• 제목/요약/키워드: Tool Paths

검색결과 170건 처리시간 0.028초

중년후기 여성의 건강증진행위 모형구축 (A Model for Health Promoting Behaviors in Late-middle Aged Woman)

  • 박재순
    • 여성건강간호학회지
    • /
    • 제2권2호
    • /
    • pp.298-331
    • /
    • 1996
  • Recent improvements in living standard and development in medical care led to an increased interest in life expectancy and personal health, and also led to a more demand for higher quality of life. Thus, the problem of women's health draw a fresh interest nowadays. Since late-middle aged women experience various physical and socio-psychological changes and tend to have chronic illnesses, these women have to take initiatives for their health control by realizing their own responsibility. The basic elements for a healthy life of these women are understanding of their physical and psychological changes and acceptance of these changes. Health promoting behaviors of an individual or a group are actions toward increasing the level of well-being and self-actualization, and are affected by various variables. In Pender's health promoting model, variables are categorized into cognitive factors(individual perceptions), modifying factors, and variables affecting the likelihood for actions, and the model assumes the health promoting behaviors are affected by cognitive factors which are again affected by demographic factors. Since Pender's model was proposed based on a tool broad conceptual frame, many studies done afterwards have included only a limited number of variables of Pender's model. Furthermore, Pender's model did not precisely explain the possibilities of direct and indirect paths effects. The objectives of this study are to evaluate Pender's model and thus propose a model that explains health promoting behaviors among late-middle aged women in order to facilitate nursing intervention for this group of population. The hypothetical model was developed based on the Pender's health promoting model and the findings from past studies on women's health. Data were collected by self-reported questionnaires from 417 women living in Seoul, between July and November 1994. Questionnaires were developed based on instruments of Walker and others' health promotion lifestyle profile, Wallston and others' multidimensional health locus of control, Maoz's menopausal symptom check list and Speake and others' health self-rating scale. IN addition, items measuring self-efficacy were made by the present author based on past studies. In a pretest, the questionnaire items were reliable with Cronbach's alpha ranging from .786 to .934. The models for health promoting behaviors were tested by using structural equation modelling technique with LISREL 7.20. The results were summarized as follows : 1. The overall fit of the hypothetical model to the data was good (chi-square=4.42, df=5, p=.490, GFI=.995, AGFI=.962, RMSR=.024). 2. Paths of the model were modified by considering both its theoretical implication and statistical significance of the parameter estimates. Compared to the hypothetical model, the revised model has become parsimonious and had a better fit to the data (chi-square =4.55, df=6, p=.602, GFI=.995, AGFI=.967, RMSR=.024). 3. The results of statistical testing were as follows : 1) Family function internal health locus of control, self-efficacy, and education level exerted significant effects on health promoting behaviors(${\gamma}_{43}$=.272, T=3.714; ${\beta}_[41}$=.211, T=2.797; ${\beta}_{42}$=.199, T=2.717; ${\gamma}_{41}$=.136, T=1.986). The effect of economic status, physical menopausal symptoms, and perceived health status on health promoting behavior were insignificant(${\gamma}_{42}$=.095, T=1.456; ${\gamma}_{44}$=.101, T=1.143; ${\gamma}_{43}$=.082, T=.967). 2) Family function had a significance direct effect on internal health locus of control (${\gamma}_{13}$=.307, T=3.784). The direct effect of education level on internal health locus of control was insignificant(${\gamma}_{11}$=-.006, T=-.081). 3) The directs effects of family functions & internal health locus of control on self-efficacy were significant(${\gamma}_{23}$=.208, T=2.607; ${\beta}_{21}$=.191, T=2.2693). But education level and economic status did not exert a significant effect on self-efficacy(${\gamma}_{21}$=.137, T=1.814; ${\beta}_{22}$=.137, T=1.814; ${\gamma}_{22}$=.112, T=1.499). 4) Education level had a direct and positive effect on perceived health status, but physical menopausal symptoms had a negative effect on perceived health status and these effects were all significant(${\gamma}_{31}$=.171, T=2.496; ${\gamma}_{34}$=.524, T=-7.120). Internal health locus and self-efficacy had an insignificant direct effect on perceived health status(${\beta}_{31}$=.028, T=.363; ${\beta}_{32}$=.041, T=.557). 5) All predictive variables of health promoting behaviors explained 51.8% of the total variance in the model. The above findings show that health promoting behaviors are explained by personal, environmental and perceptual factors : family function, internal health locus of control, self-efficacy, and education level had stronger effects on health promoting behaviors than predictors in the model. A significant effect of family function on health promoting behaviors reflects an important role of the Korean late-middle aged women in family relationships. Therefore, health professionals first need to have a proper evaluation of family function in order to reflect the family function style into nursing interventions and development of strategies. These interventions and strategies will enhance internal health locus of control and self-efficacy for promoting health behaviors. Possible strategies include management of health promoting programs, use of a health information booklets, and individual health counseling, which will enhance internal health locus of control and self-efficacy of the late-middle aged women by making them aware of health responsibilities and value for oneself. In this study, an insignificant effect of physical menopausal symptoms and perceived health status on health promoting behaviors implies that they are not motive factors for health promoting behaviors. Further analytic researches are required to clarify the influence of physical menopausal symptoms and perceived health status on health promoting behaviors with-middle aged women.

  • PDF

품패자산조성부분간적상호관계(品牌资产组成部分间的相互关系): 관우산품충류조절작용적탐색연구(关于产品种类调节作用的探索研究) (Relationships among Brand Equity Components: An Exploratory Study of the Moderating Role of Product Type)

  • Moon, Byeong-Joon;Park, Won-Kyu;Choi, Sang-Chul
    • 마케팅과학연구
    • /
    • 제20권1호
    • /
    • pp.98-109
    • /
    • 2010
  • 对于品牌资产的组成, 测量和管理的研究开始于David A.Aaker (1991) 和Kevin Lane Keller(1993). 最近, 很多的研究都集中于品牌资产的组成: 品牌意识, 质量预期, 产品形象和品牌忠诚度. 本文主要针对于这些成分间相互关系, 而且特别主意产品种类(实用或者享受)的调节作用. 基于以上所提及的关系所建立的模型可以参看图1. 本文的假设如下: 顾客的品牌意识对于顾客的忠诚度和品牌形象有积极的影响; 顾客的质量预期对于品牌忠诚度和品牌形象有积极的影响; 品牌形象对于品牌忠诚度有积极影响; 这些品牌资产成分间的关系可以被产品种类所调节. 具体说明就是, 对于实用性产品, 质量预期对于品牌忠诚度的作用会增强, 而对于享受产品品牌形象对于品牌忠诚度的作用会更强. 为了确定适用于本研究的产品, 58名首尔的大学生参加了前测. 结果是计算机被选择成为实用性产品, 而牛仔裤被选定成为享受产品. 每一种产品各选择了两个品牌: 三星和惠普以及李维斯和NIX. 在研究中, 首尔地区的237名大学生回答了问卷. 研究对象被划分为两组: 一组(121名)回答关于计算机的问卷, 其他的116名回答关于牛仔裤的问卷. 搜集的数据通过AMOS 7来验证可信度, 效度以及变量间的相互关系. 验证性因子分析证明本研究的模型是可以用来进一步研究的. 品牌资产成分间的相互关系也通过AMOS 7 来验证. 结果模型的结果展现在图2中. 质量预期对于品牌的形象有积极的影响, 但是品牌意识却没有. 但是品牌意识, 质量预期, 以及品牌形象都对品牌忠诚度有积极的影响. 并且, 这些关系受到产品种类的调节. 本文的研究结果可以增进我们对于品牌资产成分间相互关系的了解, 并且可以支撑对于品牌资产的测量. 本文也对于产品种类的作用进行了阐述. 在现实的营销管理中, 这些结果可以提供一些建议来有效保持品牌资产.

지하 공동의 탐지와 모니터링을 위한 고정밀 중력탐사 (A Microgravity for Mapping and Monitoring the Subsurface Cavities)

  • 박영수;임형래;임무택;구성본
    • 지구물리와물리탐사
    • /
    • 제10권4호
    • /
    • pp.383-392
    • /
    • 2007
  • 지하 공동은 토지의 이용과 개발을 제한할 뿐 아니라 안전과 환경에 심각한 우려를 준다. 우리나라는 석회암이 널리 분포하고 폐광산이 많으며 도심이 확장되고 토지의 개발이 활발하여, 지하 공동에 의한 지반 안전과 환경 보존 문제를 안고 있다. 전남 무안군 덕보들에 한국지질자원연구원에서 마련한 물리탐사 실험장에서 지하 공동의 탐지와 모니터링을 위한 고정밀 중력탐사를 하였다. 중력은 약 30 m 간격의 논둑길을 따라 5 m 간격으로 모두 800여 측점에서 AutoGrav CG-3 중력계로 측정하였으며, 측점의 절대적 위치 오차는 수 mm 이하로 유지하였다. 중력 측선은 MS (minimum support) 역산으로 밀도 분포를 작성하였으며, 고분해능 3차원 중력 역해의 비유일성을 줄이기 위하여 Euler 디컨벌루션의 해를 제한 조건으로 이용하는 역산 방법을 고안하였다. 역산에 의하여 작성한 밀도 분포는 잔여 중력 분포와 전체적으로 잘 일치하였으며, 특히 공동과 관련된 것으로 예상되는 3곳의 중력 이상대의 밀도 분포 형태, 즉 공동의 위치 뿐 아니라 공동형태와 발달 양상을 잘 보여주었다. 이러한 해석 결과는 시추 주상도와 매우 잘 일치하였다. 탐사 실험장의 진입로에서 그라우팅을 전후하여 시간차 중력 모니터링을 하였다. 탐사 조건에 의한 불일치는 기준점의 관측 중력을 비교하여 조정하였다. MS 역산으로 작성한 그라우팅 전, 후의 밀도 분포를 비교하여 그라우팅의 효과를 검토하였다. 이 현장 사례를 통하여 ${\mu}Gal$ 수준의 정밀도와 정확도의 고정밀 중력탐사는 지하 공동을 탐지할 뿐 아니라 공동의 분포와 발달 양상을 확인하는 가장 직접적이고 효과적인 수단이 됨을 보여주었다. 또한, 시간차 중력 모니터링은, 여러 가지 오차 요인들이 있지만, 시간의 경과에 따른 지하 밀도 분포의 변화를 관측하는 데 효과적임을 보여주었다.

공간구문론을 이용한 도시 내 삵 이동통로 적지선정 (Site Selection of Wildlife Passage for Leopard Cat in Urban Area using Space Syntax)

  • 박종준;우동걸;오대현;박종화
    • 한국조경학회지
    • /
    • 제40권1호
    • /
    • pp.92-99
    • /
    • 2012
  • 도시 지역의 야생동물 서식처는 급격한 도시화와 산업화 과정에서 파괴되거나 파편화되었다. 도시지역에 서식하는 야생동물의 로드킬을 저감하기 위해 파편화된 서식처의 연결이 필요하다. 도시지역의 인공장애물을 안전하게 통과하기 위해서는 야생동물의 행동에 기반한 야생동물 이동통로의 위치가 선정되어야 한다. 본 연구에서는 강서습지생태공원에서 서식하는 멸종위기종인 삵을 목표종으로 하여 야생동물 이동통로의 잠재적 대상지를 파악하였다. 이동통로의 선정은 공간구조를 객관적으로 평가하는 방법인 공간구문론 분석을 통해 이루어졌다. 통합도가 높은 것이 공간의 접근성과 연결성 높은 것을 의미하며, 이 논문에서는 통합도가 높은 공간이 삵이 더 자주 이동하는 공간을 의미한다. 포획된 삵은 발신기를 부착하여 2009년 3월부터 6월까지 4개월간 월 72시간 연속으로 원격무선추적하였다. 삵의 이동경로를 분석하기 위해 ArcGIS의 Animal Movenent와 Hawth Tools를 이용하였고, 공간구문론 분석을 위해 Axwoman 4.0을 사용하였다. 삵의 하루 평균이동거리는 $2.099{\pm}1.08km$로 나타났다. 연구기간 동안 삵은 로드킬의 위험을 안고 올림픽대로를 20회 이상 횡단하였다. 삵의 이동경로에 대한 공간통합도로서 전체 통합도는 0.458~1.834, 국부 통합도는 0.210~6.061로 나타났다. 삵의 이동경로와 도로가 중첩되는 5개 지점을 선정하여 통합도 값을 측정하였으며, 이들 지점 중 통합도가 높은 곳이 로드킬의 발생 가능성이 높은 곳이다. 따라서 5개 지점 중 전체 통합도와 국부 통합도가 가장 높은 곳을 각각 잠재적 이동통로 적지로 제안하였다. 국부 통합도가 가장 높은 지점에 터널형 이동통로가 건설 중에 있으며, 공사 완료 후 이들 지점에 대한 이동통로의 적지 여부를 검증할 것이다.

학령기 아동의 CBCL 조절곤란프로파일(Child Behavior Checklist Dysregulation Profile)의 요인구조와 특성 (Characteristics of the Factor Structure of the Child Behavior Checklist Dysregulation Profile for School-aged Children)

  • 김은영;하은혜
    • 한국심리학회지:학교
    • /
    • 제17권1호
    • /
    • pp.17-38
    • /
    • 2020
  • 본 연구에서는 국내 학령기 아동을 대상으로 아동·청소년행동평가척도 조절곤란프로파일(Child Behavior Checklist Dysregulation Profile; CBCL-DP)의 요인구조를 조사하고, CBCL-DP특성을 보이는 집단(임상군)과 그렇지 않은 집단(정상군)간 부적응 및 문제행동 수준에 차이가 있는지 확인하고자 하였다. CBCL-DP의 가장 적합한 요인구조를 확인하기 위해 선행연구에서 제시한 3가지 경쟁모형에서 확인적 요인분석을 실시하였으며, 그 결과 단일요인모형(One-factor)과 2차요인모형(Second order)보다 Bifactor모형이 가장 좋은 적합도를 보였다. 가장 적합한 요인구조의 타당성을 확인하기 위해 관련 변인들과의 회귀경로를 계산한 결과 Bifactor모형에서 CBCL-DP는 부모가 보고한 집행기능곤란과 담임교사가 보고한 학교적응 및 강점난점의 모든 하위요인들과 관련되어 있었으며, 불안/우울, 공격행동, 주의집중문제의 3가지 요인들은 차별화된 연관성을 보였다. CBCL-DP의 특성을 나타내는 집단의 부적응 및 문제행동 수준을 CBCL-DP 특성을 보이지 않는 정상군과 비교한 결과, CBCL-DP 특성을 보이는 아동은 정상군 아동보다 집행기능 곤란 정도가 더 높았으며, 학교생활 적응을 잘 하지 못하고 바람직한 행동을 할 가능성이 낮은 것으로 나타났다. 결과적으로 CBCL-DP는 특정 증후군(AAA)보다 여러 가지 다양한 측면에서 부정적 결과와 관련이 있었으며, 선행연구들의 요인구조와 본 연구 표본이 부합하고 있다는 점은 광범위한 조절곤란 증후군으로 CBCL-DP를 개념화하는데 일관되고 통합적인 연구결과를 제시했음을 시사한다. 또한 CBCL-DP는 정서·행동문제가 결합된 고위험군 아동을 조기발견하고 중재함에 있어 학교 및 상담 장면에서 심층적이고 전문적인 진단도구로서 유용하게 사용될 수 있을 것으로 기대된다. 이러한 연구결과를 바탕으로 본 연구의 의의, 한계점 및 향후 연구 방향에 대해 논의하였다.

대형마트 충성도의 이중경로모형 (Dual Path Model in Store Loyalty of Discount Store)

  • 지성구;이인구
    • 한국유통학회지:유통연구
    • /
    • 제15권1호
    • /
    • pp.1-24
    • /
    • 2010
  • 국내 대형마트 점포 수는 2008년 기준 403개로 포화시점에 근접하고 있다. 이러한 경쟁상황에서 '점포충성도(store loyalty)'가 지속적 경쟁우위를 위한 전략적 도구로써 그 활용성이 점점 더 중요시 되고 있다. 다양한 관점에서 점포충성도를 대형마트 연구의 핵심적 과제 다루어왔으나, 통합적인 연구 접근 방법이 미흡한 실정이다. 따라서 본 연구에서는 통합적 관점에서 점포충성도가 형성되는 두 가지 경로를 제안하였다. 이중경로모형은 첫째, 내재적 경로 '서비스품질$\rightarrow$고객만족$\rightarrow$점포충성도', 둘째, 외재적 경로 '점포개성$\rightarrow$점포동일시$\rightarrow$점포 충성도'로 구성된다. 조사대상은 대형마트를 이용하는 소비자들을 대상으로 진행하였으며, 구조방정식모형 분석을 통하여 제안된 이중경로모형의 적합성 및 가설검증을 실시하였다. 연구결과, 모형의 적합지수들은 상당히 좋은 값들을 보여주고 있다. 또한 본 연구에서 새롭게 제시된 내재적 경로인 서비스품질은 고객만족에 정의 영향을 미치고, 고객만족은 결과변수인 대형마트의 점포충성도에 매우 유의하게 영향을 준 것으로 나타났다. 그리고 외재적 경로에서 대형마트의 점포개성은 점포동일시에 긍정적인 영향을 주고 매개변수인 점포개성은 점포충성도에 영향을 미치는 것으로 나타났다. 이를 통해 본 연구는 대형마트의 점포충성도 형성에 관한 두 가지 경로를 제시함으로써, 이론적, 관리적 시사점을 도출하였고 연구의 한계점과 미래연구방향을 제시하였다.

  • PDF

인터넷쇼핑 상황에서 보상프로그램이 브랜드충성도에 미치는 영향에 관한 연구 (Effects of Reward Programs on Brand Loyalty in Online Shopping Contexts)

  • 김지헌;강현모
    • Asia Marketing Journal
    • /
    • 제14권2호
    • /
    • pp.39-63
    • /
    • 2012
  • 보상프로그램에 관한 기존 연구들은 프로그램에 대한 소비자의 지각된 가치가 높을수록 브랜드충성도가 증가할 것이라는 가정 하에, 소비자가 가장 선호하는 보상프로그램을 설계하는 데 초점을 맞추어왔다. 또한 이들은 연구대상으로 인터넷쇼핑몰보다는 주로 오프라인 매장을 사용하였다. 이는 인터넷쇼핑 상황에서 보상프로그램에 대한 소비자의 가치인식이 브랜드충성도에 미치는 효과가 실제로 유의한지 그렇다면 어떠한 경로를 통해 영향을 미치는 지에 대한 연구가 미흡함을 의미한다. 한편, 소비자는 인터넷쇼핑몰을 이용할 때 필요한 물건을 구매하고자 하는 실용적 동기와 쇼핑 그 자체를 즐기고자 하는 쾌락적 동기를 가지게 되며, 인터넷쇼핑몰은 소비자들의 이러한 양면적 동기를 충족시킬 수 있는 가치(실용적 또는 쾌락적 가치)있는 경험들을 제공함으로써 브랜드충성도를 증가시킬 수 있다. 이는 인터넷쇼핑몰이 제공하는 보상의 유형이 실용적인지, 쾌락적 인지에 따라 다른 유형의 쇼핑 가치를 강화함으로써 브랜드충성도에 영향을 미치는 경로가 달라질 수 있음을 의미한다. 따라서 본 연구는 다음과 같은 세 가지 목적을 가지고 수행되었다. 첫째, 인터넷쇼핑 상황에서의 보상프로그램이 오프라인 쇼핑상황에서와 동일하게 브랜드충성도를 제고하는데 효과적인지 알아보고자 하였다. 둘째, 기존 연구에서 고려하지 않은 "보상프로그램 가치인식 → 브랜드신뢰, 브랜드감정 → 브랜드충성도" 경로를 추가한 연구모형을 제안하고 분석함으로써, 보상프로그램 가치인식이 브랜드충성도에 미치는 또 다른 경로가 있음을 보이고자 하였다. 마지막으로, 보상의 유형(실용적 vs. 쾌락적)에 따라 "보상프로그램 가치인식 → 브랜드신뢰, 브랜드감정 → 브랜드충성도" 관계가 조절될 수 있는지 확인하고자 하였다. 이를 위해 문헌연구를 통해 10개의 가설 및 연구모형을 도출하였으며, 20대 남녀220명을 대상으로 설문조사를 실시하여 데이터를 수집한 후, 구조방정식모델을 이용해 가설들을 검정함으로써 다음과 같은 시사점들을 제공하였다. 먼저, 본 연구는 오프라인 매장을 중심으로 연구되어온 브랜드충성도에 대한 보상프로그램의 효과가 인터넷쇼핑 상황에서도 유의함을 보여줌으로써 인터넷쇼핑몰이 보상프로그램을 운영해야 할 논리적 근거를 마련해주고 있다. 하지만 기존 연구를 통해 확인된 "보상프로그램 가치인식 → 프로그램 충성도 → 브랜드충성도"의 경로가 인터넷쇼핑 상황에서는 유의하지 않은 것으로 나타났다. 반면 "보상프로그램 가치인식 → 브랜드신뢰, 브랜드감정 → 브랜드충성도"의 경로가 유의하게 나타나 인터넷쇼핑몰이 제공하는 보상프로그램에 대한 가치인식은 오프라인 매장과는 다른 경로를 통해 브랜드충성도에 영향을 미치고 있음을 알 수 있다. 한편, 인터넷쇼핑몰이 제공하는 보상프로그램에 대한 가치인식이 브랜드 신뢰에 미치는 영향은 쾌락적 보상보다는 실용적 보상이 더 크게 나타난 반면, (통계적으로 유의하지는 않았지만) 보상프로그램에 대한 가치인식이 브랜드감정에 미치는 영향은 실용적 보상 보다는 쾌락적 보상이 더 큰 것으로 나타났다. 이는 해당 인터넷쇼핑몰을 이용할 때 소비자가 상대적으로 더 추구하는 가치의 유형(실용적 vs. 쾌락적)을 파악하여 이를 강화할 수 있는 유형의 보상을 제공하거나 소비자가 스스로 보상의 유형을 선택할 수 있는 권한을 부여할 경우, 브랜드신뢰와 브랜드감정을 효과적으로 증가시켜 브랜드충성도를 제고할 수 있음을 말해준다.

  • PDF

온.오프라인 채널에서 지각된 품질이 서비스의 개인가치에 미치는 영향에 관한 연구 -인지욕구의 조정효과를 중심으로- (A Study on Perceived Quality affecting the Service Personal Value in the On-off line Channel - Focusing on the moderate effect of the need for cognition -)

  • 성형석
    • 한국유통학회지:유통연구
    • /
    • 제15권3호
    • /
    • pp.111-137
    • /
    • 2010
  • 본 연구는 서비스 시장에서의 지각된 품질과 개인가치간의 인과적 관계 및 고객의 인지욕구에 따른 온 오프라인상의 조절효과에 대해 실증분석하였으며 이를 통해 개인가치에 대한 서비스 전략과 마케팅 관리의 중요성을 제시하고 있다. 서비스 시장에서 서비스 제공자와 구매자간의 장기적 거래관계의 중요성이 크게 부각됨에 따라 관계구축 및 강화에 매우 중요한 역할을 하는 개인가치에 관한 연구는 학계뿐만 아니라 실무적으로도 고객관계관리의 관점에서 시사하는 바가 크다고 할 수 있다. 실증분석을 위해 대형마트(할인점)와 인터넷 쇼핑몰을 이용하는 고객을 대상으로 설문을 통해 데이터를 수집하였으며 온 오프라인의 비교분석을 통한 차이검증을 위한 인과적 구성모델에 대해 구조방정식 모델분석을 통해 가설검증하였다. 구성모델에 대한 분석결과 물리적 환경, 상호작용 품질, 그리고 결과품질로 구성된 지각된 품질은 안정적 삶, 사회적 인식, 사회적 통합으로 구성된 서비스 개인가치에 통계적으로 매우 유의한 정(+)의 영향을 미치는 것으로 나타났으며 집단간 차이효과분석을 통해서도 온 오프라인에 따른 조정효과는 온라인에서보다는 오프라인에서 더 유의한 것으로 나타났다. 그리고 온라인상에서의 서비스에 대한 인지욕구가 높을 때보다는 오프라인상에서의 서비스에 대한 인지욕구가 높을 때 개인가치에 더 유의한 영향을 미치는 것으로 나타났다. 마지막으로 본 연구의 구성모델에 대한 적합도 역시 수용할만한 수준인 것으로 나타났다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF