• 제목/요약/키워드: Tooth bone

검색결과 939건 처리시간 0.022초

Clinical evaluation of ridge augmentation using autogenous tooth bone graft material: case series study

  • Lee, Ji-Young;Kim, Young-Kyun;Yi, Yang-Jin;Choi, Joon-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권4호
    • /
    • pp.156-160
    • /
    • 2013
  • Objectives: Interest in bone graft material has increased with regard to restoration in cases of bone defect around the implant. Autogenous tooth bone graft material was developed and commercialized in 2008. In this study, we evaluated the results of vertical and horizontal ridge augmentation with autogenous tooth bone graft material. Materials and Methods: This study targeted patients who had vertical or horizontal ridge augmentation using AutoBT from March 2009 to April 2010. We evaluated the age and gender of the subject patients, implant stability, adjunctive surgery, additional bone graft material and barrier membrane, post-operative complication, implant survival rate, and crestal bone loss. Results: We performed vertical and horizontal ridge augmentation using powder- or block-type autogenous tooth bone graft material, and implant placement was performed on nine patients (male: 7, female: 2). The average age of patients was $49.88{\pm}12.98$ years, and the post-operative follow-up period was $35{\pm}5.31$ months. Post-operative complications included wound dehiscence (one case), hematoma (one case), and implant osseointegration failure (one case; survival rate: 96%); however, there were no complications related to bone graft material, such as infection. Average marginal bone loss after one-year loading was $0.12{\pm}0.19$ mm. Therefore, excellent clinical results can be said to have been obtained. Conclusion: Excellent clinical results can be said to have been obtained with vertical and horizontal ridge augmentation using autogenous tooth bone graft material.

증령에 따른 치아 및 치조골의 고경 변화에 관한 연구 (A Study on the Changes of Vertical height in Teeth and Alveolar Bone with Age)

  • Se-Sook Kang;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • 제13권1호
    • /
    • pp.13-21
    • /
    • 1988
  • The author studied the vertical height of tooth crown and the amounts of alveolar bone resorption with age. All 84 subjects(44 male, 40female) who visited Dental hospital of Wonkwang University with no history of sever periodontal disease and no experience of periodontal surgery. 84 subject were divided into 3 groups by age, that is, group I(28-32yrs), group II(38-42yrs), and group III(48-52yrs). Informal radiogram with bite wing film(horizontal angulation : $0^{\circ}$, vertical angulation : $+5^{\circ}~+10^{\circ}$) were taken on premolar and molar area. The distances from cusp tip to cementoenamel junction (vertical height of tooth crown) and from cementoenamel junction alveolar crest(amount of alveolar bone resorption) were measured, and then recorded data from 946 teeth were statistically analysed. This study was undertaken to obtain the data for age estimation by the changes of tooth crown height and alveolar bone resorption in the point of forensic odontology. The obtained results were as follows : 1. The average crown height of mandibular right 1st. molar was 7.1mm in group I, 6.7mm in group II, and 6.6mm group III, and the average amount of alveolar bone resorption on mandibular right 1st. molar were 1.8mm in group I, 2.5mm in group II, and 3.0mm in group III. Ratio of tooth crown height to amount of alveolar bone resorption was 4.0:1 in groupI, 2.7:1 in group II, and 2.2:1 in group III, the ratio was decreased with age. 2. In comparison with upper teeth and lower teeth in ipsilateral side, the average value of tooth crown height and amount of alveolar bone resorption were slightly higher in upper arch than those in lower arch, but there was not a statistically significant difference. 3. The ratio of height of tooth crown to amount of alveolar bone resorption was decreased with age, and which depended mainly upon the change of amount of alveolar bone resorption rather than the change of tooth crown height.

  • PDF

Autogenous fresh demineralized tooth graft prepared at chairside for dental implant

  • Kim, Eun-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.8.1-8.6
    • /
    • 2015
  • Background: This study aimed to evaluate the clinical usefulness of autogenous fresh demineralized tooth (auto-FDT) graft prepared at the chairside for alveolar bone grafting during dental implant surgery. Methods: In total, 38 patients requiring both tooth extraction (for endodontic or periodontal reasons or third molar extraction) and alveolar bone regeneration for dental implant placement were included. Within 2 h after clean extraction, the teeth were prepared at the chairside to serve as bone graft material. In the same sitting, blocks or chips of this graft material were used to reconstruct defects at the osteotomy site simultaneously with or before implant placement. Twelve months after prosthesis fabrication and placement, the clinical findings and implant success rates were evaluated. Histological studies were randomly conducted for selected cases. Results: Clinical evaluation showed favorable wound healing with minimal complications and good bone support for the implants. No implant was lost after 12 months of function following prosthetic rehabilitation. Histological examination revealed new bone formation induced by the graft material. Conclusions: Chairside preparation of autogenous fresh demineralized teeth after extraction can be a useful alternative to the use of autogenous bone or other graft materials for the immediate reconstruction of alveolar bone defects to facilitate subsequent implant placement.

Comparison of immunohistochemical analysis on sinus augmentation using demineralized tooth graft and bovine bone

  • Sohn, Dong-Seok;Kim, Ji-Rak;Kim, Hyung-Gyun;Choi, Hyun-Suk;Moon, Yong-Suk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권4호
    • /
    • pp.269-278
    • /
    • 2021
  • Objectives: The purpose of this animal research was to compare bone regeneration in augmented rabbit maxillary sinuses treated with demineralized particulate human-tooth graft and anorganic bovine bone by immunohistochemical analysis. Materials and Methods: Piezoelectric bilateral sinus augmentation was performed in eight adult rabbits. In the control group, anorganic bovine was grafted in the maxillary sinus following elevation of the sinus membrane. In the experimental group, demineralized human particulate tooth bone was grafted in the sinus. Bone regeneration in augmented sinuses was evaluated by immunohistochemical analysis using various markers of osteoprogenitor cells. Results: The number of bromodeoxyuridine-labeled cells was significantly higher in the experimental group than in the control group at eight weeks. The immunoreactivity of proliferating-cell nuclear antigen was increased slightly in the experimental group relative to the control group at eight weeks. Other bone markers were expressed equally in the two groups. Conclusion: In the rabbit maxillary sinus, higher osteoinduction was correlated with demineralized human particulate tooth bone grafting than with anorganic bovine grafting.

Use of elevator instruments when luxating and extracting teeth in dentistry: clinical techniques

  • Mamoun, John
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권3호
    • /
    • pp.204-211
    • /
    • 2017
  • In dentistry, elevator instruments are used to luxate teeth, and this technique imparts forces to tooth particles that sever the periodontal ligament around tooth roots inside the socket and expand alveolar bone around tooth particles. These effects can result in extraction of the tooth particles or facilitate systematic forceps extraction of the tooth particles. This article presents basic oral surgery techniques for applying elevators to luxate teeth. Determination of the optimal luxation technique requires understanding of the functions of the straight elevator and the Cryer elevator, the concept of purchase points, how the design elements of elevator working ends and tips influence the functionality of an elevator, application of forces to tooth particles, sectioning teeth at furcations, and bone removal to facilitate luxation. The effectiveness of tooth particle luxation is influenced by elevator tip shape and size, the magnitude and the vectors of forces applied to the tooth particle by the tip, and sectioning and bone removal within the operating field. Controlled extraction procedures are facilitated by a dental operating microscope or the magnification of binocular surgical loupes telescopes, combined with co-axial illumination.

상악 단일 치아 임프란트의 후향적 연구 (A Retrospective study on upper single tooth implants)

  • 조수진;이근우;조규성;문익상
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.383-393
    • /
    • 2003
  • The aim of this retrospective study was to compare the amount of marginal bone loss between upper anterior area and upper posterior area with 71 upper single-tooth restorations on 2 stage machined $Br{{\aa}}nemark$ implants since Jan 1995. The second aim was to compare the bone defect group which had dehiscence and fenetration and the others in the upper anterior region. The results were as follows. 1. The most frequent reason of missing tooth in the upper anterior region was trauma by 61%. While upper posterior region showed various reasons such as congenital missing, advanced periodontitis, trauma. 2. Peri-implantitis with fistula occurred 1 of 41 implants in the upper anterior group in 1 year after loading and 2 of 32 implants in the upper posterior group failed before loading. The 1 year success rate of upper anterior group was 97.56 %, and 93.75 % for upper posterior group. 3. The mean marginal bone loss in the upper anterior group was 0.44${\pm}$0.25 mm, while 0.57${\pm}$0.32 mm in the upper posterior group. There was statistically significant difference in the amount of mean marginal bone loss (P${\pm}$0.10 mm at one year, and 0.48${\pm}$0.26 mm for the control group. No statistically significant difference of mean marginal bone loss was showen between bone defect group and the others at implantation. According to the results, the upper anterior region showed less marginal bone loss than the upper posterior region. In case of missing single upper tooth, careful consideration on recipient residual ridge to determine proper implant diameter and length, sufficient healing time, proper loading would lead to implant success. Single tooth implants in the maxilla seemed to be an alternative to fixed partial dentures without damage to adjacent teeth.

인접 치주조직과 임플란트간 거리가 임플란트 주변 골흡수에 미치는 영향;임상 및 방사선사진 검사에 의한 후향적 연구 (Influence of the adjacent periodontium and inter-implant distance on bone resorption around non-submerged implants;A retrospective clinical and radiographic study)

  • 장문택
    • Journal of Periodontal and Implant Science
    • /
    • 제34권3호
    • /
    • pp.535-541
    • /
    • 2004
  • The aims of the present study are firstly to investigate the amount of bone loss around non-submerged implants placed in the posterior region and secondly to investigate the relationship between inter-implant and implant-tooth distance and peri-implant bone loss. Thirty-one subjects with 60 implants were selected consecutively from the implant patient pool at the department of Chonbuk National University Hospital. To be included in the study subject, the implant should have been functioned more than 6 months after loading. Inter-implant and implant-tooth distance, distance between implant shoulder and the first bone contact with the implant(DIB) were measured from the scanning image of the radiograph of each implant. The result showed that; 1. inter-implant distance has a statistically significant relationship with DIB in Pearson correlation analysis. 2. the DIB at the implant facing surface of the implant was greater than that of tooth facing surface of the implant. Within limitation of this study, it is suggested to place an implant not too closely to adjacent implants, and the presence of a tooth adjacent to an implant may keep the level of tooth-facing surface of the implant. Further studies with a prospective design are needed to elucidate the relationship between bone changes and various dimensions around implants.

백서에서 실험적 치아이동시 임신이 치조골 교체(Turnover)에 미치는 영향에 대한 연구 (The effects of pregnancy on alveolar bone turnover during experimental tooth movement in rats)

  • 김영선;이기수
    • 대한치과교정학회지
    • /
    • 제30권4호
    • /
    • pp.413-421
    • /
    • 2000
  • 임신중 전신의 호르몬 변화는 골대사과정에 영향을 주고 임신 중에는 골교체가 증가하며, 교정력에 의한 치아이동에는 치조골 교체가 수반된다고 알려져 있다. 이 연구는 임신으로 인한 전신의 호르몬 변화가 치아이동 중 치조골 교체에 주는 영향을 알아보기 위하여 시행되었다. 생후 10주령의 암컷 백서 60마리를 대상으로 정상군과 정상-치아이동군, 임신-치아이동군의 3군으로 나누고 치아이동일수에 따라 1,3,7,14일군으로 세분한 후 상악 제1대구치 에 40g의 교정력을 가하여 근심측으로 치아이동을 시행하였다. 치아이동 전후에 촬영한 X-ray사진을 계측하여 치아이동 거리를 비교하고 치조골에서의 alkaline phosphatase, tartrate-resistant acid phosphatase 농도를 측정하여 치아이동에 따른 골형성과 흡수 활성을 비교하여 다음과 같은 결과를 얻었다. 1. 치아이동량은 임신-치아이동군이 정상-치아이동군에 비하여 더 크게 나타났다(p<0.01). 2. 정상-치아이동군의 치아이동에 따른 골형성은 대조군과 차이가 없었지만 골흡수 경향은 증가되었고(p<0.01), 정상-치아이동군에서는 대조군에 비하여 치조골의 형성과 흡수 활성이 모두 치아이동 7일에 가장 크게 증가하였고 (p<0.01) 이후 골형성 활성은 감소하였지만(p<0.05) 골흡수 활성은 대조군보다 높게 유지되었다(p<0.01). 3. 임신군과 정상군의 치아이동에 따른 골형성과 흡수 경향에는 차이가 없었지만, 임신-치아이동군의 치조골 형성 (p<0.01)과 흡수(p<0.05) 활성의 증가는 3일경에 가장 높게 나타났으며, 이후 골형성 활성은 감소하였으나 골흡수 활성은 높게 유지되었고, 정상-치아이동군은 7일경에 치조골 형성과 흡수 활성의 증가가 나타났다. 임신중의 치아이동량이 정상 치아이동에 비하여 크게 나타났으며, 치조골 흡수와 형성 활성의 증가가 빠르게 나타났고 치조골 흡수가 더 오랬동안 지속되어 빠른 치조골 교체를 보이므로 임신상태에서 치 아이동은 정상상태보다 촉진될 가능성이 있음을 시사한다.

  • PDF

Intermittent Administration of Parathyroid Hormone for Orthodontic Tooth Movement in Mongrel Dogs: Preliminary Study

  • Won-Ho Kim;Bo Ram Lee;Hey-Yun Kim;Minji Kim;Jin-Woo Kim
    • Journal of Korean Dental Science
    • /
    • 제16권2호
    • /
    • pp.182-191
    • /
    • 2023
  • Purpose: This study investigated the orthodontic tooth movement after weekly parathyroid hormone (PTH) injection in mongrel dogs and analyzes bone formation activity on the tension and pressure sides of the tooth movement in mongrel dogs. Materials and Methods: Three mongrel dogs were used in this study. The first premolar was extracted and orthodontic force using 150 g of closed coil springs between the canine and second premolar was applied. The low-dose PTH group (PTH_1) and high-dose PTH group (PTH_2) received weekly injections of 1.61 ㎍/kg and 3.23 ㎍/kg of PTH, respectively. The control group received weekly injections of 1 ml of saline. Clinical, histomorphometric analysis were carried out. Result: The orthodontic tooth movement was greatest in the PTH_2 group and the lowest in the control group. Fluorescence staining images showed higher bone remodeling on the tension side of the tooth movement in the PTH_1 and PTH_2 groups. PTH_2 group showed a thicker labeling band than the PTH_1 group. PTH_2 group showed the highest mineral apposition rate and bone formation rate, followed by the PTH_1 group and the control group. Conclusion: Weekly intermittent PTH injection, especially in the short-term and at higher doses with orthodontic force, successfully increased orthodontic tooth movement and bone remodeling in mongrel dogs.

망상골의 구조와 밀도가 치과용 임플란트와 하악골에 미치는 영향 (Effects of trabecular bone microstructure on stress distribution within premolar tooth and implant)

  • 전창수;이상업;이경중;김한성
    • 한국정밀공학회지
    • /
    • 제22권10호
    • /
    • pp.210-217
    • /
    • 2005
  • This study examined the effect of cancellous bone microstructure on stress distribution within a premolar tooth and a dental implant against mastication force by the micro-finite element method (FEM). The mandibular specimen including a premolar was obtained from a cadaver and scanned with micro-CT to obtain CT images. FE models were reconstructed from CT images at mid-sagittal plane of the tooth. Six models were generated and analyzed for different structure and density in cancellous bone. Stress distributions fur each implant (or tooth) and the surrounding bone were compared. The study indicated that the microstructure of cancellous bone should be considered in finite element analysis to produce reasonable results and thus implant systems with high success rate.