• 제목/요약/키워드: Tm3+

검색결과 2,032건 처리시간 0.025초

Molecular Modeling of the Subtype Dopamine Receptor-ligand Interactions

  • Baek, Minkyung;Shin, Woong-Hee
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제2회(2013년)
    • /
    • pp.13-24
    • /
    • 2013
  • Dopamine agonists and antagonists and its receptor play a critical role in the information transfer in the nervous system, and dopamine receptor-ligands interactions are deeply related to Parkinson's disease, schizophrenia and some other mental diseases. However, the only experimental 3D structure available for dopamine receptors is human D3 dopamine receptor. Therefore, it is important to create model of subtype dopamine receptor-ligands interactions. We report here the 3D structures of the human D1 and D2 dopamine receptor predicted by using GalaxyTBM, and its predicted binding site determined by using GalaxyDock. The highly conserved Asp on TM 3 and Phe on TM 6 have critical role in ligand binding. Also, highly conserved serines on TM 5 are essential for binding agonists and some kinds of antagonists. We identify differences between binding sites of agonists and antagonists of human D1 and D2 dopamine receptor, and find the reasons of selective binding of antagonists.

  • PDF

광조사 방식이 복합레진의 중합과 누출에 미치는 영향 (THE EFFECT OF IRRADIATION MODES ON POLYMERIZATION AND MICROLEAKAGE OF COMPOSITE RESIN)

  • 박종진;박정원;박성호;박주명;권태경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.158-174
    • /
    • 2002
  • Filtek$^{TM}$ Z-250(3M Dental Products, St. Paul., MN. USA) 광중합형 복합레진을 대상으로 다양한 광조사 방식이 중합수축, 중합도 및 미세누출에 미치는 영향을 알아보고자 하였다. VIP$^{TM}$(Bisco Dental Products, Schaumburg, IL, USA)를 이용하여 200, 400 및 600mW/$\textrm{cm}^2$의 일정한 광도로 중합시킨 세 군(V2, V4 및 V6군)과 200mW/$\textrm{cm}^2$의 광도로 3초간 중합시키고 5분간 방치 한 후 다시 600mW/$\textrm{cm}^2$의 광도로 중합시키는 pulse-delay 방식을 이용한 군(VPD군) 그리고 Optilux 501$^{TM}$(Demetron/Kerr, Danbury, CT, USA)을 이용하여 C-mode와 R-mode로 중합시킨 두 군(OC군, OR군) 등 모두 6개의 군으로 나누어 실험하였으며, 복합레진의 중합과 누출을 다음의 네 가지 방법으로 측정하였다. 첫째, V2, V4, V6, OC군은 60초간, OR군은 20초간 그리고 VPD군은 두번째 광조사를 60초간 시행하면서 시간에 따른 선형 중합수축을 Linometer(R&B, Daejeon, Korea)로 측정하였다. 둘째, V2, V4, V6, OC군은 각각 5, 10, 20, 40, 60초간 그리고 OR군과 VPD군은 정해진 조건에 따라 중합시킨 2mm 두께 시편의 바닥면에서 시료를 채취한 후 KBr method로 시편을 제작하고, FTIR spectrometer(IFS 120 HR, Broker, Karlsruhe, Germany)로 미반응 잔류단량체의 양을 계측하여 중합도를 측정하였다. 셋째, 두번째 실험과 같은 조건으로 중합시킨 2mm 두께 시편의 광조사면과 바닥면에서 중합 10분 후 미세경도 측정기(FM7, Future-Tech Co., Tokyo, Japan)로 500g의 하중을 10초간 가하여 Knoop Hardness Number(KHN) 값을 측정하였다. 끝으로, 90개의 발거치 치경부에 제5급 와동을 형성하고 V2군은 60초간, V4군은 40초간, V6군은 30초간 그리고 OC, OR, VPD군은 정해진 조건에 따라 중합시킨 후, methylene blue 용액에 침적시키고 종절단하여 법랑질과 상아질 변연의 미세누출 정도를 측정하였다. 중합수축. 중합도 및 미세경도 측정치는 one-way ANO-VA와 Duncan's multiple range test를, 변연누출 정도는 chi-square test를 이용, 통계처리하여 다음의 결과를 얻었다. . 중합수축의 정도는 VIP$^{TM}$(Bisco) 사용군에서 전체 조사광도가 높을수록 큰 경향을 보여 600mW/$\textrm{cm}^2$군에서 가장 크게 나타났고, 그 다음으로 Pulse-delay군, 400mW/$\textrm{cm}^2$군, 200 mW/$\textrm{cm}^2$군 순이었고, Optilux 501$^{TM}$(Demetron/Kerr) 사용군에서는 Continuous 방식이 Ramp 방식 보다 크게 나타났다. . 중합도와 미세경도 값은 공히, 전체 조사광도가 높을수록 높게 나타났으며 , 최종 중합도는 44.77~54.98%의 범위를, 미세경도 값은 34.10~56.30의 범위를 보였다. . 미세누출은 전반적으로 상아질 변연이 법랑질 변연에 비해 많았고, VIP$^{TM}$(Bisco) 사용 군에서는 광도가 높을수록 상아질 변연에서 미세누출이 증가하는 양상을 보였으며, 법랑질 변연에서는 Optilux 501$^{TM}$(Demetron/Kerr)의 Continuous 방식이, 상아질 변연에서는 Ramp 방식이 가장 적은 미세누출을 보였다.

마우스 성숙난자의 유리화 동결 중 Cytoskeleton Stabilizer, Taxol의 처리 후 배발달률과 산자의 생산 (Post-thawed Preimplantation Development and Production of Offsprings after Vitrification using Taxol $^{TM}$ a Cytoskeleton Stabilizer)

  • 박성은;박이석;정형민
    • 한국수정란이식학회지
    • /
    • 제16권3호
    • /
    • pp.239-243
    • /
    • 2001
  • Selection of oocyte cryopreservation method is a prerequisite factor for developing an effective bank system. Compared with slow freezing method, the vitrification has various advantages such as avoiding intracellular ice crustal formation. In our previous, we attempted to employ a vitrification method using ethylene glycol and an electron microscope grid for cryopreservation of mouse oocytes. However, A high incidence of spindle and chromosome abnormalities was detected in thawed oocytes after vitrification. We examined whether the addition of a cystoskeleton stabilizer Taxol $^{TM}$, to the vitrification solution could promote the post-thawed survival and subsequent development of stored oocytes. More oocytes developed to the 4-cell (44.7% vs. 69.7%), 8-cell (31.8% vs. 64.2%), morula (24.7% vs. 54.3%), and blastocyst (20.3% vs. 49.2%) stages after the addition of Taxol$^{TM}$ to the cryoprotectant than after no addition. 21 and 26 mouse pups were born after transfer of blastocyst derived from oocytes vitrified without and with Taxol. The addition of Taxol to vitrification solution greatly promoted post-thaw preimplantation development of ICR morose oocytes.tes.

  • PDF

WinDS$3000^{TM}$ 시스템의 블레이드 개발 및 시험 (Blade Development and Test of WinDS$3000^{TM}$ System)

  • 이상일;이경우;주완돈;이기학;박종포
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.448-448
    • /
    • 2009
  • A new blade has been developed to apply to Doosan 3MW offshore wind turbine named as WinDS3000TM. The 3MW blade has been designed by the concept of slim external shape and optimized structure. High-performance glass fiber reinforced epoxy composites were used as the main material of the blade. The blade was manufactured using vacuum infusion process in order to increase the fiber volume fraction and to reduce micro-porosities. The blade has successfully passed the full-scale blade static test for certification. During the test, micro-failure signal and strain change of the blade were measured using acoustic emission sensors and strain gages. The blade has robust structure and weighs lighter compared to conventional blade since the new blade was designed by optimization process. The 3MW blade will be commercially applied to WinDS$3000^{TM}$ in 2010.

  • PDF

Investigation of Dietary Lysophospholipid (LipidolTM) to Improve Nutrients Availability of Diet with In Vitro Rumen Microbial Fermentation Test

  • Cho, Sangbuem;Kim, Dong Hyun;Hwang, Il Hwan;Choi, Nag-Jin
    • 한국초지조사료학회지
    • /
    • 제33권3호
    • /
    • pp.206-212
    • /
    • 2013
  • This study was conducted to investigate the effect of biological membrane transfer modifier, lysophospholipd (LPLs) on the parameters from in vitro rumen simulated fermentation. Commercially available LPLs product (Lipidol$^{TM}$) was supplemented into experimental diets which consisted of orchard grass and concentrate diet (60:40) in different levels (0.1%, 0.3% and 0.5%). Then in vitro rumen simulated fermentation was performed. Although, a declining trend of pH was found in treatments, all pH values were detected in a range relevant to normal rumen fermentation. Gas production, ammonia nitrogen and total VFA production were greatly influenced by the supplementation of LPLs. All parameters were increased along with increased levels of LPLs in diet. As a result, 0.1% of Lipidol$^{TM}$ is recommended based on the determined in vitro rumen fermentative parameters in this study.

난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study (Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition)

  • 이성재;신충훈;최소영;이동형;유순미;송흥권;윤인하
    • 대한방사선치료학회지
    • /
    • 제34권
    • /
    • pp.73-82
    • /
    • 2022
  • 목 적: 본 연구는 난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 HalcyonTM Fast kV CBCT를 사용하였을 때 난소에 미치는 흡수선량과 영상의 품질을 분석하여 유용성을 평가하고자 한다. 대상 및 방법: 인체모형 팬텀(Alderson Rando Phantom, USA)의 전산화단층촬영 영상에 측정에 필요한 자궁경부와 난소의 윤곽묘사(contouring)를 하였고, 해당 장기 단면에 광자극발광선량계(Optically Stimulated Luminescence Dosimeter, OSLD, InLight system, Landauer, USA)를 각각 3개씩 부착하였다. TruebeamTM의 Pelvis mode(이하 TP)와 HalcyonTM의 Pelvis mode(이하 HP) 그리고 HalcyonTM의 Pelvis Fast mode(이하 HPF)에서 자궁경부와 난소에 들어가는 흡수선량을 측정하기 위해 촬영 범위를 17.5 cm와 12.5 cm로 촬영 범위를 축소한 영상을 촬영하였다. 총 10회의 누적선량을 합산하였고, 자궁경부암 치료 횟수인 23회의 값으로 치환하여 비교하였다. 또한 영상 장비 간의 CBCT 영상 품질을 비교하기 위해 Catphan 504 팬텀(The Phantom Laboratory, USA)을 이용하여 균일도(Uniformity), 저 대조도 가시(Low contrast visibility, LCV), 공간분해능(Spatial resolution), 기하학적 왜곡(Geometric Distortion)을 비교 분석하였다. 각각 3회 반복 측정하여 Doselab (Versions: 6.8, Mobius Medical Systems) 프로그램으로 분석 후 평균값을 구하였다. 결 과: CBCT에 의한 흡수선량을 OSLD로 측정한 결과 동일한 조건일 시 TP와 HP는 유의미한 결과를 얻지 못하였다. 가장 큰 감소 값을 보인 모드는 TP 대비 HPF였다. HPF는 17.5 cm의 촬영 범위에서 흡수선량이 TP보다 자궁경부가 약 39.82%, 난소에서 약 19.8% 감소 하였고, 12.5 cm 으로 촬영 범위를 축소할 경우 자궁경부는 34.2%, 난소 50.5%로 감소 시킬 수 있었다. 또한 위 실험에서 사용된 영상의 품질을 평가한 결과 Geometric Distortion 1mm 이내(SBRT 기준), Uniformity HU, LCV 2.0% 이내 Spatial Resolution 3 lp/mm 이상으로 장비사의 기준치를 준수하였다. 결 론: 본 실혐 결과에 따라 난소전위술을 시행한 가임기 여성의 방사선치료 시 CBCT로 인한 피폭선량을 낮추기 위해서는 TruebeamTM 보다 다양한 조건을 선택 할 수 있는 HalcyonTM이 유용할 것으로 평가 되며, 특히 낮은 mAs로도 영상의 품질을 유지하는 HalcyonTM의 Fast kV CBCT를 권장한다. 다만 다른 치료 장비에서도 난소전위를 시행한 환자는 촬영 범위를 조정하는 것으로 저선량에 대한 추가적인 피폭 감소시킬 수 있을 것으로 사료된다.

TM과 레이더를 이용한 유역평균강수량 차이와 유역특성 및 강우형태와의 상관성 (The analysis of differences of mean basin precipitation between TM and radar using correlation with basin characteristics and rainfall patterns)

  • 박재현;성장현;조요한;허준행
    • 한국수자원학회논문집
    • /
    • 제53권7호
    • /
    • pp.469-480
    • /
    • 2020
  • 본 연구는 레이더와 TM간 유역평균강수량 측정의 차이를 2018년 발생한 상당 규모의 호우시 한강과 낙동강의 51개 표준유역을 대상으로 분석하였다. 그 결과 레이더와 TM간의 유역평균강수량 값이 누적강수량은 -65.05~26.09%, 10분최대 강수량은 -82.00~3.80%의 차이가 발생하였다. 이러한 차이를 유역의 특성인 유역면적, 유역평균고도, 유역형상계수 등과 비교하였으나 뚜렷한 상관성을 찾기가 어려웠으며, 지점강수량도 유역평균강수량과 비슷한 경향을 보이는 것을 확인하였다. 따라서 강우형태와 같은 기상학적 조건과의 상관성을 확인하기 위해 고도별 레이더 반사도 값을 분석하였으며 이를 통해 레이더와 TM간 유역평균강수량 측정값의 차이는 유역특성과 같은 지형적 조건 보다는 기상학적 조건과 더 상관성이 있는 것을 확인할 수 있었다.

역/촉감 햅틱 상호작용을 위한 "K-$Touch^{TM}$" API 개발 - 햅틱(Haptic) 개발자 및 응용분야를 위한 소프트웨어 인터페이스 - (Development of K-$Touch^{TM}$ API for kinesthetic/tactile haptic interaction)

  • 이범찬;김종필;류제하
    • 한국HCI학회논문지
    • /
    • 제1권2호
    • /
    • pp.1-8
    • /
    • 2006
  • 본 논문은 새로운 햅틱 API인 "K-$Touch^{TM}$"의 개발에 관한 것으로 역/촉감 상호작용이 가능하도록 설계된 소프트웨어 아키텍처이다. K-$Touch^{TM}$는 햅틱 세부 기술을 잘 알지 못해도 응용분야를 쉽게 제작할 수 있도록 구성되어 있으며, 햅틱 기술을 개발하는 개발자가 쉽게 개발 내용을 추가할 수 있도록 구성되어 있다. 그래픽 하드웨어 기반의 핵심 역감 알고리즘을 기반으로 개발된 K-$Touch^{TM}$ API는 가상 환경을 구성하는 다양한 데이터 형식(2D, 2.5D depth(height field), 3D polygon 및 볼륨 데이터)에 대한 햅틱 상호작용을 가능하게 하고, 새로운 햅틱 알고리즘 및 장치 개발에 필요한 소프트웨어 확장성을 제공함과 동시에 사용자가 쉽고 빠르게 햅틱 응용분야를 개발할 수 있도록 설계되었다. 아울러 햅틱 감각의 중요 요소인 역감 및 촉감 상호작용을 위해 기존의 햅틱 SDK 및 API와 달리 역/촉감을 동시에 렌더링할 수 있는 알고리즘이 개발되었다. 본 논문에서 제안하는 새로운 햅틱 API의 효용성을 검증하기 위해 다양한 응용분야의 예를 구현하였다. 새로운 햅틱 API인 K-Touch는 사용자 및 연구자에게 보다 효율적으로 햅틱 연구를 진행 할 수 있도록 도움을 주는 툴킷(Toolkit)으로써 중요한 역할을 할 것으로 기대된다.

  • PDF

카르바마제핀 서방형 제제간의 생물학적 동등성 비교 (The Bioequivalence of Two Carbamazepine Controlled Release Formulations)

  • 김민정;이현정;류윤미;신완균;박성호
    • 한국임상약학회지
    • /
    • 제6권2호
    • /
    • pp.19-23
    • /
    • 1996
  • Carbamazepine is an anticonvulsant drug that has been shown to be as effective as phenytoin or phenobarbital in treatment of grand mal and complex partial seizures and is also approved as the drug of choice for treatment of the pain associated with trigerminal neuralgia. And the therapeutic or toxic effects of carbamazepine are better related to plasma concentration than to dosage, which can be attributed to interindividual variability in the pharmacokinetics. A slow rate of carbamazepine dissolution in the gastrointestinal tract is believed to be the cause of its relatively slow and erratic rate of absorption. For these reasons pharmacokinetic evaluation of newly formulated carbamazepine is neccessary. In this study, the bioequivalence in carbamazepine between the $TegretoI^{TM}$ CR tablet (Geigy Co.) and $Carmazepine^{TM}$ CR tablet (Myung In Co.) was evaluated. 12 normal volunteers (age $21\~27$ years old) was divided into two groups, and a randomized cross-over study was employed. The pharmacokinetic parameters ($C_{max},\;T_{max}$ and AUC) obtained of oral administration of each formulatim of carbamazepine 400 mg were evaluated and ANOVA was utilized for the statistical analysis of parameters. $C_{max}\;is\;8.26{\pm}3.1{\mu}g/ml\;(C.V.\;37.3\%)\;in\;TegretoI^{TM}\;and\;9.39\{pm}2.9{\mu}g/ml\;(C.V.\;30.5\%)$ in $Carmazepine^{TM},\;T_{max}\;is\;28.0{\pm}5.9\;hrs(C.V.\;21.1\%)$ in $Tegretol^{TM}\;and\;24.0{\pm}7.2\;hrs(C.V.\;30.2\%)$ in $Carmazepine^{TM}$ and AUC is $786.4{\pm}360.5{\mu}g{\cdot}hr/ml\;(C.V.\;45.8\%)$ in $TegretoI^{TM}\;and\;792.8{\pm}228.6{\mu}g{\cdot}hr/ml\;(C.V.\;28.8\%)$ in $Carmazepine^{TM}$, respectively. As the result of the data, two formulations are bioequvalent, and the lower C.V. of $Carmazepine^{TM}$ in every individual can be merit.

  • PDF

천연 및 가교 키토산에 의한 희토류 원소의 흡착과 회수에 관한 연구 (A Study on the Adsorption of Rare Earth Elememts by Raw and Crosslinked Chitosan)

  • 조성일;최종문;김영상;이석근
    • 분석과학
    • /
    • 제17권2호
    • /
    • pp.108-116
    • /
    • 2004
  • 본 연구에서는 천연 키토산과 glutaraldehyde을 이용하여 가교한 가교 키토산을 사용하여 희토류 금속과의 흡착특성을 조사하였다. 최대 흡착량을 나타내는 최적 pH 영역은 $Nd^{3+}$$Tm^{3+}$ 금속이온의 경우, 천연 및 가교 키토산에 대해 4.5~5.5 영역이었으며, $La^{3+}$$Ce^{3+}$ 금속이온의 경우, 가교 키토산은 pH 4. 0~5.5 영역, 천연 키토산은 pH 2.0에서 최대 흡착량을 보였다. 단일상 (pH 4.0)에서 희토류 금속의 최대 흡착량은 $Er^{3+}$ > $Gd^{3+}$ > $Yb^{3+}$ > $Nd^{3+}$ > $Lu^{3+}$ > $Eu^{3+}$ > $Tm^{3+}$ > $Ho^{3+}$ > $Dy^{3+}$ > $La^{3+}$ > $Ce^{3+}$ > $Y^{3+}$ > $Pr^{3+}$ 같은 순서로, 혼합상에서는 $Lu^{3+}$ > $Yb^{3+}$ > $Tm^{3+}$ > $Dy^{3+}$ > $Ho^{3+}$ > $Er^{3+}$ > $Eu^{3+}$ > $Gd^{3+}$ > $Nd^{3+}$ > $Y^{3+}$ > $La^{3+}=Ce^{3+}=Pr^{3+}$의 순서로 경쟁적 흡착반응을 나타내었다. 혼합상에서 희토류 금속의 경쟁반응은 원자번호가 증가할수록, 그리고 이온반지름이 작을수록 높은 흡착량을 나타내었다. 최대 흡착량에 도달하는데 걸리는 흡착평형시간은 이전 금속이온과의 연구에서와 상이하게 5시간 이상 소요되었다. 키토산에 대한 희토류 금속이온의 회수율은 $Nd^{3+}$ 이온의 경우, 83~95%이고, $Tm^{3+}$ 이온의 경우, 90~106%을 나타내었다.