• 제목/요약/키워드: Titanium carbide

검색결과 132건 처리시간 0.031초

Ti(CN)기 탄화물질 세라믹스의 기계적 특성과 절삭성능 (Mechanical Properties and Cutting Performance of Ti(CN) Based Carbonitride Ceramics)

  • 박동수;이양두;정태주;강신후
    • 연구논문집
    • /
    • 통권28호
    • /
    • pp.193-207
    • /
    • 1998
  • Fully dense THCN) based carbonitride ceramics were fabricated by pressureless sintering. During sintering, solid solutions were formed from the ceramic ingredients. The ceramics exhibited microvickers hardness of 1560-2050kgf/mm2, fracture toughness of 3.0-5.4 MPa $m^(1/2)$, and three point flexural strength of 645-1072 MPa. Some of the ceramics were shaped in a cutting tool, and the cutting performance was evaluated. In case of cutting SCM440 alloy steel, the ceramics showed better performance than the commercially available alumina-titanium carbide ceramic cutting tool. Considering the excellent productivity of pressureless sintering compared with other densification methods and their cutting performance, this new class of ceramics are very promising for wear resistant applications.

  • PDF

Influence of Carbon Vacancies on CO Chemisorption on TiC(001): A Theoretical Study

  • Kang, Dae-Bok
    • 대한화학회지
    • /
    • 제61권1호
    • /
    • pp.7-11
    • /
    • 2017
  • The extended $H{\ddot{u}}ckel$ method is employed to analyze the interaction of carbon monoxide with the TiC(001) surfaces, both perfect and containing carbon vacancies. CO exhibits a similar ${\sigma}$-donation interaction for both $Ti_{25}C_{25}$ and $Ti_{25}C_{23}$ clusters, as deduced from the fact that the populations of the CO $5{\sigma}$ orbital are identical upon adsorption, but it bonds more strongly with the $Ti_{25}C_{23}$ than with the $Ti_{25}C_{25}$ because the metal d electron density in $Ti_{25}C_{23}$ provides ${\pi}$ back-bonding interactions with CO that are absent in $Ti_{25}C_{25}$. This work suggests that a difference in reactivity toward CO of stoichiometric TiC and TiC with carbon defects is connected with the occupancy of $2{\pi}^*$ orbitals that leads to a significant weakening of the C-O bond.

Ti-6Al-4V 합금의 절삭특성과 FEM 해석 비교에 관한 연구 (A Study on the Cutting Characteristics and Analysis by a FEM in the Machining of Ti-6Al-4V alloy)

  • 김남용;홍우표;이동주
    • 한국공작기계학회논문집
    • /
    • 제10권6호
    • /
    • pp.29-35
    • /
    • 2001
  • The cutting characteristics of Ti-6Al-4V alloy and total wear when machining Ti-6Al-4V alloy was studied to understand the machining characteristics. This material is one of the strong candidate materials present and future aerospace or met ical applications. Nowadays their usage has already been broaden to commercial applications such as golf club head, finger rings and many decorative items. Anticipating the general use of this material and development of the titanium alloy in domestic facilities, the review and the study of the machining parameters far those alloys are deemed necessary. This study is concentrated to the machining parameters of the Ti-6Al-4V alloy due to their dominant position in the production of tita mum alloys.

  • PDF

Large Scale Production of Nanoparticles by Laser Pyrolysis

  • Tenegal, Francois;Guizard, Benoit;Reau, Adrien;Ye, Chang;Boulanger, Loic;Giraud, Sophie;Canel, Jerome
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.150-151
    • /
    • 2006
  • Laser pyrolysis is a very suitable method for the synthesis of a wide range of nanoparticles. A pilot unit based on this process has been recently developed at CEA. This paper reports results showing the possibility to produce SiC and $TiO_2$ nanoparticles at rates of respectively 1 and 0.2 kg/h and also the possibility to adjust the mean grain size of the particles and their structure by changing the laser intensity and reactants flow rates. First tests of liquid recovery have been also successfully performed to limit the risks of nanoparticles dissemination in the environement during their recovery.

  • PDF

정전기적 자가결합법으로 제조된 2차원 티타늄 카바이드(MXene)/실리콘 음극 복합소재의 전기화학적 특성 (Electrochemical Characteristics of 2-Dimensional Titanium Carbide(MXene)/Silicon Anode Composite Prepared by Electrostatic Self-assembly)

  • 김동민;이종대
    • Korean Chemical Engineering Research
    • /
    • 제62권3호
    • /
    • pp.262-268
    • /
    • 2024
  • 본 연구에서는 고성능 리튬이온전지용 음극 소재로써 2차원 구조의 티타늄 카바이드(MXene)와 나노 실리콘의 정전기적 결합을 통한 MXene/Si 음극 복합소재를 제조하였다. LiF/HCl을 이용하여 Ti3AlC2 MAX를 에칭해 Ti3C2Tx MXene을 제조하였으며, 정전기적 결합을 형성하기 위해 나노 실리콘의 표면을 CTAB (Cetyltrimethylammonium bromide)을 활용하여 양전하로 대전하였다. MXene/Si 음극 복합소재는 제조된 MXene과 대전 된 실리콘의 간단한 혼합 공정을 통해 성공적으로 제조되었다. 제조된 복합소재의 물리적 특성과 전기화학적 특성을 MXene과 실리콘의 조성비에 따라 조사하였으며, 전극의 안정성을 평가하기 위해 충·방전 사이클 후의 전극 표면을 분석하였다. MXene/Si 복합소재는 MXene 대비 실리콘 조성 비율이 2, 3 및 4로 증가할수록 1962.9, 2395.2 및 2504.3 mAh/g의 높은 초기 방전용량을 나타내었다. MXene과 실리콘 조성비가 1 : 4인 MXene/Si-4는 100 사이클에서 1387.5 mAh/g의 가역 용량과 74.5%의 용량 유지율을 나타내었으며, 4.0 C의 높은 율속에서도 700.5 mAh/g으로 높은 용량을 발현하였다. 이러한 결과를 통해 정전기적 결합으로 제조된 MXene/Si 복합소재는 고성능 리튬이온배터리용 음극소재로 적용 될 수 있다.

SiO2/TiO2 혼합입자 슬러리 SiC CMP의 재료제거율 모델링 (Material Removal Rate Modeling of SiO2/TiO2 Mixed-Abrasive Slurry CMP for SiC)

  • 이현섭
    • Tribology and Lubricants
    • /
    • 제39권2호
    • /
    • pp.72-75
    • /
    • 2023
  • Silicon carbide (SiC) is used as a substrate material for power semiconductors; however, SiC chemical mechanical polishing (CMP) requires considerable time owing to its chemical stability and high hardness. Therefore, researchers are attempting to increase the material removal rate (MRR) of SiC CMP using various methods. Mixed-abrasive CMP (MAS CMP) is one method of increasing the material removal efficiency of CMP by mixing two or more particles. The aim of this research is to study the mathematical modeling of the MRR of MAS CMP of SiC with SiO2 and TiO2 particles. With a total particle concentration of 32 wt, using 80-nm SiO2 particles and 25-nm TiO2 particles maximizes the MRR at 8 wt of the TiO2 particle concentration. In the case of 5 nm TiO2 particles, the MRR tends to increase with an increase in TiO2 concentration. In the case of particle size 10-25 nm TiO2, as the particle concentration increases, the MRR increases to a certain level and then decreases again. TiO2 particles of 25 nm or more continuously decreased MRR as the particle concentration increased. In the model proposed in this study, the MRR of MAS CMP of SiC increases linearly with changes in pressure and relative speed, which shows the same result as the Preston's equation. These results can contribute to the future design of MAS; however, the model needs to be verified and improved in future experiments.

티타늄강화 차폐막의 골유도 재생 효과 (Osteopromotive effect of Titanium Reinforced-ePTFE membrane)

  • 이진;권영혁;박준봉;허익;정종혁;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제34권4호
    • /
    • pp.711-722
    • /
    • 2004
  • The purpose of this study is to evaluate the regenerated bone histollogically using titanium reinforced ePTFE(TR-ePTFE) membrane and to investigate cell occlusiveness, wound stabilization and tissue integration of TR-ePTFE membrane. Adult male rabbits (mean BW 2kg) and TR9W (W.L.Gore&Associate.INC,USA) were used in this study. Intramarrow penetration defects were surgically created with round carbide bur(HP long #6) on calvaria of rabbits. TR-ePTFE membrane was applied to defect. Then guided bone regeneration was carried out using TR-ePTFE membrane and resorbable suture. At 2,4,8,12 weeks after the surgery, animals were sacrificed. Nondecalcified specimens were processed for histologic analysis. The result and conclusion of this study were as follows: 1. TR-ePTFE membrane had good ability of biocompatibility and cell occlusiveness. 2. space making for guided bone regenerayion was good at TR-ePTFE membrane. 3. Tissue integration was not good at TR-ePTFE membrane. So, wound stabilization was not good. 4. At 8 weeks, 12 weeks after GBR procedure, bone formation was seen. From the above results, TR-ePTFE membrane fixed tightiy on alveolar bone might be recommended for the early bone formation.

TiC, TiN과 TiC/TiN 코팅의 트라이볼로지 특성 (Tribological Characteristics of TiC, TiN and TiC/TiN Coatings)

  • 전찬열
    • 한국산학기술학회논문지
    • /
    • 제15권3호
    • /
    • pp.1253-1258
    • /
    • 2014
  • CA 이온도금기술에 의한 TiC와 TiN 그리고 TiC/TiN 코팅재를 비교하기 위하여 트라이볼로지 물성을 연구하였다. 실험은 Falex journal V block 시스템을 이용한 터보시험기에서 수행하였다. 코팅재의 마찰과 마모특성은 작용된 하중과 미끄럼 속도에 의하여 다양하게 결정되었다. TiC와 TiN 그리고 TiC/TiN 코팅재는 표면에서 트라이볼로지 특성이 현저하게 증가하였다. 단층코팅에서는 TiC보다 TiN이 좋은 결과를 얻었다. 그러나, TiC/TiN의 다층코팅은 다른 어떤 단층코팅보다 좋은 성능을 보였다. 다층코팅의 성능이 향상된 핵심요소는 TiN층 외부와 강 사이에서 부착이 증가하게된 TiC의 역할 때문이다.

Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

  • Jo, Jae-Young;Yang, Dong-Seok;Huh, Jung-Bo;Heo, Jae-Chan;Yun, Mi-Jung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.491-497
    • /
    • 2014
  • PURPOSE. This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. RESULTS. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). CONCLUSION. The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중에 미치는 영향에 관한 연구 (INFLUENCE OF TUNGSTEN CARBIDE/CARBON COATING ON THE PRELOAD OF IMPLANT ABUTMENT SCREWS)

  • 최진욱;정창모;전영찬;임장섭;정희찬;엄태관
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.229-242
    • /
    • 2006
  • Statement of problem: In order to increase preload with reducing the friction coefficient, abutment screws coated with pure gold and Teflon as dry lubricant coatings have been introduced. But the reported data indicate that if screw repeated tightening and loosening cycle, an efficiency of increasing preload was decreased by screw surface wearing off. Purpose: This study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on the preload of abutment screws and the stability of coating surface after repeated closures. Material and method: The rotational values of abutment screws and the compressive forces between abutment and fixture were measured in implant systems with three different joint connections, one external butt joint and two internal cones. Moreover the stability and the alteration of coating surface were examined by comparison of the compressive force and the removable torque values during 10 consecutive trials, observation with scanning electron microscope and analyzed the elemental composition with energy dispersive x-ray spectroscopy Results and conclusion: 1. Application of coating resulted in significant increase of compressive force in all implant systems(P<.05). The increasing rate of compressive force by coating in external butt joint was gloater than those in internal cones (P<.05). 2. Coated screw showed the significant additional rotation compared to non-coated screw in all implant systems (P<.05). There were no significant differences in the increasing rate of rotation among implant systems (P>.05). 3. Removable torque values were greater with non-coated screw than that with coated screw (P<.05). 4. Coated screw showed insignificant variations in the compressive forces during 10 consecutive trials(P>.05) 5. After repeated trials, the surface layer of coated screw was maintained relatively well. However surface wearing and irregular titanium fragments were found in non-coated screw.