• Title/Summary/Keyword: Tissue expanders

Search Result 27, Processing Time 0.02 seconds

Scarred scalp reconstruction with a rectangular expander

  • Shin, Hyojeong;Shin, Jeonghwan;Lee, Jun Yong
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.3
    • /
    • pp.184-187
    • /
    • 2020
  • Scalp reconstruction is challenging because the scalp is inelastic, stiff, and has hair follicles. Tissue expansion offers aesthetically pleasing outcomes with minimal donor-site morbidity. However, in a scarred scalp, the extent of possible dissection for the expander insertion may be limited and surgeons must make use of the limited scalp tissue. We successfully reconstructed scarred scalps using rectangular expanders. This report presents two cases: a 4×3 cm chronic defect with widespread scarring and osteomyelitis and an 11×7.5 cm scar tissue following a skin graft. Tissue expanders were inserted in the subgaleal plane and were inflated by 195 mL and 400 mL over periods of 2 and 3 months, respectively. Subgaleal elevation of a fasciocutaneous flap was achieved with the expanded tissue. The defects were well covered, with good color, texture, and hair-bearing tissue. There were no complications involving the tissue expanders. Rectangular expanders yield more available tissue than round or crescent-shaped expanders. Moreover, since the base of the flap is well defined, the expander can be easily inserted in a limited space. Therefore, rectangular expanders are recommended for the reconstruction of scarred scalps.

Characteristics of adhesion areas between the tissue expander and capsule in implant-based breast reconstruction

  • Lim, Yoon Min;Park, Kwang Hyun;Lee, Dong Won;Lew, Dae Hyun;Roh, Tai Suk;Song, Seung Yong
    • Archives of Plastic Surgery
    • /
    • v.46 no.4
    • /
    • pp.330-335
    • /
    • 2019
  • Background The use of anatomic implants has improved the aesthetic results of breast surgery; however, implant malrotation is an uncommon, but serious complication of these procedures. Nevertheless, little research has explored implant adhesion. In this study, we investigated adhesion between the expander and the capsule. Methods Seventy-nine cases of immediate breast reconstruction via two-stage implant-based reconstruction performed between September 2016 and November 2017 were evaluated. Mentor CPX4 expanders were used in 14 breasts, and Natrelle expanders in 65. We analyzed areas of adhesion on the surfaces of the tissue expanders when they were exchanged with permanent implants. We investigated whether adhesions occurred on the cephalic, caudal, anterior, and/or posterior surfaces of the expanders. Results Total adhesion occurred in 18 cases, non-adhesion in 15 cases, and partial adhesion in 46 cases. Of the non-adhesion cases, 80% (n=12) were with Mentor CPX4 expanders, while 94.4% (n=17) of the total adhesion cases were with Natrelle expanders. Of the partial adhesion cases, 90.7% involved the anterior-cephalic surface. The type of tissue expander showed a statistically significant relationship with the number of attachments in both univariate and multivariate logistic regression analyses (P<0.001) and with total drainage only in the univariate analysis (P=0.015). Conclusions We sought to identify the location(s) of adhesion after tissue expander insertion. The texture of the implant was a significant predictor of the success of adhesion, and partial adhesion was common. The anterior-cephalic surface showed the highest adhesion rate. Nevertheless, partial adhesion suffices to prevent unwanted rotation of the expander.

Tabbed Tissue Expanders Improve Breast Symmetry Scores in Breast Reconstruction

  • Khavanin, Nima;Gust, Madeleine J.;Grant, David W.;Nguyen, Khang T.;Kim, John Y.S.
    • Archives of Plastic Surgery
    • /
    • v.41 no.1
    • /
    • pp.57-62
    • /
    • 2014
  • Background Achieving symmetry is a key goal in breast reconstruction. Anatomically shaped tabbed expanders are a new tool in the armamentarium of the breast reconstruction surgeon. Suture tabs allow for full control over the expander position and thus inframammary fold position, and, in theory, tabbed expanders mitigate many factors responsible for poor symmetry. The impact of a tabbed expander on breast symmetry, however, has not been formally reported. This study aims to evaluate breast symmetry following expander-implant reconstruction using tabbed and non-tabbed tissue expanders. Methods A chart review was performed of 188 consecutive expander-implant reconstructions that met the inclusion criteria of adequate follow-up data and postoperative photographs. Demographic, oncologic, postoperative complication, and photographic data was obtained for each patient. The photographic data was scored using a 4-point scale assessing breast symmetry by three blinded, independent reviewers. Results Of the 188 patients, 74 underwent reconstruction with tabbed expanders and 114 with non-tabbed expanders. The tabbed cohort had significantly higher symmetry scores than the non-tabbed cohort ($2.82/4{\pm}0.86$ vs. $2.55/4{\pm}0.92$, P=0.034). Conclusions The use of tabbed tissue expanders improves breast symmetry in tissue expander-implant-based breast reconstruction. Fixation of the expander to the chest wall allows for more precise control over its location and counteracts the day-to-day translational forces that may influence the shape and location of the expander pocket, mitigating many factors responsible for breast asymmetry.

Oral tissue response to soft tissue expanders prior to bone augmentation: in vitro analysis and histological study in dogs

  • Yoo, Jung Min;Amara, Heithem Ben;Kim, Min Kyoung;Song, Ju Dong;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.3
    • /
    • pp.152-163
    • /
    • 2018
  • Purpose: To determine whether the swelling and mechanical properties of osmotic self-inflating expanders allow or not the induction of intraoral soft tissue expansion in dogs. Methods: Three different volumes (0.15, 0.25, and 0.42 mL; referred to respectively as the S, M, and L groups) of soft tissue expanders (STEs) consisting of a hydrogel core coated with a silicone-perforated membrane were investigated in vitro to assess their swelling behavior (volume swelling ratio) and mechanical properties (tensile strength, tensile strain). For in vivo investigations, the STEs were subperiosteally inserted for 4 weeks in dogs (n=5). Soft tissue expansion was clinically monitored. Histological analyses included the examination of alveolar bone underneath the expanders and thickness measurements of the surrounding fibrous capsule. Results: The volume swelling ratio of all STEs did not exceed 5.2. In tensile mode, the highest mean strain was registered for the L group ($98.03{\pm}0.3g/cm$), whereas the lowest mean value was obtained in the S group ($81.3{\pm}0.1g/cm$), which was a statistically significant difference (P<0.05). In addition, the S and L groups were significantly different in terms of tensile strength ($1.5{\pm}0.1g/cm$ for the S group and $2.2{\pm}0.1g/cm$ for the L group, P<0.05). Clinical monitoring showed successful dilatation of the soft tissues without signs of inflammation up to 28 days. The STEs remained volumetrically stable, with a mean diameter in vivo of 6.98 mm, close to the in vitro post-expansion findings (6.69 mm). Significant histological effects included highly vascularized collagen-rich fibrous encapsulation of the STEs, with a mean thickness of $0.67{\pm}0.12mm$. The bone reaction consisted of resorption underneath the STEs, while apposition was observed at their edges. Conclusions: The swelling and mechanical properties of the STEs enabled clinically successful soft tissue expansion. A tissue reaction consisting of fibrous capsule formation and bone loss were the main histological events.

Surgical Treatment of Postpneumonectomy Syndrome with Tissue Expanders in Children

  • Jung, Hee Suk;Suh, Jee Won;Kim, Tae Hoon;Lee, Chang Young;Chung, Kyung Young
    • Journal of Chest Surgery
    • /
    • v.48 no.3
    • /
    • pp.217-219
    • /
    • 2015
  • Postpneumonectomy syndrome (PPS) is a rare late complication of pneumonectomy. It occurs more often in children than in adults, and is characterized by respiratory failure resulting from bronchial compression caused by severe mediastinal shift. Various methods have been used to treat PPS, including aortopexy and the insertion of plastic balls, silastic implants, and saline-filled breast prostheses. We describe two cases of PPS corrected with tissue expanders after right pneumonectomy in patients with esophageal atresia.

Assessment of Temporary Radioactivation for Tissue Expanders in Breast Radiation Therapy: Preliminary Study

  • Hwajung Lee;Do Hoon Oh;Lee Yoo;Minsoo Chun
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.2
    • /
    • pp.100-106
    • /
    • 2023
  • Background: As breast tissue expanders consist of metallic materials in the needle guard and ferromagnetic injection port, irradiation can produce radioactivation. Materials and Methods: A CPX4 (Mentor Worldwide LLD) breast tissue expander was exposed using the Versa HD (Elekta) linear accelerator. Two photon energies of 6 and 10 MV-flattening filter free (FFF) beams with 5,000 monitor units (MU) were irradiated to identify the types of radiation. Furthermore, 300 MU with 10 MV-FFF beam was exposed to the CPX4 breast tissue expander by varying the machine dose rates (MDRs) 600, 1,200, and 2,200 MU/min. To assess the instantaneous dose rates (IDRs) solely from the CPX4, a tissue expander was placed outside the treatment room after beam irradiation, and a portable radioisotope identification device was used to identify the types of radiation and measure IDR. Results and Discussion: After 5,000 MU delivery to the CPX4 breast tissue expander, the energy spectrum whose peak energy of 511 keV was found with 10 MV-FFF, while there was no resultant one with 6 MV-FFF. The time of each measurement was 1 minute, and the mean IDRs from the 10 MV-FFF were 0.407, 0.231, and 0.180 μSv/hr for the three successive measurements. Following 10 MV-FFF beam irradiation with 300 MU indicated around the background level from the first measurement regardless of MDRs. Conclusion: As each institute room entry time protocol varies according to the working hours and occupational doses, we suggest an addition of 1 minute from the institutes' own room entry time protocol in patients with CPX4 tissue expander and the case of radiotherapy vaults equipped with a maximum energy of 10 MV photon beams.

Multifactorial analysis of the surgical outcomes of giant congenital melanocytic nevi: Single versus serial tissue expansion

  • Kim, Min Ji;Lee, Dong Hwan;Park, Dong Ha
    • Archives of Plastic Surgery
    • /
    • v.47 no.6
    • /
    • pp.551-558
    • /
    • 2020
  • Background Giant congenital melanocytic nevus (GCMN) is a rare disease, for which complete surgical resection is recommended. However, the size of the lesions presents problems for the management of the condition. The most popular approach is to use a tissue expander; however, single-stage expansion in reconstructive surgery for GCMN cannot always address the entire defect. Few reports have compared tissue expansion techniques. The present study compared single and serial expansion to analyze the risk factors for complications and the surgical outcomes of the two techniques. Methods We retrospectively reviewed the medical charts of patients who underwent tissue expander reconstruction between March 2011 and July 2019. Serial expansion was indicated in cases of anatomically obvious defects after the first expansion, limited skin expansion with two more expander insertions, or capsular contracture after removal of the first expander. Results Fifty-five patients (88 cases) were analyzed, of whom 31 underwent serial expansion. The number of expanders inserted was higher in the serial-expansion group (P<0.001). The back and lower extremities were the most common locations for single and serial expansion, respectively (P =0.043). Multivariate analysis showed that sex (odds ratio [OR], 0.257; P=0.015), expander size (OR, 1.016; P=0.015), and inflation volume (OR, 0.987; P=0.015) were risk factors for complications. Conclusions Serial expansion is a good option for GCMN management. We demonstrated that large-sized expanders and large inflation volumes can lead to complications, and therefore require risk-reducing strategies. Nonetheless, serial expansion with proper management is appropriate for certain patients and can provide aesthetically satisfactory outcomes.

New economical and simple device for intraoperative expansion on small and medium sized soft tissue defects

  • Lee, Jun Won;Park, Seong Hoon;Lee, Seong Joo;Kim, Seong Hwan;Jeong, Hii Sun;Suh, In Suck
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.3
    • /
    • pp.235-239
    • /
    • 2018
  • Intraoperative expansion has been used to cover small to large defects without disadvantages of the conventional tissue expanders. Various materials, for example, expanders and Foley catheters are being used. We introduce a new, convenient and economical device immediately available in the operating room, according to the defect size for intraoperative expansion, with latex gloves or balloons. The retrospective study was done with 20 patients who presented with skin and soft tissue defects. During the operation, expansion was done with latex gloves or balloons inflated with saline through an intravenous line and a three-way stopcock. After the inflation, the glove was removed and skin was covered with expanded tissue. A careful decision was made regarding the inflation volume and placement of the expander according to the defect size. There were no postoperative complications. The skin contracture and tension was minimal with a texture similar to the adjacent tissue. The new intraoperative expansion devices with latex gloves and balloons were cheap and made easily right in the operation room. The reconstruction of small to large sized skin defects can be done successfully, functionally and aesthetically without using expensive commercial materials.

Midfacial soft tissue changes after maxillary expansion using micro-implant-supported maxillary skeletal expanders in young adults: A retrospective study

  • Nguyen, Hieu;Shin, Jeong Won;Giap, Hai-Van;Kim, Ki Beom;Chae, Hwa Sung;Kim, Young Ho;Choi, Hae Won
    • The korean journal of orthodontics
    • /
    • v.51 no.3
    • /
    • pp.145-156
    • /
    • 2021
  • Objective: The aim of this retrospective study was to assess the midfacial soft tissue changes following maxillary expansion using micro-implant-supported maxillary skeletal expanders (MSEs) in young adults by cone-beam computerized tomography (CBCT) and to evaluate the correlations between hard and soft tissue changes after MSE usage. Methods: Twenty patients (mean age, 22.4 years; range, 17.6-27.1) with maxillary transverse deficiency treated with MSEs were selected. Mean expansion amount was 6.5 mm. CBCT images taken before and after expansion were superimposed to measure the changes in soft and hard tissue landmarks. Statistical analyses were performed using paired t-test and Pearson's correlation analysis on the basis of the normality of data. Results: Average lateral movement of the cheek points was 1.35 mm (right) and 1.08 mm (left), and that of the alar curvature points was 1.03 mm (right) and 1.02 mm (left). Average forward displacement of the cheek points was 0.59 mm (right) and 0.44 mm (left), and that of the alar curvature points was 0.61 mm (right) and 0.77 mm (left) (p < 0.05). Anterior nasal spine (ANS), posterior nasal spine (PNS), and alveolar bone width showed significant increments (p < 0.05). Changes in the cheek and alar curvature points on both sides significantly correlated with hard tissue changes (p < 0.05). Conclusions: Maxillary expansion using MSEs resulted in significant lateral and forward movements of the soft tissues of cheek and alar curvature points on both sides in young adults and correlated with the maxillary suture opening at the ANS and PNS.

Serially expanded flap use to treat large hairless scalp lesions

  • Shin, Dongwoo;Kim, Yong Hun;Song, Han Gyeol;Hong, Jong Won
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.6
    • /
    • pp.408-411
    • /
    • 2019
  • Hairless scalp areas can occur due to trauma, tumors, or congenital disease. This aesthetically unpleasing condition can lead to psychosocial distress, and thin skin flaps may be prone to scarring. Treating the hairless scalp by simple excision is challenging because of skin tension. Tissue expanders are a good option for hairless scalp resurfacing. However, a single expansion may be inadequate to cover the entire defect. This report describes good results obtained using a serial resurfacing method involving re-expansion of the flap with a tissue expander to treat two patients with large lesions: one due to aplasia cutis congenital and another who underwent dermatofibrosarcoma protuberance resection. The results suggest that scalp resurfacing by serial tissue expansion using a tissue expander can be used for extensive lesions.