• Title/Summary/Keyword: Tooth displacement

Search Result 200, Processing Time 0.028 seconds

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON DURING DISTAL EN MASSE MOVEMENT OF THE MAXILLARY DENTITION (상악 치열의 치군 후방이동에 관한 3 차원 유한요소법적 연구)

  • Shin, Soo-Jung;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.563-580
    • /
    • 1998
  • This study was designed to analysis the displacement and stress distribution of individual tooth by orthodontic force during distal on masse movement of the maxillary dentition. In this study, three dimensional finite element analysis was used. Author made the finite element model of maxillary teeth, periodontal ligament, alveolar bone and bracket with anatomic and physiologic characteristics on computer. Author analysed and evaluated the displacement and stress distribution of individual tooth when extraoral force, Class II intermaxillary elastics, ideal arch wire, MEAW and tip back bend were used for distal on masse movement of the maxillary dentition. These analyses were also applied in the case of the maxillary second molar were not extracted. Author compared the results of the cases which maxillary second molar were extracted or not. The results were expressed quantitatively and visually. Author obtained following results, 1. When anterior headgear was applied, the posterior translation, posterior tipping, and vertical displacement of teeth were produced more in the anterior segment of the dentition. 2. When Class II intermaxillary elastics were applied in the ideal arch wire, the teeth displacement were usually produced in the anterior segment. But when tip back bend were added in the ideal arch wire, the orthodontic force produced by elastics were transmitted to the posterior segment. As increasing the tip back bend, posterior translation and lingual tipping of anterior teeth were decreased, posterior translation and tipping displacement of posterior teeth were increased, and extrusion of anterior teeth by Class II elastics were decreased 3. When MDAW and Class II elastics were applied, the teeth movement were sir flu with the case of ideal arch wire and Class II elastics, but more small and uniform teeth displacement were produced Compared with the ideal arch wire, posterior tipping of the posterior segment were more produced than lingual tipping displacement of the anterior segment. 4. When the maxillary second molar without orthodontic appliance existed, the displacement of maxillary first molar were decreased.

  • PDF

Stress distributions at the Periodontal ligament and displacements of the maxillary first molar under various molar angulation and rotation . Three dimensional finite element study (구치의 경사도와 회전정도가 발치공간 폐쇄시 치근막의 응력분포와 치아의 초기이동에 미치는 영향에 대한 3차원 유한요소법적 연구)

  • Kwon, Dae-Woo;Son, Woo-Sung;Yang, Hoon-Chul
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.417-428
    • /
    • 2004
  • The purpose of this study was to evaluate the stress distributions at the periodontal ligament (PDL) and displacements of the maxillary first molar when mesially directed force was applied under various molar angulations and rotations. A three dimensional finite element model of the maxiilary first molar and its periodontal ligament was made Upright position, mesially angulated position by $20^{\circ}$ and distally angulated position of the same degree were simulated to investigate the effect of molar angulation. An anteriorly directed force of 200g countertipping moment of 1,800gm-mm (9:1 moment/force ratio) and counterrotation moment of 1,000gm-mm (5:1 moment/force ratio) were applied in each situation. To evaluate the effect of molar rotation on the stress distribution, mesial-in rotation by $20^{\circ}$ and the same amount of distal-in rotation were simulated. The same force and moments were applied in each situation. The results were as follows: In all situations, there was no significant difference in mesially directed tooth displacement Also, any differences in stress distributions could not be found, in other words. there were no different mesial movements. Stress distributions and tooth displacement of the $20^{\circ}$ mesially angulated situation were very similar with those of the $20^{\circ}$ distal-in rotated situation. The same phenomenon was obserned between the $20^{\circ}$ distally angulated situation and $20^{\circ}$ mesial-in rotated situation. When the tooth was mesially angulated, or distal-in rotated, mesially directed force made the tooth rotate in the coronal plane. with its roots moving buccally, and its crown moving lingually. When the tooth was distally angulated, or mesial-in rotated, mesially directed force made the tooth rotate in the coronal plane, with its roots moving lingually and its crown moving buccally. When force is applied to au angulated or rotated molar, the orthodontist should understand that additional torque control is needed to prevent unwanted tooth rotation in the coronal plane.

A STUDY OF THE STRESS DISTRIBUTION ON THE SECOND ABUTMENT AND SUPPORTING TISSUES IN FIXED PARTIAL DENTURE USING THREE DIMENSIONAL FINITE ELEMENT ANALYSIS METHOD (고정성 가공의치에서 이차 지대치에 발생하는 응력의 삼차원 유한요소법적 분석)

  • Kim, Jeong-Hee;Jo, Kwang-Hun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.675-694
    • /
    • 2000
  • The purpose of this study was to investigate the displacement of and the stress distribution on the prosthesis, abutment, and its supporting tissues under functional load, and the effect of alteration in root length of 2nd abutment. The 3-dimensional finite element method was used and the finite element models were prepared in which the abutments of left mandibular 5 unit axed partial denture were canine, the 1st pre-molar and the 2nd molar, and the root lengths of canines were as follows. Model I : Root length of canine was 2mm longer than the 1st premolar Model II : Root length of canine was 2mm shorter than the 1st premolar Static compressive force of 300N was applied to connector between 2nd premolar & 1st molar, and then von Mises stress, displacement and reaction force were obtained. The results were as follows : 1. In fixed partial denture, prosthesis under load on pontic was rotated around mesio-distal long axis of it from longual side to buccal, and simultaneously bended in buccal and gingival direction with mesial end deformed in gingival direction and distolingual end in occlusal. 2. Clinical crowns of abutments were bended in the same directions with those in which prosthesis deforms. Due to that, roots of anterior abutments were twisted in counterclockwise with concentration of shear stress on distal or distobuccal sides of their cervices, and that of posterior was in clockwise with concentration of shear stress on mesiobuccal side of it in the same level with anterior abutments. 3. In case that root length of the 2nd abutment was longer than that of the 1st abutment, its displacement and reaction force which means the force tooth exerts on the surrounding periodontal tissues were smaller but shear stress on itself was larger than in the case root length of 2nd abutment was shorter.

  • PDF

Distalization pattern of whole maxillary dentition according to force application points

  • Sung, Eui-Hyang;Kim, Sung-Jin;Chun, Youn-Sic;Park, Young-Chel;Yu, Hyung-Seog;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.45 no.1
    • /
    • pp.20-28
    • /
    • 2015
  • Objective: The purpose of this study was to observe stress distribution and displacement patterns of the entire maxillary arch with regard to distalizing force vectors applied from interdental miniscrews. Methods: A standard three-dimensional finite element model was constructed to simulate the maxillary teeth, periodontal ligament, and alveolar process. The displacement of each tooth was calculated on x, y, and z axes, and the von Mises stress distribution was visualized using color-coded scales. Results: A single distalizing force at the archwire level induced lingual inclination of the anterior segment, and slight intrusive distal tipping of the posterior segment. In contrast, force at the high level of the retraction hook resulted in lingual root movement of the anterior segment, and extrusive distal translation of the posterior segment. As the force application point was located posteriorly along the archwire, the likelihood of extrusive lingual inclination of the anterior segment increased, and the vertical component of the force led to intrusion and buccal tipping of the posterior segment. Rotation of the occlusal plane was dependent on the relationship between the line of force and the possible center of resistance of the entire arch. Conclusions: Displacement of the entire arch may be dictated by a direct relationship between the center of resistance of the whole arch and the line of action generated between the miniscrews and force application points at the archwire, which makes the total arch movement highly predictable.

Characteristics of bony changes and tooth displacement in the mandibular cystic lesion involving the impacted third molar

  • Lee, Jin-Hyeok;Kim, Sung-Min;Kim, Hak-Jin;Jeon, Kug-Jin;Park, Kwang-Ho;Huh, Jong-Ki
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.5
    • /
    • pp.225-232
    • /
    • 2014
  • Objectives: The purpose of this retrospective study is to find the differentiating characteristics of cystic and cystic-appearing lesions that involve the impacted mandibular third molar by analyzing panoramic radiographs and computed tomography images, and to aid the preoperative diagnosis. Materials and Methods: Eighty-one patients who had a mandibular cystic or cystic-appearing lesion that involved impacted mandibular third molar and underwent cyst enucleation were included in the study. The preoperative panoramic radiograph and computed tomography findings were analyzed in accordance to the histopathologic type. Results: Most of the cystic lesions containing the mandibular third molar were diagnosed as a dentigerous cyst (77.8%). The occurrence of mesio-distal displacement of the third molar was more frequent in the odontogenic keratocyst (71.4%) and in the ameloblastoma (85.7%) than in the dentigerous cyst (19.1%). Downward displacement was primarily observed in each group. Odontogenic keratocyst and ameloblastoma showed more aggressive growth pattern with higher rate of bony discontinuity and cortical bone expansion than in dentigerous cyst. Conclusion: When evaluating mandibular cystic lesions involving the impacted mandibular third molar, dentigerous cyst should first be suspected. However, when the third molar displacement and cortical bone absorption are observed, then odontogenic keratocyst or ameloblastoma should be considered.

A FINITE ELEMENT STRESS ANALYSIS OF TOOTH AND IMPLANT SUPPORTED FIXED PARTIAL DENTURE ACCORDING TO THE LOCATION OF NON-RIGID CONNECTOR (치아 및 임플랜트 지지 고정성 국소의치의 비고정성 연결부의 위치에 따른 유한요소법적 응력분석)

  • An, Byoung-Ju;Hwang, Young-Pil;Kay, Kee-Sung;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.807-823
    • /
    • 1995
  • The purpose of this study was to analyze the stress distribution and the displacement happened to the abutment, the prosthesis, and the surrounding structure according to the location of the nonrigid connector, that is, the keyway in the distal of canine and the mesial of the implant in the three unit fixed partial denture. Two-dimensional finite element model ws constructed and analyzed for the stress distribution and the displacement using software ABAQUS(Ver 5.2 Hibbitt, Karisson & Sorenson, Inc., 1992). After finishing the finite element model, the distribution load of 15kg was applied simultaneously to the all cusp tips of the prosthesis and the concentration load of 10㎏ was applied respectively at the each cusp tip of the prosthesis. The following results were obtained : 1. The amount of displacement of the implant was greater in case of the non-rigid connection than the rigid connection, and the more favorable displacement was shown in case of the IKb than the IKa. 2. Without regard to the connection method, the stress represented at the surrounding bone was similar, and the more favorabel stress distribution was shown in case of IKb. 3. The maximum stress was concentrated at the fastening screw and the neck of implant in all experimental groups, and their stress magnitudes were in the order of IKb, IR, and IKa.

  • PDF

Biomechanical analysis of distalization of mandibular molars by placing a mini-plate: A finite element study

  • Park, Myungsoon;Na, Yonghyun;Park, Minbong;Ahn, Janghoon
    • The korean journal of orthodontics
    • /
    • v.47 no.5
    • /
    • pp.289-297
    • /
    • 2017
  • Objective: The objective of this study was to analyze the patterns of tooth movements when distalization of mandibular molars using a mini-plate took place. A finite element analysis was applied to analyze patterns of tooth movements. Methods: The model of the mandible and teeth were used to build a finite element analysis model, and a mini-plate was inserted in the mandibular ramus. Two different orthodontic forces were established for displacement of mandibular molars. Orthodontic forces were applied at the level of the bracket and at the level of the cemento-enamel junction in the mandibular canine respectively. Results: Applying orthodontic forces at the level of the cemento-enamel junction resulted in a greater biomechanical bodily movement in distalization of the mandibular molars compared to when the orthodontic forces were applied at the level of the bracket. Applying orthodontic forces to the cemento-enamel junction also resulted in unwanted greater extrusive movements in distalization of the mandibular molars compared to the bracket level. Conclusions: With considering the mode of orthodontic teeth movement, applying different vertical orthodontic forces for distalization of mandibular molars can lead to more effective distalization of teeth.

Structural Analysis of Engine Mounting Bracket (엔진 마운팅 브라켓의 구조해석)

  • Han, Moon-Sik;Cho, Jae-Ung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.4
    • /
    • pp.525-531
    • /
    • 2012
  • This study aims at the structural analysis of vibration and fatigue according to the configuration of engine mount. Maximum equivalent stress or deformation is shown at bracket or case respectively. As harmonic vibration analysis, the maximum displacement amplitude is happened at 4,000Hz. Among the cases of nonuniform fatigue loads, 'SAE bracket history' with the severest change of load becomes most unstable but 'Sample history' or 'Saw tooth' becomes most stable. In case of 'Sample history' or 'Saw tooth' with the average stress of 4,200MPa or 0MPa and the amplitude stress of -3,000MPa or 7MPa, the possibility of maximum damage becomes 70%. This stress state can be shown with 7 times more than the damage possibility of 'SAE bracket history' or 'SAE transmission'. The structural result of this study can be effectively utilized with the design on engine mount by investigating prevention and durability against its damage.

Development of Dental Chewing Masticator (치과용 저작 매스티케이터의 개발)

  • Lee, Kwon-Yong;Jung, Il-Young;Park, Sung-Ho;Jeon, Seung-Beom
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.255-258
    • /
    • 2002
  • Dental chewing masticator, which is an essential device for evaluating the wear of dental resin and the interfacial failure between the filling resin and enamel of tooth used in conservative dentistry, was developed. This dental chewing masticator mimics the chewing motion and loading by adapting DC motor and rotary cam system. Chewing loading of 49N was imposed by computer-displacement control, loadcell, LM guide, and spring system. Extracted tooth was fixed into a holding jig, and this jig was mounted with rubber pad on the $15^{\circ}$inclined surface to consider the lateral movement of periodontal ligament. A water bath was installed for providing the environment of inside mouth and for circulating the $5^{\circ}C-55^{\circ}C$ water to evaluate the effect of hydrothermal cycling on the damage of resin filled teeth during long-term chewing activity.

  • PDF

Precise open-loop positioning using LPM with error correction

  • Furuhashi, Hideo;Shingu, Hiroyasu;Hayashi, Niichi;Watanabe, Shigeo;Sumi, Tetsuo;Uchida, Yoshiyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.211-214
    • /
    • 1995
  • A precise open-loop positioning system using linear pulse motor has been developed. The system is operated in a microstepping mode by controlling the electric current. One step of 508 .mu.m (tooth pitch of the linear pulse motor) is divided into 508 micro-steps equally. The displacement is measured with a system using a Fiezeau-type interferometer. Periodical positioning error with a period of the tooth pitch was observed in this system. Therefore, the position is corrected using the error. The error is stored into computer in advance, and the microstep current is corrected on basis of the stored data. Although the positioning error of the system without the correction was .+-.4.5 .mu.m, that with the correction was decreased to .+-.1.0 .mu.m.

  • PDF