• Title/Summary/Keyword: Titanium implant

Search Result 578, Processing Time 0.039 seconds

Microstructure and Corrosion Behavior of Various Grain Size Cp-Ti (입자크기를 달리한 Cp-Ti의 미세구조 관찰 및 SBF하에서의 부식거동)

  • Lee Seung-Woo;Kim Yun-Jong;Ruy Jae-Gyeoung;Park Joong-Keun;Kim Won-Soo;Kim Taik-Nam
    • Korean Journal of Materials Research
    • /
    • v.15 no.9
    • /
    • pp.585-588
    • /
    • 2005
  • Titanium and Titanium alloys are widely used as an orthopedic and dental implant material because of their excellent biocompatibility and mechanical strength. In this study, ECAP Cp-Ti and Cp-Ti were heat treated for different annealing time of 30 min, 90 min and 3 hours. The grain size for each condition was studied. The micro-Vicker hardness test was carried out f3r each different heat treated samples. The micro-Vicker hardness test for ECAP Cp-Ti, Cp-Ti and Cp-Ti (3hr) revealed hardness values of 239.5, 182 and 144 Hv, respectively. The grain size was increased from approximately $70{\mu}m\;to\;300{\mu}m$ with the increase in heat treatment time from 30 min to 3 hours. The heat treated samples were tested for their biocompatibility in simulated body fluid (SBF) and corrosion rates was determined using Polarization Curve test (PCT). The PCT results showed Cp-Ti with comparatively high corrosion potential of -0.18 V and corresponding corrosion current of $2\times10^{-6}$ A, while the corrosion rate in ECAP Cp-Ti and Cp-Ti (30 min annealed) showed very similar results of corrosion potential about -0.47 V with corresponding corrosion current of $7\times10^{-8}$ A.

Functional Outcomes of Subaxial Spine Injuries Managed With 2-Level Anterior Cervical Corpectomy and Fusion: A Prospective Study

  • Jain, Vaibhav;Madan, Ankit;Thakur, Manoj;Thakur, Amit
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.368-375
    • /
    • 2018
  • Objective: To evaluate the results of operative management of subaxial spine injuries managed with 2-level anterior cervical corpectomy and fusion with a cervical locking plate and autologous bone-filled titanium mesh cage. Methods: This study included 23 patients with a subaxial spine injury who matched the inclusion criteria, underwent 2-level anterior cervical corpectomy and fusion at our institution between 2013 and 2016, and were followed up for neurological recovery, axial pain, fusion, pseudarthrosis, and implant failure. Results: According to Allen and Ferguson classification, there were 9 cases of distractive extension; 4 of compressive extension; 3 each of compressive flexion, vertical compression, and distractive flexion; and 1 of lateral flexion. Sixteen patients had a score of 6 on the Subaxial Injury Classification system, and the rest had a score of more than 6. The mean follow-up period was 19 months (range, 12-48 months). Neurological recovery was observed in most of the patients (78.21%). All patients experienced relief of axial pain. None of the patients received a blood transfusion. Twenty-one patients (91.3%) showed solid fusion and 2 (8.69%) showed possible pseudarthrosis, with no complications related to the cage or plate. Conclusion: Two-level anterior cervical corpectomy and fusion, along with stabilization with a cervical locking plate and autologous bone graft-filled titanium mesh cage, can be considered a feasible and safe method for treating specific subaxial spine injuries, with the benefits of high primary stability, anatomical reduction, and direct decompression of the spinal cord.

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

Titanium-zirconium alloy narrow-diameter implants for the rehabilitation of horizontally deficient mandibular posterior edentulous ridges (좁은 치조제를 가진 하악 구치부에서 지르코늄-티타늄 합금의 작은 직경 임플란트 사용 증례)

  • Lee, In Hye;Park, Young Bum;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.212-217
    • /
    • 2017
  • In case of the insufficient horizontal bone loss, a regular diameter implant is not possible without lateral bone augmentation. In this situation, narrow diameter implants (NDIs) could be the alternative to lateral bone augmentation procedures. However, complication generally expected with the NDI is implant fracture. Recently, the survival rate and success rate of NDI in the posterior region are similar to that of standard-diameter implants (SDIs). These 3 case reports demonstrate the incorporation of NDI to replace missing mandibular posterior teeth. So far, the follow-up examination period was maintained and no unusual complications were presented for more than four years. Long term follow-up clinical data are needed to confirm the excellent clinical performance of these implants.

Analysis of osteogenic potential on 3mol% yttria-stabilized tetragonal zirconia polycrystals and two different niobium oxide containing zirconia ceramics

  • Hein, Aung Thu;Cho, Young-Dan;Jo, Ye-Hyeon;Kim, Dae-Joon;Han, Jung-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.147-154
    • /
    • 2018
  • PURPOSE. This study was performed to evaluate the osteogenic potential of 3mol% yttria-stabilized tetragonal zirconia polycrystals (3Y-TZP) and niobium oxide containing Y-TZPs with specific ratios, new (Y,Nb)-TZPs, namely YN4533 and YN4533/Al20 discs. MATERIALS AND METHODS. 3Y-TZP, YN4533 and YN4533/Al20 discs (15 mm diameter and 1 mm thickness) were prepared and their average surface roughness ($R_a$) and surface topography were analyzed using 3-D confocal laser microscope (CLSM) and scanning electron microscope (SEM). Mouse pre-osteoblast MC3T3-E1 cells were seeded onto all zirconia discs and evaluated with regard to cell attachment and morphology by (CLSM), cell proliferation by PicoGreen assay, and cell differentiation by Reverse-Transcription PCR and Quantitative Real-Time PCR, and alkaline phosphatase (Alp) staining. RESULTS. The cellular morphology of MC3T3-E1 pre-osteoblasts was more stretched on a smooth surface than on a rough surface, regardless of the material. Cellular proliferation was higher on smooth surfaces, but there were no significant differences between 3Y-TZP, YN4533, and YN4533/Al20. Osteoblast differentiation patterns on YN4533 and YN4533/Al20 were similar to or slightly higher than seen in 3Y-TZP. Although there were no significant differences in bone marker gene expression (alkaline phosphatase and osteocalcin), Alp staining indicated better osteoblast differentiation on YN4533 and YN4533/Al20 compared to 3Y-TZP. CONCLUSION. Based on these results, niobium oxide containing Y-TZPs have comparable osteogenic potential to 3Y-TZP and are expected to be suitable alternative ceramics dental implant materials to titanium for aesthetically important areas.

Clinical Experience of Anterior Cervical Interbody Fusion with the PCB System (전방 경추 유합술에서의 PCB System의 임상적 경험)

  • Kim, Sung Han;Kim, Ho Jin;Kang, Jae Kyu;Doh, Jong Oung;Lee, Chun Dae
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1170-1176
    • /
    • 2001
  • Objective : The purpose of the study was to evaluate the clinical and radiological results after discectomy and Lubboc bone graft in the surgical management of the cervical diseases with a new titanium interbody implant and integrated screw fixation(PCB) by anterior approach. Methods : The authors retrospectively analyzed 28 cases of anterior cervical fusion with PCB system and Lubboc bone(xeno graft) from september 1998 to december 2000. Twenty-eight patients with cervical diseases underwent decompression cervical lesion and followed from 5 to 27 months with a mean follow-up of 14 months. There patients were evaluated with clinically and radiologically at immediate postoperative period and at 3, 6, 9, and 12 months. Result : The authors investigated the pre- and postoperative intervertebral disc space, clinical outcomes, radiography fusion rate, and Cobb angle in the fixed segments by anterior approach. The lordotic angles and height of disc space were increased after the operation. The clinical outcome of patients follow-up was good or excellent result based on Odom's criteria with improvement of clinical symptom in about 92.9% of the cervical diseases. Two patients showed loosening of the lower and upper cervical screw of PCB instruments, and two patients showed swallowing difficulty and wound infection Conclusion : The PCB system is a new implant for anterior cervical interbody fusion in the degenerative cervical disease and disc herniations. It provides immediate stability and segment distraction. The results of this study indicate that the PCB system is safe, easy handling of hardware, less complications, high fusion rate, and has provide the keeping the intervertebral disc space height and lordotic angles.

  • PDF

Electrochemical Behavior of Plasma Electrolytic Oxidized Films Formed in Solution Containing Mn, Mg and Si Ions

  • Lim, Sang-Gyu;Choe, Han Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.80-80
    • /
    • 2017
  • Titanium and its alloys that have a good biocompatibility, corrosion resistance, and mechanical properties such as hardness and wear resistance are widely used in dental and orthopedic implant applications. However, they do not form a chemical bond with bone tissue. Plasma electrolytic oxidation (PEO) that combines the high voltage spark and electro-chemical oxidation is a novel method to form ceramic coatings on light metals such as tita-nium and its alloys. This is an excellent re-producibility and economical, because the size and shape control of the nano-structure is relatively easy. Silicon (Si), manganese (Mn), and magne-sium (Mg) have a useful to bone. Particularly, Si has been found to be essential for normal bone, cartilage growth, and development. Mn influences regulation of bone remodeling be-cause its low content in body is connected with the rise of the concentration of calcium, phosphates and phosphatase out of cells. Pre-studies have shown that Mg plays very im-portant roles in essential for normal growth and metabolism of skeletal tissue in verte-brates and can be detected as minor constitu-ents in teeth and bone. In this study, Electrochemical behavior of plasma electrolytic oxidized films formed in solution containing Mn, Mg and Si ions were researched using various experimental in-struments. A series of Si-Mn-Mg coatings are produced on Ti dental implant using PEO, with the substitution degree, respectively, at 5 and 10%. The potentiodynamic polarization and AC impedance tests for corrosion behav-iors were carried out in 0.9% NaCl solution at similar body temperature using a potentiostat with a scan rate of 1.67mV/s and potential range from -1500mV to + 2000mV. Also, AC impedance was performed at frequencies anging from 10MHz to 100kHz for corrosion resistance.

  • PDF

Long-term Evaluation of IMZ Implants;Success and Survival Rates (IMZ 임플란트의 장기적 성공률과 실패율)

  • Park, Ji-Eun;Kim, Tae-Gyun;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.1039-1052
    • /
    • 2005
  • IMZ는 "intramobile cylinder implant system" (IMZ)로 독일에서 가장 오래되고 많이 사용되어진 임플란트 중 하나이다. 이 임플란트에 관한 장기적 성공률과 생존률에 대한 연구는 대개 80% 이상을 보고하고 있다. 그러나, 연세대학교 치과병원 치주과에서 식립된 83개의 임플란트에서는 이전의 연구와는 다른 결과를 나타내었다. 1. IMZ 임플란트의 생존률은 67.5% 였다. 2. 변연 치조골 소실에 대한 성공 기준을 적용한 결과 성공률은 49.4%로 나타났다. 3. 발거된 총 27개의 임플란트 중에서 임플란트 주위 골소실을 가지는 경우는 17개, 내부구조 파절은 4개, 식립체 파절은 5개로 보고되었다. 4. 10년 이상 생존된 임플란트에서 변연골 소실의 평균치는 2.82mm였다. IMZ 임플란트는 장기적으로 높은 실패율을 보고하였다. 이는 cylindrical design, titanium plasma flame spray coating, prosthodontic complication 등의 요소에 기인한 것으로 사료된다. 임플란트는 그 형태, 표면 처리 등 여러 가지 요인들에 의해 실패가 나타날 수 있으며 본 연구를 통해 임플란트의 개발 및 선택에 바탕이 될 수 있을 것으로 생각된다.

Implant surface treatments affect gene expression of Runx2, osteogenic key marker

  • Na, Young;Heo, Seong-Joo;Kim, Seong-Kyun;Koak, Jai-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.91-96
    • /
    • 2009
  • STATEMENT OF PROBLEM. The aim of this study was to study the effects of various surface treatments to a titanium surface on the expression of Runx2 in vitro. MATERIAL AND METHODS. Human Osteosarcoma TE-85 cells were cultured on machined, sandblasted, or anodic oxidized cpTi discs. At various times of incubation, the cells were collected and then processed for the analysis of mRNA expression of Runx2 using reverse transcription-PCR. RESULTS. The expression pattern of Runx2 mRNA was differed according to the types of surface treatment. When the cells were cultured on the untreated control culture plates, the gene expression of Runx2 was not increased during the experiments. In the case of that the cells were cultured on the machined cpTI discs, the expression level was intermediate at the first day, but increased constitutively to day 5. In cells on sandblasted cpTi discs, the expression level was highest in the first day sample and the level was maintained to 5 days. In cells on anodized cpTi discs, the expression level increased rapidly to 3 days, but decreased slightly in the 5-th day sample. CONCLUSION. Different surface treatments may contribute to the regulation of osteoblast function by influencing the level of gene expression of key osteogenic factors.

Clinical reliability of zirconium abutment in implant restorations in the English and Korean literature

  • Yu, Su-Been;Song, Bong-Gyu;Cheon, Kyeong-Jun;Kim, Ju-Won;Kim, Young-Hee;Yang, Byoung-Eun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.26.1-26.10
    • /
    • 2018
  • Background: This study aimed to evaluate the mechanical, biological, and esthetic stability of a zirconium abutment according to evidence-based dentistry. Main text: An electronic search was performed. Domestic studies were found using the keywords "zirconia abutments" and "zirconium abutment" in KMbase, KoreaMed, and the National Assembly Library, and international studies were found using the same keywords in PubMed. All identified studies were divided by evidence level from the viewpoint of the research type utilizing the evidence-based review manual. A total of 102 domestic studies (with Korean language) were found, and 9 of these studies were selected. In these nine studies, 3 had evidence level 3 and 6 had evidence level 4. A total of 97 international studies (with English language) were found, and 19 were selected. Among these 19 studies, 5 had evidence level 2 and 7 had evidence level 3, whereas the remainder had evidence level 4. According to the studies, zirconium abutments are mechanically, biologically, and esthetically stable, but the evidence level of these studies is low, and the follow-up duration is no longer than 5 years. Conclusions: All examined studies verified the mechanical stability of zirconium abutments for a period no longer than 5 years. Therefore, a long-term clinical observation is needed. Zirconium abutments are thought to be biologically stable, but they are not superior to titanium abutments. As the esthetic stability of such abutments had a low evidence level in the studies that examined here, a much higher evidence level is needed.