• 제목/요약/키워드: Titanium and Titanium oxide

검색결과 529건 처리시간 0.025초

티타늄나노입자의 랫드 5일 반복 경구투여 후 배설, 조직분포 및 독성에 관한 평가연구 (Excretion, Tissue Distribution and Toxicities of Titanium Oxide Nanoparticles in Rats after Oral Administration over Five Consecutive Days)

  • 김혜진;박광식
    • 한국환경보건학회지
    • /
    • 제40권4호
    • /
    • pp.294-303
    • /
    • 2014
  • Objectives: Excretion and tissue distribution of titanium oxide nanoparticles were evaluated in rats after oral administration. The relation between toxicity and systemic concentration of nanoparaticles was investigated. Methods: Rats were orally treated with titanium oxide nanoparticles (10, 100 mg/kg) for five consecutive days. General toxicity, blood chemistry, and serum biochemical analysis were analyzed. Titanium concentration in liver, kidney, lung, urine and feces were measured and histopathology was performed in these organs. Results: Induction of toxicological parameters was not observed and titanium nanoparticles were excreted via feces. Conclusion: Absorption of titanium oxide nanoparticles via the gastrointestinal tract after oral administration was very poor and systemic concentration of titanium oxide nanoparticles was not elevated. Titanium oxide nanoparticles did not cause toxicities in rats after oral administration.

양극산화 티타늄의 생체적합성에 관한 연구 (A Study on the Biocompatibility of Anodized Titanium)

  • 이민호;추용호
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권4호
    • /
    • pp.333-340
    • /
    • 1993
  • The high biocompatibility of titanium is connected with the high corrosion resistance of the surface oxide, its high dielectric constant, and some other specific biochemical properties of the oxide. The corrosion resistance of titanium can be improved with the formation of passive film by anodic oxidation. In other to characterize the titantium oxlde film formed by anodic oxidation, titanium plates were anodized in 0.5M $H_3SO_4$ electrolyte at voltages between 5V and 100v. The oxide film was examined by an X-Ray Diffractometer(XRD) and a Scanning Electron Microscope(SEM). In addition, the corrosion resistance of oxide film was tested by dipping in physiological NaCl,5% HCI,5% $H_3PO_4$ and its biocompatability was evaluated by the fibroblast-like cell culture. The results obtained are as follows : 1. The thickness of surface oxide and micropore are increased with the increase of electrode potential and formed deeply along the grain boundary. 2. The solubilities of titanium in electrolyte solution shows that the anodized titanium has more corrosion resistance than the untreated pure titanium. 3. The biocomatibility of anodized titanium is superior to untreated pure titanium.

  • PDF

분무건조법에 의해 제조된 Ti-Co-O계 산화물 분말의 환원/침탄반응에 미치는 코발트 산화물의 영향 (Effect of Cobalt Oxide on Carbothermal Reduction of Spray Dried Titanium-Cobalt-Oxygen Based Oxide Powder)

  • 이길근;김찬영
    • 한국분말재료학회지
    • /
    • 제12권5호
    • /
    • pp.336-344
    • /
    • 2005
  • In the present study, the focus is on the effect of cobalt oxide powder in the carbothermal reduction of the titanium-cobalt-oxygen based oxide powder by solid carbon for the optimizing synthesis process of ultra fine TiC/Co composite powder. The titanium-cobalt-oxygen based oxide powder was prepared by the combination of the spray drying and desalting processes using the titanium dioxide powder and cobalt nitrate as the raw materials. The titanium-cobalt-oxygen based oxide powder was mixed with carbon black, and then this mixture was carbothermally reduced under flowing argon atmosphere. Changes in the phase structure and thermal gravity of the mixture during carbothermal reduction were analysed using XRD and TGA. Titanium-cobalt-oxygen based oxide powder desalted at $600^{\circ}C$ had a mixture of $TiO_2\;and\;Co_{3}O_4$. And the one desalted at $800^{\circ}C$ had a mixture of $TiO_2\;and\;CoTiO_3$. In the case of the former powder, the reduction of cobalt oxide powder in the titanium-cobalt-oxygen based oxide powder occurred at lower temperature than the latter one. However, the carbothermal reduction of titanium dioxide powder in the titanium-cobalt-oxygen based oxide powder with a mixture of $TiO_2\;and\;Co_{3}O_4$ occurred at higher temperature than the one with a mixture of $TiO_2\;and\;CoTiO_3$. And also, the former powder showed a lower TiC formation ability than the latter one.

노즐 형태 HCP RT-MOCVD에 의해 증착된 티타늄 산화막 특성 (The Characteristics of Titanium Oxide Films Deposited by the Nozzle-type HCP RT-MOCVD)

  • 정일현
    • 공업화학
    • /
    • 제17권2호
    • /
    • pp.194-200
    • /
    • 2006
  • 금속 산화막 공정에 응용하기 위하여 노즐형태 HCP (hollow cathode plasma) RT-MOCVD에 의해 티타늄 산화막을 증착하였다. TTNB (titanium n-butoxide)를 사용하였을 경우 막을 증착한 후 열처리하여야 하지만 titanium ethoxide에 의해 막을 증착하면 일반적으로 수반되는 열처리 공정을 생략하여도 티타늄 산화막이 직접적으로 형성되었다. RF-power 240 watt, 전극과 기판과의 거리가 3 cm, 반응시간 20 min, Ar와 $O_2$의 유량비 1 : 1에서 티타늄과 산소의 조성비가 1 : 2임을 확인할 수 있었다. 따라서 노즐형태 HCP RT-MOCVD에 의해 티타늄 산화막을 열처리 공정 없이 증착되었으며, 저온에서 다양한 금속 산화막 증착 공정에 응용할 수 있었다.

Surface Modification of Titanium Based Biomaterials by Ion Beam

  • Liu, Xianghuai;Huang, Nan;Yang, Ping;Cai, Guanjun;Chen, Yuanru;Zheng, Zhi hong;Zhou, Zhuyao
    • 한국진공학회지
    • /
    • 제4권S2호
    • /
    • pp.8-19
    • /
    • 1995
  • Ion beam enhanced deopsition(IBED) was adopted to synthesize biocompatible titanium oxide film. Structure characteristics of titanium oxide film were investigated by RBS, AES and XRD. The blood compatibility of the titanium oxide film was studied by measurements of blood clotting time and platelet adhesion. The results show that the anticoagulation property of titanium oxide film is improved significantly. The mechanism of anticoagulation of the titanium oxide film was discussed.

  • PDF

Characteristics of a Titanium-oxide Layer Prepared by Plasma Electrolytic Oxidation for Hydrogen-ion Sensing

  • Lee, Do Kyung;Hwang, Deok Rok;Sohn, Young-Soo
    • 센서학회지
    • /
    • 제28권2호
    • /
    • pp.76-80
    • /
    • 2019
  • The characteristics of a titanium oxide layer prepared using a plasma electrolytic oxidation (PEO) process were investigated, using an extended gate ion sensitive field effect transistor (EG-ISFET) to confirm the layer's capability to react with hydrogen ions. The surface morphology and element distribution of the PEO-processed titanium oxide were observed and analyzed using field-emission scanning-electron microscopy (FE-SEM) and energy-distribution spectroscopy (EDS). The titanium oxide prepared by the PEO process was utilized as a hydrogen-ion sensing membrane and an extended gate insulator. A commercially available n-channel enhancement MOS-FET (metal-oxide-semiconductor FET) played a role as a transducer. The responses of the PEO-processed titanium oxide to different pH solutions were analyzed. The output drain current was linearly related to the pH solutions in the range of pH 4 to pH 12. It was confirmed that the titanium-oxide layer prepared by the PEO process could feasibly be used as a hydrogen-ion-sensing membrane for EGFET measurements.

Nano-engineering of Hybrid Titanium Oxide Structure (TiO2) using Pore-widening Concentration for Enhanced Superhydrophilicity

  • Yeji Choi;Chanyoung Jeong
    • Corrosion Science and Technology
    • /
    • 제23권1호
    • /
    • pp.41-53
    • /
    • 2024
  • Titanium alloy is gaining attention in the medical industry due to its excellent biocompatibility and osteoconductivity. However, the natural oxide film on the titanium surface is insoluble, resulting in inadequate bone adhesion. Therefore, it is necessary to optimize the contact between biological tissues and implant surfaces, and alter the chemical composition and morphological characteristics of the implant surface. In this study, the anodization method was applied to titanium surface treatment to form a uniform and robust oxide film. Subsequently, a chemical process, pore-widening, was employed to change the morphological characteristics of the oxide film. The concentration of the pore-widening solution was varied at 2, 4, 6, and 8 wt% and the process time was set at 30 and 60 minutes. As the concentration of the pore-widening solution increased the pore diameter of the oxide film increased. Notably, at 6 wt% for 60 minutes, the oxide film exhibited a coexistence of pillars and pores. Based on this, it was determined that surface roughness increased with higher concentration and longer process time. Additionally, the presence of pillars and pores structures maximized hydrophilicity. This study provides insights into enhancing the surface properties of titanium for improved performance in medical implants.

분무건조법에 의해 제조된 Ti-Co-O계 산화물 분말의 고체 탄소에 의한 환원/침탄 (Carbothermal Reduction of Spray Dried Titanium-Cobalt-Oxygen Based Oxide Powder by Solid Carbon)

  • 이길근;문창민;김병기
    • 한국분말재료학회지
    • /
    • 제11권1호
    • /
    • pp.28-33
    • /
    • 2004
  • In the present study, the focus is on the analysis of carbothermal reduction of the titanium-cobalt-oxygen based oxide powder by solid carbon for the optimizing synthesis process of ultra fined TiC/Co composite powder. The titanium-cobalt-oxygen based oxide powder was prepared by the combination of the spray drying and desalting processes using the titanium dioxide powder and cobalt nitrate as the raw materials. The titanium-cobalt-oxygen based oxide powder was mixed with carbon black, and then this mixture was carbothermally reduced under a flowing argon atmosphere. The changes in the phase structure and thermal gravity of the mixture during carbothermal reduction were analysed using XRD and TGA. The synthesized titanium-cobalt-oxygen based oxide powder has a mixture of $TiO_2$ and $CoTiO_3$. This oxide powder was transformed to a mixed state of titanium car-bide and cobalt by solid carbon through four steps of carbothermal reduction steps with increasing temperature; reduction of $CoTiO_3$ to $TiO_2$ and Co, reduction of $TiO_2$, to the magneli phase($Ti_nO_{2n-1}$, n>3), reduction of the mag-neli phase($Ti_nO_{2n-1}$, n>3) to the $Ti_nO_{2n-1}$(2$\leq$n$\leq$3) phases, and reduction and carburization of the $Ti_nO_{2n-1}$(2$\leq$n$\leq$3) phases to titanium carbide.

Titanium Oxide Film : A New Biomaterial For Artificial Heart Valve Prepared by Ion Beam Enhanced Deposition

  • Liu, Xianghuai;Zhang, Feng;Zheng, Zhihong;Huang, Nan
    • 한국진공학회지
    • /
    • 제6권S1호
    • /
    • pp.1-15
    • /
    • 1997
  • Titanium oxide films were prepared by ion beam enhanced deposition where the films were synthesized by deposition titianium atoms and simultaneously bombarding with xenon ion beam at an energy of 40 keV in an $O_2$ environ,ent. Structure and composition of titanium oxide films were investigated by X-ray Doffractopm (XRD) Ritjerfprd Backscattering Spectroscopy (RBS) and X-ray Diffraction(XRD) Rutherford Backscattering Spectroscopy (RBS) and X-ray photoelectron spectroscopy (XPS) The results show that thestructure of the prepared films exhibit a rutile phase structure wit high(200) orientation and the O/Ti ratio of the titanium oxide films was about 2:1 XPS anlysis shows that $Ti^{2+},Ti^{3+}\;and\;Ti^{4+}$ chemical states exist on the titanium oxide films. the blood compatibility of the titanium oxide films was studied by measurements of blood clotting time and platelet adhesion. The results show that the anticoagulation property of titanium oxide films improved significantly and better than that of LTI-carbon which was widely used to fabricate artificial heart valve.

  • PDF

Effect of Titanium Surface Treatments Bond Strength and Cytotoxicity in Titanium-Porcelain System

  • 정인성
    • 대한의생명과학회지
    • /
    • 제14권2호
    • /
    • pp.105-113
    • /
    • 2008
  • The objective of this study was to evaluate the influence of surface modifications on the bonding characteristics and cytotoxicity of specific titanium porcelain bonded to milling titanium and cast titanium. Milling titanium and cast titanium samples were divided into 8 test groups. These groups are as follow: i) sandblasted with particles of different size of $220{\mu}m\;and\;50{\mu}m$, ii) different sequences of sandblasting treatment and etching treatment, iii) etched with different etching solutions, and iv) preheated or not. The surface characteristics of specimens were characterized by the test of mean roughness of surface and SEM. The bond strength of titanium-ceramic systems was measured by using three-point bending test and SEM. The results show that the mean roughness of surface of sample sandblasted with $220{\mu}m$ aluminum oxide increased and bond strength were higher than sample sandblasted with $50{\mu}m$ aluminum oxide. The mean roughness of surface decreased, but the bond strength increased when the samples sandblasted with $220{\mu}m$ aluminum oxide were preheated. The sample sandblasted with $220{\mu}m$ aluminum oxide after oxidized with occupational corrosive agent I (50% NaOH, 10% $CuSO_4{\cdot}5H_2O$) and II (35% $HNO_3$, 5% HF) showed higher bond strength than sample oxidized with 30% $HNO_3$ after sandblasted with $220{\mu}m$ aluminum oxide. Group NaCuNF220SP (milling Ti: 35.3985 MPa, casting Ti: 37.2306 MPa) which was treated with occupational corrosive agent I (50% NaOH, 10% $CuSO_4{\cdot}5H_2O$) and II (35% $HNO_3$, 5% HF), followed by sandblasting with $220{\mu}m$ aluminum oxide and preheating at $750^{\circ}C$ for 1 hour showed the highest bond strength and significant differences (P<0.05). The method for modifying surface of titanium showed excellent stability of cells.

  • PDF