• 제목/요약/키워드: Tip-speed ratio

검색결과 152건 처리시간 0.022초

Nonlinear response of the pile group foundation for lateral loads using pushover analysis

  • Zhang, Yongliang;Chen, Xingchong;Zhang, Xiyin;Ding, Mingbo;Wang, Yi;Liu, Zhengnan
    • Earthquakes and Structures
    • /
    • 제19권4호
    • /
    • pp.273-286
    • /
    • 2020
  • The pile group foundation is widely used for gravity pier of high-speed railway bridges in China. If a moderate or strong earthquake occurs, the pile-surrounding soil will exhibit obvious nonlinearity and significant pile group effect. In this study, an improved pushover analysis model for the pile group foundation with consideration of pile group effect is presented and validated by the quasi-static test. The improved model uses simplified springs to simulate the soil lateral resistance, side friction and tip resistance. PM (axial load-bending moment) plastic hinge model is introduced to simulate the impact of the axial force changing of pile group on their elastic-plastic characteristics. The pile group effect is considered in stress-stain relations of the lateral soil resistance with a reduction factor. The influence factors on nonlinear characteristics and plastic hinge distribution of the pile group foundation are discussed, including the pier height, longitudinal reinforcement ratio and stirrup ratio of the pile, and soil mechanical parameters. Furthermore, the displacement ductility factor, resistance increase factor and yielding stiffness ratio are provided to evaluate the seismic performance of soil-pile system. A case study for the pile group foundation of a railway simply supported beam bridge with a 32 m-span is conducted by numerical analysis. It is shown that the ultimate lateral force of pile group is not determined by the yielding force of the single one in these piles. Therefore, the pile group effect is essential for the seismic performance evaluation of the railway bridge with pile group foundation.

솔리디티에 따른 H-로터의 공기역학적 특성 및 성능해석 (Numerical Analysis of Aerodynamic Characteristics and Performance Analysis on H-rotor with Various Solidities)

  • 주성준;이주희
    • 한국유체기계학회 논문집
    • /
    • 제19권6호
    • /
    • pp.5-13
    • /
    • 2016
  • Three-dimensional unsteady numerical analysis has been performed to observe aerodynamic characteristics of a H-rotor. Generally, the structure of the H-rotor is simple but the aerodynamic characteristics are exceptionably complicated since the angle of attacks and incident velocities to a blade are considerably varied according to the azimuth angles and solidities. The blade in the upwind revolution between 0 to 180 degree obtains aerodynamic energy from the free stream but the blade in the downwind revolution between 180 to 360 degree does not. When the rotating speed increases, the blade in the downwind revolution accelerates the air around the blade like a fan and it consumes the energy and shows negative torque in the area. On the other hand, the direction of the free stream is bent because of the interaction between blade the free stream. Therefore, the operation point (highest power coefficient) appears at a lower tip-speed-ratio what it is expected.

PHILS 기반 2 MW급 조류발전시스템 특성 분석 (PHLIS-Based Characteristics Analysis of a 2 MW Class Tidal Current Power Generation System)

  • 고병수;성해진;박민원;유인근
    • 한국정밀공학회지
    • /
    • 제31권8호
    • /
    • pp.665-670
    • /
    • 2014
  • In this paper, characteristics of a tidal current power generation system are analysis using power hardware-in-the-loop simulation (PHILS). A 10 kW motor generator set is connected to the real grid through a fabricated 10 kW back to back converter. A power control scheme is applied to the back to back converter. A 2 MW class tidal current turbine is modeled in real time digital simulator (RTDS). Generating voltage and current from the 10 kW PMSG is applied to a 2 MW class tidal current turbine in the RTDS using PHILS. The PHILS results depict the rotation speed, power coefficient, pitch angle, tip-speed ratio, and output power of tidal current turbine. The PHILS results in this paper can contribute to the increasing reliability and stability of the tidal current turbines connected to the grid using PHILS.

진도 울돌목 조류발전 시스템 실증 평가 (Empirical Evaluation of Tidal Current Generation System at Ul-Dol-Mok in Jin-do)

  • 문석환;박병건;김지원
    • 한국정밀공학회지
    • /
    • 제33권2호
    • /
    • pp.157-163
    • /
    • 2016
  • The empirical evaluation of grid-connected tidal current generation system is presented in this paper. The Ul-dol-mok in Jin-do has been estimated to have tidal power of 1GW. In order to experiment, HAT (Horizontal Axis Turbine) 3-blade and 20kW grid-connected tidal current generation system was established at Ul-dol-mok in Jin-do. To generate power of generator, the speed reference of the PMSG is generated from the Cp curve and TSR (Tip Speed Ratio) of the designed turbine. The control of the converter connected to the grid is controlled to regulate unity power factor. The result showed that the turbine efficiency and system efficiency is 37 % and 31 %. This was achieved that target rate is 30 %, 20 %, respectively.

500kW급 풍력터빈의 성능평가에 관한 수치해석적 연구 (Estimate of the power characteristics of the 500kw wind turbine based on 3D numerical solutions)

  • 김범석;이진석;김정환;이도형;이영호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 춘계 학술대회논문집
    • /
    • pp.140-145
    • /
    • 2002
  • The purpose of this 3-D numerical simulation is to calculate and examine a 500 kW Horizontal Axis Wind Turbine (HAWT) power performance and compare to calculation data(BEM method) from Delft University. The experimental approach, which has been the main method of investigation, appears to be reaching its limits, the cost increasing relate with the size of wind turbines. Hence, the use of Computational Fluid Dynamics (CFD) techniques and Navier-Stokes Solvers are considered a very serious contender. We has used the CFD software package CFX-TASC flow as a modeling tool to predict the power performance of a wind turbine on the basis of its geometry and operating data. The wind turbine with 40m diameters rotor, it was scaled to compare with the calculation data from delft university. The HAWT, which has eight-rpm variations are investigated respectively. The pitch angle is $+0.5^{\circ}$ and wind speed is fixed at 5m/s. The tip speed ratio (TSR) of the HAWT ranging from 2.89 to 9.63.

  • PDF

수직축 풍차의 자기동 성능 개선 (Improving the Self-starting Performance of a VAWT)

  • 정선환;최성대;손재율;맥이사 알렉산더;김신호;최명수
    • 한국기계가공학회지
    • /
    • 제5권4호
    • /
    • pp.13-20
    • /
    • 2006
  • The inherent problem of a Darrieus wind turbine is its inability to self-start. Usually, a motor is used to provide angular acceleration until lift forces are produced in the airfoil blades or up until the turbine can already sustain its speed on its own. This paper describes a method of improving the self-starting of an H-type Darrieus vertical axis wind turbine (VAWT) by incorporating a helical Savonius turbine thus utilizing a drag-lift combination. The effect of each turbine in the combination relative to each other is investigated by testing a prototype windmill consisting of three NACA 0015 airfoil blades combined with a Savonius rotor with a helix angle of 180 degrees and whose swept area equals 30% of the entire turbine.

  • PDF

P&O알고리즘을 이용한 조류발전 시스템의 최대출력 제어 (Maximum Power Control of Tidal Current Generation System using P&O Algorithm)

  • 문석환;김지원;박병건;김장목
    • 전력전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.199-206
    • /
    • 2017
  • Maximum Power Point Tracking (MPPT) control needs to generate the maximum power of a tidal current turbine. A tidal current speed sensor is required to achieve effective generated power in a tidal current generation system. The most common methods used to achieve such power is the tip speed ratio of turbine and tidal current information. However, these methods have disadvantages, such as expensive installation of the tidal current sensor, parameter errors in turbine design, and different information according to the installed position of the tidal current sensor. This paper proposes a maximum power control scheme using perturb-and-observe (P&O) for tidal current generation system. The proposed P&O MPPT scheme can achieve the maximum power without tidal current sensors and turbine design parameters. The reliability and suitability of the proposed control scheme are proven through simulation and experiment results at the tidal current generation laboratory.

Performance Research of Counter-rotating Tidal Stream Power Unit

  • Wei, Xuesong;Huang, Bin;Liu, Pin;Kanemoto, Toshiaki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권2호
    • /
    • pp.129-136
    • /
    • 2016
  • An experimental investigation was carried out to improve the performance of a counter-rotating type horizontal-axis tidal stream power unit. Front and rear blades were designed separately based on modified blade element momentum (BEM) theory, and their performances at different conditions of blade tip speed ratio were measured in a wind tunnel. Three different groups of blades were designed successively, and the results showed that Group3 possessed the highest power coefficient of 0.44 and was the most satisfactory model. This experiment shows that properly increasing diameter and reducing chord length will benefit the performance of the blade.

고받음각 오자이브의 비대칭 와류에 작용하는 구동기 효과 분석 (Effect of the Flow Actuator on the Asymmetric Vortex at High Angle of Attack)

  • 이은석;이진익;이광섭
    • 한국군사과학기술학회지
    • /
    • 제16권5호
    • /
    • pp.607-612
    • /
    • 2013
  • The effect of the flow actuator on the asymmetric vortex structure around the ogive-cylinder body with fineness ratio of 4 flying at the speed of Mach 0.1 at angle of attack of 50 degree is studied. The ogive-cylinder model is developed with the actuator placed near the nose tip and numerically simulated using the in-house CFD code named KFLOW. The numerical simulation employs two different actuator modeling: one is the boundary condition given by blowing normal to the surface and another shearing on the surface. The numerical simulation reveals that response of the vortex structure to the actuation is dependent on the type of modeling as well as the strength and direction of the actuation.

프로판 예혼합화염의 소음발생 매커니즘에 관한 실험적 연구 (An Experimental Study on the Noise Generation Mechanisms of Propane Premixed Flames)

  • 이원남;박동수
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.27-33
    • /
    • 2004
  • The Noise generation mechanisms of propane laminar premixed flames on a slot burner have been studied experimentally. The sound levels and frequencies were measured for various mixture flow rates (velocities) and equivalence ratios. The primary frequency of self-induced noise increases with the mean velocity of mixture as $f{\;}{\propto}{\;}U_f^{1.144}$ and the measured noise level increases with the mixture flow rate and equivalence ratio as $p{\;}{\propto}{\;}U_f^{1.7}$$F^{8.2}$. The nature of flame oscillation and the noise generation mechanisms are also investigated using a high speed CCD camera and a DSRL camera. The repetition of sudden extinction at the tip of flame is evident and the repetition rates are identical to the primary frequencies obtained from the FFT analysis of sound pressure signals. CH chemiluminescence intensities of the oscillating flames were also measured by PMT with a 431 nm(10 FWHM) band pass filter and compared to the pressure signals.

  • PDF