• Title/Summary/Keyword: Tomotherapy

Search Result 109, Processing Time 0.035 seconds

The Usability Analysis of 3D-CRT, IMRT, Tomotherpy Radiation Therapy on Nasopharyngeal Cancer (NPC의 방사선치료시 3D-CRT, IMRT, Tomotherapy의 유용성 분석)

  • Song, Jong-Nam;Kim, Young-Jae;Hong, Seung-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.365-371
    • /
    • 2012
  • The radiation therapy treatment technique is developed from 3D-CRT, IMRT to Tomotherapy. and these three technique was most widely using methods. We find out a comparison normal tissue doses and tumor dose of 3D-CRT, IMRT(Linac Based), and Tomotherapy on Head and Neck Cancer. We achieved radiological image used the Human model phantom (Anthropomorphic Phantom) and it was taken CT simulation (Slice Thickness : 3mm) and GTV was nasopharngeal region and PTV(including set-up margin) was GTV plus 2mm area. and transfer those images to the radiation planning system (3D-CRT - ADAC-Pinnacle3, Tomotherapy - Tomotherapy Hi-Art System). The prescription dose was 7020 cGy and measuring PTV's dose and nomal tissue (parotid gland, oral cavity, spinal cord). The PTV's doses was Tomotherapy, Linac Based - IMRT, 3D-CRT was 6923 cGy, 6901 cGy and 6718 cGy its dose value was meet TCP because its value was up to the 95% based on 7020 cGy, Nomal tissue (parotid gland, oral cavity, spinal cord) was 1966 cGy(Tomotherapy), 2405 cGy(IMRT), 2468 cGy(3D-CRT)[parotid gland], 2991 cGy(Tomotherapy), 3062 cGy(IMRT), 3684 cGy (3D-CRT)[oral cavity], 1768 cGy(Tomotherapy), 2151 cGy(IMRT), 4031 cGy(3D-CRT)[spinal cord] its value did not exceeded NTCP. All the treatment techniques are equated with tumor and nomal tissue doses. The 3D-CRT was worse than other techniques on dose distribution, but it is reasonable in terms of TCP and NTCP baseline Tomotherapy, IMRT -dose distribution was relatively superior- was hard to therapy to claustrophobic patients and patients with respiratory failure. Particularly, in case on Tomotherapy, it take MVCT before treatment so dose measurement will be unnecessary radiation exposure to patients. Conclusion, Tomotherapy was the best treatment technique and 2nd was IMRT, and 3rd 3D-CRT. But applicable differently depending on the the patient's condition even though dose not matter.

Dose Distribution Comparison between Arc Radiation Therapy and Tomotherapy (아크치료기법과 토모테라피치료의 선량분포 비교)

  • Kim, Ji-Yoon;Lee, Seung-Chul;Cheon, Geum-Seong;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.723-730
    • /
    • 2021
  • This study tries to compare dose distribution between arc radiation therapy and Tomotherapy, which are main radiation therapy modalities. The subjects of this study are lung cancer patients. For planning target volume (PTV), a dose of 60.0 Gy was set as a basis. The PTVmean of Arc was 61.04 Gy, and that of Tomotherapy was 58.50 Gy. The total lung capacities of Arc and Tomotherapy were 3.0 Gy and 4.24 Gy, respectively. The mean heart doses of Arc and Tomotherapy were 0.13 and 0.34, respectively; the mean trachea dose of Arc and Tomotherapy were 1.35 and 2.58, respectively; the mean esophagus dose of Arc and Tomotherapy were 0.41 and 0.86, respectively; the mean spinal cord dose of Arc and Tomotherapy were 3.65 and 4.68, respectively. With regard to the appropriateness of therapeutic effect in DHV, both modalities seemed appropriate. Tomotherapy protected normal tissues better than Arc radiation therapy. In Tomotherapy, patients need to have treatment long in a limited space. If such a point is overcome, Tomotherapy is better. Otherwise, Arc radiation therapy can be applied. This study was conducted with treatment planning images. Therefore, the results of this study are different from actual treatment results. If more research is conducted to overcome the limitation, the effects of radiation therapy are expected to increase further.

Fetal dose from Head and Neck Tomotherapy Versus 3D Conformal Radiotherapy

  • Park, So Hyun;Choi, Won Hoon;Choi, Jinhyun
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.4
    • /
    • pp.156-160
    • /
    • 2019
  • Background: To compare the dose of radiation received by the fetus in a pregnant patient irradiated for head and neck cancer using helical tomotherapy and three-dimensional conformal radiation therapy (3DCRT). Materials and Methods: The patient was modeled with a humanoid phantom to mimic a gestation of 26 weeks. Radiotherapy with a total dose of 2 Gy was delivered with both tomotherapy (2.5 and 5.0 cm jaw size) and 3DCRT. The position of the fetus was predicted to be 45 cm from the field edge at the time of treatment. The delivered dose was measured according to the distance from the field edge and the fetus. Results and Discussion: The accumulated dose to the fetus was 1.6 cGy by 3DCRT and 2 and 2.3 cGy by the 2.5 and 5 cm jaw tomotherapy plans. For tomotherapy, the fetal dose with the 2.5 cm jaw was lower than that with the 5 cm jaw, although the radiation leakage was greater for 2.5 cm jaw plan due to the 1.5 fold longer beam-on time. At the uterine fundus, tomotherapy with a 5 cm jaw delivered the highest dose of 2.4 cGy. When the fetus moves up to 35 cm at the 29th week of gestation, the resultant fetal doses for 3DCRT and tomotherapy with 2.5 and 5 cm jaws were estimated as 2.1, 2.7, and 3.9 cGy, respectively. Conclusion: For tomotherapy, scattering radiation was more important due to the high monitor unit values. Therefore, selecting a smaller jaw size for tomotherapy may reduce the fetal dose. however, evaluation of risk should be individually performed for each patient.

Comparison of Dose Distribution between the Techniques of Non-small Cell Lung Cancer (비소세포폐암의 방사선 치료기법간의 선량분포의 비교)

  • Lee, Seung-chul;Kim, Young-jae;Jang, Seongjoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.233-239
    • /
    • 2016
  • Comparison of the dose aspect that radiation therapy treatments using IMRT, tomotherapy, mArc (modulated arc therapy). The experimental subject is non-small cell lung cancer patient. The prescription dose is 58.0 Gy to the volume of PTV(planning target volume). and spinal cord, esophagus, and liver organ is the normal organ(OAR, organ at risk). Average PTV value is 57.60 Gy in mArc and 61.04 Gy in tomotherapy and 58.95 Gy in IMRT. The average dose of the Esophagus is 2.84 Gy in m-Arc, 5.14 Gy in tomotherapy, 1.84 Gy in IMRT. The average dose of the Liver is 19.44 Gy in m-Arc, 12.22 Gy in tomotherapy, 21.97 Gy in IMRT. The average dose of the Spinal cord is 5.72 Gy in m-Arc, 7.08 Gy in tomotherapy, 6.15 Gy in IMRT. Results of this study is no significant difference between mArc and tomotherapy and Linac based IMRT in dose study and also, mArc's dose coverage and dose volume histogram is better than IMRT and tomotherapy. but, This study is limited to a disease of cancer. in addition, fewer number of groups. The wide range the more research can be developed patient-specific treatment techniques and be applied to the patients

Development of Tomotherapy couch device capable of yaw-directional correction (Yaw방향의 보정이 가능한 Tomotherapy couch device의 개발)

  • Chae, Moon Ki;Kwon, Dong Yeol;Sun, Jong Lyool;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.139-151
    • /
    • 2018
  • Objectives : A self-made "Tomotherapy couch device" capable of correcting the Yaw direction was fabricated and evaluated for its usefulness. Materials and Methods : "Tomotherapy couch device" capable of correcting the Yaw direction is made of rigid fibreboard with a flexural strength of $200kg/cm^2$. CBCT Image from Novalis Tx and Iso-Align Phantom from MED-TEC were used to evaluate the physical accuracy. The treatment plan was designed using Accuray $Precision^{TM}$ and In House Head and Phantom. Accuray $PrecisionART^{TM}$ and $Precision^{TM}$ was used to evaluate dose. Results : Evaluation results, the self-fabricated device accurately corrected the setup error, Target dose was within 95 %~107 % of all. In order to directly evaluate the OAR dose according to the Yaw change, the absolute dose was measured. As a result, when the error in the Yaw direction was $3^{\circ}$, the specific OAR showed a maximum difference of 18.4 %. Conclusion : "Tomotherapy couch device" capable of correcting the Yaw direction can be manufactured at a lower cost compared to the effect, and it can prevent the patient's MVCT image dose for re-imaging. Accurate radiation therapy without errors can be performed.

  • PDF

Dosimetric evaluation of Tomotherapy and four-box field conformal radiotherapy in locally advanced rectal cancer

  • Yu, Mina;Jang, Hong Seok;Jeon, Dong Min;Cheon, Geum Seong;Lee, Hyo Chun;Chung, Mi Joo;Kim, Sung Hwan;Lee, Jong Hoon
    • Radiation Oncology Journal
    • /
    • v.31 no.4
    • /
    • pp.252-259
    • /
    • 2013
  • Purpose: To report the results of dosimetric comparison between intensity-modulated radiotherapy (IMRT) using Tomotherapy and four-box field conformal radiotherapy (CRT) for pelvic irradiation of locally advanced rectal cancer. Materials and Methods: Twelve patients with locally advanced rectal cancer who received a short course preoperative chemoradiotherapy (25 Gy in 5 fractions) on the pelvis using Tomotherapy, between July 2010 and December 2010, were selected. Using their simulation computed tomography scans, Tomotherapy and four-box field CRT plans with the same dose schedule were evaluated, and dosimetric parameters of the two plans were compared. For the comparison of target coverage, we analyzed the mean dose, $V_{nGy}$, $D_{min}$, $D_{max}$, radical dose homogeneity index (rDHI), and radiation conformity index (RCI). For the comparison of organs at risk (OAR), we analyzed the mean dose. Results: Tomotherapy showed a significantly higher mean target dose than four-box field CRT (p = 0.001). But, $V_{26.25Gy}$ and $V_{27.5Gy}$ were not significantly different between the two modalities. Tomotherapy showed higher $D_{max}$ and lower $D_{min}$. The Tomotherapy plan had a lower rDHI than four-box field CRT (p = 0.000). Tomotherapy showed better RCI than four-box field CRT (p = 0.007). For OAR, the mean irradiated dose was significantly lower in Tomotherapy than four-box field CRT. Conclusion: In locally advanced rectal cancer, Tomotherapy delivers a higher conformal radiation dose to the target and reduces the irradiated dose to OAR than four-box field CRT.

Comparison of survival rates between patients treated with conventional radiotherapy and helical tomotherapy for head and neck cancer

  • Kong, Moonkyoo;Hong, Seong Eon;Choi, Jinhyun;Kim, Youngkyong
    • Radiation Oncology Journal
    • /
    • v.31 no.1
    • /
    • pp.1-11
    • /
    • 2013
  • Purpose: Compared to conventional radiotherapy (RT), intensity-modulated radiotherapy (IMRT) significantly reduces the rate of treatment-induced late toxicities in head and neck cancer. However, a clear survival benefit of IMRT over conventional RT has not yet been shown. This study is among the first comparative study to compare the survival rates between conventional RT and helical tomotherapy in head and neck cancer. Materials and Methods: From January 2008 to November 2011, 37 patients received conventional RT and 30 patients received helical tomotherapy for management of head and neck cancer. We retrospectively compared the survival rates between patients treated with conventional RT and helical tomotherapy, and analyzed the prognostic factors for survival. Results: The 1- and 2-year locoregional recurrence-free survival rates were 61.2% and 58.1% for the conventional RT group, 89.3% and 80.3% for the helical tomotherapy group, respectively. The locoregional recurrence-free survival rates of the helical tomotherapy group were significantly higher than conventional RT group (p = 0.029). There were no significant differences in the overall and distant metastasis-free survival between the two groups. RT technique, tumor stage, and RT duration were significant prognostic factors for locoregional recurrence-free survival. Conclusion: This study showed the locoregional recurrence-free survival benefits of helical tomotherapy in the treatment of head and neck cancers.

Clinical Outcome of Helical Tomotherapy for Inoperable Non-Small Cell Lung Cancer: The Kyung Hee University Medical Center Experience

  • Kong, Moonkyoo;Hong, Seong Eon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.4
    • /
    • pp.1545-1549
    • /
    • 2014
  • Background: Published studies on clinical outcome of helical tomotherapy for lung cancer are limited. The purpose of this study was to evaluate clinical outcomes and treatment-related toxicity in inoperable non-small cell lung cancer (NSCLC) patients treated with helical tomotherapy in Korea. Materials and Methods: Twenty-seven patients with NSCLC were included in this retrospective study. Radiotherapy was performed using helical tomotherapy with a daily dose of 2.1-3 Gy delivered at 5 fractions per week resulting in a total dose of 62.5-69.3 Gy. We assessed radiation-related lung and esophageal toxicity, and analyzed overall survival, locoregional recurrence-free survival, distant metastasis-free survival, and prognostic factors for overall survival. Results: The median follow-up period was 28.9 months (range, 10.1-69.4). The median overall survival time was 28.9 months, and 1-, 2-, and 3-year overall survival rates were 96.2%, 92.0%, and 60.0%. The median locoregional recurrence-free survival time was 24.3 months, and 1-, 2-, and 3-year locoregional recurrence-free survival rates were 85.2%, 64.5%, and 50.3%. The median distant metastasis-free survival time was 26.7 months, and 1-, 2-, and 3-year distant metastasis-free survival rates were 92.3%, 83.9%, and 65.3%, respectively. Gross tumor volume was the most significant prognostic factor for overall survival. No grade 4 or more toxicity was observed. Conclusions: Helical tomotherapy in patients with inoperable NSCLC resulted in high survival rates with an acceptable level of toxicity, suggesting it is an effective treatment option in patients with medically inoperable NSCLC.

Usefulness Evaluation on the Treatment Plan of Tomotherapy and VMAT in Radiotherapy for Prostate Cancer (전립선암의 방사선치료에서 토모테라피와 VMAT의 치료계획에 따른 유용성 평가)

  • Heo, Kwangmyoung;Han, Jaebok;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.449-457
    • /
    • 2015
  • In this study, to evaluate the usefulness of the treatment plan of tomotherapy and volumetric modulated arc therapy (VMAT) in the radiotherapy for prostate cancer, the absorbed dose, dose volume histogram (DVH), treatment efficiency, and the results of dose verification accuracy using MapCHECK2 were compared and analyzed. Of the prostate cancer patients who underwent tomotherapy treatment in the Radiologic Oncology of H University Hospital between July 2014 and December 2014, 12 patients were randomly selected. As a result of analyzing the absorbed dose and DVH, both radiologic treatment plans showed slight differences in the treatment of the cancer tissues and the bladder, but the difference was in the error range of -5% to +3%, and did not exceed the side effect guideline or the tolerance dose limit. VMAT showed higher treatment efficiency than tomotherapy with a 2.5 times shorter treatment time and a 10.3 times less monitor unit (MU). Both showed 95% or higher dose accuracy satisfying the standard. VMAT showed 2.3% higher efficiency than tomotherapy. In both tomotherapy and VMAT, appropriate doses were absorbed for cancer tissues, and did not exceed the tolerance dose for normal tissues showing no significant difference in dose distribution. However, considering the shorter treatment time, lower total MU, and better treatment efficiency and dose verification accuracy, VMAT may be more useful than tomotherapy in cancer treatments.