• 제목/요약/키워드: Titanium mesh

검색결과 92건 처리시간 0.021초

장골의 복합유리피판 이식 후 두 개의 타이타늄 금속판을 이용한 공여부의 심미적 재건 (ESTHETIC RECONSTRUCTION OF ILIAC CREST DONOR DEFECT WITH TWO TITANIUM PLATES AFTER HARVESTING A DCIA COMPOSITE FREE FLAP)

  • 김성민;인연수;김지혁;박영욱
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권6호
    • /
    • pp.586-589
    • /
    • 2006
  • Deep circumflex iliac artery (DCIA) flap can be harvested as a composite free flap and is often used to adequately reconstruct wide mandibular defects. However, the harvesting of this DCIA flap can result in severe osseous defect of the donor site causing a morphologic defect in the iliac crest. To reconstruct this defect of the iliac donor site, several innovative techniques using bioactive ceramic spacers, autogenous rib bone, polylactic acid mesh, or titanium plates have been introduced. Nonetheless, these methods have not been widely used due to high cost, secondary donor site morbidity, difficulty of use, and postoperative dissatisfaction. We used two titanium plates to reconstruct the donor iliac site defect at the harvesting time of primary DCIA flap surgery in the 30-year old female with an ameloblastoma in the left mandible. Postoperatively, both iliac sites were relatively balanced and there were few complications. At the 2 years follow-up, there were no specific abnormal radiographic findings and the patient was very satisfied with her esthetic iliac contouring. In our report, we evaluate the effect of two titanium plates on the reconstruction of the iliac donor site in the aspects of esthetics and usefulness. This technique has many advantages, such as reduced cost, simplicity, decreased postoperative pain or discomfort, and improved bilateral balance of both anterior iliac crest contours, especially in young female patients.

스테인리스 스틸 강선(STS 316Ti)의 웨이브 성형 시 발생되는 금형 치절에 의한 찍임 자국 최소화에 관한 연구 (A Study on the Minimization of Dent Marks due to Mold Tooth Teeth Generated During Wave Forming of Stainless Steel Wire (STS 316Ti))

  • 문현철;배수한;성효경
    • 한국기계가공학회지
    • /
    • 제21권6호
    • /
    • pp.98-106
    • /
    • 2022
  • Among the parts assembled in the gas receiver of a marine engine, the titanium alloy stainless steel (STS 316Ti) wire mesh serving as a filter was broken, and the related part, the turbine fan of the turbocharger, was damaged. In this study, a sample of the grid wire mesh was collected and the cause of breakage was analyzed, and a method of minimizing the dent mark caused by the mold during wire forming, which is one of the most direct causes, was studied. In addition, the optimum mold shape was realized through FEM simulation, and the wire wave molding machine capable of controlling the speed was improved by supplementing the problems of the existing wire wave molding machine, thereby improving durability with minimal dent marks.

티타늄 금속지지체에 고정화된 나노튜브 광촉매와 평판형 광반응기를 이용한 Cr(VI) 환원처리 효율 향상 연구 (Enhanced photocatalytic Cr(VI) reduction using immobilized nanotubular TiO2 on Ti substrates and flat type photoreactor)

  • 김영지;주현규;윤재경
    • 상하수도학회지
    • /
    • 제29권1호
    • /
    • pp.33-38
    • /
    • 2015
  • In this study, flat-type photocatalytic reaction system is applied to reduce toxic hexavalent chromium (Cr(VI)) to trivalent chromium (Cr(III)) in aqueous solution under UV irradiation. To overcome the limitation of conventional photocatalysis, a novel approach toward photocatalytic system for reduction of hexavalent chromium including nanotubular $TiO_2$ (NTT) on two kinds of titanium substrates (foil and mesh) were established. In addition, modified Ti substrates were prepared by bending treatment to increase reaction efficiency of Cr(VI) in the flat-type photocatalytic reactor. For the fabrication of NTT on Ti substrates, Ti foil and mesh was anodized with mixed electrolytes ($NH_4F-H_2O-C_2H_6O_2$) and then annealed in ambient oxygen. The prepared NTT arrays were uniformly grown on two Ti substrates and surface property measurements were performed through SEM and XRD. Hydraulic retention time(HRT) and substrate type were significantly affected the Cr(VI) reduction. Hence, the photocatalytic Cr(VI) reduction was observed to be highest up to 95% at bended(modified) Ti mesh and lowest HRT. Especially, Ti mesh was more effective as NTT substrate in this research.

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE PLATFORM SWITCHING

  • Kim Yang-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제43권6호
    • /
    • pp.727-735
    • /
    • 2005
  • Statement of problem. Platform switching in implant prosthesis has been used for esthetic and biological purpose. But there are few reports for this concept. Purpose. The purpose of this study is evaluation of platform switching in wide implant by three dimensional finite element analysis. Materials and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for Osstem implant system. Three-dimensional finite element models were developed for (1) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with wide cemented abutment, titanium alloy abutment screw, and prosthesis (2) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with regular cemented abutment, titanium alloy abutment screw and prosthesis(platform switching) was made for finite element analysis. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized to 650N, and round and flat type prostheses were loaded to 200 N. Four loading offset point (0, 2, 4, 6 mm from the center of the implants) were evaluated. Models were processed by the software programs HyperMesh and ANSA. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView were used for post processing. Results. The results from experiment were as follows; 1. von Mises stress value is increased in order of bone, abutment, implant and abutment screw. 2. von Mises stress of abutment screw is lower when platform switching. 3. von Mises stress of implant is lower when platform switching until loading offset 4 mm. 4. von Mises stress of abutment is similar between each other. 5. von Mises stress of bone is slightly higher when platform switching. Conclusion. The von Mises stress pattern of implant components is favor when platform switch ing but slightly higher in bone stress distribution than use of wide abutment. The research about stress distribution is essential for investigation of the cortical bone loss.

The effect of overlaying titanium mesh with collagen membrane for ridge preservation

  • Lim, Hyun-Chang;Lee, Jung-Seok;Choi, Seong-Ho;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • 제45권4호
    • /
    • pp.128-135
    • /
    • 2015
  • Purpose: The aim of this study was to determine the effect of overlaying titanium mesh (TM) with an adjunctive collagen membrane (CM) for preserving the buccal bone when used in association with immediate implant placement in dogs. Methods: Immediate implant placements were performed in the mesial sockets of the third premolars of five dogs. At one site the TM was attached to the fixture with the aid of its own stabilizers and then covered by a CM (CM group), while the contralateral site received only TM (TM group). Biopsy specimens were retrieved for histologic and histomorphometric analyses after 16 weeks. Results: All samples exhibited pronounced buccal bone resorption, and a high rate of TM exposure was noted (in three and four cases of the five samples in each of the TM and CM groups, respectively). A dense fibrous tissue with little vascularity or cellularity had infiltrated through the pores of the TM irrespective of the presence of a CM. The distances between the fixture platform and the first bone-implant contact and the bone crest did not differ significantly between the TM and CM groups. Conclusions: Our study suggests that the additional use of a CM over TM does not offer added benefit for mucosal healing and buccal bone preservation.

Clinical Significance of Radiological Stability in Reconstructed Thoracic and Lumbar Spine Following Vertebral Body Resection

  • Sung, Sang-Hyun;Chang, Ung-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권4호
    • /
    • pp.323-329
    • /
    • 2014
  • Objective : Vertebral body replacement following corpectomy in thoracic or lumbar spine is performed with titanium mesh cage (TMC) containing any grafts. Radiological changes often occur on follow-up. This study investigated the relationship between the radiological stability and clinical symptoms. Methods : The subjects of this study were 28 patients who underwent corpectomy on the thoracic or lumbar spine. Their medical records and radiological data were retrospectively analyzed. There were 23 cases of tumor, 2 cases of trauma, and 3 cases of infection. During operation, spinal reconstruction was done with TMC and additional screw fixation. We measured TMC settlement in sagittal plane and spinal angular change in coronal and sagittal plane at postoperative one month and last follow-up. Pain score was also checked. We investigated the correlation between radiologic change and pain status. Whether factors, such as the kind of graft material, surgical approach, and fusion can affect the radiological stability or not was analyzed as well. Results : Mean follow-up was 23.6 months. During follow-up, $2.08{\pm}1.65^{\circ}$ and $6.96{\pm}2.08^{\circ}$ of angular change was observed in coronal and sagittal plane, respectively. A mean of cage settlement was $4.02{\pm}2.83mm$. Pain aggravation was observed in 4 cases. However, no significant relationship was found between spinal angular change and pain status (p=0.518, 0.458). Cage settlement was seen not to be related with pain status, either (p=0.644). No factors were found to affect the radiological stability. Conclusion : TMC settlement and spinal angular change were often observed in reconstructed spine. However, these changes did not always cause postoperative axial pain.

Comparison of Clinical and Radiologic Results between Expandable Cages and Titanium Mesh Cages for Thoracolumbar Burst Fracture

  • Lee, Gwang-Jun;Lee, Jung-Kil;Hur, Hyuk;Jang, Jae-Won;Kim, Tae-Sun;Kim, Soo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권3호
    • /
    • pp.142-147
    • /
    • 2014
  • Objective : A thoracolumbar burst fracture is usually unstable and can cause neurological deficits and angular deformity. Patients with unstable thoracolumbar burst fracture usually need surgery for decompression of the spinal canal, correction of the angular deformity, and stabilization of the spinal column. We compared two struts, titanium mesh cages (TMCs) and expandable cages. Methods : 33 patients, who underwent anterior thoracolumbar reconstruction using either TMCs (n=16) or expandable cages (n=17) between June 2000 and September 2011 were included in this study. Clinical outcome was measured by visual analogue scale (VAS), American Spinal Injury Association (ASIA) scale and Low Back Outcome Score (LBOS) for functional neurological evaluation. The Cobb angle, body height of the fractured vertebra, the operation time and amount of intra-operative bleeding were measured in both groups. Results : In the expandable cage group, operation time and amount of intraoperative blood loss were lower than that in the TMC group. The mean VAS scores and LBOS in both groups were improved, but no significant difference. Cobb angle was corrected higher than that in expandable cage group from postoperative to the last follow-up. The change in Cobb angles between preoperative, postoperative, and the last follow-up did not show any significant difference. There was no difference in the subsidence of anterior body height between both groups. Conclusion : There was no significant difference in the change in Cobb angles with an inter-group comparison, the expandable cage group showed better results in loss of kyphosis correction, operation time, and amount of intraoperative blood loss.

Functional Outcomes of Subaxial Spine Injuries Managed With 2-Level Anterior Cervical Corpectomy and Fusion: A Prospective Study

  • Jain, Vaibhav;Madan, Ankit;Thakur, Manoj;Thakur, Amit
    • Neurospine
    • /
    • 제15권4호
    • /
    • pp.368-375
    • /
    • 2018
  • Objective: To evaluate the results of operative management of subaxial spine injuries managed with 2-level anterior cervical corpectomy and fusion with a cervical locking plate and autologous bone-filled titanium mesh cage. Methods: This study included 23 patients with a subaxial spine injury who matched the inclusion criteria, underwent 2-level anterior cervical corpectomy and fusion at our institution between 2013 and 2016, and were followed up for neurological recovery, axial pain, fusion, pseudarthrosis, and implant failure. Results: According to Allen and Ferguson classification, there were 9 cases of distractive extension; 4 of compressive extension; 3 each of compressive flexion, vertical compression, and distractive flexion; and 1 of lateral flexion. Sixteen patients had a score of 6 on the Subaxial Injury Classification system, and the rest had a score of more than 6. The mean follow-up period was 19 months (range, 12-48 months). Neurological recovery was observed in most of the patients (78.21%). All patients experienced relief of axial pain. None of the patients received a blood transfusion. Twenty-one patients (91.3%) showed solid fusion and 2 (8.69%) showed possible pseudarthrosis, with no complications related to the cage or plate. Conclusion: Two-level anterior cervical corpectomy and fusion, along with stabilization with a cervical locking plate and autologous bone graft-filled titanium mesh cage, can be considered a feasible and safe method for treating specific subaxial spine injuries, with the benefits of high primary stability, anatomical reduction, and direct decompression of the spinal cord.

Surgical Reconstruction Using a Flanged Mesh Cage without Plating for Cervical Spondylotic Myelopathy and a Symptomatic Ossified Posterior Longitudinal Ligament

  • Kang, Jung Hoon;Im, Soo-Bin;Yang, Sang-Mi;Chung, Moonyoung;Jeong, Je Hoon;Kim, Bum-Tae;Hwang, Sun-Chul;Shin, Dong-Seong;Park, Jong-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권6호
    • /
    • pp.671-680
    • /
    • 2019
  • Objective : We introduce innovative method of cervical column reconstruction and performed the reconstruction with a flanged titanium mesh cage (TMC) instead of a plate after anterior corpectomy for cervical spondylotic myelopathy (CSM) and an ossified posterior longitudinal ligament (OPLL). Methods : Fifty patients with CSM or OPLL who underwent anterior cervical reconstruction with a flanged TMC were investigated retrospectively. Odom's criteria were used to assess the clinical outcomes. The radiographic evaluation included TMC subsidence, fusion status, and interbody height. Thirty-eight patients underwent single-level and 12 patients underwent two-level corpectomy with a mean follow-up period of 16.8 months. Results : In all, 19 patients (38%) had excellent outcomes and 25 patients (50%) had good outcomes. Two patients (4%) in whom C5 palsy occurred were categorized as poor. The fusion rate at the last follow-up was 98%, and the severe subsidence rate was 34%. No differences in subsidence were observed among Odom's criteria or between the single-level and two-level corpectomy groups. Conclusion : The satisfactory outcomes in this study indicate that the flanged TMC is an effective graft for cervical reconstruction.