• 제목/요약/키워드: Tomography, emission computed

검색결과 379건 처리시간 0.021초

The Role of Imaging in Current Treatment Strategies for Pancreatic Adenocarcinoma

  • Hyungjin Rhee;Mi-Suk Park
    • Korean Journal of Radiology
    • /
    • 제22권1호
    • /
    • pp.23-40
    • /
    • 2021
  • In pancreatic cancer, imaging plays an essential role in surveillance, diagnosis, resectability evaluation, and treatment response evaluation. Pancreatic cancer surveillance in high-risk individuals has been attempted using endoscopic ultrasound (EUS) or magnetic resonance imaging (MRI). Imaging diagnosis and resectability evaluation are the most important factors influencing treatment decisions, where computed tomography (CT) is the preferred modality. EUS, MRI, and positron emission tomography play a complementary role to CT. Treatment response evaluation is of increasing clinical importance, especially in patients undergoing neoadjuvant therapy. This review aimed to comprehensively review the role of imaging in relation to the current treatment strategy for pancreatic cancer, including surveillance, diagnosis, evaluation of resectability and treatment response, and prediction of prognosis.

정상 뇌혈류 영상에서 재구성 알고리즘 적용에 따른 섭취율 차이 : 통계적 파라미터 지도를 사용한 분석 (The changes of cerebral blood flow by brain imaging algorithm in the Normal Brains : Analysis by Statistical Parametric Mapping)

  • 이효영;김윤진;신성규
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5311-5316
    • /
    • 2012
  • 뇌 영상분석 알고리즘 적용에 따른 뇌혈류의 변화를 관찰하기 위해 정상 성인 13명(평균연령 39세)을 대상으로 뇌혈류 단 광자 단층촬영(Single Photon Emission Computed Tomography, SPECT)을 시행하였다. 획득된 영상을 여과후 역투영법(Filtered Back Projection, FBP)과 반복적 방법(Ordered Subset Expectation Maximization, OSEM)으로 영상을 재구성하여 통계학적 파라미터 뇌지도법으로 비교하여 방사성 의약품의 뇌 분포양상을 확인하였으며, 혈류의 변화는 크러스트(Cluster)로 표현시켰다. 이에 대한 결과로는 여과후 역투영법이 반복적 방법보다 섭취가 증가된 부위는 우측 전두엽, 대뇌회전하부, 외핵, 좌측대뇌 변엽과 대상이랑이며, 섭취가 감소된 부위는 좌측전두엽, 중간전두이랑, 하측전두이랑, 중심전이랑, 하측전두이랑, 중심전이랑이었다. 이는 영상재구성시 적용되는 알고리즘에 따라 뇌 혈류분포가 다르게 나타난 것을 크러스트(Cluster)로 표현시켰고, 명확한 시각적 표시가 가능하도록 뇌 확룔 지도로 보여주는데 의의가 있다.

SPECT 심근영상의 영상분할을 이용한 3차원 재구성 (3D Reconstruction Using Segmentation of Myocardial SPECT Images)

  • 정재은;이상복
    • 한국방사선학회논문지
    • /
    • 제3권2호
    • /
    • pp.5-10
    • /
    • 2009
  • 심근영상의 SPECT(Single Photon Emission Computed tomography)검사는 감마선을 방출하는 방사성의약품을 환자에게 정맥주사한 후 이 의약품이 심장에 고루 퍼지면 관심부위를 촬영하여 질병으로 인한 변화를 컴퓨터를 이용하여 진단하는 검사법이다. 기능적인 정보를 담고 있는 심근관류 영상은 비침습적인 심근질환 검사에 유용한 방법이지만, 물리적 인자들에 의해 잡음과 낮은 해상도는 판도하는데 어려움을 주게 된다. 본 논문은 심근영상을 레벨 셋 알고리즘을 이용하여 영상을 분할하고 분할된 영역을 3차원으로 구현하여 판독에 도움을 주는 방안을 제안하였다. 판독의 어려움을 해결하기 위하여 레벨 셋을 이용하여 관심부위인 좌심실 영역을 분할하였고 분할된 영역을 3차원영상으로 모델링하였다.

  • PDF

SPECT 심근영상의 영상분할을 이용한 3차원 재구성 (3D Reconstruction Using Segmentation of Myocardial SPECT)

  • 정재은;이준행;최석윤;이상복
    • 한국산학기술학회논문지
    • /
    • 제11권6호
    • /
    • pp.2240-2245
    • /
    • 2010
  • 심근영상의 SPECT(Single Photon Emission Computed tomography)검사는 감마선을 방출하는 방사성의약품을 환자에게 정맥주사한 후 이 의약품이 심장에 고루 퍼지면 관심부위를 촬영하여 질병으로 인한 변화를 컴퓨터를 이용하여 진단하는 검사법이다. 기능적인 정보를 담고 있는 심근관류 영상은 비침습적인 심근질환 검사에 유용한 방법이지만, 물리적 인자들에 의해 잡음과 낮은 해상도는 판도하는데 어려움을 주게 된다. 본 논문은 심근영상을 레벨 셋 알고리즘을 이용하여 영상을 분할하고 분할된 영역을 3차원으로 구현하여 판독에 도움을 주는 방안을 제안하였다. 판독의 어려움을 해결하기 위하여 레벨 셋을 이용하여 관심부위인 좌심실 영역을 분할하였고 분할된 영역을 3차원영상으로 모델링 하였다.

반복법을 사용한 단층영상 재구성을 위한 투사기 및 역투사기의 고속 구현 (Fast Implementations of Projector-Backprojector Pairs for Iterative Tomographic Reconstruction)

  • 김수미;이수진;김용호
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권5호
    • /
    • pp.473-480
    • /
    • 2003
  • 반복법을 사용한 영상재구성은 기존의 여과역투사 방법에 비해 윌등한 장점을 가지고 있으므로 방출 전산화단층촬영에 있어 매우 중요한 역할을 해왔다. 그러나, 반복법을 사용한 영상재구성법은 데이터의 투사 및 역투사 계산의 반복으로 이루어져 있으므로 한 영상을 재구성하는데 필요한 계산량은 알고리즘의 구현을 위해 사용된 투사기 및 역투사기의 성능에 크게 좌우된다. 본 연구에서는 투사기 및 역투사기를 구현하기 위한 대표적 방법들의 성능을 정량적으로 비교한다. 각 구현방법에 있어서 투사-역투사 계산에 필요한 연산량을 줄이기 위해 이전에 계산된 결과들을 재사용함으로써 불필요하게 반복되는 연산들을 최소화하도록 하는 방법에 고찰한다. 실험결과에 의하면 선추적법은 연산속도 면에서 다른 방법에 비해 우수할 뿐 아니라, 정확성이 높은 개선된 영상을 제공하는 것으로 나타났다.

Optimization of block-matching and 3D filtering (BM3D) algorithm in brain SPECT imaging using fan beam collimator: Phantom study

  • Do, Yongho;Cho, Youngkwon;Kang, Seong-Hyeon;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3403-3414
    • /
    • 2022
  • The purpose of this study is to model and optimize the block-matching and 3D filtering (BM3D) algorithm and to evaluate its applicability in brain single-photon emission computed tomography (SPECT) images using a fan beam collimator. For quantitative evaluation of the noise level, the coefficient of variation (COV) and contrast-to-noise ratio (CNR) were used, and finally, a no-reference-based evaluation parameter was used for optimization of the BM3D algorithm in the brain SPECT images. As a result, optimized results were derived when the sigma values of the BM3D algorithm were 0.15, 0.2, and 0.25 in brain SPECT images acquired for 5, 10, and 15 s, respectively. In addition, when the sigma value of the optimized BM3D algorithm was applied, superior results were obtained compared with conventional filtering methods. In particular, we confirmed that the COV and CNR of the images obtained using the BM3D algorithm were improved by 2.40 and 2.33 times, respectively, compared with the original image. In conclusion, the usefulness of the optimized BM3D algorithm in brain SPECT images using a fan beam collimator has been proven, and based on the results, it is expected that its application in various nuclear medicine examinations will be possible.

A new efficient route for synthesis of R,R- and S,S-hexamethylpropyleneamine oxime for labeling with technetium-99m

  • Vinay Kumar Banka;Young Ju Kim;Yun-Sang Lee;Jae Min Jeong
    • 대한방사성의약품학회지
    • /
    • 제6권2호
    • /
    • pp.75-91
    • /
    • 2020
  • [99mTc]Tc-Hexamethylpropylene amine oxime (HMPAO) is currently used as a regional cerebral blood flow imaging agent for single photon emission computed tomography (SPECT). The HMPAO ligand exists in two isomeric forms: d,l and meso showing different properties in vivo. Later studies indicated that brain uptake patterns of 99mTc-complexes formed from separated enantiomers differed. Separation of enantiomers is difficult by fractional crystallizations method. Usually, the substance is obtained in low chemical yield in a time-consuming procedure. Furthermore, the final product still contains some impurity. So we have developed new efficient route for synthesis of R,R- and S,S-HMPAO enantiomeric compounds in 6-steps. Nucleophilic substitution (SN2) reactions of 2,2-dimethylpropane-1,3-diamine either with S- (1a) or R-methyl2-chloropropanoate (1b) were performed to produce compounds R,R- (2a) or S,S-isomer (2b) derivatives protected with benzylchloroformate (Cbz), respectively. And then Weinreb amide and methylation reaction using Grignard reagent, oxime formation with ketone group and deprotectiion of Cbz group by hydrogenolysis gave S,S- (7a) or R,R-HMPAO (7b), respectively. Entaniomeric compounds were synthesied with high yield and purity without any undesired product. The 7a or 7b kits containing 10 ㎍ SnCl2-2H2O were labeled with 99mTc with high radiolabeling yield (90%).

뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구 (A study on image registration and fusion of MRI and SPECT/PET)

  • 주라형;최용;권수일;허수진
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.47-53
    • /
    • 1998
  • 방사성 의약품 또는 방사성 동위원소를 이용하여 동적 상태의 변화를 측정하고 핵자기 공명 영상에서 해부학적 기준 정보를 얻어 영상을 융합, 등록하고 같은 대상에서 비슷한 검사를 계속해서 비교하게 되며 해부학적 기준 정보나 다른 검사 기기 종류에서 반복되는 검사의 비교를 위해 영상 합성 연구가 유효하며 기능적 특성 때문에 단일 광자 방출 전산화 단층 촬영과 양전자 방출 단층 촬영은 해부학적 기준 정보가 필요하게 되고 같은 대상에서 이러한 해부학적 기준 정보를 얻고 기능적인 이상과 상관관계를 찾아내고 반복되는 진단에 대한 비교를 위해서 영상등록과 융합을 시행하였다. 해부학적 구조가 같은 특성을 갖는 여러 영상 시스템들을 이용하여 해부학적기준과 동적 정보를 함께 얻고 등록하기 위해 짝을 이루는 점올 이용하여 2 가지 영상 데이터에서 4 점 쌍 이상을 선택하여 등록하였다. 기준 영상과 짝을 이루는 점과 대응한 영상은 다른 색을 선택하여 영상을 구분하였으며 핵자기 공명영상을 기준영상으로 하고 단일 광자 방출 컴퓨터 단층 촬영 영상, 양전자 방출 전산화 단층 촬영 영상을 기준영상에 1:1 대응하여 영상을 등록하기 위해서 변환한다. 핵자기 공명 영상이 기준 영상으로 사용되지만 인터폴레이션 에러는 주어진 영상의 공간 주파수에 따라 달라지므로 낮은 해상도를 갖는 양전자 방출 전산화 단층 촬영 영상과 단일 광자 방출 컴퓨터 단층 촬영 영상의 인터폴레이션 에러는 적다. 따라서 방사성 동위원소를 이용하여 질병의 진단 및 질환의 병태 생리 생화학적 연구를 통한 신체의 동역학적 상태의 변화를 측정할 수 있는 이런 정량적이고 기능적인 정보를 해부학적 기준 정보를 주는 핵자기 공명 영상이나 컴퓨터 단층 촬영에서 반복 시행하여 검사와 진단에 용이하게 이용하고, 비교를 위해서 영상을 등록하고 융합하여 진단에 보다 좋은 결과를 얻을 수 있도록 하였다.

  • PDF

Gamma Knife Radiosurgery Using Co-Registration with PET-CT and MRI for Recurrent Nasopharyngeal Carcinoma with Previous Radiotherapy : A Single Center 14-Year Experience

  • Lee, Chaejin;Park, Seong-Hyun;Yoon, Sang-Youl;Park, Ki-Su;Hwang, Jeong-Hyun;Hwang, Sung-Kyoo
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권3호
    • /
    • pp.397-405
    • /
    • 2020
  • Objective : We retrospectively evaluated the efficacy of Gamma Knife radiosurgery (GKS) for recurrent nasopharyngeal carcinoma (NPC) in patients who previously underwent radiotherapy, and analyzed the treatment outcomes over 14 years. Methods : Ten patients with recurrent NPC who had previously received radiotherapy underwent stereotactic radiosurgery using a Gamma Knife® (Elekta Inc, Atlanta, GA, USA) between 2005 and 2018. The median target volume was 8.2 ㎤ (range, 1.7-17.8), and the median radiation dose to the target was 18 Gy (range, 12-30). The median follow-up period was 18 months (range, 6-76 months). Overall and local failure-free survival rates were determined using the Kaplan-Meier method. Results : The NPCs recurred at the primary cancer site in seven patients (70%), as distant brain metastasis in two (20%), and as an extension into brain in one (10%). The recurrent tumors in seven of the 10 patients (70%) were found on the routine follow-up imaging studies. Two patients presented with headache and one with facial pain. Local failure after GKS occurred in five patients (50%) : two of whom died eight and 6 months after GKS, respectively. No adverse radiation effects were noted after GKS. The 1- and 3-year overall survival rates after GKS were 90% and 77%, respectively. The local failure-free survival rates at 6 months, 1 year, and 3 years after GKS were 80%, 48%, and 32%, respectively. The median interval from GKS to local failure was 8 months (range, 6-12). Univariate analysis revealed that using co-registration with positron emission tomography-computed tomography (PET-CT) and magnetic resonance imaging (MRI) was associated with a lower local failure rate of recurrent NPC (p=0.027). Conclusion : GKS is an acceptable salvage treatment option for patients with recurrent NPC who previously received radiation therapy. PET-CT and MRI co-registration for dose planning can help achieve local control of recurrent NPC.

Significance of Hormone Receptor Status in Comparison of 18F -FDG-PET/CT and 99mTc-MDP Bone Scintigraphy for Evaluating Bone Metastases in Patients with Breast Cancer: Single Center Experience

  • Teke, Fatma;Teke, Memik;Inal, Ali;Kaplan, Muhammed Ali;Kucukoner, Mehmet;Aksu, Ramazan;Urakci, Zuhat;Tasdemir, Bekir;Isikdogan, Abdurrahman
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권1호
    • /
    • pp.387-391
    • /
    • 2015
  • Background: Fluorine-18 deoxyglucose positron emission tomography computed tomography (18F-FDG-PET/CT) and bone scintigraphy (BS) are widely used for the detection of bone involvement. The optimal imaging modality for the detection of bone metastases in hormone receptor positive (+) and negative (-) groups of breast cancer remains ambiguous. Materials and Methods: Sixty-two patients with breast cancer, who had undergone both 18F-FDG-PET/CT and BS, being eventually diagnosed as having bone metastases, were enrolled in this study. Results: 18F-FDG-PET/CT had higher sensitivity and specificity than BS. Our data showed that 18F-FDGPET/CT had a sensitivity of 93.4% and a specificity of 99.4%, whiel for BS they were 84.5%, and 89.6% in the diagnosis of bone metastases. ${\kappa}$ statistics were calculated for 18F-FDGPET/CT and BS. The ${\kappa}$-value was 0.65 between 18F-FDG-PET/CT and BS in all patients. On the other hand, the ${\kappa}$-values were 0.70 in the hormone receptor (+) group, and 0.51 in hormone receptor (-) group. The ${\kappa}$-values suggested excellent agreement between all patient and hormone receptor (+) groups, while the ${\kappa}$-values suggested good agreement in the hormone receptor (-) group. Conclusions: The sensitivity and specificity for 18F-FDG-PET/CT were higher than BS in the screening of metastatic bone lesions in all patients. Similarly 18F-FDG-PET/CT had higher sensitivity and specificity in hormone receptor (+) and (-) groups.