• 제목/요약/키워드: Tool shoulder

검색결과 125건 처리시간 0.02초

Al 5083O합금의 마찰교반용접부의 조직과 특성평가 (Mechanical Characteristics and Macro-and Micro-structures on Friction Stir Welded Joints with 5083O Al Alloys)

  • 장석기;박종식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.104-111
    • /
    • 2009
  • This paper shows the behaviors of macro- and micro-structures and mechanical properties for specimen's welding region welded by FSW. according to welding conditions with 5mm thickness aluminum 5083O alloy plate. It apparently results in defect-free weld zone in case traverse speed was changed to 32 mm/min under conditions of anti-clockwise direction and tool rotation speed such as 800 and 1250 rpm with tool's pin diameter of 5 ${\Phi}mm$ and shoulder diameter of 20 ${\Phi}mm$, pin length of 4.5 mm and tilting angle of $2^{\circ}$. The ultimate stress of ${\sigma}_T=331$ MPa and the yield point of 147 MPa are obtained at the condition of the travel speed of 32 mm/min with the tool rotation speed of 1250 rpm. There is neither voids nor cracks on bended surface of $180^{\circ}$ after bending test. The improvement of toughness after impact test was found. The lower rotating and traverse speed became, the higher were yield point, maximum stress and elongation(%) with the stresses and the elongation(%) versus the traverse speed diagram. Vickers hardness for cross section of welding zone were also presented. The typical macro-structures such as dynamically recrystallized zone, thermo-mechanically affected zone and heat affected zone and the micro-structures of the transverse cross-section were also showed. However, the author found out that the region of 6mm far away from shoulder circumference was affected by friction heat comprehensively, that is, hardness softened and that part of micro-structures were re-solid-solution or recrystallized, the author also knew that there is no mechanically deformation on heat affected zone but there are the flow of plastic deformation of $45^{\circ}$ direction on thermo-mechanically affected zone and the segregation of Al-Mg on nugget. The solid solution wt(%) of parent material as compared against of friction stir welded zone was comprehensively changed.

회전근개 파열 환자의 옷입고 벗기 향상을 위해 ICF Tool을 적용한 PNF 중재전략 : 증례보고 (A PNF Intervention Strategy with ICF Tool Applied for Improvement of Dressing in a Patient with Rotator Cuff Syndrome : A Case Report)

  • 김진철;이정아
    • 대한물리의학회지
    • /
    • 제13권3호
    • /
    • pp.49-60
    • /
    • 2018
  • PURPOSE: This study was conducted to investigate the intervention effect obtained by applying an ICF tool to improve the dressing in a patient with rotator cuff syndrome to schematize the problems and approaching with PNF to solve the problems. METHODS: The subject of this study was a 44-year-old patient who underwent surgery after complete right rotator cuff tear. To treat his symptoms, the processes of clinical practice were implemented in the order of examination, assessment, diagnosis, prognosis, intervention, and outcome. During examination, patient information was collected using the ICF core set. In the assessment, the problems were schematized, and an ICF assessment sheet was used to identify the interaction of the problems. The diagnosis was made by clearly describing the causal relationship derived from the assessment in ICF terms. To solve the problems, the intervention was given in the order of indirect, direct, and task based on the philosophy of PNF. To evaluate the outcome, the differences before and after the intervention were compared. Additionally, the comparison for the ICF qualifier is presented with the ICF evaluation display. RESULTS: The results of the study showed clinical advantages in shoulder strength, eccentric control, range of motion, scapular stability, and shoulder pain. Overall, our patient with rotator cuff syndrome showed improvement in dressing and undressing activity in response to the PNF strategy. CONCLUSION: Application of the PNF intervention strategy after complete rotator cuff tear would have a positive effect on patient upper extremity function.

원형치수 계산도구에 의한 바디스 원형 평가 연구 (A Study on Basic Pattern Evaluations Utilizing a Bodice Sloper Size Measurement Tool)

  • 홍지운;권숙희
    • Human Ecology Research
    • /
    • 제54권4호
    • /
    • pp.427-440
    • /
    • 2016
  • This study uses comparison tests of bodice basic patterns to research improvements in wearing evaluation methods based on differences in bodice basic patterns and body size. As study methods, we calculated body sizes for six types by selecting four types of bodice basic pattern and utilized bodice basic pattern size measurement tools. The study result are as follows. First, as the result of analyzing bodice basic patterns per each part and body size difference by bodice basic pattern size measurement tool, shoulder angle cover rate was J&K type 57.57%~68.41%, N type 53.13%~65.57%, L type 51.87%~63.73%, and H type 59.03%~68.20%. In the item of neck base circumference, it was J&K type 6.4~-16 mm, N type 10.7~-31.9 mm, L type -5.2~-13.4 mm, and H type -6.2~-15.4 mm. In the item of armscye circumference, it was J&K type -18.9~-59.4 mm, N type -15.2~-51.3 mm, L type -38.9~-52.7 mm, and H type -17~-42.2 mm. In the item of biacromion length, it was J&K type 23.2~-4.7 mm, N type 18.4~-10.4 mm, and H type 3.5~-5.7 mm. In the item of interscye back, it was J&K type and N type 17.6~-13.6 mm, L type 11.9~-13.6 mm, and H type 3.2~-11.8 mm. The item of interscye front was found in the sequences of study type and L type. Second, the Kruskal-Wallis test result (according to bodice basic pattern) indicated meaningful differences in items of shoulder angle cover rate, neck point to breast point, bust point-bust point, biacromion length and armscye circumference and H type had an overall higher rank.

축대칭 다단계 딥드로잉 공정의 성형인자에 대한 연구 (A Study on the Formability Factors of Axisymmetric Multi-Stage Deep Drawing Processes)

  • 여은구;조선형;이용신
    • 한국공작기계학회논문집
    • /
    • 제11권4호
    • /
    • pp.6-11
    • /
    • 2002
  • Formability in deep drawing process depends not only on a drawability of workpiece material but also on process conditions such as die punch comer radius, lubricant conditions, punch-die clearance etc. For instance, bending resistance should be reduced by increasing die round appropriately, drawing load should be minimized by improving the lubricant condition between die and material, and blanking load should be increased by selecting a pertinent punch round and by augmenting the friction resistance in punch. In this study, a multi-stage deep drawing process is analyzed using ABAQUS. The effects of formability factors, such as die shoulder radius, punch-die clearance and friction coefficient are investigated, and the results are also discussed in detail.

축대칭 다단계 딥드로잉 공정의 성형인자에 대한 연구 (A Study on the Formability Factors of Axisymmetric Multi-Stage Deep Drawing Processes)

  • 여은구;조선형;이용신
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.280-285
    • /
    • 2001
  • A good drawability of material itself is required. To improve the formability in deep drawing process. Besides that bending resistance should be reduced by increasing die round appropriately, drawing load should be minimized by improving the lubricant condition between die and material, and breaking load should be increased by selecting a pertinent punch round and by augmenting the friction resistance in Punch. In this study, a multi-stage deep drawing process is analyzed using ABAQUS, the effects of formability factors. Such as die shoulder radius, punch-die clearance and friction coefficient are investigated.

  • PDF

분절성 신경근병성 모델과 자극요법 (Segmental Radiculopathic Model and Stimulation Therapy)

  • 안강;이영진
    • Clinics in Shoulder and Elbow
    • /
    • 제6권2호
    • /
    • pp.115-126
    • /
    • 2003
  • Although painful conditions of varying degrees of severity involving the soft tissues (i .e., muscles, tendons, ligaments, periosteum and peripheral nerves) occur frequently, their underlying pathogenesis is poorly understood. The term peripheral neuropathic pain has recently been suggested to embrace the combination of positive and negative symptoms in patients whose pain is due to pathological changes or dysfunction in peripheral nerves or nerve root. The spinal nerve root, because of its vulnerable position, is very easily prone to injury from pressure, stretch, angulation, and friction. Therefore, not a few of musculoskeletal chronic pains are result of nerve root dysfunction. Neuropathic changes due to nerve root dysfunction are primarily in soft tissue especially muscle, tendon and joint. It shows tenderness over muscle motor points and palpable muscle contracture bands and restricted Joint range. Careful palpation and physical examination is the important tool that, be abne to detect all of these phenomena.

회전근개 파열의 수술적 치료 후 회전근개 초음파 소견 (Postoperative Ultrasound Findings of the Rotator Cuff Tendon after Arthroscopic Repair of a Rotator Cuff Tear)

  • 권동락
    • Clinical Pain
    • /
    • 제19권2호
    • /
    • pp.64-69
    • /
    • 2020
  • Ultrasound (US) imaging is an efficient, easy to use, rapid, dynamic, noninvasive, with rare side-effects and inexpensive tool allowing for facilitated diagnosis and management of the painful shoulder. It also has advantages over other imaging modalities in the evaluation of the postoperative shoulder for rotator cuff integrity and correct anchor and suture placement, as well as rotator cuff analysis following repair surgery. Early postoperative tendons frequently had a hypo- echoic echo texture and the absence of a fibrillar pattern, which might be misinterpreted as recurrent tears. however, these features often normalized into tendons with an increased echo texture and the reappearance of a fibrillar pattern at 6 months. Based on these sequential findings, the US findings within 3 months after surgery should be interpreted with caution to accurately understand and monitor the repaired tendon status.

1050 Al판재의 핀 마찰 교반용접에 의한 실험적 연구 (Weldability and properties of lap joints by pin FSW with 1050 Al sheet)

  • 장석기;박종식;한민수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권4호
    • /
    • pp.394-400
    • /
    • 2007
  • The properties and weldability of lap joints by PFSW with 1050 Al sheet was investigated according to tool shape. dimension and welding condition. Tensile shear test was carried out for lap jointed specimen, and the hardness in the joint regions was examined. Moreover interfacial joining length, metallograph and failure location of the lap-jointed cross section were discussed. Two tool types were a simple cylindrical type and a notched cylindrical type. Under joining conditions such as plunging depth of 2.2mm. rotating speed of 1600rpm and dwelling time of 3s, the tensile shear strength of lap-jointed specimen by the notched type tool was superior to that by simple cylindrical type tool. The maximum tensile shear load of lap jointed specimen was 5807N. Optimal dimensions of the notched type tool were as follows : diameters of the shoulder and pin were $18{\phi}mm$ and $10{\phi}mm$, and pin length was 2.2mm.

Application of AutoFom III equipment for prediction of primal and commercial cut weight of Korean pig carcasses

  • Choi, Jung Seok;Kwon, Ki Mun;Lee, Young Kyu;Joeng, Jang Uk;Lee, Kyung Ok;Jin, Sang Keun;Choi, Yang Il;Lee, Jae Joon
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제31권10호
    • /
    • pp.1670-1676
    • /
    • 2018
  • Objective: This study was conducted to enable on-line prediction of primal and commercial cut weights in Korean slaughter pigs by AutoFom III, which non-invasively scans pig carcasses early after slaughter using ultrasonic sensors. Methods: A total of 162 Landrace, Yorkshire, and Duroc (LYD) pigs and 154 LYD pigs representing the yearly Korean slaughter distribution were included in the calibration and validation dataset, respectively. Partial least squares (PLS) models were developed for prediction of the weight of deboned shoulder blade, shoulder picnic, belly, loin, and ham. In addition, AutoFom III's ability to predict the weight of the commercial cuts of spare rib, jowl, false lean, back rib, diaphragm, and tenderloin was investigated. Each cut was manually prepared by local butchers and then recorded. Results: The cross-validated prediction accuracy ($R^2cv$) of the calibration models for deboned shoulder blade, shoulder picnic, loin, belly, and ham ranged from 0.77 to 0.86. The $R^2cv$ for tenderloin, spare rib, diaphragm, false lean, jowl, and back rib ranged from 0.34 to 0.62. Because the $R^2cv$ of the latter commercial cuts were less than 0.65, AutoFom III was less accurate for the prediction of those cuts. The root mean squares error of cross validation calibration (RMSECV) model was comparable to the root mean squares error of prediction (RMSEP), although the RMSECV was numerically higher than RMSEP for the deboned shoulder blade and belly. Conclusion: AutoFom III predicts the weight of deboned shoulder blade, shoulder picnic, loin, belly, and ham with high accuracy, and is a suitable process analytical tool for sorting pork primals in Korea. However, AutoFom III's prediction of smaller commercial Korean cuts is less accurate, which may be attributed to the lack of anatomical reference points and the lack of a good correlation between the scanned area of the carcass and those traits.

The Effectiveness of Infrared Thermography in Patients with Whiplash Injury

  • Lee, Young Seo;Paeng, Sung Hwa;Farhadi, Hooman F.;Lee, Won Hee;Kim, Sung Tae;Lee, Kun Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권4호
    • /
    • pp.283-288
    • /
    • 2015
  • Objective : This study aims to visualize the subjective symptoms before and after the treatment of whiplash injury using infrared (IR) thermography. Methods : IR thermography was performed for 42 patients who were diagnosed with whiplash injury. There were 19 male and 23 female patients. The mean age was 43.12 years. Thermal differences (${\Delta}T$) in the neck and shoulder and changes in the thermal differences (${\Delta}dT$) before and after treatment were analyzed. Pain after injury was evaluated using visual analogue scale (VAS) before and after treatment (${\Delta}VAS$). The correlations between ${\Delta}dT$ and ${\Delta}VAS$ results before and after the treatment were examined. We used Digital Infrared Thermal Imaging equipment of Dorex company for IR thermography. Results : The skin temperature of the neck and shoulder immediately after injury showed $1-2^{\circ}C$ hyperthermia than normal. After two weeks, the skin temperature was normal range. ${\Delta}T$ after immediately injuy was higher than normal value, but it was gradually near the normal value after two weeks. ${\Delta}dT$ before and after treatment were statistically significant (p<0.05). VAS of the neck and shoulder significantly reduced after 2 week (p=0.001). Also, there was significant correlation between ${\Delta}dT$ and reduced ${\Delta}VAS$ (the neck; r=0.412, p<0.007) (the shoulder; r=0.648, p<0.000). Conclusion : The skin temperature of sites with whiplash injury is immediately hyperthermia and gradually decreased after two weeks, finally it got close to normal temperature. These were highly correlated with reduced VAS. IR thermography can be a reliable tool to visualize the symptoms of whiplash injury and the effectiveness of treatment in clinical settings.