• Title/Summary/Keyword: Tooth fractures

Search Result 98, Processing Time 0.029 seconds

A CLINICAL AND STATISTICAL STUDY OF MANDIBULAR FRACTURES (하악골 골절의 임상통계학적 연구)

  • Park, Jun-Ho;Heo, Nam-Oh;Jeon, In-Seong;Shin, Myoung-Sang;Rho, Young-Seo;Yoon, Kyu-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.3
    • /
    • pp.281-289
    • /
    • 1994
  • This is a clinical study on 235 inpatients who sustained a total of 350 mandibular fractures and who were treated in our department during the period of Oug., 1989 through Dec., 1993. The results obtained are as follows : 1. The mumber of patients has not been increased year after year. In respect of incidence, there were the highest frequency as 67 patients(28.5%) in 1991 and the least frequency as 16 patients(6.8%) in 1989 and the highest frequency as 28 patients(11.9%) in October and the least frequncy as 12 patients(5.2%) in February. 2. The age frequency was the highest in the second decade(30.6%). The youngest patient was 8 months and the eldest patient was 80 years and mean age was 27.8 years. The ratio of men to Wemen was 4 : 1. 3. The most frequent cause was fall down as 86 patients(36.6%) and the next was fist blow 4 as 75 patients(31.9%), traffic accident as 56 patients(23.9%) in order. 4. The most common location was symphysis as 141 numbers(40.3%) and the next was condyle as 96 numbers(27.4%), angle as 94 numbers(26.8%), body as 14 numbers(4.0%) in order. The sum of fracture sites were 350 and there were 1.49 fracture sites per one patient and multiple fractures occured in 100 patients(40.5%) of the 235 patients. The ratio of Left to Right except for symphysis was 1.71 : 1. 5. Among the 333 associated injuries, facial laceration was 136(57.9%) and tooth injury was 58(24.7%) and extremity was 31(13.2%). 6. Among the 350 mandibular fractures, complications after treatment occured in 51(14.6%) and infection as 20(5.7%) was the most frequent complication. 7. In respect of treatment of mandibular fracture, close reduction was 64 patients(27.2%) and open reduction was 164 patients(69.8%) and other were 7 patients(3.0%) of all and so open reduction was the most common in type of treatment.

  • PDF

ESTHETIC RESTORATION OF FRACTURED IMMATURE PERMANENT INCISORS (파절된 미성숙 영구 전치의 수복)

  • Lee, In-Young;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Sun-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.126-132
    • /
    • 2009
  • Injuries of permanent teeth by trauma occur frequently in childhood and adolescence. Crown fractures are as frequent as 25-76% and especially maxillary incisors are prone to fractures. There have been numerous efforts to achieve both aesthetically and functionally satisfying restoration. When a mature tooth is fractured, porcelain crown or laminate veneer could be a choice of prosthodontic treatment. However, in a case of immature permanent incisor fracture, prosthodontic treatment is more complicated due to the immaturity of the tooth. Moreover, if endodontic treatment is accompanied with the prosthodontic treatment, the treatment period is prolonged. In the past, restoration using an orthodontic band, a ready-made crown, or glass ionomer cement did not exhibit esthetically satisfying result. As restorational materials have been improved, now more esthetic restoration is possible by reattaching fractured fragments or light-curing composite resin restoration. We reports cases of patients with fractured maxillary incisors and their successful treatment results through reattachment of fractured fragments and composite resin restoration.

  • PDF

TREATMENT OF HORIZONTAL AND VERTICAL ROOT FRACTURE IN IMMATURE PERMANENT TEETH - A CASE REPORT (미성숙 치근의 수직 파절과 수평 파절의 치험례)

  • Song, Seung-Ho;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.92-97
    • /
    • 2004
  • Traumatic injuries in the young peranent dentition are common, but root fractures, defined as fractures in volving dentin, cementum and pulp, are relatively uncommon. Case 1 is a 9-year-old boy who had a horizontal root fracture of his maxillary right central incisor in the apical third. Root canal therapy was performed in coronal segment and calcium hydroxide therapy was initiated. Six months after treatment, a periapical radiograph showed calcific tissue formation and normal root development. 1 year and 3 months later, the canal was permanently obturated with gutta-percha. Case 2 is a 7-year-old girl who had a vertical root fracture of her maxillary right central incisor. Fractured tooth was intentionally extracted atraumatically, and then the separated fragments are bonded with resin cement. the restored tooth was replanted into the original socket. Recalls up to 8 months showed normal mobility and no periapical pathosis. In these cases, we performed conservative treatment. Clinical and radiographic examination showed no pathosis or abnormality of the teeth and periodontal tissue.

  • PDF

Comparison of high-resolution and standard zoom imaging modes in cone beam computed tomography for detection of longitudinal root fracture: An in vitro study

  • Taramsari, Mehran;Kajan, Zahra Dalili;Bashirzadeh, Parinaz;Salamat, Fatemeh
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.171-177
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the efficacy of two imaging modes in a cone beam computed tomography (CBCT) system in detecting root fracture in endodontically-treated teeth with fiber posts or screw posts by selecting two fields of view. Materials and Methods: In this study, 78 endodontically-treated single canal premolars were included. A post space was created in all of them. Then the teeth were randomly set in one of 6 artificial dental arches. In 39 of the 78 teeth set in the 6 dental arches, a root fracture was intentionally created. Next, a fiber post and a screw post were cemented into 26 teeth having equal the root fractures. High resolution (HiRes) and standard zoom images were provided by a CBCT device. Upon considering the reconstructed images, two observers in agreement with each other confirmed the presence or absence of root fracture. A McNemar test was used for comparing the results of the two modes. Results: The frequency of making a correct diagnosis using the HiRes zoom imaging mode was 71.8% and in standard zoom was 59%. The overall sensitivity and specificity in diagnosing root fracture in the HiRes mode were 71.79% and 46.15% and in the standard zoom modes were 58.97% and 33.33%, respectively. Conclusion: There were no significant differences between the diagnostic values of the two imaging modes used in the diagnosis of root fracture or in the presence of root canal restorations. In both modes, the most true-positive results were reported in the post space group.

Influence of voxel size on cone-beam computed tomography-based detection of vertical root fractures in the presence of intracanal metallic posts

  • Yamamoto-Silva, Fernanda Paula;de Oliveira Siqueira, Claudeir Felipe;Silva, Maria Alves Garcia Santos;Fonseca, Rodrigo Borges;Santos, Ananda Amaral;Estrela, Carlos;de Freitas Silva, Brunno Santos
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.177-184
    • /
    • 2018
  • Purpose: This study was performed to evaluate the influence of voxel size and the accuracy of 2 cone-beam computed tomography (CBCT) systems in the detection of vertical root fracture (VRF) in the presence of intracanal metallic posts. Materials and Methods: Thirty uniradicular extracted human teeth were selected and randomly divided into 2 groups(VRF group, n=15; and control group, n=15). The VRFs were induced by an Instron machine, and metallic posts were placed in both groups. The scans were acquired by CBCT with 4 different voxel sizes: 0.1 mm and 0.16 mm (for the Eagle 3D V-Beam system) and 0.125 mm and 0.2 mm (for the i-CAT system) (protocols 1, 2, 3, and 4, respectively). Interobserver and intraobserver agreement was assessed using the Cohen kappa test. Sensitivity and specificity were evaluated and receiver operating characteristic analysis was performed. Results: The intraobserver coefficients indicated good (0.71) to very good (0.83) agreement, and the interobserver coefficients indicated moderate (0.57) to very good (0.80) agreement. In respect to the relationship between sensitivity and specificity, a statistically significant difference was found between protocols 1 (positive predictive value: 0.710, negative predictive value: 0.724) and 3 (positive predictive value: 0.727, negative predictive value: 0.632) (P<.05). The least interference due to artifact formation was observed using protocol 2. Conclusion: Protocols with a smaller voxel size and field of view seemed to favor the detection of VRF in teeth with intracanal metallic posts.

Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: An in vitro study

  • Nikbin, Ava;Kajan, Zahra Dalili;Taramsari, Mehran;Khosravifard, Negar
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.245-254
    • /
    • 2018
  • Purpose: To assess the effects of object position in the field of view (FOV) and application of a metal artifact reduction (MAR) algorithm on the diagnostic accuracy of cone-beam computed tomography (CBCT) for the detection of vertical root fractures(VRFs). Materials and Methods: Sixty human single-canal premolars received root canal treatment. VRFs were induced in 30 endodontically treated teeth. The teeth were then divided into 4 groups, with 2 groups receiving metal posts and the remaining 2 only having an empty post space. The roots from different groups were mounted in a phantom made of cow rib bone, and CBCT scans were obtained for the 4 different groups. Three observers evaluated the images independently. Results: The highest frequency of correct diagnoses of VRFs was obtained with the object positioned centrally in the FOV, using the MAR algorithm. Peripheral positioning of the object without the MAR algorithm yielded the highest sensitivity for the first observer (66.7%). For the second and third observers, a central position improved sensitivity, with or without the MAR algorithm. In the presence of metal posts, central positioning of the object in the FOV significantly increased the diagnostic sensitivity and accuracy compared to peripheral positioning. Conclusion: Diagnostic accuracy was higher with central positioning than with peripheral positioning, irrespective of whether the MAR algorithm was applied. However, the effect of the MAR algorithm was more significant with central positioning than with peripheral positioning of the object in the FOV. The clinical experience and expertise of the observers may serve as a confounder in this respect.

Dentinal defects induced by 6 different endodontic files when used for oval root canals: an in vitro comparative study

  • Pawar, Ajinkya M;Thakur, Bhagyashree;Kfir, Anda;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.31.1-31.9
    • /
    • 2019
  • Objectives: To compare the formation of dentinal defects using stainless-steel hand K-files (HFs), rotary files, reciprocating files, and Self-Adjusting File (SAF), when used for oval root canals. Materials and Methods: One hundred and forty extracted human mandibular premolar with single root and oval canal were selected for this study. Oval canals were confirmed by exposing to mesio-distal and bucco-lingual radiographs. Teeth with open apices or anatomic irregularities were excluded. All selected teeth were de-coronated perpendicular to the long axis of the tooth, leaving roots segments approximately of 16 mm in length. Twenty teeth were left unprepared (control), and the remaining 120 teeth were divided into 6 groups (n = 20) and instrumented using HF (size 40/0.02), Revo-S (RS; size 40/0.06), ProTaper NEXT (PTN; size 40/0.06), WaveOne (WO; size 40/0.09), RECIPROC (RC; size 40/0.06), and the SAF (2 mm). Roots were then sectioned 3, 6, and 9 mm from the apex, and observed under stereomicroscope, for presence of dentinal defects. "No defect" was defined as root dentin that presented with no visible microcracks or fractures. "Defect" was defined by microcracks or fractures in the root dentin. Results: The control, HF, and SAF did not exhibit any dentinal defects. In roots instrumented by RS, PTN, WO, and RC files exhibited microcracks (incomplete or complete) in 40%, 30%, 55%, and 50%, respectively. Conclusions: The motor-driven root canal instrumentation with rotary and reciprocating files may create microcracks in radicular dentine, whereas the stainless-steel hand file instrumentation, and the SAF produce minimal or less cracks.

Influence of CBCT metal artifact reduction on vertical radicular fracture detection

  • Oliveira, Mariana Rodrigues;Sousa, Thiago Oliveira;Caetano, Aline Ferreira;de Paiva, Rogerio Ribeiro;Valladares-Neto, Jose;Yamamoto-Silva, Fernanda Paula;Silva, Maria Alves Garcia
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.55-62
    • /
    • 2021
  • Purpose: This study evaluated the influence of a metal artifact reduction (MAR) tool in a cone-beam computed tomography (CBCT) device on the diagnosis of vertical root fractures (VRFs) in teeth with different root filling materials. Materials and Methods: Forty-five extracted human premolars were classified into three subgroups; 1) no filling; 2) gutta-percha; and 3) metallic post. CBCT images were acquired using an Orthopantomograph 300 unit with and without a MAR tool. Subsequently, the same teeth were fractured, and new CBCT scans were obtained with and without MAR. Two oral radiologists evaluated the images regarding the presence or absence of VRF. Receiver operating characteristic (ROC) curves and diagnostic tests were performed. Results: The overall area under the curve values were 0.695 for CBCT with MAR and 0.789 for CBCT without MAR. The MAR tool negatively influenced the overall diagnosis of VRFs in all tested subgroups, with lower accuracy (0.45-0.72), sensitivity (0.6-0.67), and specificity (0.23-0.8) than were found for the images without MAR. In the latter group, the accuracy, sensitivity, and specificity values were 0.68-0.77, 0.67-083, and 0.53-087, respectively. However, no significant difference was found between images with and without MAR for the no filling and gutta-percha subgroups (P>0.05). In the metallic post subgroup, CBCT showed a significant difference according to MAR use (P<0.05). Conclusion: The OP 300 MAR tool negatively influenced the detection of VRFs in teeth with no root canal filling, gutta-percha, or metallic posts. Teeth with metallic posts suffered the most from the negative impact of MAR.

A multidisciplinary approach to restore crown-root fractured maxillary central incisors: orthodontic extrusion and surgical extrusion (치관-치근 파절이 발생한 상악 중절치를 수복하기 위한 다각적 접근법: 교정적 정출술과 외과적 정출술)

  • Kwon, Eun-Young;Kim, So-Yeun;Jung, Kyoung-Hwa;Choi, Youn-Kyung;Kim, Hyun-Joo;Joo, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.262-271
    • /
    • 2020
  • To restore a tooth with a fracture line extending below the marginal bone level, a surgical crown lengthening procedure accompanied by ostectomy could be considered to expose the fracture line and reestablish the biologic width. However, this procedure could lead to esthetic failure, especially in the anterior teeth. Therefore, orthodontic extrusion, which elevates the fracture line from within the alveolar socket without sacrificing the supporting bone and gingiva, is recommended. This technique allows for the proper placement of the crown on a sound tooth structure, with the reestablishment of the biologic width. Alternatively, surgical extrusion is an one-step procedure that is simpler and less time-consuming than orthodontic extrusion; placing and adjusting the orthodontic appliance does not require multiple visits. This study presents successful restoration in 2 cases with a crown-tooth root fracture of the maxillary central incisor treated using a multidisciplinary approach through orthodontic extrusion or surgical extrusion followed by successful restoration.

Mandibular implant-natural tooth retained overdenture using magnetic attachment with stress breaker (하악에서 완압형 자성 어태치먼트를 부착한 임플란트-자연치 피개 의치: 10년 증례보고)

  • Park, Eun-Chul;Lee, Su-Yeon;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.378-386
    • /
    • 2015
  • Overdenture has the advantage of improving the stability and retention of the denture but the abutment may be easily affected by caries or periodontal disease and the thin denture can be easily broken. The magnetic attachment overdenture has a high vertical retention but a low horizontal retention, thus, exerting a less disruptive force to the abutment or implant and shows less abrasion or damage compared to other mechanical retainers. Denture fractures in overdenture is caused by the thin denture base as the attachment is inserted, but it may also be caused by the difference in detrusion between soft tissue and hard tissue, and between an implant and a natural tooth. To compensate this shortcoming, a magnetic attachment with a silicone ball inserted in the magnet was developed as we report a successful case using this specific type of magnetic attachment overdenture.