• Title/Summary/Keyword: Tooth, Extraction

Search Result 642, Processing Time 0.027 seconds

The Gingival Tissue Levels of Bone Resorptive Mediators in Human Chronic Periodontitis with Type 2 Diabetes Mellitus (2형 당뇨병환자의 만성 치주염 치은조직에서 골흡수 인자의 발현 양상 비교)

  • Kim, Mi-Jung;Ryu, Sang-Ho;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.743-753
    • /
    • 2007
  • Purpose: The purposes of this study were to compare and quantify the expression of MMP-3, $PGE_2$ and IL-6 in the gingival tissues of patients with $type_2$ diabetes mellitus and healthy adults with chronic periodontitis. Material and methods: Gingival tissue samples were obtained during periodontal surgery or tooth extraction. According to the patient's systemic condition & clinical criteria of gingiva, each gingival sample was devided into three groups. Group 1(n=8) is clinically healthy gingiva without bleeding and no evidence of bone resorption or periodontal pockets, obtained from systemically healthy 8 patients. Group 2(n=8) is inflamed gingiva from patients with chronic periodontitis. Group 3(n=8) is inflamed gingiva from patients with chronic periodontitis associated with type 2 DM. Tissue samples were prepared and analyzed by Westernblotting. The quantification of MMP-3, $PGE_2$ and IL-6 were performed using a densitometer and statistically analyzed by one-way ANOVA followed by Tukey test. Results: 1. The expression levels of MMP-3 were shown highest in group 3 compared to group 1 and 2, and It showed increasing tendency in group 2 and 3. 2. The expressions of $PGE_2$ and IL-6 were shown increasing tendency in group 2 and 3, and It was highest in group 3. 3. As expressions of MMP-3 were increased, $PGE_2$ and IL-6 expressions showed increasing tendency in group 3 than group1 and 2, although there were no proportional relationship. Conclusion: This study demonstrated that the expression levels of MMP-3, $PGE_2$ and IL-6 will be inflammatory markers of periodonta linflamed tissue and DM. It can be assumed that MMP-3 affect to expressions of $PGE_2$ and IL-6 in progression of periodontal inflammation with alveolar bone resorption to type 2 DM.

The Influence of Diabetes on of $PGE_2$, MMP-14 and TIMP Expressions in Human Chronic Periodontitis (만성 치주염 환자에서 2형 당뇨병이 $PGE_2$, MMP-14 및 TIMP의 발현양상에 미치는 영향)

  • Kim, Seon-Woo;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.755-766
    • /
    • 2007
  • Purpose: The purposes of this study were to compare and quantify the expression of $PGE_2$, MMP-14 and TIMP-1 in the gingival tissues of patients with type 2 diabetes mellitus and healthy adults of chronic periodontitis with alveolar bone resorption. Material and methods: Gingival tissue samples were obtained during periodontal surgery or tooth extraction. According to the patient's systemic condition & clinical criteria of gingiva, each gingival sample was devided into three groups. Group 1 (n=8) is clinically healthy gingiva without bleeding and no evidence of bone resorption or periodontal pockets, obtained from systemically healthy 8 patients. Group 2 (n=8) is inflammed gingiva from patients of chronic periodontitis with alveolar bone resorption. Group 3(n=8) is inflammed gingiva from patients of chronic periodontitis with alveolar bone resorption associated with type 2 diabetes. Tissue samples were prepared and analyzed by Western blotting. The quantification of $PGE_2$ MMP-14 and TIMP-1 were performed using a densitometer and statistically analyzed by one-way ANOVA followed by Tukey test. Results: The expressions of MMP-14 and TIMP-1 were showed increasing tendency in group 2 & 3 compared to group 1. The expressions of $PGE_2$, MMP-14 were showed increasing tendency in group 3 compared to group 1 and group 2. According to MMP-14 levels were increasing, $PGE_2$ showed increasing tendency in group 3, and although $PGE_2$, MMP-14 levels were increasing, TIMP-1 levels were similar expressed comparing to group 2. Conclusion: In conclusion, this study demonstrated that the expression levels of MMP-14 and TIMP-1 had increasing tendency in inflammed tissue. It can be assumed that $PGE_2$ and MMP-14 may be partly involved in alveolar bone resorptive process and the progression of periodontal inflammation associated to type 2 DM.

Syncope and pneumomediastinum during the maxillary sinus elevation with an air-syringe: a case report (주사기를 이용한 상악동 거상술 시 발생한 실신 및 종격동기종에 관한 증례보고)

  • Kim, Su Wan;Lee, Jonggeun;Song, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.171-176
    • /
    • 2021
  • Pneumomediastinum is a very rare and potentially catastrophic complication of dental procedures. Its common causes are tooth extraction, endodontic treatment, and subgingival curettage using handpieces and high-pressure air/water syringes. We present a case of massive pneumomediastinum with subcutaneous emphysema in a 61-year-old female who underwent bone grafting into the maxilla for pretreatment of dental implantation using a syringe. The patient suffered from abrupt severe odynophagia and loss of consciousness. The patient transferred to emergency department and images work-up revealed a pneumomediastinum and subcutaneous emphysema on the entire face and neck. We performed conservative treatments including prophylactic antibiotics, oxygen inhalation, and fasting meals, and then discharge after 7 days uneventfully. The patient's syncope might be resulting from hypotension and pain shock induced by pneumomediastinum with a sudden chest compression. The pneumomediastinum could be resulting from concurrent perforation and massive air infiltration into the maxillary sinus during bone grafting. We suggest that pneumomediastinum needs prompt diagnosis and management because of the risk of airway obstruction when a patient present syncope in the dental room.

Fabrication of removable partial denture on scleroderma patient using 3-dimensional intraoral scanner (전신성 피부경화증 환자에서의 3차원 구강스캐너를 이용한 가철성 국소의치 제작 증례)

  • Kim, Ung-Gyu;Han, Jung-Suk;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.116-125
    • /
    • 2021
  • A three-dimensional (3D) intraoral scanner, which is one of the major developments in digital dentistry, is widely used in fixed prosthodontics. The application of intraoral scanner is now increasing in removable prosthodontics. Sclerotic change induced by scleroderma causes the limitation of mouth opening and multiple loss of the teeth. Conventional prosthodontic procedures are challenging for patients with this disease. This study showed a case of digital approach to the removable prosthodontic treatment of a patient who had the scleroderma and the consequent microstomia. At the provisional stage, the optical impression of patient's oral structures was digitally obtained. Using a 3D printer, the provisional dentures were fabricated. After extraction of hopeless tooth, the definitive digital impression was taken and the metal frameworks were fabricated, based on the data acquired from the impression. The definitive removable partial dentures were completed and delivered to the patient, who was satisfied with the prostheses.

Aesthetic implant restoration with alveolar bone graft and digital method on maxillary central incisor: a case report (치조골이식과 디지털 방법을 활용한 상악 중절치 임플란트 심미 수복 증례)

  • Jang, Han-Sol;Pyo, Se-Wook;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.168-174
    • /
    • 2022
  • In case of gingival recession or bone defect in maxillary anterior implant treatment, it is not easy to obtain satisfactory clinical results. In this case, loss of the labial alveolar plate was diagnosed in the maxillary right central incisor, so after tooth extraction, soft tissue was secured and implant placement with bone graft was planned. In addition, digital guide surgery was performed for the ideal implant position, and GBR (Guided Bone Regeneration) was accompanied with the xenogeneic bone and the autologous bone collected from the mandibular ramus since alveolar bone defects were extensive. After a sufficient period of osseointegration of the implant, a temporary prosthesis was fabricated through secondary stage surgery and impression taking, and through periodic external adjustment, the shape of soft tissue was improved. In the final prosthesis fabrication, a color tone of natural teeth was induced by an gold anodized customized abutment, and an aesthetic and functional zirconia prosthesis with reproducing the shape of the temporary prosthesis through intraoral scan was delivered.

Impact of lattice versus solid structure of 3D-printed multiroot dental implants using Ti-6Al-4V: a preclinical pilot study

  • Lee, Jungwon;Li, Ling;Song, Hyun-Young;Son, Min-Jung;Lee, Yong-Moo;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.4
    • /
    • pp.338-350
    • /
    • 2022
  • Purpose: Various studies have investigated 3-dimensional (3D)-printed implants using Ti6Al-4V powder; however, multi-root 3D-printed implants have not been fully investigated. The purpose of this study was to explore the stability of multirooted 3D-printed implants with lattice and solid structures. The secondary outcomes were comparisons between the 2 types of 3D-printed implants in micro-computed tomographic and histological analyses. Methods: Lattice- and solid-type 3D-printed implants for the left and right mandibular third premolars in beagle dogs were fabricated. Four implants in each group were placed immediately following tooth extraction. Implant stability measurement and periapical X-rays were performed every 2 weeks for 12 weeks. Peri-implant bone volume/tissue volume (BV/TV) and bone mineral density (BMD) were measured by micro-computed tomography. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were measured in histomorphometric analyses. Results: All 4 lattice-type 3D-printed implants survived. Three solid-type 3D-printed implants were removed before the planned sacrifice date due to implant mobility. A slight, gradual increase in implant stability values from implant surgery to 4 weeks after surgery was observed in the lattice-type 3D-printed implants. The marginal bone change of the surviving solid-type 3D-printed implant was approximately 5 mm, whereas the value was approximately 2 mm in the lattice-type 3D-printed implants. BV/TV and BMD in the lattice type 3D-printed implants were similar to those in the surviving solid-type implant. However, BIC and BAFO were lower in the surviving solid-type 3D-printed implant than in the lattice-type 3D-printed implants. Conclusions: Within the limits of this preclinical study, 3D-printed implants of double-rooted teeth showed high primary stability. However, 3D-printed implants with interlocking structures such as lattices might provide high secondary stability and successful osseointegration.

Dental Surgery Simulation Using Haptic Feedback Device (햅틱 피드백 장치를 이용한 치과 수술 시뮬레이션)

  • Yoon Sang Yeun;Sung Su Kyung;Shin Byeong Seok
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.6
    • /
    • pp.275-284
    • /
    • 2023
  • Virtual reality simulations are used for education and training in various fields, and are especially widely used in the medical field recently. The education/training simulator consists of tactile/force feedback generation and image/sound output hardware that provides a sense similar to a doctor's treatment of a real patient using real surgical tools, and software that produces realistic images and tactile feedback. Existing simulators are complicated and expensive because they have to use various types of hardware to simulate various surgical instruments used during surgery. In this paper, we propose a dental surgical simulation system using a force feedback device and a morphable haptic controller. Haptic hardware determines whether the surgical tool collides with the surgical site and provides a sense of resistance and vibration. In particular, haptic controllers that can be deformed, such as length changes and bending, can express various senses felt depending on the shape of various surgical tools. When the user manipulates the haptic feedback device, events such as movement of the haptic feedback device or button clicks are delivered to the simulation system, resulting in interaction between dental surgical tools and oral internal models, and thus haptic feedback is delivered to the haptic feedback device. Using these basic techniques, we provide a realistic training experience of impacted wisdom tooth extraction surgery, a representative dental surgery technique, in a virtual environment represented by sophisticated three-dimensional models.

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON PRODUCED DURING RETRACTION OF FOUR MAXILLARY INCISORS (상악 4절치의 후방견인시 나타나는 현상에 관한 유한요소법적 분석)

  • Cheon, Ok-Jin;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.525-541
    • /
    • 1995
  • This study was designed to investigate force systems and tooth movements produced by retraction archwire during retraction of four maxillary incisors after the maxillary canine retraction into the maxillary first premolar extraction space using the computer-aided three-dimensional finite element method. A three-dimensional finite element model, consisting of 2248 elements and 3194 nodes, was constructed. The model consisted of maxillary teeth and surrounding periodontal membranes, .022'$\times$.028'-slot brackets, and 5 types of retraction archwires(.019'$\times$.025' stainless steel archwire) modeled using the beam elements. The contact between the wire and the bracket slot was modeled using the gap elements because of the non-linear elastic behaviors of the contact between them. The forces and moments, End displacements produced by retraction archwire were measured at various conditions to investigate the difference according to types of loops, magnitudes of activation force, gable angle, and anterior lingual root torque. The results were expressed quantitative and visual ways in the three-dimensional method. The following conclusions can be drawn from this study.1. When the tear-drop loop archwire was activated, the mesio-distal and lingual translational movements of the teeth helped to close the extraction space, but unwanted movements of the teeth including intrusions and extrusions, and rotational movements in each direction occurred. 2. Activation of T-loop archwire compared with those of other types of retraction archwires produced the least translational movements of the teeth helped to space closure and also the least unwanted movements of the teeth. 3. Increasing amount of activation in the tear-drop archwire led not only to increase of translational movements of the teeth helped to space closure, but also to increase of unwanted movements of the teeth. 4. Addition of gable bend in the tear-drop archwire helped anterior teeth to translational movements in the mesio-distal direction, but increased unwanted movements of the teeth 5. Addition of anterior lingual root torque in the tear-drop archwire helped central and lateral incisor to improve their facio-lingual inclination, but increased unwanted movements of the teeth.

  • PDF

Retrospective study on three-dimensional characteristics of mesiodens using CBCT in pediatric dentistry (치과용 Cone-beam CT를 이용한 상악 정중과잉치의 3차원적 특성에 관한 후향적 연구)

  • Ryu, GiYoun;Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Young-Jae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.77-94
    • /
    • 2021
  • The purpose of this study was to investigate the three-dimensional characteristics of mesiodens using Cone-beam Computed Tomography(CBCT) and analyze the factors affecting complications and anesthetic methods of extraction. This study evaluated 602 mesiodens of 452 patients who underwent extraction of mesiodens at the department of Pediatric Dentistry in Seoul National University Dental Hospital between 2017 and 2019. The ratio of mesiodens patients over total patient per year was gradually increased over the past 20 years. Mesiodens with labio-palatally horizontal direction while root directing labial were the most common among the mesiodens with horizontal direction. Mesiodens were the most common at the cervical side of the adjacent teeth(37.0%) and mesiodens located in the near-palatal side were observed about 3.83 times higher than the far-palatal side. Most of the mesiodens(82.1%) were in contact with adjacent permanent teeth on all three sides of the CBCT and 46.2% of mesiodens had curved roots. The patient's age, vertical position, presence of complications, and proximity showed a significant difference in the selection of general anesthesia among anesthetic methods. The direction and vertical position of mesiodens had a significant effect on complications. These results provide a better understanding of mesiodens for establishing an accurate diagnosis and treatment plan.

An evaluation of the adequacy of pont's index (Pont 지수의 임상적 적합성에 대한 평가)

  • Kim, Seong-Hun;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.115-126
    • /
    • 2000
  • Dental arch expansion is one of the method used to solve the dental crowding problem by non-extraction. Many formulae using tooth size have been suggested to predict ideal inter-premolar and inter-molar width. The purpose of this study was to evaluate the adequacy of some upper dental arch width prediction methods, namely Pont's method, Schmuth's method and Cha's method. The sample consisted of the casts of 119 Korean young adults who had no muscular abnormality, no skeletal discrepancy, and Angle's Class I molar relationships. Measurements were obtained directly from plaster casts; they Included mesiodistal crown diameters of the four maxillary incisors, as well as maxillary inter-first-premolar and inter-first-molar arch widths as specified by Pont. The correlation coefficients between the sum of incisors(SI) and upper dental arch width were calculated. The differences between predicted width and actual width were classified as overestimated, properestimated, and underestimated. The data obtained from each group were analyzed for statistical differences. The results were as follows : 1. Upper dental arch width indices were calculated from SI in normal occlusion (81.96 : premolar index, 62.55 : molar index). 2. Low correlations between SI and arch width were noted in normal occlusion (0.50 in the inter-premolar width, 0.39 in the inter-molar width). 3. Pont's formula and Schmuth's formula tended to overestimate the inter-premolar width. A more even distribution of estimates was noted in Cha's fomula. 4. Cases within $\pm$1 mm range of observed inter-premolar width were $45\%$ in the Cha's formula, $40\%$ in the Pont's formula, and $39\%$ in the Schmuth's formula. 5. All formulae had a tendency to underestimate the inter-molar width, but Cha's formula had better predictability than others. 6. Cases within $\pm$1 mm range of observed inter-molar width were $40\%$ in the Cha's formula, $29\%$ in the Pont's formula, and $13\%$ of Schmuth's formula. The data presented in this study does not support the clinical usefulness of ideal arch width prediction methods using the mesiodistal width of maxillary incisors.

  • PDF