• Title/Summary/Keyword: Tooth Structure

Search Result 317, Processing Time 0.023 seconds

A Study on the Properties of Knit Jacquard Structure (니트 자카드 조직의 특성에 관한 연구)

  • Ki, Hee-Sook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.17 no.4
    • /
    • pp.77-90
    • /
    • 2015
  • This study is to designed to provide foundation for knit design which can apply the thickness and flexibility of jacquard knit by analyzing and comparing mechanical properties of 7 types of jacquard (normal jacquard, bird's eye jacquard, floating jacquard, tubular jacquard, ladder's back jacquard, blister jacquard, transfer jacquard) widely used in knit design to achieve the results. The sample was projected by using 7 gauge and SES-122S type computer knitting machine house tooth pattern with two colors were applied to 7 types of jacquard using Acrylic/Wool(30%/70%) $2/50.5^{\prime}s{\times}4ply\;yarn$ by Shimaseiki MFG., Ltd computer knitting machine. The mechanical properties of 7 types of jacquard samples were measured using KES-FB (Kawabata Evaluation System for Fabric, Kata Tech Co. Ltd). HV(Hand Value) and THV (Total Hand Value) were calculated by using the formula of KN-402-KT and KN-301-WINTER respectively. The measurements were evaluated by 0-to-5 rating scale. As result, the floating jacquard was found to have excellent drape, making it suitable for express feminine silhouette with its most flexible and smooth touch. On the other hand, bird's eye jacquard is adequate for a suit jacket and coat regarding its excellent volume and flexibility. Blister jacquard and tubular jacquard are thick, heavy and stiff knit and both are suitable for simple box-style design. Ladder's back jacquard, however, is more appropriate for expressing the design of feminine charm and voluminous design. Based on the result of this study, it is supposed to provide basic information for development of knit industry regarding jacquard knit by designing the creative knit wear with high production efficiency.

  • PDF

A PHOTOELASTIC STRESS ANALYSIS IN MANDIBULAR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE DESIGNED UNILATERALLY WITH DIFFERENT DIRECT RETAINERS (편측성으로 설계된 하악 유리단 국소의치에서 직접유지장치의 설계 변화에 따른 광탄성 응력 분석에 관한 연구)

  • Son Hong-Suk;Kay Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.25-42
    • /
    • 1992
  • The purpose of this study was to analyze the magnitude and distribution of stress using a photoelastic model from a unilateral distal extention removable partial dentures with five kinds of the direct retainers, that is, the bilaterally designed bar clasp of the cross-arch lingual bar and the unilaterally designed bar clasp, circumferential clasp, mini-Dalbo attachment, and telescope retainer. A photoelastic model for mandible was made of the epoxy resin(PL-1) and hardner (PLH-1) with the acrylic resin teeth used and was coated with plastic cement-1 at the lingual surface of the model, and then five kinds of removable partial dentures were set, A unilateral vertical load of about 16Kg was applied on the first molar and the stress pattern of the photoelastic model under each condition was analyzed by the reflective circular polariscope. The following results were obtained: 1. The conventional removable partial denture with the bilaterally cross arch lingual bar produced the most favorable stress distribution on the residual ridge and supporting structure of abutment teeth than the unilaterally designed removable partial dentures. 2. The unilaterally designed removable partial denture with the bar clasp produced the stress distribution on the residual ridge, except sligtly higher stress concentration on the supporting structure of the abutment teeth, similar to the conventional removable partial denture with the bilaterally designed cross arch lingual bar. 3. On the unilaterally designed removable partial dentures, the bar clasp produced greater stress distribution on the residual ridge and supporting structure of the abutment teeth than the circumferential clasp. 4. On the unilaterally designed removable partial dentures, the mimi-Dalbo attachment produced relatively higher stress concentration on the residual ridge, but produced lesser stress concentration on the supporting structure of the abutment teeth than the other direct retainers. 5. On the unilaterally designed removable partial dentures, the telescope retainer produced uniform stress distribution on the residual ridge, but produced higher stress concentration at the root apex of the terminal abutment tooth than the other direct retainers. 6. On the unilaterally designed removable partial dentures the circumferential clasp and telescope retainer produced slightly higher stress concentration on the residual ridge and supporting structure of the abutment teeth than the bar clasp and mini- Dalbo attachment.

  • PDF

A Study On the Sand Wear Resistance and Formation Behavior of Boride Layer Formed on Ni-Cr-Mo Steel by Plasma Paste Boronizing Treatment (Plasma Paste Boronizing법에 의한 Ni-Cr-Mo강의 붕화물층 생성거동과 내 토사마모특성에 관한 특성)

  • Cho J. H;Park H. K;Son K. S;Yoon J. H;Kim H. S;Kim C. G
    • Korean Journal of Materials Research
    • /
    • v.14 no.1
    • /
    • pp.52-58
    • /
    • 2004
  • The surface property and formation behavior of a boride layer formed on Ni-Cr-Mo steel in a plasma paste boronizing treatment were investigated. The plasma paste boronizing treatment was carried out at 973~1273 K for 1-7 hrs under the gas ratio of Ar:H$_2$ (2:1). The thickness of the boride layer increased with increasing temperature and time in the boronizing treatment. The cross-section of the boride layer was a tooth structure and the hardness was Hv 2000~2500. XRD analysis revealed that the compound was identified as FeB, $Fe_2$B, and mixed phase of FeB/$Fe_2$B in the boride layer formed at 973~1073 K, 1173K, and 1273K, respectively. The Ni-Cr-Mo alloy boronized at 1173-1273 K showed the best excellent wear resistance against the sand. As a results of corrosion test in 1 M $H_2$$SO_4$ solution, $Fe_2$B formed on the matrix alloy exhibited higher corrosion resistance than FeB.

A study on the visible wave of transmittance pressable ceramic core (열가압성형도재 코어의 가시광선 투과율에 관한 연구)

  • Jung, In-Ho;Lee, Sang-Deok;Nam, Sang-Yong
    • Journal of Technologic Dentistry
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the transmittance differences of pressable ceramic core due to thickness within the visible light spectrum. Methods: 36 specimens were divided into 2 groups (0.6mm, 0.8mm) which have each 3 specimens. The size of specimens was 10mm high and 10mm wide. The transmittance of specimens are measured by spectrophotometer Model Cary 500 that can measure infrared-ray, visible wave and ultraviolet-ray. Results: The results shows that there was no significant difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. Conclusion: The individual's color perception is personal and there are numerous factors that influence on it. In general, human eye can perceive the color of thing only within visible light spectrum but in this experiment through spectrophotometer there was no big difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. To sum up, The most important factors were a layed porcelain structure and its thickness rather than core thickness in the porcelain crown. Also, When making all ceramic core with dead pulp (nervous treatment tooth) when used as a restorative esthetic think is more efficient to improve.

Posterior maxillary segmental osteotomy for management of insufficient intermaxillary vertical space and intermolar width discrepancy: a case report

  • Baeg, SeungWoo;On, SungWoon;Lee, JeongKeun;Song, SeungIl
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.28.1-28.6
    • /
    • 2016
  • Backgrounds: Insufficient intermaxillary space is caused by non-restoration following tooth extraction in the past, and this involves eruption of the opposing teeth and changes of the arch structure. Such cases are difficult just by a simple prosthetic approach, and diversified treatment plans should be established. Among these, posterior maxillary segmental osteotomy (PMSO) is an efficient treatment option than extraction of opposing teeth as it surgically repositions multiple erupted teeth and alveolar bone. PMSO can preserve the natural teeth; therefore, it is being regarded as a treatment method which can improve insufficient intermaxillary space significantly. Case presentation: In this case report, the first patient received PMSO in order to place an implant in the mandibular edentulous space after decreased vertical dimension is restored, and the second patient received PMSO along with orthodontic treatment to obtain the intermaxillary space and balance the interarch molar width. Conclusion: PMSO is the treatment of choice when occlusion is compromised in the presence of decreased vertical dimension or arch length discrepancy.

Supply Route Analysis and Performance Evaluation of Dental High-Speed Air Turbine Handpiece (치과용 고속 에어터빈 핸드피스의 공급관로 분석 및 성능평가)

  • Han, Myung-Chul;Kim, Jung-Kwan;Choi, Myoung-Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.1
    • /
    • pp.80-88
    • /
    • 2011
  • The dental high-speed air turbine handpiece is one of the most popular devices that have been widely used as the main means of cutting tooth structure and restorative material in dentistry. In consideration of usage and marketability of the dental handpiece, it is obviously worthy of investigating it. The goal of this paper is to establish the relationship between the air turbine speed and the supply route inside the handpiece. To do this, the Computational Fluid Dynamics(CFD) tool, Fine$^{TM}$/Turbo is used and the optimal supply route position is suggested from the simulation results. In addition, as an attempt for domestic product, the reverse engineering process of a high speed dental handpiece by 3D X-Ray CT equipment and wire cutting is presented for the Mark II model in NSK. In doing so, the 3D modeling of the handpiece parts is carried out with CATIA V5, and the interference between parts is examined. Finally, the result of performance test for the prototype produced in this research is presented.

Structural Design for Vibration Reduction in Brushless DC Stator

  • Jafarboland, Mehrdad;Farahabadi, Hossein Bagherian
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1842-1850
    • /
    • 2017
  • Reducing the noise and vibration of the BLDC motors is very essential for some special applications. In this paper, a new structural design is introduced to increase the natural frequencies of the stator in BLDC motors as increasing the natural frequencies can reduce the severe effects of the structural resonances, including high levels of noise and vibration. The design is based on placing a single hole on definite regions at the stator cross sectional area (each region contains one tooth and its upper parts in the stator yoke) in an optimum way by which the natural frequencies at different modes are shifted to the higher values. The optimum diameter and locations for the holes are extracted by the Response Surface Methodology (RSM) and the modal analyses in the iterative process are done by Finite Element Method (FEM). Moreover, the motor performance by the optimum stator structure is analyzed by FEM and compared with the prototype motor. Preventing the stator magnetic saturation and the motor cogging torque enhancement are the two constraints of the optimization problem. The optimal structural design method is applied experimentally and the validity of the design method is confirmed by the simulated and experimental results.

Morphological multivariate analyses of Isodon excisus complex (Lamiaceae) in Korea

  • Kim, Sang-Tae;Ma, Youn-Ju
    • Korean Journal of Plant Taxonomy
    • /
    • v.41 no.3
    • /
    • pp.223-229
    • /
    • 2011
  • The taxonomy of the Isodon excisus complex has been ambiguous and problematic because the morphological characters, especially characters related to the leaf distinguishing subgroups of the complex in the original descriptions, are variable. To elucidate the taxonomic structure of the I. excisus complex in Korea, 34 characters were measured from 70 OTUs representing different locations and analyzed by principal component analysis (PCA). The analysis showed that principle component axis 1, 2, 3 (PC1, PC2, PC3) represents 52.0% of the total variance and characters showing high loading values for PC1 were leaf shape, density of non-glandular hairs on the lower surface of the leaf, and characters related to the teeth of the leaf. The length of apical tooth and the angle between two widest points of the leaf were highly correlated to PC2 and PC3, respectively. Three-dimensional scatter plotting of OTUs for PC1, PC2, and PC3 axis showed that the areas of previously recognized three subgroups of I. excisus completely overlapped. Our result supported that just one taxon, I. excisus var. excisus, should be recognized in the complex at the variety level.

Chair side measuring instrument for quantification of the extent of a transverse maxillary occlusal plane cant

  • Naini, Farhad B.;Messiha, Ashraf;Gill, Daljit S.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.21.1-21.3
    • /
    • 2019
  • Background: Treatment planning the correction of a transverse maxillary occlusal plane cant often involves a degree of qualitative "eyeballing", with the attendant possibility of error in the estimated judgement. A simple chair side technique permits quantification of the extent of asymmetry and thereby quantitative measurements for the correction of the occlusal plane cant. Methods: A measuring instrument may be constructed by soldering the edge of a stainless steel dental ruler at 90° to the flat surface of a similar ruler. With the patient either standing in natural head position, or alternatively seated upright in the dental chair, and a dental photographic retractor in situ, the flat under-surface of the horizontal part of this measuring instrument is placed on a unilateral segment of a bilateral structure, e.g. the higher maxillary canine orthodontic bracket hook. The vertical ruler is held next to the contralateral canine tooth, and the vertical distance measured directly from the canine bracket to the flat under-surface of the horizontal part of the measuring instrument. Results: This vertical distance quantifies the overall extent of movement required to level the maxillary occlusal plane. Conclusions: This measuring instrument and simple chair side technique helps to quantify the overall extent of surgical levelling required and may be a useful additional technique in our clinical diagnostic armamentarium.

A Histochemical Study of the periodontal Ligament Fibers in Trauma from Occlusion (실험적 외상성교합시 치근막섬유의 조직화학적 관찰)

  • Kim, Woo-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.29-34
    • /
    • 1969
  • Occlusal force is a critical factor affecting the condition and structure of the periodontium. When the occlusal forces exceed the physiologic adaptive capacity of the tissues, tissue damage ensues. Such damage is referred to as trauma from occlusion. Excessive pressure causes compression, degeneration and realignment of the periodontal ligament fibers so that they are paralleled perpendicular to the tooth and bone. By inducing excessive occlusal forces with a high amalgam filling on rat's molar, the author observed histologic alterations of the periodontal ligament fibers by means of Hematoxylin-eosin, Van Gieson and Aldenyde fuchsin stainings. The results of the study were observed as follows: 1) The excessive occlusal forces altered arrangement of the collagenous fibers. 2) The arrangement of the oblique fibers showed appreciable differences between the control group and the group subjected to 10 days experimental trauma from occlusion. 3) The realignment of the transseptal fibers was not found. 4) The arrangement of the oblique fibers after 15 days of trauma from occusion was similar to that of 10 days experimental group. 5) The oxytalan fibers were more abundant at the cementum rather than at the alveolar bone. 6) The excessive occlusal forces produced funnel-shaped widening of the oxytalan fibers, which followed wavy course. 7) The oxytalan fibers appeared to be distributed mainly around the middle third of the root rather than that of the apical third of the root during the experimental trauma from occlusion.

  • PDF