• 제목/요약/키워드: Tooth Surface

검색결과 876건 처리시간 0.031초

Glass Ionomer Cement의 접착력(接着力)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE BONDING FORCE OF GLASS IONOMER CEMENT)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제7권1호
    • /
    • pp.77-83
    • /
    • 1981
  • The purpose of this study was to observe the bonding strength between tooth surface (enamel and dentin) and restorative filling materials which are two composite resins (Clearfil and Concise) and Glass ionomer cement, after etching with 50% phoshoric acid and 37% citric acid. To measure the bonding strength in enamel, the labial surface of upper anterior tooth was cut flatly with using carborundum disk and polished with sand paper disk, and to measure in dentin, the dentin surface was prepared by grinding upper part of posterior tooth horizontally. After washing the tooth surface with water and drying with air blast, the prepared tooth surface was etched. In glass ionomer cement, 50% phosphoric acid and 37% citric acid were used, in Clearfil 40% phosphoric acid was used and in Concise, 50% phosphoric acid and 37% citric acid were used as etchant for 1 minute. After the copper band which is 5 mm in diameter and 5 mm in height was fixed on the prepared surface and each filling material was inserted into the copper band, the hooking loop was inserted into filled material in the copper band before setting to make it easily that the load is applied on the specimen. After all specimens were immersed in water at $37^{\circ}C$ for 1 week, this specimen was placed on the load cell of tensile test apparatus, and specimen was pulled at the cross-head speed of 0.8 mm per minute. The following results were obtained 1) In glass ionomer cement, the bond strength obtained by 37% citric acid was higher than one obtained by 50% phosphoric acid in enamel and dentin surfaces. The bond strength obtained in non-etched surface was much less than one by etchants in enamel and dentin surface. 2) In Clearfil, the bond strength obtained by 40% phosphoric acid was 4 times more than one obtained by non etch ant. 3) In Concise, the bond strength obtained by 50% phosphoric acid was almost same as one obtained by 37% citric acid, and the bond strength obtained by non etch ant was much less than one obtained by etchants.

  • PDF

전체면 접촉 절삭공구를 이용한 장구형 웜나사 치형가공 연구 (Double Enveloping Worm Thread Tooth Machining Study using Full Face Contact Cutting Tool)

  • 강신준;김용환
    • 소성∙가공
    • /
    • 제29권3호
    • /
    • pp.144-150
    • /
    • 2020
  • In this paper, we propose the generation of a double enveloping worm thread profile with a non-developable ruled surface. Thread surface machining cuts all the way from the tip to the tooth root at one time, like full-face contact machining, rather than cutting several times like point machining. This cutting can reduce the cutting duration and achieve the smooth surface that does not require a grinding process for the threaded surface. The mathematical model of the cutting process was developed from theoretical equations, and the tooth surface was generated using two parameters and modeled in the CATIA using the generated Excel data. Additionally, the machining process of the worm was simulated in a numerical control simulation system. To verify the validity of the proposed method, the deviation between the modeling and the workpiece was measured using a 3D measuring machine.

변색된 유전치의 순측접근에 의한 치수치료 및 레진수복 (LABIAL APPROACH OF PULP TREATMENT AND RESIN RESTORATION ON DISCOLORED NECROTIC PRIMARY ANTERIOR TOOTH)

  • 채문희;송제선;최형준;김성오
    • 대한장애인치과학회지
    • /
    • 제10권2호
    • /
    • pp.84-88
    • /
    • 2014
  • 1. 순측접근법은 치수치료를 순측으로 시행한 후 변색된 순측의 치질을 확대하여 삭제하고 레진으로 순면전체를 수복함으로써 치수치료와 동시에 심미성을 회복할 수 있다. 2. 순측으로 치수치료를 시행하므로 시야가 확보에 유리하고 기구조작이 용이해 행동조절이 잘 되지 않는 어린이에게 추천된다.

In Vitro Study on the Artificial Plaque Removal Effect by Use of 360 Degree Rotating Head with Sonic Tooth-Brush

  • Lim, Jee-Hyun;Kim, Jin-Sil;Choi, Hwa-Young
    • International Journal of Clinical Preventive Dentistry
    • /
    • 제14권4호
    • /
    • pp.228-234
    • /
    • 2018
  • Objective: The authors have experimented for the artificial plaque removal effect of several kinds of 360 degree rotating head typed tooth-brushes with sonic vibratory actioned by using of automatic machine for horizontal scrub method in order to find the better toothbrush type for plaque removal. Methods: The experiment was conducted on three medium to 360 degree rotating head toothbrushes, a medium sized toothbrush and a medium sized toothbrush, and a flat toothbrush consisting of 30 ordinary toothbrushes. A brushing machine with horizontal scrubbing was manufactured and had variations of the end of the bristle attached to or near the surface of the teeth, a vibrating wave action force of 16,000 or 18,000 cycles per minute, and a working time of 2 or 3 minutes. The tooth removal effect was confirmed by scanning and analyzing images with a computer program after automatic brushing with the machine. The elimination rate results for each group were analyzed using the independent t-test and one-way ANOVA test. Results: It revealed the most in removal effect for the artificial plaque in such conditions as action at near the tooth surface with 18,000 cycle for 3 minutes in case of using A, B, and C tooth-brush. And it has more removal effect rate than for using the plane tooth-brush (p<0.05). Conclusion: It was recommended to develop the 360 degree rotating head and vibratory toothbrush focusing to use near the tooth surface with 18,000 cycles of vibration for 3 minutes at one site of the teeth area.

Characteristics of the molar surface after removal of cervical enamel projections: comparison of three different rotating instruments

  • Ko, Min-Jeong;Cho, Chan-Myung;Jeong, Seong-Nyum
    • Journal of Periodontal and Implant Science
    • /
    • 제46권2호
    • /
    • pp.107-115
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate and compare tooth surface characteristics in extracted human molars after cervical enamel projections (CEPs) were removed with the use of three rotating instruments. Methods: We classified 60 extracted molars due to periodontal lesion with CEPs into grade I, II, or III, according to the Masters and Hoskins' criteria. Each group contained 20 specimens. Three rotating instruments were used to remove the CEPs: a piezoelectric ultrasonic scaler, a periodontal bur, and a diamond bur. Tooth surface characteristics before and after removal of the projections were then evaluated with scanning electron microscopy (SEM). We analyzed the characteristics of the tooth surfaces with respect to roughness and whether the enamel projections had been completely removed. Results: In SEM images, surfaces treated with the diamond bur were smoothest, but this instrument caused considerable harm to tooth structures near the CEPs. The piezoelectric ultrasonic scaler group produced the roughest surface but caused less harm to the tooth structure near the furcation. In general, the surfaces treated with the periodontal bur were smoother than those treated with the ultrasonic scaler, and the periodontal bur did not invade adjacent tooth structures. Conclusions: For removal of grade II CEPs, the most effective instrument was the diamond bur. However, in removing grade III projections, the diamond bur can destroy both adjacent tooth structures and the periodontal apparatus. In such cases, careful use of the periodontal bur may be an appropriate substitute.

35% 과산화수소를 함유한 치아미백제가 심미수복재의 색, 미세경도 및 표면 거칠기에 미치는 영향 (The effect of tooth bleaching agent contained 35% hydrogen peroxide on the color, microhardness and surface roughness of tooth-colored restorative materials)

  • 심연수
    • 한국치위생학회지
    • /
    • 제12권3호
    • /
    • pp.533-541
    • /
    • 2012
  • Objectives : The purpose of this study was to evaluate the effects of tooth bleaching agent contained 35% hydrogen peroxide on the color, microhardness and surface roughness of tooth-colored restorative materials. Methods : Four types of tooth-colored restorative materials, including a composite resin(Filtek Z350 ; Z350), a flowable composite resin(Filtek P60 : P60), a compomer(Dyract$^{(R)}$ AP ; DY), and a glass-ionomer cement(KetacTM Molar Easymix ; KM) were used in the study. The specimens($8mm{\times}5mm$) were made by using a customized acrylic mold. Each material was divided into two groups equally(n=40) : experimental group(35% HP) and control group(distilled water). 35% HP group was treated 30 mim/5 days for 15 days. Each 30 minute treatment session consisted of two 15 minute cycles of gel application with 20 second light exposure. The authors measured the color, microhardness, and roughness of the specimens before and after bleaching. The data were analyzed with ANOVA and T-test. Results : 35% HP group showed an apparent color change(${\Delta}E^*$) than control group. In particular, DY and KM showed a noticeable color change and statistically significant differences(p<0.05). 35% HP group showed a reduction in microhardness. Z350 and P60 does not have a statistically significant difference(p>0.05), DY and KM showed a statistically significant difference(p<0.05). Percentage microhardness loss(PML) of control group was 0.6 to 5.5% in the group, 35% HP group was 6.6 to 34.6%. Roughness was increased in 35% HP group after bleaching. Especially DY and KM were significantly increased(p<0.05). Conclusions : Bleaching agents may affect the surface of existing restorations; therefore, they should not be used indiscriminately when tooth-colored restorations are present.

치아표면 거칠기와 시멘트 종류가 전부주조관의 유지력에 미치는 영향 (INFLUENCE OF TOOTH SURFACE ROUGHNESS AND TYPE OF CEMENT ON RETENTION OF COMPLETE CAST CROWNS)

  • 김길수;송창용;안승근;박찬운
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.465-473
    • /
    • 1999
  • Bond strength of luting cements to dentin is a critical consideration for success of complete cast crowns. This study was performed to evaluate the relationship between surface characteristics of teeth prepared for complete cast crowns and retention of cemented restorations. Eighty artificial crowns were cast for standardized complete crown tooth preparations accomplished with the use of a special device on recently extracted human teeth. Coarse diamond(#102R, Shofu) and superfine finishing diamond(#SF102R, Shofu) burs of similar shape were used. Crowns in each group were randomly subdivided into few subgroups of 10 for luting cements selected for this study: zinc phosphate cement (FLECK' S), polycarboxylate cement (Poly-F), rein-forced glass ionomer cement (Fuji PLUS). and adhesive resin cement (Panavia 21). Retention was evaluated by measuring the tensile load required to dislodge the artificial crown from tooth preparations with an Instron testing machine, and analysed by one-way ANOVA and Student's t-test. The obtained results were as follows ; 1. When tooth preparation was done with coarse diamond bur, retentive force was diminished in order of Panavia 21 Fuji PLUS, FLECK'S, and Poly-F. Retentive forces showed the significant difference between Fuji PLUS group and FLECK'S group(p<0.001). 2. When tooth preparation was done with superfine diamond bur, retentive force was diminished in order of Fuji PLUS, Panavia 21, FLECK'S, and Poly-F. Retentive forces showed the significant difference between Panavia 21 group and FLECK'S group(p<0.001). 3. Retentive force in coarse tooth surfaces was significantly higher than that in superfine tooth surface with all luting cements(p<0.001), and cement residues were almost retained with-in the cast crown in all groups.

  • PDF

Effects of HA and TiN Coating on the Electrochemical Characteristics of Ti-6Al-4 V Alloys for Bone Plates

  • Oh, Jae-Wook;Choe, Han-Cheol;Ko, Yeong-Mu
    • 한국표면공학회지
    • /
    • 제37권5호
    • /
    • pp.249-252
    • /
    • 2004
  • Effects of HA and TiN coating on the electrochemical characteristics of Ti-6AI-4V alloys for bone plates were investigated using various test methods. Ti-6AI-4V alloys were fabricated by using a vacuum induction furnace and bone plates were made by laser cutting and polishing. HA was made of extracted tooth sintered and then tooth ash was used as HA coating target. The TiN and HA film coating on the surface were carried on using electron-beam physical vapor deposition (EB-PVD) method. The corrosion behaviors of the samples were examined through potentiodynamic method in 0.9% NaCI solutions at $36.5\pm$$1^{\circ}C$ and corrosion surface was observed using SEM and XPS. The surface roughness of TiN coated bone plates was lower than that of tooth ash coated plates. The structure of TiN coated layer showed the columnar structure and tooth ash coated layer showed equiaxed and anisotrophic structure. The corrosion potential of the TiN coated specimen is comparatively high. The active current density of TiN and tooth ash coated alloy showed the range of about $1.0xl0^{-5}$ $A\textrm{cm}^2$, whereas that of the non-coated alloy was$ 1.0xl0^{-4}$ $A\textrm{cm}^2$. The active current densities of HA and TiN coated bone plates were smaller than that of non-coated bone plates in 0.9% NaCl solution. The pitting potential of TiN and HA coated alloy is more drastically increased than that of the non-coated alloy. The pit number and pit size of TiN and HA coated alloy decreased in compared with those of non-coated alloy. For the coated samples, corrosion resistance increased in the order of TiN coated, tooth ash coated, and non-coated alloy.

Surface Damage and Bleaching Effect according to the Application Type of Home Tooth Bleaching Applicants

  • Tak, Na-Yeoun;Lim, Do-Seon;Lim, Hee-Jung;Jung, Im-Hee
    • 치위생과학회지
    • /
    • 제20권4호
    • /
    • pp.252-260
    • /
    • 2020
  • Background: In this study, the bleaching effect and surface damage of two types of over-the-counter home tooth bleaching agents were explored using an in vitro study of bleaching agents applied to bovine teeth specimens for 14 days. Methods: Domestic over-the-counter home tooth bleaching agents of gel and patch form that shared common active ingredients and manufacturers were selected and tested. The experiment specimens were made using composite resin with bovine tooth samples and then measured the initial microhardness. Specimens were then divided into a Gel group and a Patch group and underwent bleaching treatment once a day for two weeks for 30 to 60 minutes (recommended) or 7 hours. All specimens were coffee-stained prior to bleaching. The bleaching effect was measured using a spectrophotometer and surface damage was measured using a microhardness meter. Results: The difference in color following the bleaching procedure was positive in both the Gel and Patch group, although there were no statistically significant differences in bleaching effect between groups. There was no significant difference in bleaching effect based on duration. The microhardness test revealed that both the Gel group and the Patch group had surface damage after bleaching. The greatest surface damage was found in the Patch group that had undergone a 7-hour bleaching treatment, although the differences were not statistically significant. Conclusion: The bleaching effect of the home tooth bleaching agent was visible to the naked eye. However, longer applications than recommended did not result in greater bleaching, unlike consumers' expectations, and instead increased the chance of enamel damage. As such, there is a need for consumers to be alert and adhere to recommendations provided by each company.

치은 연하 치석 제거와 치근면 활택술시 Gracey curet과 Ultrasonic curet의 치석 제거에 효과에 대한 비교 연구 (A Comparison of Effectiveness of Gracey Curet and Ultrasonic Curet on Subgingival Scaling and Root Planning)

  • 정석형;정진형;임성빈
    • Journal of Periodontal and Implant Science
    • /
    • 제31권1호
    • /
    • pp.257-269
    • /
    • 2001
  • Removal of subgingival calculus is essential for the success in periodontal treatment. Subgingival instrumentation is used for the removal of all bacterial plaque and calculus. In this study, Gracey curet and Ultrasonic curet were used on single rooted teeth to conduct subgingval scaling and root planning. The remaining amount of calculus was evaluated according to type of instrument, depth of pocket, and tooth surface. 24 teeth were extracted from 14 patients being treated at department Periodontology Seoul Advantist dental hospital were used. Total 96 area(4 surface per teeth) were evaluated. 12 teeth treated with Gracey curet were used as the control group and the other 12 teeth treated with Ultrasonic curet were examined for experimental group. The 4 surface of the teeth(buccal, mesial, lingual or palatal, distal) were observed through the stereomicroscope and the images of the surface were captured and saved in CCD. The images were displayed on the monitor and the amount of calculus remained was evaluated by overlapping $10{\times}10$ grid pixel screen produced by Microsoft power point. The results evaluated were as follows 1. There was no statistically significant difference in residual calculus and tooth position following scaling and root planning of all group, but statistically significant correlation with residual calculus, probing depth, instruments and tooth surface. 2. There was statistically significant correlation between residual calculus and probing depth, but no statistically significant difference in residual calculus, tooth surface and tooth position on experimental(Ultrasonic curet) group. 3. There was no statistically significant difference in residual calculus according to the pre-treatment pocket depth and tooth position, but statistically significant correlation with tooth surface. The amount of residual calculus increase with mesial, distal, buccal and lingual(or palatal) surface on control(Gracey curet) group. 4. The Gracey showed better results than ultrasonic curet in mesial and distal surface, and there is significant difference. The results demonstrate that ultrasonic curet alone is inadequate for thorough subgingival debridement and suggest that Ultrasonic curet with Gracey curet should be more effective.

  • PDF