tooth which is perforated by Pindex system on working cast for removable die system, 600 dental casts in Busan were examined. The distance of center of occlusal surface of each tooth and dental arch size were digitized. The results were as follows; 1. Mean values of the distance from center of maxillary central incisor to maxillary lateral incisor(tooth number 11$\sim$12, 21$\sim$22) is 5,7 mm, 12$\sim$13(22$\sim$23) is 5.9 mm, 13$\sim$14(23$\sim$24) is 6.9 mm, 14$\sim$15(24$\sim$25) is 7.1 mm, 15$\sim$16(25$\sim$26) is 8.4 mm, 16$\sim$17(26$\sim$27) is 10.2 mm, 11$\sim$21 is 7.30 mm. Mean values of the distance from center of mandibular central incisor to mandibular lateral incisor(tooth number 31$\sim$32, 41$\sim$42) is 4.5 mm, 32$\sim$33(42$\sim$43) is 4.8 mm, 33$\sim$34(43$\sim$44) is 6.3 mm, 34$\sim$35(44$\sim$45) is 7.2 mm, 35$\sim$36(45$\sim$46) is 9.2 mm, 36$\sim$37(46$\sim$47) is 10.7 mm, 31$\sim$41 is 4.7 mm. 2. Mean values of the distance from the center of maxillary right central incisor to the center of maxillary left central incisor(11$\sim$21) is 7.3 mm, 12$\sim$22 is 18.2 mm, 13$\sim$23 is 26.9 mm, 14$\sim$24 is 37.2 mm, 15$\sim$25 is 43.2 mm, 16$\sim$26 is 48.5 mm, 17$\sim$27 is 53.5 mm. Mean values of the distance from the center of mandibular right central incisor to the center of mandibular left central incisor(31$\sim$41) is 4.7 mm, 32$\sim$42 is 13.3 mm, 33$\sim$43 is 21.7 mm, 34$\sim$44 is 31.9 mm, 35$\sim$45 is 38.2 mm, 36$\sim$46 is 44.8 mm, 37$\sim$47 is 50.7 mm. 3. Mean values of the distance from the line of between 11$\sim$21 to 12$\sim$22 is 10.9 mm, 12$\sim$22 to 13$\sim$23 is 8.7 mm, 13$\sim$23 to 14$\sim$24 is 10.3 mm, 14$\sim$24 to 15$\sim$25 is 6.0 mm, 15$\sim$25 to 16$\sim$26 is 5.3 mm, 16$\sim$26 to 17$\sim$27 is 5.0 mm. 31$\sim$41 to 32$\sim$42 is 8.6 mm, 32$\sim$42 to 33$\sim$43 is 8.4 mm, 33$\sim$43 to 34$\sim$44 is 10.2 mm, 34$\sim$44 to 35$\sim$45 is 6.3 mm, 35$\sim$45 to 36$\sim$46 is 6.6 mm, 36$\sim$46 to 37$\sim$47 is 5.9 mm. 4. We checked the bottom side of cast to verify the position of dowel pin. There is no difference upper side and lower side.

  • PDF

Cogging Torque and Acoustic Noise Reduction in High Torque BLDC Motors by Teeth Pairings (고정자 잇날 페어링을 이용한 고출력 토크 BLDC 전동기의 코깅 토크 및 소음 저감)

  • Lee, Sang-Min;Hwang, Sang-Mun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.3
    • /
    • pp.97-103
    • /
    • 1999
  • This paper investigates reduction of acoustic noise and cogging torque in a BLDC motor with larger stator slot open width. Using energy method, cogging torque is analytically determined with airgap MMF function and airgap permeance function and confirmed by FEM analysis. It shows that the cogging torque is firstly governed by NL GNL BNL with the fundamental period of NL, where NL is the least common multiple of the number of slots and the number of poles, GNL, airgap permeance function and BNL, airgap MMF function. It also shows that there exist several tooth width which minimizes the cogging torque, for the motors that smaller slot open width or stator teeth notching is not available. And it proposes a teeth pairing with two different tooth width which can effectively eliminate the cogging torque and thus the acoustic noise. Experimental results show that the proposed teeth pairing reduces the cogging torque by 85% and the acoustic noise by 3.1dB.

  • PDF

Factors that influence the oral health status between Korean adults living in Korea and the US (재미 한국인과 우리나라 성인의 구강건강상태에 영향을 미치는 요인에 관한 연구)

  • Kim, Youn-Hwa
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.4
    • /
    • pp.597-604
    • /
    • 2013
  • Objectives : The purpose of the study is to compare and investigate oral health status between Korean adults living in Korea and the US. Methods : Subjects were 1,785 persons including 399 Korean adults living in Virginia, US and those from the second year 2011 of the 5th National Health and Nutrition Survey. Darta were analyzed using SPSS 12.0 for frequency analysis, t-test, one-way ANOVA, and post-hoc Tukey. Results : 1. In general characteristics, adult living in Korea revealed higher DT and DMFT than those in the US. 2. In oral health status, adult living in Korea revealed higher DT and DMFT than those in the US. 3. The variables affecting oral health status in Korean adults in the US were age, private health insurance and number of tooth brushing. 4. The variables affecting oral health status in adults in Korea included gender, age, private health insurance, smoking, drinking, use of secondary oral hygienic products and number of tooth brushing. Conclusions : It is necessary to emphasize the importance of oral health care and to establish the oral health education in dental care agencies.

A Study on the Magnetic Circuit Design and Control Method of 2-Phase 8-Pole PM Type Linear Pulse Motor (2상(相)8극영구자석형(極永久磁石形) LPM의 자기회로설계(磁氣回路設計)와 제어방식(制御方式)에 관한 연구(硏究))

  • Kim, Il-Jung;Lee, Eun-Woong;Lee, Min-Myeong;Lee, Myeong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.47-50
    • /
    • 1991
  • LPM(Linear Pulse Motor) provide direct and precise position control of bidirectional linear motion. LPM is not subject to the same linear velocity and acceleration limitations inherent in systems converting rotary to linear motion such as lead screws, rack and pinion, belt and pulley drives. With LPM, all the thrust force generated by the motor is efficiently applied directly to the load. And speed, distance, and acceleration are easily programmed in a highly repeatable fashion. Potential industrial and application fields of LPM include PCB assembly, industrial sewing machines, automatic inspection, coil winder, medical uses, conveyer system, laser cut and trim systems, semiconductor wafer processing, OA instruments etc. This paper describes various design parameter of LPM such as magnetic ciucuit construction methods, phase number and tooth number per pole, permanent magnet and coil mmf, tooth geometries. And to solve the problems of existing control methods, in this paper, a new control method of the LPM is proposed throughout modern control theory.

  • PDF

The Study on the Composition of the Encoder for Driving the High Speed Spindle Motor (고속 스핀들 전동기 구동을 위한 자기식 엔코더 구성에 관한 연구)

  • Choi Cheol;Kim Cheol-U;Lee Sang-Hun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.5
    • /
    • pp.253-259
    • /
    • 2005
  • Magnetic encoder with relatively low pulse per rotation is generally used for detecting speed of the high-speed rotating machine. It is due to the fact of the mechanical problems of vibration and bearing stiffness and also the limit of maximum output pulse of the mounted encoder. The magnetic encoder is divided into two types, that is, toothed gear-wheel method and magnetic wheel method according to the shape of the rotation disk. In case of detecting speed by the tooth gear-wheel, the encoder itself can be acted as the additional inertia where the number of tooth determining the output pulse and the width of the wheel detecting the change of the magnetic flux density are relatively enough large considering the volume of the rotating machine. While the magnetic wheel method has the limit of the magnetizing number of the ring magnet, there is relatively few, if nv, the influence of inertia on the machine. In this paper, it is proposed a simple magnetic wheel encoder suited for the high speed rotating machine and the method of signal processing and the output characteristics are examined through the V/F operation of max 48,000(rpm) and 2.4(KW) spindle motor.

Flavonoids as a Possible Preventive of Dental Plaque

  • Ammar-Nagwa;El, Diwany-Ahmed;Nagwa-Osman;Soheir-Gaafar;Nagwa-Amin
    • Archives of Pharmacal Research
    • /
    • v.13 no.2
    • /
    • pp.211-213
    • /
    • 1990
  • To test flavonoids for antibacterial activity against oral micraorganisms, flavonoids, quercetrin and naringenin, were incorporated into two pharmaceutical preparations in the form of tooth paste. Samplees of dental plaque, the msot accused dental deposit which initiates the gingival and periodental diseases, were collected from the teeth surface of ten dental students at one week interval before and after using placebo, followed by two formulae of tooth paste containing 0.1% of quercetrin and naringenin (formulas I and II, respectively). The amount of dental plaque was assessed by the quigley and Hens index. Then plaque samples were subjected to bacteriological examination of Gram stain and plate counts of microorganisms. The amount of dental plaque was assessed by the Quigley and Hens index. Then plaque samples were subjected to bacteriological examination of Gram stain and plate counts of microorganisms. The results revealed that most of Gram negative cocci and bacilli were highly affected by the two formulae : the number of actinomycetes were decreased after using formula I and disappeared completely by the sue of formula II, while the number of Gram positive streptococci was highly decreased after the treatment with the two formulae. These results indicate a possible use of flavonoids to inhibit dental plaque formation.

  • PDF

Design and Feasibility Study of Double Gerotor (이중 제로터의 설계 및 응용 가능성에 대한 연구)

  • Lee, Sung-chul
    • Tribology and Lubricants
    • /
    • v.35 no.4
    • /
    • pp.215-221
    • /
    • 2019
  • A gerotor set consists of two elements, an inner rotor and an outer rotor. The outer rotor has one more tooth than the inner rotor and has its centerline positioned at a fixed eccentricity from the centerline of the inner rotor. Although gerotors come in a variety of geometric configurations, all gerotor sets share the basic principle of having generated tooth profiles that provide continuous tight sealing during operation. The size of the gerotor is proportional to the number of teeth and the amount of eccentricity. The interior of an inner rotor with a large number of teeth has an enough space to include other machine elements. In this paper, the double gerotor mechanism, constructed by putting a small gerotor in the interior of a large inner rotor, is conceptualized. The double gerotor set is composed of an inner rotor, a planetary rotor, and an outer rotor. The inside profile of the planetary rotor corresponds to the outer rotor profile of the small gerotor, and the outside profile is the inner rotor profile of the large gerotor. In the double gerotor, the centers of the inner and the outer rotor are coincident because the eccentricities of two gerotors are balanced. The operation of a double gerotor is examined by analyzing the planetary motion, and a feasibility study for application of the double gerotor for hydraulic motors and pumps is performed. The double gerotor set has much application potential as a component of hydraulic systems.

Prediction of medication-related osteonecrosis of the jaw (MRONJ) using automated machine learning in patients with osteoporosis associated with dental extraction and implantation: a retrospective study

  • Da Woon Kwack;Sung Min Park
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.3
    • /
    • pp.135-141
    • /
    • 2023
  • Objectives: This study aimed to develop and validate machine learning (ML) models using H2O-AutoML, an automated ML program, for predicting medication-related osteonecrosis of the jaw (MRONJ) in patients with osteoporosis undergoing tooth extraction or implantation. Patients and Methods: We conducted a retrospective chart review of 340 patients who visited Dankook University Dental Hospital between January 2019 and June 2022 who met the following inclusion criteria: female, age ≥55 years, osteoporosis treated with antiresorptive therapy, and recent dental extraction or implantation. We considered medication administration and duration, demographics, and systemic factors (age and medical history). Local factors, such as surgical method, number of operated teeth, and operation area, were also included. Six algorithms were used to generate the MRONJ prediction model. Results: Gradient boosting demonstrated the best diagnostic accuracy, with an area under the receiver operating characteristic curve (AUC) of 0.8283. Validation with the test dataset yielded a stable AUC of 0.7526. Variable importance analysis identified duration of medication as the most important variable, followed by age, number of teeth operated, and operation site. Conclusion: ML models can help predict MRONJ occurrence in patients with osteoporosis undergoing tooth extraction or implantation based on questionnaire data acquired at the first visit.

A CLINICAL STUDY ON THE EMERGENCY PATIENTS OF ORAL AND MAXILLOFACIAL SURGERY DURING RECENT 5 YEARS (최근 5년간 응급실을 내원한 구강악안면외과 환자에 대한 임상적 연구)

  • Kim, Jong-Ryoul;Chung, In-Kyo;Yang, Dong-Kyu;Park, Bong-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.2
    • /
    • pp.155-162
    • /
    • 2001
  • This is a clinical study on patients who had visitied the Emergency Room of Pusan National University Hospital and then been treated in the Department of Oral and Maxillofacial Surgery during recent 5 years, from 1992 to 1996. The results were as follow ; 1. The total number of patients was 2,680 and the ratio of male to female was 1.96:1, The highest monthly incidence was shown in September(12.1%) and October(10.5%) and the age distribution peaks was the third decade(24.3%), followed by the first(23.1%) and the fourth decade(17.2%). 2. Soft tissue injury group(29.1%) was the most prevalent, followed by tooth injury group(16.1%), facial bone injury group (16.0%), toothache group(11.2%), socket bleeding group(11.1%), infection group(9.8%) and TMJ dislocation group(5.9%). 3. The percentage of in-patients and out-patient were 21.6% and 78.4%, respectively. The frequent causes of admission were facial bone fracture(73.8%), infection(20.8%) and soft tissue injury(4.8%) in order. However, soft tissue injury was the most frequent cause in out-patient, followed by tooth injury(20.5%), toothache(14.3%), socket bleeding(14.2%) and TMJ dislocation(7.6%). 4. In the facial bone injury group, the mandibular fractures(70.6%) showed the highest incidence, followed by zygomatic bone and arch fractures(7.5%), maxillary bone fractures(4.0%) and nasal bone fractures(4.0%). 5. In the mandibular bone fracture, the most common location was symphysis(36.7%), followed by the mandibular angles(33.1%) and the condyles(21.8%). 6. The common causes of facial bone fractures were violence, fall and traffic accident in order. 7. The common causes of soft tissue injury were fall down, fight and traffic accident in order and the highest incidence was observed in infants before the age of 10 years(44.0%). 8. In the group of tooth injury, tooth luxation(38.5%) showed the highest incidence followed by tooth fracture(33.2%) and tooth loss(17.1%). The common causes of tooth injury were fall, fight and traffic accident in order. 9. In infected patients group, the ratio of in-patients to out-patients was 1 : 1.28, Buccal(24,7%) and infraorbital space abscess(23.3%) showed the highest incidence. 10. The pain caused by dental caries(39.0%) and pericoronitis(26.6%) showed high incidence in the toothache group. 11. The high incidence was observed during third(34.0%) and fourth (24.5%) decades in TMJ dislocation group. 12. In the group of socket bleeding patients, 92% was post-operative hemorrhage and 8% was accompanied with other systemic hemorrhagic diseases.

  • PDF

THE DIAGNOSIS OF IMPACTED MAXILLARY MESIODENS USING 3-DIMENSIONAL COMPUTED TOMOGRAPHY : A CASE REPORT (3차원 전산화 단층촬영을 이용한 상악 정중 과잉치의 진단)

  • Hong, Young-Woo;Kim, Seong-Oh;Sohn, Hyung-Kyu;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.549-554
    • /
    • 1998
  • The prevalence of the supernumerary tooth is $1{\sim}4%$. It usually occurs in the permanent dentition. It frequently occurs in the maxillary mid palatal area. The presence of the supernumerary tooth causes the following problems ; (1) interfering the eruption of successional tooth, (2) displacing the neighboring teeth, (3) resulting large diastema, (4) forming cystic change. So the supernumerary tooth should be removed as soon as possible. To extract the supernumerary tooth, the exact position must be noticed first. Radiographic techniques that were used in the past are tube shift technique, right angle technique, sterioradiography, using radiopaque contrast media and conventional tomography. But these methods include the subjective opinion of the operator. So, a technique eliminating the operator's opinion and showing the position 3-dimentionally can be used. 3-dimentional computed tomography equipped with dental softwares can show the position of the impacted supernumerally tooth in 3-dimentional position. It has an advantage to eliminate the subjective opinion of the operator. With a fast computer this techenique is done in a relatively short period of time. The rationale of this methods is relatively simple. After tacking X-ray and reconstructing the data 3-dimentionally, sequential removal of the soft tissue and hard tissue(bone) CT number leaves the teeth alone in 3-dimentional position. The image can be seen from anywhere, so the operator can see the image in front, rear, upper, and lower positions. In both cases 1 and 2, the position of the impacted supernumerary tooth is viewed by the 3-dimensional computed tomography. And it made the operator easy to figureout the exact position.

  • PDF