• 제목/요약/키워드: Tomography, emission computed

검색결과 379건 처리시간 0.021초

전이암으로 오인된 다원성(multifocal) 결핵 1예 (A Case of Multifocal Tuberculosis Mimicking Metastatic Malignancy)

  • 조인정;임소연;천은미;류연주;이진화;심윤수;장중현;심성신;배정호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제63권2호
    • /
    • pp.173-177
    • /
    • 2007
  • 저자들은 FDG-PET과 전산화 단층 촬영에서 인두, 복부, 흉부에 악성 종양이 의심되는 소견이 보여 점막 표피모양 암종으로 오인된 복강내 결핵, 인두 결핵, 기관지 결핵이 동반된 환자를 조직 검사를 통하여 결핵으로 진단하였고, 이 환자에게 항 결핵제 투여의 치료를 통하여 추적 전산화 단층 촬영에서 호전 경과를 보인 1예를 경험하였기에 이를 보고하는 바이다.

A Numerical Study of Different Types of Collimators for a High-Resolution Preclinical CdTe Pixelated Semiconductor SPECT System

  • Jeong, Hyun-Woo;Kim, Jong Seok;Bae, Se Young;Seo, Kanghyen;Kim, Seung Hun;Kang, Seong Hyeon;Shin, Dong Jin;Lee, Chang-Lae;Kim, Kyuseok;Lee, Youngjin
    • Journal of the Optical Society of Korea
    • /
    • 제20권6호
    • /
    • pp.663-668
    • /
    • 2016
  • In single-photon-emission computed tomography (SPECT) with a pixelated semiconductor detector (PSD), not only pinhole collimators but also parallel-hole collimators are often used in preclinical nuclear-medicine imaging systems. The purpose of this study was to evaluate and compare pinhole and parallel-hole collimators in a PSD. For that purpose, we paired a PID 350 (Ajat Oy Ltd., Finland) CdTe PSD with each of the four collimators most frequently used in preclinical nuclear medicine: (1) a pinhole collimator, and (2) low-energy high-resolution (LEHR), (3) low-energy general-purpose (LEGP), and (4) low-energy high-sensitivity (LEHS) parallel-hole collimators. The sensitivity and spatial resolution of each collimator was evaluated using a point source and a hot-rod phantom. The highest sensitivity was achieved using LEHS, followed by LEGP, LEHR, and pinhole. Also, at a source-to-collimator distance of 2 cm, the spatial resolution was 1.63, 2.05, 2.79, and 3.45 mm using pinhole, LEHR, LEGP, and LEHS, respectively. The reconstructed hot-rod phantom images showed that the pinhole collimator and the LEHR parallel-hole collimator give a fine spatial resolution for preclinical SPECT with PSD. In conclusion, we successfully compared different types of collimators for a preclinical pixelated semiconductor SPECT system.

Biodistribution of 99mTc Tricarbonyl Glycine Oligomers

  • Jang, Beom-Su;Lee, Joo-Sang;Rho, Jong Kook;Park, Sang Hyun
    • Toxicological Research
    • /
    • 제28권4호
    • /
    • pp.235-240
    • /
    • 2012
  • $^{99m}Tc$ tricarbonyl glycine monomers, trimers, and pentamers were synthesized and evaluated for their radiolabeling and in vivo distribution characteristics. We synthesized a $^{99m}Tc$-tricarbonyl precursor with a low oxidation state (I). $^{99m}Tc(CO)_3(H_2O)_3^+$ was then made to react with monomeric and oligomeric glycine for the development of bifunctional chelating sequences for biomolecules. Labeling yields of $^{99m}Tc$-tricarbonyl glycine monomers and oligomers were checked by high-performance liquid chromatography. The labeling yields of $^{99m}Tc$-tricarbonyl glycine and glycine oligomers were more than 95%. We evaluated the characteristics of $^{99m}Tc$-tricarbonyl glycine oligomers by carrying out a lipophilicity test and an imaging study. The octanol-water partition coefficient of $^{99m}Tc$ tricarbonyl glycine oligomers indicated hydrophilic properties. Single-photon emission computed tomography imaging of $^{99m}Tc$-tricarbonyl glycine oligomers showed rapid renal excretion through the kidneys with a low uptake in the liver, especially of $^{99m}Tc$ tricarbonyl triglycine. Furthermore, we verified that the addition of triglycine to prototype biomolecules (AGRGDS and RRPYIL) results in the improvement of radiolabeling yield. From these results, we conclude that triglycine has good characteristics for use as a bifunctional chelating sequence for a $^{99m}Tc$-tricarbonyl-based biomolecular imaging probe.

Encephalo-duro-arterio-synangiosis(EDAS) using Occipital Artery in Children with Moyamoya Disease

  • Choi, In-Jae;Hong, Seok-Ho;Cho, Byung-Kyu;Wang, Kyu-Chang;Kim, Seung-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권6호
    • /
    • pp.413-418
    • /
    • 2005
  • Objective : Although an encephaloduroarteriosynangiosis procedure using the superficial temporal artery [STA-EDAS] is an effective indirect bypass method in children with moyamoya disease[MMD], there is still a need for an additional bypass operation that can cover the area of the posterior circulation. The goal of this study is to evaluate the efficacy of the EDAS procedure using the occipital arteries [OA-EDAS]. Methods : From August 2003 to April 2004, We performed OA-EDAS in sixteen patients with MMD who have a circulatory insufficiency in the territory of the posterior cerebral artery[PCA]. The medical records were reviewed retrospectively. The surgical outcomes, including the changes in neurological status and imaging studies, with the degree of neovascularization on the cerebral angiogram, and the hemodynamic changes on single-photon emission computed tomography[SPECT], were analyzed. Results : These 16 children consisted of 5 boys and 11 girls aged 2 to 9 years. The clinical outcome of their PCA symptoms, such as visual transient ischemic attacks[TIAs] or visual field defect, was favorable in 14 patients of 16. Nine patients of 11 who underwent follow up magnetic resonance imaging[MRI] showed favorable MRI changes. On angiogram most of the patients exhibited good or fair revascularization of the PCA territory [7 of 8]. The hemodynamic changes on SPECT in the PCA territory after surgery showed improved vascular reserve in 13 of the 16 territories. Conclusion : OA-EDAS is a safe and efficacious revascularization procedure in patients with MMD who have compromised cerebral perfusion in PCA territory, or with visual TIAs.

산업용 SPECT의 검출기 개수가 영상 해상도에 미치는 영향 평가 (Effect of the Number of Detectors on Performance of Industrial SPECT)

  • 박장근;김찬형;김종범;문진호;정성희
    • 방사선산업학회지
    • /
    • 제5권4호
    • /
    • pp.325-330
    • /
    • 2011
  • To predict the details of flow in industrial process unit, single photon emission computed tomography (SPECT) is a promising technique. Recently, industrial SPECT based on medical system has developed by researchers of the Korea Atomic Energy Research Institute (KAERI) and Hanyang University. In the present study, to confirm the effect of the number of detectors on image quality, and determine the optimal number of detectors in industrial SPECT, industrial SPECT system with various geometries were evaluated by the Monte Carlo simulation. CsI(Tl) detectors ($12mm{\times}12mm{\times}20mm$) with collimators (the geometric resolution of collimator $R_g$ was 4 cm at the center of the 30 cm diameter cylindrical vessel object) were modeled in a hexagonal array, and the point sources of $^{99m}Tc$, $^{68}Ga$, and $^{137}Cs$ were simulated at the center of the cylindrical vessel object using the MCNPX code. Then, the reconstruction images of each geometry were reconstructed using the expectation maximization (EM) algorithm. In this study, the reciprocity theorem was used to improve computation time required for system matrix of the EM algorithm. The result shows that the resolution of the reconstructed image was significantly improved by increasing the number of detectors in industrial SPECT system and more than 60 detectors will be required for the resolution of the reconstructed image.

A Study on Comparison of Cardiac Ejection Fraction Values Measured in Myocardium SPECT and Cine MRI

  • Han, Jung-Seok;Dong, Kyung-Rae;Park, Yong-Soon;Chung, Woon-Kwan;Cho, Jae-Hwan;Cho, Young-Kuk
    • Journal of Magnetics
    • /
    • 제17권3호
    • /
    • pp.229-232
    • /
    • 2012
  • This study examined the correlation between MR cine and myocardium Single-photon emission computed tomography (SPECT) by comparing the measured cardiac ejection fractions. The usefulness of cardiac MRI was also evaluated. Ten patients (8 men, 2 women and average age of 58.6 years), who underwent a myocardium SPECT scan and cardiac cine MRI scan among patients who visited the hospital for the chief complaint of cardiac disorder from June 1, 2010 to February 10, 2011, were enrolled in this study. The cardiac ejection fraction was calculated from the images obtained in both scans. The data was used to examine the correlation. The regression equation the cardiac ejection fraction values of the 10 patients obtained in myocardium SPECT and MRI cine was Y = 1.12X-8.91 ($R^2$ = 0.78, significance of F = 0.001639, and confidence level of 95%). The results were significant when the cardiac ejection fraction obtained from MRI cine was compared with that obtained from myocardium SPECT. Overall, a cardiac examination using MRI enables an investigation of not only the ejection fraction but also the ED and ES volumes, stroke volume, wall thickness, and wall thickening in a higher spatial resolution despite the examination being conducted once. This examination is believed to be very useful for diagnosing patients with cardiac disease.

Polydopamine-mediated surface modifications of poly ʟ-lactic acid with hydroxyapatite, heparin and bone morphogenetic protein-2 and their effects on osseointegration

  • Yun, Young Jin;Kim, Han-Jun;Lee, Deok-Won;Um, Sewook;Chun, Heung Jae
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제67권
    • /
    • pp.244-254
    • /
    • 2018
  • Surface modified poly ${\text\tiny{L}}$-lactic acid (PLLA) samples with hydroxyapatite (HA), heparin and bone morphogenetic protein-2 (BMP-2) mediated by polydopamine (pDA) coating (PLLA/pDA/HA/Hep/BMP-2) were prepared, and their effects on the enhancements of bone formation and osseointegration were evaluated in vitro and in vivo as compared to PLLA, PLLA/pDA/HA, and PLLA/pDA/Hep/BMP-2. The changes in surface chemical compositions, morphologies and wettabilities were observed by X-ray photoelectron spectroscopy (XPS), field-emission scanning electron microscopy (FE-SEM), atomic force microscopy (AFM) and water contact angle measurements. Pre-coating of HA particles with pDA provided uniform and homogeneous anchoring of particles to PLLA surface. In addition, the strong ionic interaction between heparin and pDA led PLLA surface readily heparinized for loading of BMP-2. In vitro experiments revealed that the levels of alkaline phosphatase (ALP) activity, calcium deposition, and osteocalcin (OCN) gene expression were higher in MG-63 human osteosarcoma cell lines grown on PLLA/pDA/HA/Hep/BMP-2 than on control PLLA, PLLA/pDA/HA, and PLLA/pDA/Hep/BMP-2. In vivo studies using micro-computed tomography (micro-CT) also showed that PLLA/pDA/HA/Hep/BMP-2 screw exhibited greatest value of bone volume (BV) and bone volume/tissue volume (BV/TV) among samples. Histological evaluations with H&E and Von Kossa staining demonstrated that a combination of HA and BMP-2 contributed to the strong osseointegration.

PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가 (The Evaluation of the Difference of the SUV Caused by DFOV Change in PET/CT)

  • 곽인석;이혁;최성욱;석재동
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.13-20
    • /
    • 2011
  • PET/CT 검사에서 제한적인 CT (Computed Tomography)의 FOV (Field of View)는 PET 영상의 DFOV (Display FOV) 바깥부위에서 영상 잘림 현상 (truncation artifact)에 의한 오류를 유발할 수 있다. 본 논문에서는 영상 재구성 시 확대된 DFOV를 적용함에 따라 PET영상에서 표준섭취계수 (Standardization Uptake Value, SUV)의 차이를 측정하여 영상에 미치는 정도를 비교 평가하고 그 유용성을 알아보고자 하였다. 5.3 kBq/mL의 $^{18}F$(FDG)를 주입한 NEMA 1994 PET 모형을 FOV의 중앙에 위치하고 영상을 획득하고, 동일모형을 FOV의 바깥부분으로 위치를 변경하여 truncation 현상이 발생하도록 한 뒤 같은 방법을 적용하여 영상을 획득하였다. 각 실험을 통해 얻어진 데이터는 동일한 방법을 적용하여 영상을 재구성 하였으며, DFOV는 50 cm와 70 cm로 변경하여 각각 적용하였다. 그리고 방출영상에 관심영역을 설정하고 최대섭취계수($_{max}SUV$)를 비교 하였으며 육안적인 이상유무도 함께 확인하였다. 임상영상은 모형실험에서와 같이 truncation 현상이 발생한 환자군을 선정한 후 해당 환자의 방출영상에서 간(Liver) 부위에 관심영역을 설정하고 모형실험에서와 같이 영상 재구성 시 DFOV 변화에 따른 표준섭취계수의 차이를 비교 하였다. 모형을 FOV 내 중심에 위치시키고 시행한 실험에서 DFOV 증가에 따라 화소의 크기는 3.91 mm에서 5.47 mm로 증가하였고, 관심영역의 $_{max}SUV$는 각각 1.49에서 1.35로 나타나 확대된 DFOV 적용시 9.39%의 감소를 보였다. 모형을 FOV의 바깥부분으로 이동시킨 후 얻은 영상의 경우 $_{max}SUV$가 1.30에서 1.20로 7.69% 감소하였다. DFOV 확대로 인하여 추가적으로 나타난 부위에서의 $_{max}SUV$는 1.51이었고, truncation 현상이 발생한 부위를 기준으로 안쪽과 바깥쪽 부위의 $_{max}SUV$차이는 25.9%로 바깥쪽에서 높은 결과를 보였다. 임상영상의 확대된 DFOV를 적용한 경우 $_{max}SUV$ 3.38에서 3.13으로 7.39% 감소하였다. 확대된 DFOV를 적용할 경우에서의 $_{max}SUV$ 감소 현상은 화소 크기의 증가로 인해 화소 간 잡음 (Pixel to Pixel Noise)이 낮아져 발생하는 저평가 정도의 범위를 벗어나지 않았으며 확대된 부위의 영상에서 육안적 확인 시 선형인공산물 등의 이상이 발견되지 않아 truncation 현상 없는 영상을 얻을 수 있다는 점에서는 임상적 적용이 유용하다고 할 수 있다. 그러나 실제 환자에게 확대된 DFOV를 적용할 경우에는 영상면 전체에서 정량적 결과가 저평가 되는 것을 감안하여야 하며, 특히 확대되어 추가로 나타난 부위에서의 정량적 결과가 높게 나타날 수 있다는 점에 유의하여 적용해야 할 것이다.

  • PDF

감마카메라 영상에서 분해능 향상을 위한 Xact-bone의 유용성 평가 (Usefulness of Xact-bone for the Resolution Advancement of Gamma Camera Image)

  • 김종필;윤석환;임정진;우재룡
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.30-35
    • /
    • 2011
  • 현재 분해능 향상을 위한 프로그램인 Wide beam reconstruction (WBR: UltraSPECT, Israel) 을 사용하고 있다. WBR에 속해있는 Xact-Bone은 Planar영상과 Single photon emission computed tomography (SPECT) 영상의 분해능과 대조도를 향상시켜 상당한 영상의 질 향상에 도움을 준다고 보고 되어있다. 본 연구는 Xact-Bone의 임상적용에 대한 유용성을 알아보고자 한다. Xact-Bone에서의 유용성 평가는 분해능 평가와 Contrast Ratio를 비교분석하였다. Planar영상에서의 분해능 평가는 capillary tube를 이용하여 Full width at half maximum (FWHM)을 구하였고, Contrast Ratio분석은 2010년 1월부터 2010년 10월까지 bone scan 검사를 위해 본원에 내원한 50명의 환자 Xact-Bone의 사용 전 후 영상에서 Bone and Soft tissue (B/S) ratio 값을 비교 평가하였다. SPECT영상에서의 분해능 평가는 Triple Line Source Phantom을 이용하여 FWHM을 구하였고, Contrast Ratio 비교 분석은 NEMA IEC Body Phantom과 Standard Jaszczak Phantom을 이용하여 획득한 영상을 각각 Filtered backprojection (FBP), Orderd subset expectation maximization (OSEM), Xact-Bone으로 재구성하여 비교하였다. Planar영상에서의 유용성 평가는 capillary tube를 이용한 실험결과, FWHM은 기존의 Planar영상보다 WBR의 Xact-Bone 프로그램을 이용한 재구성 영상에서 약 20% 향상되었으며, B/S ratio값도 약 15% 향상되었다. SPECT영상의 유용성 평가는 Triple line Source Phantom을 이용한 실험결과, FWHM은 Xact-Bone이 FBP, OSEM 기법보다 각각 20%, 10% 향상되었다. 또한 NEMA IEC body Phantom을 이용한 Contrast Ratio 비교분석결과 각각 20%, 10% 향상되었고, Standard Jaszczak Phantom을 이용한 Contrast Ratio 비교분석 결과는 각각 90%, 50% 향상되었다. WBR의 Xact-bone 프로그램을 이용한 Planar 영상에서는 사용하지 않은 경우와 비교하였을 경우 상당한 영상의 분해능과 Contrast Ratio가 향상됨을 알 수 있었고, SPECT영상에서 기존의 FBP, OSEM 영상재구성 방법보다 분해능, Contrast Ratio가 향상됨을 알 수 있었다. 이에 WBR의 Xact-Bone을 이용함으로써 영상의 질적 향상이 기대되는 바이다. 하지만, 새로운 소프트웨어 도입시 병원의 특성에 맞는 protocol 과 임상적용이 필요하다고 사료된다.

  • PDF

Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교 (Comparison of Attenuation Correction Methods for Brain SPECT Ima)

  • 조진우;김창호;나수경;이귀원
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.120-125
    • /
    • 2012
  • 이 연구의 목적은 Brain SPECT (Single Photon Emission Computed Tomography)의 Non-attenuation correction (AC-non) 영상에 대한 attenuation correction(AC) 방법 중 Chang's method와 CT based attenuation correction(AC-CT) 사이의 count를 비교하기 위함이다. phantom study는 증류수로 채워진 hoffman 3D phantom에 $^{99m}Tc$ 37Mbq을 투여하였고, patient study는 normal volunteer에 $^{99m}Tc$-HMPAO 750Mbq를 정맥주입하고 Siemens사의 Symbia T6로 Brain SPECT 영상을 획득하였고 뇌 정량 분석을 하였다. 각각의 방법들을 적용한 transverse image는 같은 위치에서 재구성 되었으며 각각 10, 20, 30번째 slice에서 6개의 region of interest(ROI)를 그려 AC-non 과 AC-CT 그리고 Chang's method의 count를 비교하였다. phantom study에서 AC-non, AC-CT, Chang's method의 각각 평균 count는 $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, $8752.6{\pm}896.5$이었으며 patient study에서 $5460.8{\pm}519.6$, $15320{\pm}1171.6$, $12795{\pm}1422.1$이었다. phantom study에서 AC-CT와 AC-non 사이의 비는 3.70이고 Chang's method와 AC-non 사이의 비는 1.92였으며 patient study에서는 각각 2.85, 2.38이었다. 우리는 이 연구를 통하여 AC-CT가 Chang's method보다 더 높은 AC을 해준다는 걸 알 수 있었다. 그리고 Chang's method는 patient study에서의 AC 값이 phantom study에서의 AC값보다 더 높다는 것을 알 수 있었다. brain SPECT/CT를 시행하는 경우 scatter correction을 같이 시행하고 bone에 의한 감쇠 정보를 반영할 수 있는 AC-CT가 chang's method보다 정확하다 할 수 있겠다.

  • PDF