• 제목/요약/키워드: Titanium implant

검색결과 575건 처리시간 0.022초

염산테트라싸이클린이 임플란트 표면에 미치는 효과;주사전자현미경적 연구 (Effect of Application of Tetracycline - HCl on Implant Surface;Scanning Electron Microscopic Study)

  • 홍정아;허익;이만섭;박준봉
    • Journal of Periodontal and Implant Science
    • /
    • 제31권2호
    • /
    • pp.333-344
    • /
    • 2001
  • The present study was performed to evaluate the effect of tetracycline - HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface and titanium plasma-sprayed surface were utilized. Implant surface was rubbed with 50mg/ml tetracycline - HCl solution for 1 min., $1\frac{1}{2}\;min$., 2 min., $2\frac{1}{2}\;min$. and 3min. respectively in the test group and with saline for 1 min. in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. Pure titanium machined surfaces conditioned with saline for 1 min., showed a few shallow grooves and ridges and were less irregular. 2. Pure titanium machined surfaces conditioned with 50mg/ml tetracycline - HCl solution showed more irregular and corrosive surfaces compared to the control group irrespective of the application time of tetracycline - HCl solution. 3. Titanium plasma-sprayed surfaces conditioned with saline for 1 min., were deposited with round amorphous particles and showed round or irregular pores that can be connected to each other. 4. The irregularity of titanium plasma-sprayed surfaces conditioned with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas were wider relative to the application time of tetracycline - HCl solution. 5. Titanium plasma-sprayed surfaces conditioned with tetracycline - HCl solution for 1 min. and $1\frac{1}{2}\;min$. were very similar to that of the control group, but the surfaces conditioned for 2 min., $2\frac{1}{2}\; min$. and 3 min. were changed. In conclusion, pure titanium machined surfaces were changed irrespective of the application time of tetracycline - HCl solution. And titanium plasma-sprayed surfaces conditioned with tetracycline - HCl solution began to be changed from $1\frac{1}{2}\;min$. This results will be applicable to the regenerative procedures for peri-implantitis treatment.

  • PDF

A STUDY ON SURFACE ALTERATION OF IMPLANT SCREWS AFTER FUNCTION

  • Han, Myung-Ju;Chung, Chae-Heon;Choi, Han-Cheol
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.275-286
    • /
    • 2002
  • Statement of problem. Surface alteration of the implant screws after function may be associated with mechanical failure. Theses metal fatigue appears to be the most common cause of structural failure. Purpose. The purpose of this study was to evaluate surface alteration of the implant screws after function through the examination of used and unused implant screws in SEM(scanning electron microscope). Materials and methods. In this study, abutment screws(Steri-oss, 3i), gold retaining screw(3i) and titanium retaining screw(3i) were retrieved from patients. New, unused abutment and retaining screws were prepared for control group. Each of the old, used screws was retrieved with a screwdriver. And retrieved implant complex of Steri-oss system was prepared for this study. Then, SEM investigation and EDS analysis of abutment and retaining screws were performed. And SEM investigation of cross-sectioned sample of retrieved implant complex was performed. Results. In the case of new, unused implant screws, as maunfactured circumferential grooves are regularly examined and screw thread are sharply remained. Before ultrasonic cleansing of old, used implant screw, a lot of accumulation and corrosion products were existed. After ultrasonic cleansing of old, used implant screws, circumferential grooves as examined before function were randomly deepened and scratches increased. Also, dull screw thread was examined. More surface alterations after function were examined in titanium screw than gold screw. And more surface alteration was examined when retrieved with driver than retrieved without driver. Conclusions. These surface alteration after function may result in the screw instability. Regularly cleansing and exchange of screws was recommended. We recommend the use of gold screw rather than titanium screw, and careful manipulation of the driver.

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE PLATFORM SWITCHING

  • Kim Yang-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제43권6호
    • /
    • pp.727-735
    • /
    • 2005
  • Statement of problem. Platform switching in implant prosthesis has been used for esthetic and biological purpose. But there are few reports for this concept. Purpose. The purpose of this study is evaluation of platform switching in wide implant by three dimensional finite element analysis. Materials and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for Osstem implant system. Three-dimensional finite element models were developed for (1) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with wide cemented abutment, titanium alloy abutment screw, and prosthesis (2) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with regular cemented abutment, titanium alloy abutment screw and prosthesis(platform switching) was made for finite element analysis. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized to 650N, and round and flat type prostheses were loaded to 200 N. Four loading offset point (0, 2, 4, 6 mm from the center of the implants) were evaluated. Models were processed by the software programs HyperMesh and ANSA. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView were used for post processing. Results. The results from experiment were as follows; 1. von Mises stress value is increased in order of bone, abutment, implant and abutment screw. 2. von Mises stress of abutment screw is lower when platform switching. 3. von Mises stress of implant is lower when platform switching until loading offset 4 mm. 4. von Mises stress of abutment is similar between each other. 5. von Mises stress of bone is slightly higher when platform switching. Conclusion. The von Mises stress pattern of implant components is favor when platform switch ing but slightly higher in bone stress distribution than use of wide abutment. The research about stress distribution is essential for investigation of the cortical bone loss.

Space holder 공정으로 제조된 치과 임플란트용 타이타늄 다공체의 파손 분석 (Fracture Analysis of Porous Titanium for Dental Implant Fabricated by Space Holder Process)

  • 이승미;장진만;이원식;변재원
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권2호
    • /
    • pp.104-109
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze fracture behavior and failure mechanism of porous titanium for dental implant fabricated by space holder process. Method: Three porous titanium specimens with a specific volume fraction of open pore were test by 3 point bending and compression stress condition, respectively. Fracture appearance was observed by scanning electron microscope and discussed in relation with oxygen content. Results: For compression-tested specimens, two specimen showed brittle failure, while the other one showed normal failure after deformation. High oxygen content was detected in the brittle-fractured specimen. Several micro-cracks initiated at the struts propagated down to the bottom of the specimen resulting in normal failure. Conclusion: Oxygen contamination during the fabrication process can leads brittle premature failure, and hence quality problem of the porous titanium for dental implant.

A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures

  • Choi, Tae Joon;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Plastic Surgery
    • /
    • 제43권1호
    • /
    • pp.84-87
    • /
    • 2016
  • Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium mesh sheet impede the efficacious and minimally traumatic insertion of the implant, because these spurs may catch or hook the orbital soft tissue, skin, or conjunctiva during the insertion procedure. In order to prevent this problem, we developed an easy method of inserting a titanium micro-mesh, in which it is wrapped with the aseptic transparent plastic film that is used to pack surgical instruments or is attached to one side of the inner suture package. Fifty-four patients underwent orbital wall reconstruction using a transconjunctival or transcutaneous approach. The wrapped implant was easily inserted without catching or injuring the orbital soft tissue, skin, or conjunctiva. In most cases, the implant was inserted in one attempt. Postoperative computed tomographic scans showed excellent placement of the titanium micro-mesh and adequate anatomic reconstruction of the orbital walls. This wrapping insertion method may be useful for making the insertion of titanium micro-mesh implants in the reconstruction of orbital wall fractures easier and less traumatic.

성경 대퇴골에 매식된 Titanium Plasma Spray 및 Hydroxyapatite 피복임프란트 주위의 골치유 양상 (HISTOLOGIC EvALUATION OF BONE HEALING AROUND TITANIUM PLASMA SPRAYED AND HYDROXYAPATITE-COATED IMPLANTS IN DOGS)

  • 허기남;정현주
    • Journal of Periodontal and Implant Science
    • /
    • 제25권2호
    • /
    • pp.418-437
    • /
    • 1995
  • The effect of the hydroxyapatite coatings on Titanium implants has been the subject of recent investigations. So far, the use of HA coating remains substantially controversial.This study was aimed to evaluate histologically the bone healing patterns around titanium plasm sprayed(TPS) amd HA-coated implant after implantation into the femur neck of ten adult dogs. After implantation, animals were sacrificed at the intervals of 2,4,6,8 and 12 weeks.The fluorescent dyes were injected on the postoperative 4th and 12th week into the animals supposed to be killed at the 12th week. The morphology and direction of new bone formation was similar in both TPS and HA-coated implants.There was a tendency toward more bone formation in the cortical bone area than in the cancellous bone area. Histologically,in the interface of the HA-coated implants, bone response and bone maturation was faster, compared to the TPS implants in the 2nd and 4th week. By fluorescent microscopy, new bone formation was active in the 4th week around both implants and was directed from the periosteum overlying cortical bone to the cancellous bone. These results suggest that the bone formation and maturation is faster during the early healing stage in the interface of the HA-coated implant and where the cortical bone quality is poor, HA coated implant is superior to the TPS implant in the early phase of new bone formation.

  • PDF

임상가를 위한 특집 3 - 심하게 흡수된 치조제를 가진 환자에서 CAD/CAM을 이용한 임플란트 고정성 보철치료 (Implant fixed prosthetic treatment using CAD/CAM system in a patient with severe alveolar resorption)

  • 최유성
    • 대한치과의사협회지
    • /
    • 제50권3호
    • /
    • pp.126-139
    • /
    • 2012
  • Loss of dentition can lead to not only compromised esthetics and functions of the patient, but also alveolar bone resorption. Bone grafting with prosthetic reconstruction of the gingiva can be selected for the treatment, and it provides many benefits as prosthetic gingival reconstruction does not require a complicated surgical process and is available within a short period of time, with stable clinical results. However, conventional porcelain fused to metal prosthesis has certain limits due to its size, and deformation after several firing procedures. In this clinical report, the author would like to introduce a patient with severe alveolar resorption who was treated with gingiva-shaped zirconia/titanium CAD/CAM implant fixed prosthesis for esthetic and functional rehabilitation. Clinical reports Clinical report 1, 2 : A case of loss of anterior dentition with atrophied alveolar bone. Implant retained zirconia bridge applied with Procera implant bridge system to simulate the gingiva. Upper structure was fabricated with zirconia all ceramic crown. Clinical report 3, 4 : A case of atrophied maxillary alveolus was reconstructed with fixed implant prosthesis, a CAD/CAM designed titanium structure covered wi th resin on its surface. Anterior dentition was reconstructed with zirconia crown. Conclusion and clinical uses. All patients were satisfied with the outcome, and maintained good oral hygiene. Zirconia/titanium implant fixed prosthesis fabricated by CAD/CAM system was highly accurate and showed adequate histological response. No critical failure was seen on the implant fixture and abutment overall. Sites of severe alveolar bone loss can be rehabilitated by implant fixed prosthesis with CAD/CAM system. This type of prosthesis can offer artificial gingival structure and can give more satisfying esthetics and functions, and as a result the patients were able to accept the outcome more fondly, which makes us less than hard to think that it can be a more convenient treatment for the practitioners.

상악 완전 무치악에서 $Locator^{(R)}$ attachment가 장착된 milled titanium bar를 이용한 임플란트 지지 피개의치: 증례 보고 (Implant Supported Overdenture using Milled Titanium Bar with $Locator^{(R)}$ Attachment on Fully Edentulous Maxillae : A Case Report)

  • 오상천;한지석;김민정
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.223-231
    • /
    • 2011
  • 본 증례 보고의 목적은 상악 무치악 환자에서 임플란트 지지 피개의치를 위한 $Locator^{(R)}$ attachment가 장착된 새로운 milled titanium bar를 소개하고 새로운 대안으로써의 가능성을 제시하고자 함이다. 56세 남자 환자가 상악 고정성 보철물(10-유닛 브릿지)의 동요도를 주소로 본원에 내원하였다. 악관절 및 치과 치료에 영향을 줄만한 특이한 전신병력은 없었다. 방사선 검사 및 임상 검사 결과, 상악의 경우 모든 잔존치아에서 심한 골흡수와 동요도를 보이고 있어 전악 발치를 시행한 후, 임플란트 지지 피개의치를 제작하기로 하였다. 의치의 안정성과 유지력, 저작효율, 청소의 용이성, 심미성과 발음 그리고 경제적인 측면을 고려하여 $Locator^{(R)}$ 어태치먼트를 CAD/CAM으로 제작된 milled titanium bar에 탭핑(tapping)으로 연결시키는 새로운 디자인을 고안하였으며, 1년 이상 경과 후, 기능과 심미적인 면에서 만족할 만한 성과를 얻었기에 이를 보고하는 바이다.

기계적 표면 처리된 TITANIUM PLASMA SPRAYED IMPLANT에 대한 치은섬유아세포전개양상의 형태학적 관찰 (THE MORPHOLOGICAL OBSERVATION OF HUMAN GINGIVAL FIBROBLASTS ATTACHMENT AND SPREADING ON THE MECHANICAL TREATED TITANIUM PLASMA SPRAYED IMPLANT SURFACE)

  • 황연희;이재목;서조영
    • Journal of Periodontal and Implant Science
    • /
    • 제25권3호
    • /
    • pp.741-755
    • /
    • 1995
  • 구강내 매식된 임프란트가 과도한 교합력이나 염증등의 이유로 구강내로 노출되었을 때 세균독소에 이완된 면을 제거하고 평활한 면을 형성하여 주위의 연조직, 경조직에 적합한 상태로 만들어 건강한 상태로 구강내에 유지하기 위해서 임프란트 매식체 표면을 기계적인 표면처리방법으로 처치하여 이러한 방법이 임프란트 표면성분, 치은섬유아세포의 전개양상에 미치는 영향을 알아보고자 본 실험을 실행하였다. IMZ사에서 제작한 직경 10mm, 높이 2mm의 원판 타이타늄을 이용하여 피막되지 않은 타이타늄면과 TPS면을 대조군으로 하고 기계적인 표면처리방법인 low speed stone bur처치면을 실험군으로 설정한 후 EDX로 타이타늄 표면성분을 분석하였고 주사전자현미경으로 치은섬유아세포의 전개양상을 관찰하였다. EDX에 의한 타이타늄 표면성분분석 결과 모든 실험군에서 titanium peak, 소량의 aluminum이 나타났으며 그외의 성분은 나타나지 않았다. 치은섬유아세포의 전개양상에 대한 주사전자현미경 관찰결과 평활한 타이타늄면에서 접종 30분 후 세사상돌기와 박판엽상으로 확장된 세포가 많이 관찰되며 6시간 후 신장된 치은섬유아세포가 시편에 밀착된 양상을 보였고 24시간 후 치은섬유아세포는 시편의 모든 면을 피개하며 가공시의 평행한 선을 따라 방향성을 띄었다. TPS가 잔존한 stone처치군에서 세포 접종 30분 후 세사상돌기가 적게 관찰되어 평활한 타이타늄면에 비해 초기부착이 늦은 것을 알 수 있었고 6, 24시간후 치은섬유아세포는 거친면으로 인해 시편에 밀착되지 못한 양상을 보였으나 평활한 타이타늄면과 연결되며 시편의 모든면을 피개하였다. TPS군에서 치은섬유아세포는 세포 접종 30분후 세사상돌기를 거의 찾아 볼 수 없어 초기부착이 다른군에 비해 늦으며 세포배양 6, 24시간후에도 시편에 밀착되지 못하고 박판상돌기가 가늘고 길게 돌출되어 여러면에 부착된 양상을 보였으며 세포가 부착되지 않은 TPS면이 관찰되었다.

  • PDF

임프란트에 부착하는 세균의 동정 및 효과적인 항생제 선택 (ORAL MICROBES ASSOCIATED WITH TITANIUM IMPLANT AND THEIR ANTIBIOTIC SUSCEPTIBILITY)

  • 김선권;유선열
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제19권4호
    • /
    • pp.383-394
    • /
    • 1997
  • This study was done to examine adherence of oral bacteria to titanium dental implant and to know the effective prophylactic antibiotics using an in vivo model. Three samples each of the implant material were set in an acrylic resin flange and placed in the maxillary buccal sulcus of twenty volunteers. At 6- and 54-hour intervals, each sample was placed on blood agar plate (BAP) and chocolate agar, and then they were incubated and identified. Also antibiotic susceptibility test was performed. The results obtained mere as follows ; 1. The microorganisms were chain-like Gram positive cocci and staphyline Gram positive cocci, Gram positive bacilli in order of frequency were found at 6-hour and 54-hour samples by Gram staining. 2. Streptococci was found predominantly at both 6-hour and 54-hour samples, but number of streptococci was decreased as compared to 6-hour samples. 3. There was no difference in the bacterial species adherent to implant between 6-hour and 54-hour samples. 4. All the microbes were sensitive to AMC (amoxacillin clavulanic acid), chloramphenicol, quinolone and vancomycin in the antibiotic susceptibility test. Above results suggest that streptococcus are mainly adhered to titanium implant after implant was placed in the oral cavity and AMC is the most recommendable antibiotics to prevent the peri-implant inflammation.

  • PDF