Among the detector materials available at room temperature, thallium bromide (TlBr), which has a relatively high atomic number and density, is widely used for gamma camera imaging. This study aimed to verify the usefulness of TlBr through quantitative evaluation by modeling detectors of various compound types using Monte Carlo simulations. The Geant4 application for tomographic emission was used for simulation, and detectors based on cadmium zinc telluride and cadmium telluride materials were selected as a comparison group. A pixel-matched parallel-hole collimator with proven excellent performance was modeled, and phantoms used for quality control in nuclear medicine were used. The signal-to-noise ratio (SNR), contrast to noise ratio (CNR), sensitivity, and full width at half maximum (FWHM) were used for quantitative analysis to evaluate the image quality. The SNR, CNR, sensitivity, and FWHM for the TlBr detector material were approximately 1.05, 1.04, 1.41, and 1.02 times, respectively, higher than those of the other detector materials. The SNR, CNR and sensitivity increased with increasing detector thickness, but the spatial resolution in terms of FWHM decreased. Thus, we demonstrated the feasibility and possibility of using the TlBr detector material in comparison with commercial detector materials.
Magnetic resonance imaging (MRI) is an imaging technique used to produce high quality images of the inside of the animal body. MRI is based on the principles of nuclear magnetic resonance (NMR) and started out as a tomographic imaging technique, that is it produced an image of the NMR signal in a thin slice through the animal body. The animal body is primarily fat and water, Fat and water have many hydrogen atoms. Hydrogen nuclei have an NMR signal. For these reasons magnetic resonance imaging primarily images the NMR signal from the hydrogen nuclei. Hydrogen protons, within the body align with the magnetic field. By applying short radio frequency (RF) pulses to a specific anatomical slice, the protons in the slice absorb energy at this resonant frequency causing them to spin perpendicular to the magnetic field. As the protons relax back into alignment with the magnetic field, a signal is received by an RF coil that acts as an antennae. This signal is processed by a computer to produce diagnostic images of the anatomical area of interest.
A 3-month-old intact male Lakeland terrier was presented with recurring regurgitation after removing cervical esophageal foreign body by endoscopy. Blood and urine analysis, radiography, ultrasonography, fluoroscopic esophagography, computed tomographic angiography (CTA) were performed. In radiography and fluoroscopic esophagography, vascular ring anomaly was considered as the primary cause of megaesophagus, and CTA with gas-inflation of the esophagus was performed. Compressed esophagus, persistent right aortic arch (PRAA), aberrant left subclavian artery (LSA), and a venous structure which was confirmed in surgery to be incomplete type persistent left cranial vena cava (PLCVC) connected with the left side azygos vein were observed. Left deviation of the trachea was also revealed in CT, which implies the compression by left ligamentum arteriosum. Therefore, type 3 PRAA with left ligamentum arteriosum and aberrant LSA, was considered as a prior differential diagnosis. Surgical repair was performed and the clinical signs improved. This report describes CTA characteristics of combination of PRAA with aberrant LSA, incomplete PLCVC and Lt. azygos vein in a dog. Although not every vascular anomaly does induce clinical sign, some types can complicate the surgical procedure, and cause clinical signs. Therefore, thorough evaluation of vascular anomalies in the thorax is important, and CTA is a useful method in identifying multiple vascular anomalies in dogs.
Background: Gastroesophageal reflux (GER) has been reported to be a common finding in dogs under general anesthesia. Objectives: The aim of this retrospective study was to assess the esophageal and gastric contents in a population of dogs undergoing computed tomographic myelography (myeloCT) examination and to evaluate the factors influencing the presence of esophageal fluid (gastric content, duration of anesthesia, body position, and intrinsic factors). Methods: Esophageal and gastric contents of 83 non-brachycephalic dogs were retrospectively assessed based on plain and myelo-CT scans. Age, weight, breed, sex, and the time between the 2 computed tomography [CT] scans were included. Results: Esophageal fluid was present in 19% (16/83) of the animals, and 14% (12/83) and 46% (37/83), respectively, had fluid or food material in their stomachs. The frequency of observing esophageal fluid on myelo-CT scans was significantly increased compared with plain CT scans (p = 0.006). The presence of gastric fluid was significantly associated with an increased frequency of observing esophageal fluid compared to other gastric contents (p = 0.049; odds ratio, 3.1). The presence of esophageal fluid was not correlated with alimentary gastric contents (p = 0.17). Increased body weight and duration of anesthesia were significantly associated with an increased frequency of observing esophageal fluid (p = 0.022, p = 0.021). Conclusions: Unlike alimentary gastric contents, fluid gastric contents were correlated with the presence of esophageal fluid upon myelo-CT. The observation of fluid in the esophagus may be consistent with GER. This study provides data additional to pH monitoring studies of GER and may support previous studies recommending shorter pre-anesthetic fasting periods in dogs.
Purpose: To find out the effects that different tomographic angles have on the osteophytic lesion detectability of condyle head by comparison the individualized lateral tomographic image with the various tomographic angled images using SCANORA/sup (R)/. Materials & Methods: This study is performed to simulate osteophytic lesions by a series of dentin chips placed at six locations on condyle head. The control angle is 15° and from this angle. tomographic angle were varied with -10°, +10°, +20°. All the images with each sized dentin chip were scored by three dental radiologists with the use of confidence levels for presence or absence of the lesion, each examiner viewed one of the images twice. A rating scale from 0 to 2 (0, lesion definitely not present; 1. uncertain if lesion is present; 2, lesion definitely present). Responses were assessed by Tukey' s multiple comparison method and kappa value. Results: 1. The lesion size of 0.3 mm could not be detected in all the tomographic angles. As the size of the lesion increased the average value of lesion detectability also increased. 2. In the lesion sizes of 0.7 mm there was statistically significant difference between the 15° control angle and the altered tomographic angles (p<0.05). In 1.0 mm lesion there was no significant difference in the ±10° altered angles (p >0.05). but there was significant difference in the altered angle (p<0.05). In the lesion sizes of 0.3 mm and 2.0 mm there was no significant difference between the 15° control angle and all the altered angles (p >0.05). 3. In the anteromedial. anterosuperior, anterolateral area there was no significant difference between the 15° control angle and the ±10° altered angle (p >0.05), but in the comparison with the +20° altered angle there was significant difference (p<0.05). Conclusion: When imaging the lateral tomography of the temporomandibular joint used by SCANORA/sup (R)/, it can be considered that in the osteophytic lesion size of 2 mm and above, the tomographic angle difference within +20° to the horizontal angle of the condyle. has little effect on the lesion detectability. And in the lesion size of 1 mm, the altered angle within ±10° also has little effect on the lesion detectability.
Kim, Rakhoon;An, Soyon;Hwang, Gunha;Ryu, Jeongmin;Kim, Minji;Yoon, Jiwon;Noh, Seul Ah;Yu, DoHyeon;Lee, Hee Chun;Hwang, Tae Sung
대한수의학회지
/
제62권3호
/
pp.23.1-23.5
/
2022
A 5-year-old castrated male domestic shorthair cat was referred for further investigation of pulmonary nodules incidentally detected on thoracic radiographs. Thoracic radiographs identified ill-defined soft tissue opacity nodules with small faint mineral opacity. Thoracic computed tomography (CT) revealed that bronchial dilation and bronchial wall thickening in bilateral cranial and accessory lung lobes. Round to ellipsoid mineralized concretions were found embedded in the intrabronchial soft tissue attenuation material. Based on radiography, CT, and cytology, the patient was tentatively diagnosed as having broncholithiasis with chronic bronchitis. This report described the CT diagnosis of broncholithiasis, which has been rarely reported in a cat.
지금까지 마이크로웨이브 영상은 주로 파수영역의 해석에 의해 2차원 푸리에 역변환으로 물체의 영상을 재현하였다. 본 논문에서는 공간영역에서 코히어런트 단층촬영 방법으로 영상을 제한할 수 있는 새로운 식을 유도하고 X-ray 단층촬영에 널리 이용되고 있는 filtered-backprojection 알고리듬을 적용하여 line 및 원통 도체에 대한 영상을 수치계산에 의해 재현하였다. 제시된 공간영역의 해석은 기존의 파수영역의 문제점인 interpolation 및 원점에 대칭인 도체의 영상재현시 나타나는 영상의 artifact을 완전히 해결할 수 있음은 물론, 보다 좋은 영상의 질을 얻을 수 있었다. 또한 파수영역의 해석과는 달리, 모멘트 방법을 적용하여 좁은 주파수 대역폭으로도 초고해상도를 얻을 수 있는 가능성을 line 물체의 영상을 통해 보였다.
Uses a Tomographic scan image and Table Object Distance(TOD) price after measuring, uses accuracy and usability of blood vessel diameter(Vessel Diameter) measurement under comparison evaluating boil TOD Calibration. The patient who enforces Prosecuting Attorney abdomen Tomographic scan in the object the superior mesentery artery uses PACS View from abdomen fault image and from blood vessel diameter and the table measures the height until of the blood vessel. Uses Angio Catheter from Angiography(5 Fr.) and enforces is measured from PACS View the height until of the table which and the blood vessel at TOD Calibration price and the size of the superior mesentery artery inputs measures an superior mesentery artery building skill. Catheter Calibration input Agnio Catheter where uses in Angiography the size of the superior mesentery artery at Catheter Calibration price and they measure. Produced an accuracy from monitoring data and comparison evaluated. The statistical program used SPSS. TOD Calibration accuracy was 96.53%, standard deviation is 0.03829. Catheter Calibration accuracy of 92.91%, standard deviation is 0.05085. Represents a statistically significant difference(p = 0). According to age and gender was not statistically significant(p > 0.05). TOD Calibration correlation coefficient R-squared of 88.8%, Catheter Calibration of the R-squared is 75.5%. High accuracy of both methods. Through this study, CT images using the measured distance between the table and the Object, TOD Calibration accuracy higher than two Catheter Calibration was measured. TOD and Catheter Calibration represents a statistically significant difference(p = 0).
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.