• Title/Summary/Keyword: Tm3+

Search Result 2,033, Processing Time 0.024 seconds

Molecular Modeling of the Subtype Dopamine Receptor-ligand Interactions

  • Baek, Minkyung;Shin, Woong-Hee
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.13-24
    • /
    • 2013
  • Dopamine agonists and antagonists and its receptor play a critical role in the information transfer in the nervous system, and dopamine receptor-ligands interactions are deeply related to Parkinson's disease, schizophrenia and some other mental diseases. However, the only experimental 3D structure available for dopamine receptors is human D3 dopamine receptor. Therefore, it is important to create model of subtype dopamine receptor-ligands interactions. We report here the 3D structures of the human D1 and D2 dopamine receptor predicted by using GalaxyTBM, and its predicted binding site determined by using GalaxyDock. The highly conserved Asp on TM 3 and Phe on TM 6 have critical role in ligand binding. Also, highly conserved serines on TM 5 are essential for binding agonists and some kinds of antagonists. We identify differences between binding sites of agonists and antagonists of human D1 and D2 dopamine receptor, and find the reasons of selective binding of antagonists.

  • PDF

THE EFFECT OF IRRADIATION MODES ON POLYMERIZATION AND MICROLEAKAGE OF COMPOSITE RESIN (광조사 방식이 복합레진의 중합과 누출에 미치는 영향)

  • Park, Jong-Jin;Park, Jeong-Won;Park, Sung-Ho;Park, Ju-Myong;Kwon, Tae-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.158-174
    • /
    • 2002
  • The aim of this study was to investigate the effect of light irradiation modes on polymerization shrinkage, degree of cure and microleakage of a composite resin. VIP$^{TM}$ (Bisco Dental Products, Schaumburg, IL, USA) and Optilux 501$^{TM}$ (Demetron/Kerr, Danbury, CT, USA) were used for curing Filtek$^{TM}$ Z-250 (3M Dental Products, St. Paul., MN, USA) composite resin using following irradiation modes: VIP$^{TM}$ (Bisco) 200mW/$\textrm{cm}^2$ (V2), 400mW/$\textrm{cm}^2$ (V4), 600mW/$\textrm{cm}^2$ (V6), Pulse-delay (200 mW/$\textrm{cm}^2$ 3 seconds, 5 minutes wait, 600mW/$\textrm{cm}^2$ 30seconds, VPD) and Optilux 501$^{TM}$ (Demetron/Kerr) C-mode (OC), R-mode (OR). Linear polymerization shrinkage of the composite specimens were measured using Linometer (R&B, Daejeon, Korea) for 90 seconds for V2, V4, V6, OC, OR groups and for up to 363 seconds for VPD group (n=10, each). Degree of conversion was measured using FTIR spectrometer (IFS 120 HR, Bruker Karlsruhe, Germany) at the bottom surface of 2 mm thick composite specimens V2, Y4, V6, OC groups were measured separately at five irradiation times (5, 10, 20, 40, 60 seconds) and OR, VPD groups were measured in the above mentioned irradiation modes (n=5 each). Microhardness was measured using Digital microhardness tester (FM7, Future-Tech Co., Tokyo, Japan) at the top and bottom surfaces of 2mm thick composite specimens after exposure to the same irradiation modes as the test of degree of conversion(n=3, each). For the microleakage test, class V cavities were prepared on the distal surface of the ninety extracted human third molars. The cavities were restored with one of the following irradiation modes : V2/60 seconds, V4/40 seconds, V6/30 seconds, VPD , OC and OR. Microleakage was assessed by dye penetration along enamel and dentin margins of cavities. Mean polymerization shrinkage, mean degree of conversion and mean microhardness values for all groups at each time were analyzed using one-way ANOVA and Duncan's multiple range test, and using chi-square test far microleakage values. The results were as follows : . Polymerization shrinkage was increased with higher light intensity in groups using VIP$^{TM}$ (Bisco) : the highest with 600mW/$\textrm{cm}^2$, followed by Pulse-delay, 400mW/$\textrm{cm}^2$ and 200mW/$\textrm{cm}^2$ groups, The degree of polymerization shrinkage was higher with Continuous mode than with Ramp mode in groups using Optilux 501$^{TM}$ (Demetron/Kerr). . Degree of conversion and microhardness values were higher with higher light intensity. The final degree of conversion was in the range of 44.7 to 54.98% and the final microhardness value in the range of 34.10 to 56.30. . Microleakage was greater in dentin margin than in enamel margin. Higher light intensity showed more microleakage in dentin margin in groups using VIP$^{TM}$ (Bisco). The microleakage was the lowest with Continuous mode in enamel margin and with Ramp mode in dentin margin when Optilux 501$^{TM}$ (Demetron/Kerr) was used.

Post-thawed Preimplantation Development and Production of Offsprings after Vitrification using Taxol $^{TM}$ a Cytoskeleton Stabilizer (마우스 성숙난자의 유리화 동결 중 Cytoskeleton Stabilizer, Taxol의 처리 후 배발달률과 산자의 생산)

  • 박성은;박이석;정형민
    • Journal of Embryo Transfer
    • /
    • v.16 no.3
    • /
    • pp.239-243
    • /
    • 2001
  • Selection of oocyte cryopreservation method is a prerequisite factor for developing an effective bank system. Compared with slow freezing method, the vitrification has various advantages such as avoiding intracellular ice crustal formation. In our previous, we attempted to employ a vitrification method using ethylene glycol and an electron microscope grid for cryopreservation of mouse oocytes. However, A high incidence of spindle and chromosome abnormalities was detected in thawed oocytes after vitrification. We examined whether the addition of a cystoskeleton stabilizer Taxol $^{TM}$, to the vitrification solution could promote the post-thawed survival and subsequent development of stored oocytes. More oocytes developed to the 4-cell (44.7% vs. 69.7%), 8-cell (31.8% vs. 64.2%), morula (24.7% vs. 54.3%), and blastocyst (20.3% vs. 49.2%) stages after the addition of Taxol$^{TM}$ to the cryoprotectant than after no addition. 21 and 26 mouse pups were born after transfer of blastocyst derived from oocytes vitrified without and with Taxol. The addition of Taxol to vitrification solution greatly promoted post-thaw preimplantation development of ICR morose oocytes.tes.

  • PDF

Blade Development and Test of WinDS$3000^{TM}$ System (WinDS$3000^{TM}$ 시스템의 블레이드 개발 및 시험)

  • Lee, Sang-Il;Lee, Kyeong-Woo;Joo, Wan-Don;Lee, Ki-Hak;Park, Jong-Po
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.448-448
    • /
    • 2009
  • A new blade has been developed to apply to Doosan 3MW offshore wind turbine named as WinDS3000TM. The 3MW blade has been designed by the concept of slim external shape and optimized structure. High-performance glass fiber reinforced epoxy composites were used as the main material of the blade. The blade was manufactured using vacuum infusion process in order to increase the fiber volume fraction and to reduce micro-porosities. The blade has successfully passed the full-scale blade static test for certification. During the test, micro-failure signal and strain change of the blade were measured using acoustic emission sensors and strain gages. The blade has robust structure and weighs lighter compared to conventional blade since the new blade was designed by optimization process. The 3MW blade will be commercially applied to WinDS$3000^{TM}$ in 2010.

  • PDF

Investigation of Dietary Lysophospholipid (LipidolTM) to Improve Nutrients Availability of Diet with In Vitro Rumen Microbial Fermentation Test

  • Cho, Sangbuem;Kim, Dong Hyun;Hwang, Il Hwan;Choi, Nag-Jin
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.33 no.3
    • /
    • pp.206-212
    • /
    • 2013
  • This study was conducted to investigate the effect of biological membrane transfer modifier, lysophospholipd (LPLs) on the parameters from in vitro rumen simulated fermentation. Commercially available LPLs product (Lipidol$^{TM}$) was supplemented into experimental diets which consisted of orchard grass and concentrate diet (60:40) in different levels (0.1%, 0.3% and 0.5%). Then in vitro rumen simulated fermentation was performed. Although, a declining trend of pH was found in treatments, all pH values were detected in a range relevant to normal rumen fermentation. Gas production, ammonia nitrogen and total VFA production were greatly influenced by the supplementation of LPLs. All parameters were increased along with increased levels of LPLs in diet. As a result, 0.1% of Lipidol$^{TM}$ is recommended based on the determined in vitro rumen fermentative parameters in this study.

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.

The analysis of differences of mean basin precipitation between TM and radar using correlation with basin characteristics and rainfall patterns (TM과 레이더를 이용한 유역평균강수량 차이와 유역특성 및 강우형태와의 상관성)

  • Park, Jaeheyon;Sung, Janghyun;Cho, Yohan;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.7
    • /
    • pp.469-480
    • /
    • 2020
  • This study analyzed the differences of mean basin precipitation between TM and radar based on the 51 standard basins in Han river and Nakdong river when large scale of heavy rains occurred in 2018. The result shows that the differences between radar and TM are -65.05 ~ 26.09% and -82.00 ~ 3.80% for accumulated and 10 min. maximum mean basin precipitation, respectively. The correlation analysis between the differences of estimated mean basin precipitation and basin characteristics such as average altitude of basin, area of basin, and shape factor of basin presents that there is no clear correlation between them. And the differences of point precipitation also shows the similar tendency with those of mean basin precipitation. In order to find out the correlation between them and meteorological conditions such as rainfall patterns, the reflectivity of radars according to the observation angles is analyzed at the selected basins, and then it is found that the differences of mean basin precipitation between TM and radar is more dominated by the meteorological conditions than by the topographic conditions such as basin characteristics.

Development of K-$Touch^{TM}$ API for kinesthetic/tactile haptic interaction (역/촉감 햅틱 상호작용을 위한 "K-$Touch^{TM}$" API 개발 - 햅틱(Haptic) 개발자 및 응용분야를 위한 소프트웨어 인터페이스 -)

  • Lee, Beom-Chan;Kim, Jong-Phil;Ryu, Je-Ha
    • Journal of the HCI Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.1-8
    • /
    • 2006
  • This paper presents a development of new haptic API (Application Programming Interface) that is called K-$Touch^{TM}$ haptic API. It is designed in order to allow users to interact with objects by kinesthetic and tactile modalities through haptic interfaces. The K-$Touch^{TM}$ API would serve two different types of users: high level programmers who need an easy to use haptic API for creating haptic applications and researchers in the haptic filed who need to experiment or develop with new devices and new algorithms while not wanting to re-write all the required code from scratch. Since the graphic hardware based kinesthetic rendering algorithm implemented in the K-$Touch^{TM}$ API is different from any other conventional kinesthetic algorithms, this API can provide users with haptic interaction for various data representations such as 2D, 2.5D depth(height field), 3D polygon, and volume data. In addition, this API supports kinesthetic and tactile interaction simultaneously in order to allow users with realistic haptic interaction. With a wide range of applicative characteristics, therefore, it is expected that the proposed K-$Touch^{TM}$ haptic API will assists to have deeper recognition of the environments, and enhance a sense of immersion in environments. Moreover, it will be useful development toolkit to investigate new devices and algorithms in the haptic research field.

  • PDF

The Bioequivalence of Two Carbamazepine Controlled Release Formulations (카르바마제핀 서방형 제제간의 생물학적 동등성 비교)

  • Kim, Min J.;Lee, Hyun J.;Rheu, Yoon M.;Shin, Wan G.;Park, Sung H.
    • Korean Journal of Clinical Pharmacy
    • /
    • v.6 no.2
    • /
    • pp.19-23
    • /
    • 1996
  • Carbamazepine is an anticonvulsant drug that has been shown to be as effective as phenytoin or phenobarbital in treatment of grand mal and complex partial seizures and is also approved as the drug of choice for treatment of the pain associated with trigerminal neuralgia. And the therapeutic or toxic effects of carbamazepine are better related to plasma concentration than to dosage, which can be attributed to interindividual variability in the pharmacokinetics. A slow rate of carbamazepine dissolution in the gastrointestinal tract is believed to be the cause of its relatively slow and erratic rate of absorption. For these reasons pharmacokinetic evaluation of newly formulated carbamazepine is neccessary. In this study, the bioequivalence in carbamazepine between the $TegretoI^{TM}$ CR tablet (Geigy Co.) and $Carmazepine^{TM}$ CR tablet (Myung In Co.) was evaluated. 12 normal volunteers (age $21\~27$ years old) was divided into two groups, and a randomized cross-over study was employed. The pharmacokinetic parameters ($C_{max},\;T_{max}$ and AUC) obtained of oral administration of each formulatim of carbamazepine 400 mg were evaluated and ANOVA was utilized for the statistical analysis of parameters. $C_{max}\;is\;8.26{\pm}3.1{\mu}g/ml\;(C.V.\;37.3\%)\;in\;TegretoI^{TM}\;and\;9.39\{pm}2.9{\mu}g/ml\;(C.V.\;30.5\%)$ in $Carmazepine^{TM},\;T_{max}\;is\;28.0{\pm}5.9\;hrs(C.V.\;21.1\%)$ in $Tegretol^{TM}\;and\;24.0{\pm}7.2\;hrs(C.V.\;30.2\%)$ in $Carmazepine^{TM}$ and AUC is $786.4{\pm}360.5{\mu}g{\cdot}hr/ml\;(C.V.\;45.8\%)$ in $TegretoI^{TM}\;and\;792.8{\pm}228.6{\mu}g{\cdot}hr/ml\;(C.V.\;28.8\%)$ in $Carmazepine^{TM}$, respectively. As the result of the data, two formulations are bioequvalent, and the lower C.V. of $Carmazepine^{TM}$ in every individual can be merit.

  • PDF

A Study on the Adsorption of Rare Earth Elememts by Raw and Crosslinked Chitosan (천연 및 가교 키토산에 의한 희토류 원소의 흡착과 회수에 관한 연구)

  • Cho, Sung-Ill;Choi, Jong-Moon;Kim, Young-Sang;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.108-116
    • /
    • 2004
  • The adsorption characteristics of raw and crosslinked chitosan for rare earth elements (REEs) have been studied. The range of optimum pH for the maximum adsorption was observed: pH 4.5~5.5 for $Nd^{3+}$, $Tm^{3+}$ on raw and crosslinked chitosan; pH 4.0~5.5 for $La^{3+}$ and $Ce^{3+}$ on crosslinked chitosan and pH 2.0 for those on raw chitosan. The adsorption rate of REE at pH 4.0 has been found in the order of $Er^{3+}$ > $Gd^{3+}$ > $Yb^{3+}$ > $Nd^{3+}$ > $Lu^{3+}$ > $Eu^{3+}$ > $Tm^{3+}$ > $Ho^{3+}$ > $Dy^{3+}$ > $La^{3+}$ > $Ce^{3+}$ > $Y^{3+}$ > $Pr^{3+}$ in single metal system and that of $Lu^{3+}$ > $Yb^{3+}$ > $Tm^{3+}$ > $Dy^{3+}$ > $Ho^{3+}$ > $Er^{3+}$ > $Eu^{3+}$ > $Gd^{3+}$ > $Nd^{3+}$ > $Y^{3+}$ > $La^{3+}=Ce^{3+}=Pr^{3+}$ in multi metal system. In the competitive adsorption of multi metal system, the amount of metal adsorption generally increased with increasing atomic number and with decreasing ionic radius. On the adsorption studies of metal ions on chitosan, the time of equilibrium adsorption which was reached at the maximum adsorption was about 5 hours. 83~95 % for $Nd^{3+}$ ion and 90~106 % for $Tm^{3+}$ ion, were recovered from the crosslinked chitosan.