• Title/Summary/Keyword: Tooth Remaining

Search Result 175, Processing Time 0.024 seconds

THE FISSURE PENETRATION AND MICROLEAKAGE OF PIT AND FISSURE SEALANT WITH MECHANICAL PREPARATION (기계적 삭제방법을 이용한 치면열구전색제의 열구 침투도 및 미세누출)

  • Kim, Ji-Yeon;Lee, Jae-Ho;Park, Ki-Tae;Kim, Seong-Oh;Choi, Byung-Jai;Son, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.164-173
    • /
    • 2005
  • Mechanical preparation has been introduced to provide the sealant retention. The objective of this study was to compare the fissure penetration and the microleakage of pit and fissure sealant using mechanical preparation(mechanical preparation + acid etching) and acid etching only. An additional objective of this study was to compare the fissure penetration and the microleakage of unfilled and filled sealant in both methods. Sixty human premolars extracted for orthodontic purpose were selected. Thirty teeth were acid etched alone and remaining thirty teeth were prepared with a $\frac{1}{4}$ round bur and then acid etched. One-half of teeth in each surface treatment method were sealed with unfilled sealant and the other half were sealed with filled sealant. All of the teeth were thermocycled for 1200 cycles at $5^{\circ}C\;and\;55^{\circ}C$ and immersed in 5% methylene blue for 24 hours. Each tooth was sectioned bucco-lingually at mesial pit and distal pit and examined under a Measurescope. In the case of mechanical preparation, fissure penetration of sealant was significantly increased compared with the case of acid etching only(P < 0.05). The filled and unfilled sealant using mechanical preparation showed significantly decreased microleakage when compared with the unfilled sealant using acid etching only(P < 0.05). No differences were found in fissure penetration and microleakage between unfilled and filled sealant in both methods. Taken together, the results of this study suggest that mechanical preparation and filled sealant are recommended when placing pit and fissure sealant. However, further clinical studies should be performed in regard to microleakage.

  • PDF

EFFECT OF ULTRASONIC VIBRATION ON ENAMEL AND DENTIN BOND STRENGTH AND RESIN INFILTRATION IN ALL-IN-ONE ADHESIVE SYSTEMS (All-in-one 접착제에서 초음파진동이 법랑질과 상아질의 결합강도와 레진침투에 미치는 영향)

  • Lee, Bum-Eui;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.66-78
    • /
    • 2004
  • The objective of this study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration in enamel and dentin achieved with those gained using the conventional technique and vibration technique. For enamel specimens, thirty teeth were sectioned mesio-distally. Sectioned two parts were assigned to same adhesive system but different treatment(vibration vs. non-vibration). Each specimen was embedded in 1-inch inner diameter PVC pipe with a acrylic resin. The buccal and lingual surfaces were placed so that the tooth and the embedding medium were at the same level. The samples were subsequently polished silicon carbide abrasive papers. Each adhesive system was applied according to its manufacture's instruction. Vibration groups were additionally vibrated for 15 seconds before curing. For dentin specimen, except removing the coronal part and placing occlusal surface at the mold level, the remaining procedures were same as enamel specimen. Resin composite(Z250. 3M. U.S.A.) was condensed on to the prepared surface in two increments using a mold kit(Ultradent Inc., U.S.A.). Each increments was light cured for 40 seconds. After 24 hours in tap water at room temperature, the specimens were thermocycled for 1000cycles. Shear bond strengths were measured with a universal testing machine(Instron 4465, England). To investigate infiltration patterns of adhesive materials, the surface of specimens was examined with scanning electron microscope. The results were as follows: 1. In enamel the mean values of shear bond strengths in vibration groups(group 2, 4, 6) were greater than those of non-vibration group(group 1, 3, 5). The differences were statistically significant except AQ bond group. 2. In dentin, the mean values of shear bond strengths in vibration groups(group 2, 4, 6) were greater than those of non-vibration groups(group 1, 3, 5). But the differences were not statistically significant except One-Up Bond F group. 3. The vibration group showed more mineral loss in enamel and longer resin tag and greater number of lateral branches in dentin under SEM examination.

  • PDF

A STUDY ON THE EFFECTS OF FINISHING/POLISHING TIMING ON SURFACE FEATURES OF COMPOSITE RESTORATION (연마시기에 따른 복합레진의 표면 특성에 관한 연구)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Park, Eun-Hae;Lee, Young-Jun;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.98-107
    • /
    • 2004
  • Proper finishing/polishing of dental restorations are critical clinical procedures that enhance both esthetics and longevity of restored teeth. This study was to compare the effects of immediate and delayed finishing/polishing procedures on the surface roughness and surface hardness of tooth-colored restoratives including two microfilled composite resins, such as Filtek A110 and Silux Plus, two hybrid composite resins, such as Revolution formular2 and Palfique Estelite. A total of 48 specimens were made for each material. The first 16 specimens served as the control group and the remaining 32 specimens were randomly divided into two equal groups. The control group was stored in distilled water at $37^{\circ}C$ for 1 week after light polymerization against the Mylar sheet. The first experimental group was finished/polished immediately after light polymerization and stored for 1 week in distilled water at $37^{\circ}C$, whereas the while the second group was finished/polished 1 week after light polymerization and stored in distilled water at $37^{\circ}C$. The results were as follows: 1. The smoothest surface was produced by Mylar sheet and finishing/polishing procedure increased the surface roughness. However, the surface roughness of composite resins were not influenced by the finishing/polishing timing. 2. There were significant differences about surface roughness between Revolution formular 2 and Silux Plus, regarding immediate finishing/polishing, and between Palfique Estelite and Silux Plus regarding delayed finishing/polishing(p<0.05). 3. The sequence of the surface hardness was ascending order by Revolution formular 2, Silux Plus, Filtek A110 and Palfique Estelite. However there were no significant differences about hardness among the control group and two finishing/polishing timing groups. 4. The effects of finishing/polishing time on surface roughness and hardness appeared to be material-dependent.

  • PDF

The effect of contamination on bonding of orthodontic brackets with a self-etching prirneriadhesive (Self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 오염이 전단결합강도에 미치는 영향)

  • Kim, Yu-Shin;Lee, Hyung-Soon;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.439-447
    • /
    • 2004
  • The purpose of this study was to investigate the influence of water, saliva and blood contamination on the bonding strength of metal brackets with a self-etching primer/adhesive to enamel. Ninety-six extracted human teeth were divided into four groups. The brackets were bonded to enamel with a self- etching primer (3M/Unitek Dental Products. Monorovia California) according to one of four protocols. The teeth were bonded in a dry condition (group D) or in contamination with distilled water (group W), artificial saliva (group S). or fresh human blood (group B) Shear bond strengths were tested using an Instron Universal testing machine. After debonding. bracket and tooth surfaces were examined with a stereomicroscope. In each group, four samples were selected and examined with a Scanning electron microscope of the prepared enamel surface and resin-enamel interlace. The results obtained were summarized as follows: Shear bond Strength if group D $(15.22{\pm}2.86MPa)$ and W $(15.20{\pm}3.85 MPa)$ Were higher than in group B$(12.56{\pm}2.94MPa)$ (p<0.05). There were no statistical differences in the shear bond strengths between groups D. W and S (p>0.05). There was a tendency to have less residual adhesive remaining on the enamel surfaces of group B than group D. The SEW morphology of group D and W showed a more roughened etching pattern than group S and B. Water or saliva contamination on bending of orthodontic brackets with Transbond plus self etching primer had almost no influence on bond strength In this study, the blood contaminated group showed the lowest bond strength, but it was above the clinically acceptable bond strength (5.9-7.8 MPa, Reynold, 1975). The results of this study suggest that acceptable clinical bond strengths can be obtained in wet conditions when self-etching adhesives are used.

Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system (가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형 상에서 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내면 적합도 비교)

  • Wan-Sun Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.72-81
    • /
    • 2024
  • Purpose: This study aimed to assess the marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures (FPDs) fabricated via computer-aided design and computer-aided manufacturing (CAD/CAM) from solid working casts and removable die system. Materials and Methods: The tooth preparation protocol for a zirconia crown was executed on the mandibular right first premolar and mandibular right first molar, with the creation of a reference cast featuring an absent mandibular right second premolar. The reference cast was duplicated using polyvinyl siloxane impression, from which 20 working casts were fabricated following typical dental laboratory procedures. For comparative analysis, 10 FPDs were produced from a removable die system (RD group) and the remaining 10 FPDs from the solid working casts (S group). The casts were digitized using a dental desktop scanner to establish virtual casts and design the FPDs using CAD. The definitive 3-unit monolithic zirconia FPDs were fabricated via a CAM milling process. The seated FPDs on the reference cast underwent digital evaluation for marginal and internal fit. The Mann-Whitney U test was applied for statistical comparison between the two groups (α = 0.05). Results: The RD group showed significantly higher discrepancies in fit for both premolars and molars compared to the S group (P < 0.05), particularly in terms of marginal and occlusal gaps. Color mapping also highlighted more significant deviations in the RD group, especially in the marginal and occlusal regions. Conclusion: The study found that the discrepancies in marginal and occlusal fits of 3-unit monolithic zirconia FPDs were primarily associated with those fabricated using the removable die system. This indicates the significant impact of the fabrication method on the accuracy of FPDs.