• Title/Summary/Keyword: Tissue Phantom

Search Result 320, Processing Time 0.025 seconds

Skin Dose Distributions with Spoiler of 6MV x-ray for Head and Neck Tumor (두경부암 치료를 위한 6MV X-선 산란판의 제작과 산란분포 측정)

  • Lee, Ho-Soo;Lee, Jong-Keol;Lee, Byung-Jun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.176-184
    • /
    • 1995
  • It is very useful benefits to use the megavoltage photon beams in deep site tumor radiotherapy for skin sparing effects. But, In some cases of head and mock tumors, it is often necessary to use spoiler for rapid buildup on skin region. A spoiler with tissue equivalent material to be moved between the patients and the collimator can increase or control the skin dose and buildup region due to position and thickness of the spoiler was measured. Then, the effect of spoiler on skin dose and build up region in protruded tumor of head and neck was evaluated quantitatively. The measurements were abtained with PTW 2334 chamber (Markus type) on a polystylene phantom for 6MV x-ray from an accelerator.

  • PDF

Common-path Optical Interferometry for Stabilized Dynamic Contrast Imaging: A Feasibility Study

  • Seung-Jin, Lee;Young-Wan, Choi;Woo June, Choi
    • Current Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2023
  • The motion of organelles inside a cell is an important intrinsic indicator for assessing cell physiology and tissue viability. Dynamic contrast full-field optical coherence tomography (D-FFOCT) is a promising imaging technology that can visualize intracellular movements using the variance of temporal interference signals caused by biological motions. However, double-path interferometry in D-FFOCT can be highly vulnerable to surrounding noise, which may cause turbulence in the interference signals, contaminating the sample dynamics. Therefore, we propose a method for stabilized D-FFOCT imaging in noisy environments by using common-path interferometry in D-FFOCT. A comparative study shows that D-FFOCT with the proposed method achieves stable dynamic contrast imaging of a scattering phantom in motion that is over tenfold more noise-insensitive compared to the conventional one, and thus this imaging capability can provide cleaner motion contrast images. With the proposed approach, the intracellular dynamics of biological samples are imaged and monitored.

Absorbed and effective dose from periapical radiography by portable intraoral x-ray machine (이동형 구내 방사선촬영기로 촬영한 치근단 방사선사진의 흡수선량 및 유효선량 평가)

  • Cho, Jeong-Yeon;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.149-156
    • /
    • 2007
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for periapical radiography done by portable intraoral x-ray machines. Materials and Methods: 14 full mouth, upper posterior and lower posterior periapical radiographs were taken by wall-type 1 and portable type 3 intraoral x-ray machines. Thermoluminescent dosemeters were placed at 23 sites at the layers of the tissue-equivalent ART woman phantom for dosimetry. Average tissue absorbed dose and radiation weighted dose were calculated for each major anatomical site. Effective dose was calculated using 2005 ICRP tissue weighted factors. Results: On 14 full mouth periapical radiographs, the effective dose for wall-type x-ray machine was 30 Sv; for portable x-ray machines were 30 Sv, 22 Sv, 36 Sv. On upper posterior radiograph, the effective dose for wall-type x-ray machine was 4 Sv; for portable x-ray machines doses were 4 Sv, 3 Sv, 5 Sv. On lower posterior radiograph, the effective dose for wall type x-ray machine was 5 Sv; for portable x-ray machines doses were 4 Sv, 4 Sv, 5 Sv. Conclusion: Effective doses for periapical radiographs performed by portable intraoral x-ray machines were similar to doses for periapical radiographs taken by wall type intraoral x-ray machines.

  • PDF

Non-Invasive Blood Glucose Sensor By Sub-Microwave Oscillator (준 마이크로파 발진기를 이용한 비 침습 혈당 센서)

  • Yun, Gi-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.9
    • /
    • pp.9-16
    • /
    • 2017
  • In this paper, sub-microwave oscillator sensor is proposed to non-invasively monitor the glucose concentration level of the human biological tissue by oscillation frequency variation. Inductive slot in the ground plane of the microstrip line is combined with the biological tissue, to realize the resonator as a part of the oscillator sensor. The phantom box mimicking the human tissue is introduced for simulation of the resonator which resonance frequency correspondingly shifts up on three step glucose concentration levels(0, 400, 800 mg/dL). Oscillator sensor circuit is fabricated as a prototype. Pig tissues instead of human is used. Oscillation frequency shift of about 14 MHz per glucose level of 400 mg/dL has been successfully measured around 1,100 MHz. This proves that the proposed sensor is applicable to a blood glucose sensor.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

조영제 사용 전${\cdot}$후 불균질 조직 보정 알고리즘에 따른 선량변화에 대한 연구

  • Kim, Ju-Ho;Jo, Jeong-Hui;Lee, Seok;Jeon, Byeong-Cheol;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.38-46
    • /
    • 2001
  • Purpose : The aim of this study is to investigate the effect of tissue inhomogeneities when appling to contrast medium among Homogeneous, Batho and ETAR dose calculation method in RTP system. Method and Material : We made customized heterogeneous phantom it filled with water or contrast medium slab. Phantom scan data have taken PQ 5000 (CT scanner, Marconi, USA) and then dose was calculated in 3D RTP (AcQ-Plan, Marconi, USA) depends on dose calculation algorithm (Homogeneous, Batho, ETAR). The dose comparisons were described in terms of 2D isodose distribution, percent depth dose data, effective path length and monitor unit. Also dose distributions were calculated with homogeneous and inhomogeneous correction algorithm, Batho and ETAR, in each patients with different clinical sites. Results : Result indicated that Batho and ETAR method gave rise to percent depth dose deviation $1.5{\sim}2.7\%,\;2.3{\sim}3.5\%$ (6MV, field size $10{\times}10cm^2$) in each status with and without contrast medium. Also show that effective path lengths were more increase in contrast status (23.14 cm) than Non-contrast (22.07 cm) about $4.9\%$ or 10.7 mm (In case Hounsfield Unit 270) and these results were similary showned in each patient with different clinical site that was lung. prostate, liver and brain region. Concliusion : In conclusion we shown that the use of inhomogeneity correction algorithm for dose calculation in status of injected contrast medium can not represent exact dose at GTV region. These results mean that patients will be more irradiated photon beam during radiation therapy.

  • PDF

A absorbed and effective dose from the full-mouth periapical radiography using portable dental x-ray machine and panoramic radiography (ORIGINAL ARTICLE - 이동형 구내방사선촬영기로 촬영한 치근단 방사선촬영과 파노라마방사선촬영의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of the Korean dental association
    • /
    • v.50 no.7
    • /
    • pp.420-430
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for full-mouth periapical radiography using the portable dental x-ray machine and panoramic radiography Material and Method: Thermoluminescent chips were placed at 25sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable dental x-ray machine and panoramic unit. During full-mouth periapical radiography the exposure setting was 60 kVp, 2 mA and 0.15 ~ 0.25 seconds, while during panoramic radiography the selected exposure setting was 72 kVp, 8 mA and 18 seconds. Absorbed dose measurements were obtained and equivalent doses to individual organs were summed using ICRP 103 to calculate of effective dose. Result: In the full-mouth periapical radiography, the highest absorbed dose was recorded at the mandible body follow with submandibular glands and cheek. Using panoramic unit, the highest absorbed dose was parotid glands and the following was back of neck and submandibular glands. The effective dose in full-mouth periapical radiography using portable dental x-ray machine was 46 ${\mu}Sv$. In panoramic radiography, the effective dose was 38 ${\mu}pSv$. Conclusion: It was recommended to panoramic radiography for general check in the head and neck area because that the effect dose in the panoramic radiography was lower than the dose in the full-mouth periapical radiography using portable dental x-ray machine.

Fast Acoustic Radiation Force Impulse Imaging Using Non-focused Transmission in Medical Ultrasound Imaging (초음파 의료 영상에서 비집속 송신을 이용한 고속 음향 복사력 임펄스 영상법)

  • Choi, Seung-Min;Park, Jeong-Man;Kwon, Sung-Jae;Jeong, Mok-Kun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.151-160
    • /
    • 2012
  • In medical ultrasound imaging, elasticity imaging helps to diagnose tumors such as cancer. This paper is concerned with the application of acoustic radiation force to soft tissue of interest to implement elasticity imaging. In order to reduce the data acquisition time, instead of relying on transmit focusing, a plane wave of burst type is transmitted to apply the acoustic radiation force simultaneously to an entire imaging region to be observed. A homogeneous phantom experiment confirms that increasing the transmit excitation duration instead of employing transmit focusing generates a high enough acoustic radiation force to obtain elasticity images. It is found, however, that a different displacement versus time characteristic is observed unlike the case of using a conventional focused acoustic radiation force. Experimental results obtained through the use of an ultrasound phantom and a bovine liver show that lesions can be correctly differentiated.

A New Method for Measuring the Dose Distribution of the Radiotherapy Domain using the IP

  • Homma, Mitsuhiko;Tabushi, Katsuyoshi;Obata, Yasunori;Tamiya, Tadashi;Koyama, Shuji;Kurooka, Masahiko;Shimomura, Kouhei;Ishigaki, Takeo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.237-240
    • /
    • 2002
  • Knowing the dose distribution in a tissue is as important as being able to measure exposure or absorbed dose in radiotherapy. Since the Dry Imager spread, the wet type automatic processor is no longer used. Furthermore, the waste fluid after film development process brings about a serious problem for prevention of pollution. Therefore, we have developed a measurement method for the dose distribution (CR dosimetry) in the phantom based on the imaging plate (IP) of the computed radiography (CR). The IP was applied for the dose measurement as a dosimeter instead of the film used for film dosimetry. The data from the irradiated IP were processed by a personal computer with 10 bits and were depicted as absorbed dose distributions in the phantom. The image of the dose distribution was obtained from the CR system using the DICOM form. The CR dosimetry is an application of CR system currently employed in medical examinations to dosimetry in radiotherapy. A dose distribution can be easily shown by the Dose Distribution Depiction System we developed this time. Moreover, the measurement method is simpler and a result is obtained more quickly compared with film dosimetry.

  • PDF