• Title/Summary/Keyword: Tooth Tip

Search Result 98, Processing Time 0.023 seconds

On a Method for the Durability Enhancement of Plastic Spur Gear Using Finite Element Analysis (유한요소해석에 의한 플라스틱 스퍼기어의 내구성 향상방안 연구)

  • Kim, Choong-Hyun;Ahn, Hyo-Sok;Chong, Tae-Hyong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.2
    • /
    • pp.223-230
    • /
    • 2003
  • Stress patterns are created in the plastic spur gear tooth body by introducing a hole or a steel pin to improve stress distribution. Static analysis using finite element method is carried out to show the effect. The result shows that maximum stress as well as tooth tip displacement is dependent on the size and location of a hole or a steel pin. When a hole located on the tooth center line, the maximum static stress level and the tooth tip deflection is always higher than that of a solid gear. But, a considerable reduction in the maximum stress and tooth tip displacement is achieved by insertion of steel pin.

A Study on the Sliding Wear Rate Calculation in Spur Gears (Spur Gear의 미끄럼 마멸률에 관한 연구)

  • 김태완;문석만;구영필;조용주
    • Tribology and Lubricants
    • /
    • v.16 no.5
    • /
    • pp.357-364
    • /
    • 2000
  • In this study, the sliding wear in spur gears, using Archard's wear model, is analyzed. Formulas of tooth sliding wear depth along the line of action are derived. The tooth profile is modified Id make a smooth transmission of the normal loads and the cylinder profile for reducing the pressure spike is suggested. The sliding wear rate is calculated with these profiling results. We expect these modification methods to contribute to the reduction of sliding wear not only in the root, but the tip of tooth and tooth edge.

Use of elevator instruments when luxating and extracting teeth in dentistry: clinical techniques

  • Mamoun, John
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.3
    • /
    • pp.204-211
    • /
    • 2017
  • In dentistry, elevator instruments are used to luxate teeth, and this technique imparts forces to tooth particles that sever the periodontal ligament around tooth roots inside the socket and expand alveolar bone around tooth particles. These effects can result in extraction of the tooth particles or facilitate systematic forceps extraction of the tooth particles. This article presents basic oral surgery techniques for applying elevators to luxate teeth. Determination of the optimal luxation technique requires understanding of the functions of the straight elevator and the Cryer elevator, the concept of purchase points, how the design elements of elevator working ends and tips influence the functionality of an elevator, application of forces to tooth particles, sectioning teeth at furcations, and bone removal to facilitate luxation. The effectiveness of tooth particle luxation is influenced by elevator tip shape and size, the magnitude and the vectors of forces applied to the tooth particle by the tip, and sectioning and bone removal within the operating field. Controlled extraction procedures are facilitated by a dental operating microscope or the magnification of binocular surgical loupes telescopes, combined with co-axial illumination.

Mechanical characteristics of involute-circular arc composite tooth profile (인벌류우트-圓弧 合成齒形의 諸特性)

  • 변준형;최상훈;윤갑영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.870-875
    • /
    • 1986
  • In this study, full-rounded tip curve of rack and its mating fillet curve of pinion in Involute-circular arc composite tooth profile are derived. Mechanical characteristics are calculated analytically, i.e., Specific sliding, Nominal bending stress at working root circle and the Contact factor of the arc of contact in circular arc part to the arc of double contact. These characteristics compared with standard involute tooth profile are improved in circular arc part of composite tooth profile. To obtain more efficient composite tooth profile, we studied these characteristics with regard to the changes of unwound angle and radius of circualr arc. And a design method of composite tooth profile is suggested. Composite tooth profile are compared with standard involute tooth profile.

A Study on the Sliding Wear Calculation in Spur Gears (Spur Gear의 미끄럼 마멸율에 관한 연구)

  • 김태완;문석만;강민호;조용주
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.25-34
    • /
    • 1999
  • In this study, the sliding wear in spur gears, using Archard's wear model, is analyzed. Formulas of tooth sliding wear depth along the line of action are derived. The tooth profile is modified Id make a smooth transmission of the normal loads and the cylinder profile for reducing the pressure spike is suggested. The sliding wear rate is calculated with these profiling results. We expect these modification methods to contribute to the reduction of sliding wear in the root and the tip of tooth and tooth edge.

  • PDF

An analysis on the factors responsible for relative position of interproximal papilla in healthy subjects

  • Kim, Joo-Hee;Cho, Yun-Jung;Lee, Ju-Youn;Kim, Sung-Jo;Choi, Jeom-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.4
    • /
    • pp.160-167
    • /
    • 2013
  • Purpose: This study examined the factors that can be associated with the appearance of the interproximal papilla. Methods: One hundred and forty-seven healthy interproximal papillae between the maxillary central incisors were examined. For each subject, a digital photograph and periapical radiograph of the interdental embrasure were taken using a 1-mm grid metal piece. The following parameters were recorded: the amount of recession of the interproximal papilla, contact point-bone crest distance, contact point-cemento-enamel junction (CEJ) distance, CEJ-bone crest distance, inter-radicular distance, tooth shape, embrasure space size, interproximal contact area, gingival biotype, papilla height, and papilla tip form. Results: The amount of recession of the interproximal papilla was associated with the following: 1) increase in contact point-bone crest, contact point-CEJ, and CEJ-bone crest distance; 2) increase in the inter-radicular distance; 3) triangular tooth shape; 4) decrease in the interproximal contact area length; 5) increase in the embrasure space size; and 6) flat papilla tip form. On the other hand, the amount of gingival recession was not associated with the gingival biotype or papilla height. In the triangular tooth shape, the contact point-bone crest distance and inter-radicular distance were longer, the interproximal contact area length was shorter, and the embrasure space size was larger. The papilla tip form became flatter with increasing inter-radicular distance and CEJ-bone crest distance. Conclusions: The relative position of the interproximal papilla in healthy subjects was associated with the multiple factors and each factor was related to the others. A triangular tooth shape carries a higher risk of recession of the interproximal papilla because the proximal contact point is positioned more incisally and the bone crest is positioned more apically. This results in an increase in recession of the interproximal papilla and flat papilla tip form.

A STUDY ON THE EFFECT OF PROSTAGLANDIN E2 ON TOOTH MOVEMENT AND ROOT RESORPTION IN CATS (Prostaglandin E2가 치아이동과 치근흡수에 미치는 영향에 관한 연구)

  • Lee, Gang-Hee;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.19 no.2
    • /
    • pp.25-34
    • /
    • 1989
  • This experiment was performed to study the effect of prostaglandin $E_2$ on tooth movement and root resorption in orthodontically treated cats. Twenty five cats were divided into five groups and closed coil springs delivered 80gm were stretched between upper canine and 3rd premolar. $10{\mu}g$ of $PGE_2$ was injected locally in the submucosal area of the upper right canine, while the left side served as a control and was injected saline 0.1ml. The distance between canine tip and central cusp tip of the 3rd premolar was measured. Scanning electron photomicrographs were made of the coronal half of the distal root surface of canines and cemental craterings were observed and quantified using point-counting volumetry. Data were analyzed by 2-way ANOVA and paired t-test. The results were as follows: 1. The rate of tooth movement of the $PGE_2$ side was increased, particularly at 1 day, compared with the control side. 2. The rate of tooth movement was minimum from 7 days to 10 days. 3. The resorption of root surface of the $PGE_2$ side was decreased from 4 days to 10 days, compared with the control side.

  • PDF

A study on strength of internal gear (내접치차의 강도에 관한 연구)

  • 정태형
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.6 no.3
    • /
    • pp.45-54
    • /
    • 1984
  • Bending strength of an internal gear tooth is discussed as tooth form factor taking into account the actual stress magnitude. Stress analysis was carried out by the finite element method(FEM) for the calculation of tooth form factor of an internal gear. This paper also investigated the influences of number of teeth and addendum modification coefficient of the internal gear and the influences of number of teeth, addendum modification coefficient, pressure angle, radius of rounding of tooth tip, and bottom clearance coefficient of the pinion-shaped cutter on tooth form factor of internal gear. Generalizing the resultant data, a simple formula for the tooth form factor of an internal gear was derived for the calculation of tooth bending strength of an internal gear.

  • PDF

A Study on Composite Tooth Profile Generation of Involute and Circular Are (인벌류우트 - 圓孤 合成齒形의 創成 에 대한 硏究)

  • 최상동;변준형;윤갑영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.572-578
    • /
    • 1985
  • A composite gear with involute-circular are tooth profile and a tooth profile of the rack to cut this gear are theoretictically obtained. The composite gear has involute tooth profile in the vicinity of pitch point and has circular arc tooth profiles at addendum adn dedendum. The contact ratio(M$_{c}$), chordal tooth thickness (chordal tip tooth thickness S$_{t}$, chordal root tooth thickness S$_{t}$) of the composite gear are compared with those of involute gear. When module, number of teeth and pressure angle eqaul, S$_{t}$ of composite gear is much larger than that of involute gear. Under the same conditions, S/sib t/ and M$_{c}$ of composite gear become smaller than those of involute gear.lute gear.

Transmission Error Analysis of the Helical Gears for the Elevator (엘리베이터용 헬리컬기어의 전달오차 해석)

  • Park, Chan-Il;Kim, Dae-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.470-475
    • /
    • 2001
  • The elevator gear box with the helical gears needs to be developed instead of the one with the worm gears to improve the efficiency. In order to develop the gear box, the analytical tool to predict the helical gear noise is necessary to meet customer's noise requirement. Gear noise is related to the loaded transmission error. Therefore, the simulation program for the loaded transmission error analysis of the helical gears is developed in this study. Using the developed program, the effects of tooth modification such as tip relief and the extent of tip relief are investigated. Finally, the procedures to determine the tip relief and the extent of tip relief are proposed.

  • PDF