• 제목/요약/키워드: Tissue Heterogeneity Correction

검색결과 8건 처리시간 0.027초

자궁경부암 근접치료 시 선량 검증 프로그램을 통한 임상적 위험성 평가 (Clinical Risk Evaluation Using Dose Verification Program of Brachytherapy for Cervical Cancer)

  • 강동진;신영주;강진규;정재용;이우진;백태성;이보람
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권6호
    • /
    • pp.553-560
    • /
    • 2022
  • The purpose of this study is to evaluate the clinical risk according to the applicator heterogeneity, mislocation, and tissue heterogeneity correction through a dose verification program during brachytherapy of cervical cancer. We performed image processing with MATLAB on images acquired with CT simulator. The source was modeled and stochiometric calibration and Monte-Carlo algorithm were applied based on dwell time and location to calculate the dose, and the secondary cancer risk was evaluated in the dose verification program. The result calculated by correcting for applicator and tissue heterogeneity showed a maximum dose of about 25% higher. In the bladder, the difference in excess absolute risk according to the heterogeneity correction was not significant. In the rectum, the difference in excess absolute risk was lower than that calculated by correcting applicator and tissue heterogeneity compared to the water-based calculation. In the femur, the water-based calculation result was the lowest, and the result calculated by correcting the applicator and tissue heterogeneity was 10% higher. A maximum of 14% dose difference occurred when the applicator mislocation was 20 mm in the Z-axis. In a future study, it is expected that a system that can independently verify the treatment plan can be developed by automating the interface between the treatment planning system and the dose verification program.

컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험 (Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments)

  • 최태진;김진희;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제17권2호
    • /
    • pp.105-113
    • /
    • 2006
  • 본 연구는 전산치료선량계획장치에서 중첩(Superposition)법을 사용해 비균질성 조직층을 통한 교정선량을 확인하기 위해 수행되었다. 조직등가물질로는 폐조직으로 콜크($\rho=0.2\;g/cc$)를, 근조직에는 n-Glucose, 골조직에는 $K2HPO4$를 사용한 시료의 전자밀도를 구하였으며, CT영상은 110 KVp와 130 KVp X선을 주사해서 얻고 CT번호(H)와 전자밀도의 함수관계를 조사하였다. 물에 대한 전자밀도비는 컴퓨터선량계획에 중요한 변수이므로 CT번호에 대응된 전자밀도비를 입력하고, 선량확인을 위해 펜텀 구성은 폴리스탈린 고체 펜텀 사이에 5.0 cm 층의 시료를 삽입하고 깊이 12.0 cm와 20.0 cm의 조직 선량을 구하여 실측과 비교하였다. 실험결과 CT번호-전자밀도비는 광전효과 현상에 영향을 크게 받게 되어 원자번호가 높은 재질에서 비선형적으로 나타났으며, 130 KVp에서 근조직에는 0.001026H+1.00을, 골조직에는 0.000304H+1.07을 얻었다. 균질 근조직에서 컴퓨터선량과 실측선량을 비교한 결과 중첩법과 FFT 콘볼루션(convolution) 법에서 6, 15 MV X선 모두 1.0% 오차 범위내에 있었으며, 폐조직층 통과한 경우 중첩법은 6 MV X선에서 평균 -1.2%, 골조직에는 평균 -2.9%를 보였고, 15 MV X선에서 2.7%와 2.2%를 얻었으며, FFT콘볼루션법은 6 MV X선에서 폐조직 2.8%, 골조직 -5.0%를 보였고, 15MV X선에서는 각각 6.0%, 0.2%를 보여 중첩법에 의한 치료계획선량이 신뢰성이 있음을 확인하였다. 본 실험을 통해 저자들은 각 임상기관에서 사용하고 있는 CT는 일정하지 않고 교정이 필요한 장비이므로, 발전된 치료계획시스템에 적용하고 있는 CT번호-전자밀도비에 대한 정기적인 확인이 필요하며, FFT 콘볼루션법에 비해 빔의 확산방향에 일치된 커널빔을 사용한 중첩법에서 오차가 적음을 확인하였다.

  • PDF

전립선암의 세기조절 방사선 치료시 밀도보정의 효과 (The Impact of Tissue Inhomogeneity Corrections in the Treatment of Prostate Cancer with Intensity-Modulated Radiation Therapy)

  • 한영이;박원;허승재
    • 한국의학물리학회지:의학물리
    • /
    • 제15권3호
    • /
    • pp.149-155
    • /
    • 2004
  • 목적: 전립선암의 세기조절 방사선 치료 시, 조직의 밀도보정 여부가 선량분포에 끼치는 영향을 연구한다. 재료 및 방법: 5명의 전립선 암 환자에 대하여 6 MV와 10 MV의 광자선에 대하여 각각 치료계획을 수립하였다. 각각 의 계획에서 7개의 조사선이 설정되었고, 선량계산 시에는 체조직의 밀도의 불균일성을 무시하였다. 선량 처방점인 회전중심점에서의 흡수선량과 계획표적용적(PTV)의 최대선량, 최소선량, 평균선량과 처방점선량의 95% 이상의 받는 부피(V>$_{p95%}$) 등을 측정하였다. 직장과 방광 내에서의 최대선량, 최소선량, 최방선량의 50%, 75%, 90% 이상을 받는 부피를 측정하였다. 동일한 조건에서 조직의 밀도 불균일성을 포함하여 선량분포를 재계산하고, 측정한 모든 물리량을 재 측정하였다. 결과: 밀도보정을 함으로써, 처방점에서의 흡수 선량은 6 MV에서 평균 4.9% 10 MV에서는 평균 4% 감소하였다. V>$_{p95%}$는 6 MV와 10 MV에서 각각 0.8%와 0.9% 감소하였다. PTV의 평균 흡수 선량은 6 MV와 10 MV에서 각각 4.2% 와 3.4% 감소하였다. 직장과 방광에서의 흡수선량은 약 l~2%의 차이를 보였다 결론: 전립선암의 세기변조 방사선치료시에 밀도보정을 무시하는 것은 표적에는 고려할 만한 선량의 차이를 유발하며, 주위의 위험장기에 미치는 영향은 미미하다.

  • PDF

Treatment outcome and long-term stability of orthognathic surgery for facial asymmetry: A systematic review and meta-analysis

  • Yoon-Ji Kim;Moon-Young Kim;Nayansi Jha;Min-Ho Jung;Yong-Dae Kwon;Ho Gyun Shin;Min Jung Ko;Sang Ho Jun
    • 대한치과교정학회지
    • /
    • 제54권2호
    • /
    • pp.89-107
    • /
    • 2024
  • Objective: This systematic review aimed to provide a comparative analysis of the treatment outcomes, including hard and soft tissues, postoperative stability, temporomandibular disorders (TMD), and quality of life (QoL), in patients with facial asymmetry who underwent orthognathic surgery. Methods: The primary objective was to address the question, "How do different factors related to surgery affect the outcomes and stability of orthognathic surgery in the correction of facial asymmetry?" A meta-analysis was conducted on the outcome parameters, such as skeletal, dental, and soft tissue symmetry, TMD, QoL, and relapse, using the Hartung-Knapp-Sidik-Jonkman method for random-effects models. Subgroup analyses were conducted considering surgery-related factors such as surgical techniques (one-jaw vs. two-jaw), use of the surgery-first approach, utilization of computer simulation, and analytical methods employed to evaluate asymmetry (2D vs. 3D). Results: Forty-nine articles met the inclusion criteria. The metaanalysis demonstrated a significant improvement in the symmetry of hard and soft tissues. The subgroup analysis indicated that the treatment outcomes showed significant improvement, regardless of the factors related to surgery. Changes in TMD signs and symptoms varied according to the surgical technique used. Quality of life improved in the facial, oral, and social domains. Skeletal relapse was observed during the follow-up. Conclusions: Our findings support the positive outcomes of orthognathic surgery in the treatment of facial asymmetry in terms of skeletal and soft tissue improvements, stability, relief of TMD symptoms, and enhancement of QoL. However, most of the included studies showed a low certainty of evidence and high heterogeneity.

Treatment efficacy of gingival recession defects associated with non-carious cervical lesions: a systematic review

  • Oliveira, Livia Maria Lopes de;Souza, Camila Agra;Cunha, Sinara;Siqueira, Rafael;Vajgel, Bruna de Carvalho Farias;Cimoes, Renata
    • Journal of Periodontal and Implant Science
    • /
    • 제52권2호
    • /
    • pp.91-115
    • /
    • 2022
  • Purpose: This systematic review aimed to compare the efficacy, defined in terms of the mean percentage of root coverage (mRC), of surgical treatment approaches combined with adhesive restorations of non-carious cervical lesions (NCCLs) to that of root coverage alone in patients with a single gingival recession (GR) and NCCL. Methods: A literature search was conducted to identify longitudinal studies reporting the mRC following treatment for the correction of GR defects associated with NCCLs using a combination of surgical and restorative techniques in systemically and periodontally healthy patients. Results: The search resulted in the retrieval of 12,409 records. Seven publications met the inclusion criteria for the qualitative synthesis of data. The mRCs ranged from 69% to 97%. In the medium term, the gingival margin position was more stable when a connective tissue graft (CTG) was used, independently of whether restoration of teeth with NCCLs was performed. Conclusions: The strength of the evidence was limited by methodological heterogeneity in terms of study design as well as the unit and period of analysis, which precluded a metaanalysis. Although no definitive conclusion could be drawn due to the lack of sufficient evidence to estimate the effectiveness of the interventions, CTG-based procedures contributed to gingival margin stability regardless of the performance of restoration to treat NCCLs.

감마 나이프 방사선 수술시 필름 선량 측정에 의한 조직 불균일성에 대한 연구 (Evaluation of Tissue Inhomogeneity for Gamma-knife Radiosurgery Using Film Dosimetry)

  • 조흥래;손승창;서현숙
    • Radiation Oncology Journal
    • /
    • 제16권3호
    • /
    • pp.325-335
    • /
    • 1998
  • 목적 : 감마 나이프에 사용되고 있는 코발트-60의 골에 의한 흡수 선량 감소는 -3.5$\%$이다. 그러나 모든 방사선 수술 치료 계획 시스템은 치료 부위를 단위밀도 (unit density)로 가정하여 계산을 시행하므로 조직 불균일성에 대한 고려를 하지않고 있다. 중두개와 (mid cranial fossa) 부위는 여러 두께의 골로 구성되어 있기 때문에 감마 나이프를 이용한 방사선 조사시 중두개와에 위치한 병변인 뇌하수체 종양 지점이나 청신경 초종 지점의 치료시 흡수되는 방사선량은 방사선 수술 계획 시스템에 의하여 계산한 값과 차이가 날 가능성이 있다. 이 연구는 이러한 중두개와에 위치한 병변의 치료시 골에 의한 흡수 선량의 감소에 대한 검증을 위하여 시행하였다. 대상 및 방법 : Alderson Rando phantom (이하 인체 모형 판톰-human phantom-이라 명명)의 두개골 부위에 4개의 핀에 의해 Leksell stereotactoc frame을 고정시키고 뇌단층 촬영을 시행하였다. 뇌 단층 촬영 상에 뇌하수체 종양과 청신경 초종(acoustic neurimona)에 해당되는 각각의 지점을 정한 후 먼저 뇌하수체 지점에 인체 모형 판톰의 모양에 맞게 자른 코닥 X-omat V 필름을 사이에 넣고 인체 모형 판톰을 잘 고정한 후에 14 mm 조준기 (collimator)를 부착하여 방사선을 조사하였다. 한 지점당 3회 반복 시행하였다. 18 mm 조준기를 이용하여 동일한 방법으로 3회 반복 시행하였다. 두 번째 지점인 청신경 초종 지점에 필름을 넣은 뒤 첫 번째와 동일한 방법으로 14 mm 조준기와 18 mm 조준기를 사용하여 각각 3회 반복 시행하였다. 동일한 실험 조건으로 균일한 밀도로 이루어진 16 cm 지름의 구형 폴리스티렌 판톰 내에 폴리스티렌 카세트에 맞는 필름을 삽입하여 14 mm, 18 mm 조준기 각각에 대하여 방사선 조사를 시행하였으며 이 과정을 3회 반복 시행하였다. 이후 필름들을 현상하여 VXR-12 필름 광학 측정기를 이용하여 등선량 곡선을 얻는다. 여기서 얻어진 등선량 곡선 (isodose curve)을 기초로 하여 off axis ratio 곡선을 얻었다. 결과 : 중두개와에 위치한 병소에 대하여 감마 나이프를 이용한 방사선 조사를 시행할 때 골에 의한 흡수 선량 감소는 뇌하수체 종양 지점이 청신경 초종 지점보다 많이 나타났으며 (0.2-3.0 mm vs. 0.1-1.3 mm) 조준기 크기에 따라 14 mm 조준기일 경우가 18 mm 조준기보다 더 많은 흡수 선량 감소 (0.4-3.0 mm vs. 0.2-2.2 mm)를 보였다. 결론 : 흡수 전량 감소가 실제 임상에서 치료 계획을 세우는데 있어서는 큰 영향을 미치지 않는 범위 내 (1 mm)에서 일어남으로 골에 의한 흡수 선량 감소를 고려하여 치료계획을 조정해야 할 필요는 없을 것으로 생각된다.

  • PDF

전립선암의 세기조절 방사선치료 시 불균질부에 의한 선량변화에 관한 고찰 (The Investigation Regarding the Dose Change due to the Heterogeneity of Prostate Cancer Treatment with IMRT)

  • 윤일규;박장필;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제19권2호
    • /
    • pp.107-112
    • /
    • 2007
  • 목 적: 본원에서 시행하고 있는 전립선암의 세기조절 방사선치료시 직장 내에 존재하는 불균질부에 의한 선량변화를 전산화 치료계획 선량과 자체 제작한 전립선암 환자형 골반 팬톰을 이용하여 측정한 선량을 비교하고자 한다. 대상 및 방법: 전립선암 환자형 골반 팬톰(타원형의 물 팬톰: $30\times20\times20cm^3$, 방광, 직장, 정낭을 묘사하는 팬톰)을 제작하였으며, 전산화단층촬영으로 3차원 영상을 획득하였다. 전산화치료계획장치(ECLIPSE, Varian, USA), 6 MV X선(Clinac 6EX, Varian, USA)을 이용하여 세기조절 방사선치료계획을 수립한 후, 전립선암 환자형 골반 팬톰을 이용하여 직장벽, 방광벽, 정낭 부위에 TLD를 삽입하고, 전산화치료계획 선량과 비교하였다. 결 과: 전산화치료계획에 의한 선량은 직장벽 100%, 방광벽 52%, 우측 정낭 86%, 좌측 정낭 87%, 표면 18%였으나, TLD로 측정 한 선량은 직장벽 89%, 방광벽 54%, 우측 정낭 85%, 좌측 정낭 84%, 표면 17%로 측정되었다. 직장벽은 11%, 방광벽은 2%, 우측 정낭은 1%, 좌측 정낭 3%, 표면 1%의 선량차이를 확인하였다. 결 론: 본원에서 개발한 전립선암 환자형 골반 팬톰으로 전산화치료계획에서 구현하는 불균질부 선량계산의 오차를 확인할 수 있었으며, 다양한 선량 측정 장치(TLD, film)를 이용하여 쉽고 간편하게 선량 검증을 할 수 있을 것으로 사료된다.

  • PDF