• 제목/요약/키워드: Tl-201

검색결과 90건 처리시간 0.04초

악성 흉선종에서 관찰된 Tc-99m MIBI와 Tl-201의 섭취 (Tc-99m MIBI and Tl-201 Uptake in a Thymic Carcinoma)

  • 현인영
    • 대한핵의학회지
    • /
    • 제37권4호
    • /
    • pp.260-261
    • /
    • 2003
  • Tc-99m methoxyisobutylisonitrile (MIBI) and Tl-201/technetium subtraction scintigraphy have been used for localization of abnormal parathyroid gland. The uptake mechanism of tracers has been postulated to be increased cellular density and vascularity, or dependent on the presence of mitochondria-rich cells. However, the uptake of these tracers was not specific for abnormal parathyroid gland. The author report a case of thymic carcinoma that would have been mistaken for carcinoma of parathyroid because of Tc-99m MIBI and Tl-201 uptake.

폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석 (Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography)

  • 전권수;서용섭;양승대;안순혁;김상욱;최강혁;이동훈;임상무;유국현
    • 대한핵의학회지
    • /
    • 제34권4호
    • /
    • pp.336-343
    • /
    • 2000
  • 목적: $[^{201}Tl]$TICI주사액의 제조과정에서 안정동위원소인 $^{201}Tl$ 및 Cu, Pb의 중금속을 함유할 가능성이 있어 이러한 이물질을 확인하기 위한 방법으로 방사성 물질의 대기오염을 일으키지 않는 폴라로그래피의 분석 조건을 설정하고자 하였다. 대상 및 방법: 원자력병원에서 생산하고 있는 $[^{201}Tl]$-TlCl 주사액에 포함될 수 있는 중금속을 대상으로 하였다. 극미량의 중금속을 측정하기 위한 방법으로 BAS-50W 폴라로그래피를 이용하였고, 여기에 사용된 3 전극계는 작업전극인 DME, 기준전극인 Ag/AgCl 그리고 보조전극인 백금선을 이용하였다. 신속하고 재현성있는 분석을 위한 조건으로 기기의 분석 모드, 각 모드에 적합한 전극, 지지전해질, 석출시간 등의 치적 조건을 설정하였다. 결과: 폴라로그래피의 모드는 OSWSV 방법이 재현성과 감도면에서 가장 우수하였고, 작업전극은 DME와 Au 전극을 비교 실험한 결과 재현성 면에서 DME가 보다 좋은 결과를 보였다. 지지전해질은 염기성인 0.50 M KOH 용액, 산성인 1.0 M $HNO_3$, 용액, 중 성인 pH 7 phosphate 완충용액을 비교 실험하여 pH 7 phosphate 완충용액이 $Tl^+$$Cu^{2+}$를 분석하는데 가장 적합함을 확인하였다. 이를 바탕으로 중금속을 측정한 결과 $Tl^+$은 -450 mV, $Cu^{2+}$는 -50 mV에서 각각의 피크가 나타났고, 석출시간을 45초로 하였을 때 $Tl^+$의 경우 y=2.05E-$9{\chi}$+5.66E-9이고 $Cu^{2+}$의 경우는 y=1.23E-$8{\chi}$+1.23E-6의 선형 관계식을 얻었다. 결론: 이 방법에 의한 Tl과 Cu의 검출한계는 약 0.05 ppm이다. 이 방법을 현재 원자력병원에서 생산하고 있는 $[^{201}Tl]$TICl 주사액의 정도관리에 도입하여 중금속을 측정한 결과 약전에서 규정하고 있는 2 ppm 미만임을 확인하였고, 그 결과는 재현성, 정확도, 감도 및 간편성에서 모두 만족할 수 있었다. 이 방법은 $[^{201}Tl]$TlCl 주사액 뿐만 아니라 $^{67}Ga$ 주사액 및 기타 방사성의약품과 중금속 분석에도 응용할 수 있다.

  • PDF

심근 게이트 SPECT로 측정한 좌심실 용적과 구혈률의 정상 값 확립: Tl-201과 Tc-99m MIBI 게이트 SPECT의 비교 (Normal Limits of Left Ventricular Volumes and Ejection Fraction Measured by Gated Myocardial Perfusion SPECT: Comparison of Tc-99m MIBI and Tl-201)

  • 현인영;서정기;권준;박금수;최원식;이우형
    • 대한핵의학회지
    • /
    • 제37권3호
    • /
    • pp.147-152
    • /
    • 2003
  • 목적: 정상 군에서 휴식 Tl-201/약제 부하 Tc-99m MIBI 심근 게이트 SPECT를 시행하여 정상 좌심실 용적과 구혈률의 기준 값을 만들고자 하였다. 대상 및 방법: 총 70명을 대상으로 휴식 Tl-201/약제 부하 Tc-99m MIBI 심근 게이트 SrECT를 촬영하였다. 게이트 관류 SPECT를 재구성하고 Cedars 소프트웨어로 좌심실 용적과 구혈률을 측정하였다. 성별과 사용한 동위원소에 따른 좌심실의 구혈률과 용적의 차이점을 평가하고 기준 값을 확립하였다. 결과: 사용한 동치원소에 따라 좌심실 구혈률은 유의하게 다르지 않았다(Tl-201: $63%{\pm}8%$ vs Tc-99m MIBI: $62%{\pm}7%$). 그러나 사용한 동위원소에 따른 좌심실 용적의 비교시 Tc-99m MIBI ($EDV;\;82{\pm}25mL,\;ESV;\;32{\pm}15mL$)보다 Tl-201 ($EDV;\;74{\pm}23mL,\;ESV;\;28{\pm}14mL$)의 좌심실 용적이 유의하게 작았다(p<0.05). 여자의 좌심실 용적은 남자의 값보다 유의하게 작았고(p<0.05) 이는 두 동위원소 모두에서 관찰되었다. 그러나 Tl-201을 이용하였을 때만 여자의 좌심실 구혈률($65%{\pm}7%$)이 남자($60%{\pm}8%$)보다 유의하게 높았고(p<0.05), Tc-99m MIBI의 경우에는 성별에 따른 좌심실 구혈률의 유의한 차이는 없었다. 결론: 이 연구에서 우리는 게이트 SPECT로 측정한 정상 좌심실 용적과 구혈률의 기준 값을 확립하였다. 그리고 이 기준 값은 향 후 연구되는 게이트 SPECT 연구의 기본 자료로서 유의하게 쓰일 수 있을 것으로 생각된다.

심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교 (The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT)

  • 송재혁;김경식;이동훈;김성환;박장원
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.87-92
    • /
    • 2015
  • SPECT에서 Uniformity는 균일한 방사능을 갖는 선원에 대하여 균일한 영상을 제공하는 능력이다. 영상에서 다양한 이유로 불균일이 발생하게 되고, 불균일은 artifacts를 발생시켜 임상적으로 진단하는데 영향을 줄 수 있다. Uniformity correction map은 검사에 사용되는 방사성 동위원소를 이용하여 영상에서 Uniformity의 변동폭을 최소화 시켜주는 역할을 한다. 본원에서 시행되고 있는 $^{201}Tl$을 이용한 심근 SPECT에서는 $^{99m}Tc$으로 기본 설정되어 있는 Uniformity correction map을 사용하고 있으며, 이에 따라 본 연구에서는 $^{201}Tl$$^{99m}Tc$ 두 가지 핵종으로 Uniformity correction map을 각각 설정하였을 때 영상의 질에 차이가 있는지 비교 분석하고, 영상의 질을 최적화 할 수 있는 방법에 대하여 모색해 보고자 한다. 장비는 GE Ventri Gamma camera, Flood phantom, Jaszczak ECT phantom을 이용하였다. 실험에 앞서 Collimator를 제거한 상태에서 Detector 표면 중심으로부터 2.5 m 떨어진 지점에 1 cc 주사기에 $^{99m}Tc$ 25.9 Mbq, $^{201}Tl$ 14.8 Mbq의 방사성 동위원소를 주입한 point source를 이용하여 장비사에서 권고하는 $6{\times}10^7count$$^{99m}Tc$$^{201}Tl$ 각각의 방사성 동위원소로 Uniformity Mapping을 실시하였다. Flood phantom에는 $^{201}Tl$ 21.3 kBq/mL, Jaszczak ECT phantom에는 $^{201}Tl$ 33.4 kBq/mL를 주입하여 phantom을 제작하였다. Flood Phantom으로 획득된 데이터는 Xeleris ver 2.05 프로그램을 이용하여 Integral uniformity, Differential uniformity을 두 가지 항목에 대하여 분석하였다. Jaszczak ECT Phantom으로 획득된 데이터를 본원에서 자체 개발한 Interactive Data Language 프로그램에 입력하여 Integral uniformity, Contrast, Coefficient of variation, Spatial Resolution을 4가지 항목에 대하여 분석하였다. Flood phantom test 에서는 $^{99m}Tc$에서의 Flood I.U값은 3.6%, Flood D.U값은 3.0%으로 나타났고, $^{201}Tl$ Flood I.U값은 3.8%, Flood D.U값은 2.1%으로 나타났다. 이를 통해 $^{201}Tl$으로 Uniformity correction map을 설정하였을 때, Flood I.U값은 감소하였으나 Flood D.U은 향상되어 Flood 영상에서는 크게 영상의 질이 개선되었는지는 알 수 없었다. 반면 Jaszczak ECT Phantom test에서는 $^{99m}Tc$에서의 SPECT I.U값은 13.99%, Coefficient of variation값은 4.89%, contrast값은 0.69, $^{201}Tl$에서의 SPECT I.U값은 11.37%, Coefficient of variation값은 4.79%, contrast값은 0.78로 나타났으며, 육안 분석을 실시한 Spatial Resolution 항목에서는 육안으로 큰 차이를 보이지 않았다. 이를 통해 $^{201}Tl$으로 Uniformity correction map을 설정하였을 때, Spatial Resolution 을 제외한 SPECT I.U, Coefficient of variation, Contrast 세 항목에서 각각 18%, 2%, 13%의 향상된 수치를 보였다는 점에서 영상의 질이 개선되었음을 알 수 있었다. Uniformity correction map이 영상의 질을 크게 좌우할 수 없으나, 개선의 효과를 가져다 준다는 점에서 임상적으로 진단에 영향을 주는지 또한 다른 검사에서 또 다른 방사성 동위원소로 Uniformity correction map을 설정했을 경우 영상의 질을 개선시킬 수 있는지에 관하여 추가적인 연구가 필요할 것으로 사료된다.

  • PDF

폐암 수술 후 흉벽의 종양 재발 검출에 있어 Tl-201 폐 SPECT의 유용성 (Thallium-201 SPECT in the Evaluation of Postoperative Tumor Recurrence on the Chest Wall in Lung Cancer)

  • 유영훈;김형중;안철민;김세규;백효채;이두연;정경영;윤미진;박상준;문성욱;김상진;이종두
    • Tuberculosis and Respiratory Diseases
    • /
    • 제53권5호
    • /
    • pp.542-549
    • /
    • 2002
  • Background : 본 연구의 목적은 폐암 수술 후 흉벽의 종양 재발 검출에 있어 Tl-201 폐 SPECT의 유용성을 평가해보고자 하였다. Methods : 총 28명의 환자를 대상으로 하였고 이중 14명의 수술 후 흉벽에의 폐암의 재발이 추적 CT 검사에서 의심이 되었던 환자와 10명의 방사선학적, 이학적소견과 흉수의 세포검사모두에서 양성으로 판명된 수술 후 흉막 삼출을 보이는 환자군과 4명의 만성 결핵성 농흉 환자군을 대조군으로 포함하였다. 모든 환자군에서 111 MBq의 Tl-201을 정맥 주사 후 30분과 4시간후에 전신 평면 영상과 흉곽에 대한 SPECT를 시행하였다. 종양의 Tl-201섭취는 2명의 판독자에 의하여 다음의 4단계로 나누어 평가하였다; no uptake:0, similar to contralateral lung:1, higher than contralateral lung but less than heart:2 and similar to heart:3. Results : 수술 후 흉벽에의 폐암의 재발이 추적 CT 검사에서 의심이 되었던 환자 14명 중 13명에서 Grade 3또는 2의 강하게 증가된 Tl-201의 섭취를 보였다. 그리고 14명중 2명에서는 CT에서 관찰되지 않았던 다른 부위의 종양 재발을 확인 할 수 있었다. 반면에, 양성 수술 후 흉막 삼출군에서는 섭취가 없거나(8/10) 또는 허탈된 폐에 미미한 (grade 1) Tl-201의 섭취만을 보였다. 만성 결핵성 농흉군에서는 비교적 균일하게 경계를 보이는 미약한 정도의 (grade 1 or 2) Tl-201의 섭취를 보였다. Conclusion : Tl-201 폐 SPECT는 폐암 수술 후 흉벽의 종양 재발 검출에 있어 CT에서 제공하는 형태학적인 정보이외의 종양 재발에 관한 기능적 정보를 더 제공하며, PET이 없는 기관에서 사용 가능한 유용한 방법이 될 수 있을 것으로 생각된다.

급성 심근경색 후 휴식 / 24시간 지연 $^{201}Tl$ 심근 SPECT 상 역재분포를 보인 경색심근에서 관찰된 $^{18}F-FDG$ 섭취 결손 (Defect of $^{18}F-FDG$ Uptake Observed in Infarcted Myocardium Showing Reverse Redistribution on Rest / 24-Hour Delayed $^{201}Tl$ Myocardial SPEG after Acute Myocardial Infarction)

  • 이호영;팽진철;오소원;김지영;정우영
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권6호
    • /
    • pp.478-481
    • /
    • 2008
  • Reverse redistribution is frequently observed after revascularization in acute myocardial infarction, and usually regarded as a predictor of viable myocardium on stress/rest and 2- to 4-hour redistribution $^{201}Tl$ SPECT. However, there is not enough report of reverse redistribution in case of 24-hour delayed SPECT, which is commonly used for viability assessment. In this report, a case of reverse redistribution on rest and 24-hour delayed $^{201}Tl$ SPECT is reported with use of automatic segmental quantitative analysis. The myocardium of reverse redistribution was dysfunctional on gated SPECT, and diagnosed as non-viable on $^{18}F-FDG$ PET.

니트로글리세린 투여 Tc-99m-MIBI 정량 게이트 심근SPECT를 이용한 관상동맥우회로술 후 심근 기능 회복 예측 (Nitroglycerin-Challenged Tc-99m MIBI Quantitative Gated SPECT to Predict Functional Recovery After Coronary Artery Bypass Surgery)

  • 이동수;김유경;천기정;팽진철;이명묵;김기봉;정준기;이명철
    • 대한핵의학회지
    • /
    • 제37권5호
    • /
    • pp.278-287
    • /
    • 2003
  • 목적: 생존심근 진단에 있어 니트로글리세린 투여 Tc-99m-MIBI 게이트 심근SPECT의 진단성능을 휴식/지연재분포 Tl-201 심근SPECT와 비교하였다. 대상 및 방법: 22명의 관상동맥질환자에서 Tl-201 휴식/디피리다몰 부하 Tc-99m-MIBI 게이트 지연재분포 Tl-201 심근SPECT를 시행하였다. 이 때 게이트SPECT 시행 후 니트로글리세린 0.6 mg을 설하투여하고 연이어 그 자리에서 게이트SPECT를 1회 더 반복 시행하였다. 환자들에게 관상동맥우회로술을 시행하고 3개월 후 게이트 심근SPECT를 추적검사로 시행하였다. 20 분절 모델을 이용하여 각 분절에서 휴식, 지연재분포, 기저상태와 니트로글리세린투여 후의 심벽운동 및 수축기비후화 등을 정량하였다. 정량화된 생존심근 예측지표들 중, (1) 휴식기 Tl-201 섭취, (2) Tl-201 지연재분포, (3) 기저상태의 수축기비후화, (4) 니트로글리세린 투여 후의 수축 기비후화, 네 가지의 예측성능을 평가하고 비교하였다. 결과: 총 100개의 분절이 분석에 포함되었으며, 이 중 66개(66%)의 분절이 재관류 후 기능 회복을 보였다. 최적 기준점인 50%를 기준으로 하였을 때, ROC 곡선 분석에서 휴식기 Tl-201 섭취와 Tl-201 지연재분포의 민감도, 특이도는 각각 79%와 44%, 그리고 82%와 44%였다. 또한 15%를 기준으로 하여, 기저상태 수축기비후화와 니트로글리세린 투여 후 수축기비후화의 민감도, 특이도는, 각각 49%, 50%와 64%, 65%였다. ROC 곡선의 AUC는 니트로 글리세린 투여 후 수축기비후화가 기저시 수축기비후화에 비하여 유의하게 높았다(p=0.004). 결론: 니트로글리세린 투여 Tc-99m-MIBI 정량적 게이트 심근SPECT는 기능이상 심근에서 기능 회복을 예측하는데 유용한 검사이다.

Tc-99m pertechnetate/Tl-201 감영 신티그라피에서 부갑상선 선종으로 오인된 흉선종 1예 (A Case of Thymoma Misdiagnosed as Parathyroid Adenoma on Tc-99m pertechnetate/Tl-201 Subtraction Scintigraphy)

  • 정용안;유이령;김성훈;정수교;왕영필;정지한;이교영;김병기
    • 대한핵의학회지
    • /
    • 제35권4호
    • /
    • pp.274-279
    • /
    • 2001
  • A large superior mediastinal mass was found incidentally by ultrasonography in a 60-year-old man. There was an abnormal accumulation of Tl-201 in the lower pole of left thyroid gland, extending into left superior mediastinum on Tc-99m pertechnetate/Tl-201 subtraction scan. Laboratory findings relating thyroid and parathyroid were all within normal range. We considered the mass as a non-functioning parathyroid adenoma tentatively. However, subsequent surgery and pathologic examination revealed the mass to be a benign mixed thymoma. We report a case of patient with thymoma showing unusual Tc-99m pertechnetate/Tl-201 subtraction imaging and laboratory findings, and suggest to consider the possibility of other mediastinal tumors rather than parathyroid adenoma.

  • PDF

악성 골 및 연부조직 종양에서 Tl-201 SCAN의 진단적 효능 - Tc-99m-MIBI 및 Tc-99m-MDP scan과의 비교 - (Thallium-201 Scan in Bone and Softtissue Sarcoma - Comparison with Tc-99m-MIBI and Tc-99m-MDP Scan -)

  • 신덕섭;조인호;안종철;안면환;이상호
    • 대한골관절종양학회지
    • /
    • 제2권1호
    • /
    • pp.1-7
    • /
    • 1996
  • PURPOSE : The purpose of this study is to know the ability of detecting malignant tumor tissue by Tl-201 scan, and to compare with that of Tc-99m-MIBI and Tc-99m-MDP scan. MATERIAL AND METHODS : Between February 1994 and December 1995,38 unselected patients with various bone pathologies were studied prospectively. Eighteen had malignant bone and soft tissue pathologies, while twenty had benign. All patients were studied with Tl-201, Tc-99mMIBI and Tc-99m-MDP scan prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator was used for scanning. To avoid the interaction of isotope, the early(30min.) and delayed phase(3hrs.) of Tl-20l scan was performed first and Tc-99m-MIBI scan was performed after 30 minutes, and then Tc-99m-MDP scan 48 hours later. The scan images were visually evaluated by a blinded nuclear medicine physician. We could find true positive, true negative, false positive and false negative by the comparison of results with those of biopsy. We calculated positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%) of each scan. RESULT : The results of each scan were 85.7, 100, 100, 85, 92.1% in Tl-201, 81, 94.1, 94.4, 80, 86.8% in Tc-99m-MIBI and 50, 66.7, 88.9, 20, 52.6% in Tc-99m-MDP scan. As a conclusion, Tl-201 scan was the most specific and accurate method for detecting malignant tumor tissue. Tc-99m-MIBI scan was also good for malignant tumor searching. CONCLUSION : With our results, we can use Tl-201 scan to differentiate benign from malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

급성심근경색증의 일차적 관동맥성형술 후 조기 Tl-201 재분포영상을 이용한 구조심근 예측 (Prediction of Salvaged Myocardium in Patients with Acute Myocardial Infarction after Primary Percutaneous Coronary Angioplasty using early Thallium-201 Redistribution Myocardial Perfusion Imaging)

  • 최준영;양유정;최승진;여정석;박성욱;송재관;문대혁
    • 대한핵의학회지
    • /
    • 제37권4호
    • /
    • pp.219-228
    • /
    • 2003
  • 목적: 심근경색증 후 재관류술에 의해 구조된 심근의 범위는 중요한 예후 인자중의 하나이다. 급성심근경색증의 일차적 관동맥성형술 후 조기 Tl-201 재분포영상이 구조심근과 심근벽운동 호전을 예측할 수 있는지 알아보았다. 대상 및 방법: 흉통 발생 $5.2{\pm}2.8$시간에 급성심근경색증으로 일차적 관동맥성형술을 시행한 36명을 대상으로 관동맥성형술 후 $5.8{\pm}2.1$일에 디피리다몰 부하 -4 시간 재분포 Tl-201 SPECT 영상을 얻었다. Tl-201 재분포 영상은 좌심실을 16분절로 나누고, 각 분절의 섭취를 5등급으로 평가하였다. 심초음파는 내원 당시, 경색 후 7일, 30일, 7개월에 시행하였고, 구조심근 분절은 내원 당시 심초음파상 벽 운동 이상이 있으면서 30일 또는 7개월 심초음파에서 벽 운동이 호전된 분절로 정의하였다. 결과: 내원 당시 212분절에서 벽운동 이상을 보였다(저운동 41분절, 무운동 171분절). 이중 1개월에는 78분절(36.8%)에서, 7개월에는 97분절(45.8%)에서 벽 운동이 호전되어 구조심근으로 판정하였다. 구조심근을 찾는 Tl-201 재분포 영상의 수신자판 단특성곡선면적은 1개월에 대해서는 $0.79{\pm}0.03$, 7개월에 대해서는 $0.83{\pm}0.03$이었다. Tl-201 섭취 40%를 경계로 정할 때 재분포 영상의 구조심근을 찾는 예민도, 특이도는 1개월에서는 84.6%(66/68), 55.2%(74/134), 7개월에서는 87.6%(85/97), 64.3%(74/115)였다. 재분포영상에서 Tl-201의 섭취정도와 벽 운동의 호전될 확률은 서로 비례하는 경향을 나타내었다. 결론: 급성심근경색증의 일차적 관동맥성형술 후 10일 이내에 시행한 조기 Tl-201 재분포영상은 구조심근과 심근벽운동 호전 예측 판정에 높은 예민도로 유용하게 사용될 수 있는 검사이다.EX>$100{\mu}M$)는 각각 11.9배와 6.8배, K562(Adr) 세포에서($50{\mu}M$)는 각각 14.3배와 8배, K562(Vcr) 세포에서($10{\mu}M$)는 각각 7배와 5.7배 증가하였다. Cyclosporin A에 의한 MIBI와 tetrofosmin의 섭취율(30분)을 기저치(30분)와 비교해 본 결과 HCT15/CL02세포에서($50{\mu}M$)는 각각 10배와 2.4배, K562(Adr)세포에서($50{\mu}M$)는 각각 44배와 13배, K562(Vcr)세포에서($10{\mu}M$)는 각각 18.8배와 11.8배 증가하여, MIBI의 섭취율이 tetrofosmin보다 1.2배에서 4배정도 높게 나타났다. 결론: 이러한 결과로 보아 MIBI와 tetrofosmin은 다약제내성의 발현을 평가할 수 있는 방사성의약품으로 판단되며, 다약제내성 극복제의 효능평가에는 MIBI가 tetrofosmin보다 더 우수할 것으로 사료되나, 세포추에 따른 차이가 있을 수 있으므로 보다 많은 세포주에서의 추가적인 연구가 필요할 것이다.여 후 구한 MPD는 평균 $13.3{\pm}1.9GBq\;(9.7{\sim}16GBq)$ 이였고, 치료용량 방사성옥소 투여 후 구한 MPD는 평균 $13.8{\pm}2.1GBq(10.4{\sim}16.3GBq)$로 유의한 차이가 얻었으며 (p=0.20), 두 수치간에는 유의한 상관 관계가 있었다(r=0.8, p<0.0001). 7명의 환자에서 말초혈액림프구 중기염색체 분석법으로 MPD를 측정하였는데 혈액의 피폭선량은 $1.78{\pm}0.03Gy$였으며, 같은 환자에서 혈중 방사능소실곡선으로부터 구한 피폭선량은 $1.54{\pm}0.03Gy$로 유의하게 낮았으나 (p=0.01), 두