• Title/Summary/Keyword: Tip size

Search Result 613, Processing Time 0.024 seconds

Numerical Simulations of Crack Initiation and Propagation Using Cohesive Zone Elements (응집영역요소를 이용한 균열진전 모사)

  • Ha, Sang-Yul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.6
    • /
    • pp.519-525
    • /
    • 2009
  • In this study a cohesive zone model was used to simulate the delamination phenomena which occurs by a successive crack initiation and propagation in composite laminates. The cohesive zone model was incorporated to the classical finite element method via cohesive element formulation and then implemented into the user-subroutine UEL of a commercial finite element program Abaqus. To validate the formulation and implementation of the cohesive element the finite element results were compared with the experimental data of double cantilever beam and end notched flexure tests. The numerical results well agree with the experimental load-displacement curves. Also the effect of the elastic stiffness and the size of the cohesive element on the global load-displacement curves were studied numerically. To minimize the mesh-dependency of the crack propagation path and eliminate the zig-zag patterns in the load-displacement curve, cohesive elements should be refined at the crack-tip.

Effect of Water Content on the Morphology of ZnO Powders Synthesized in Binary Solvent Mixtures by Glycol Process

  • Phimmavong, Kongsy;Song, Jeong-Hwan;Cho, Seung-Beom;Lim, Dae-Young
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.3
    • /
    • pp.211-216
    • /
    • 2017
  • ZnO nanopowder was synthesized using a relatively facile and convenient glycol process. ZnO nanopowder was successfully synthesized at temperatures as low as $125^{\circ}C$ using zinc acetate as the Zn source and 1,4-butanediol as the solvent. Then, the effects of water content on the growth process and morphological evolution of ZnO powders were investigated using 1,4-butanediol and water as binary solvent mixtures. Using pure 1,4-butanediol at a temperature above $125^{\circ}C$, the prepared hexagonal ZnO nanopowder exhibited a quasi-spherical shape with average crystalline size of approximately 30 - 50 nm. It is also demonstrated that the morphology of ZnO powders can be controlled by the addition of various water content in 1,4-butanediol. With increasing water content, the morphologies of the ZnO powders changed sequentially from quasi-spherical to hexagonal plate and pyramid, and finally to hexagonal prismatic with a pyramidal tip. A sharp peak centered at 384 nm in the UV region and a weak broad peak in the visible region between 450 and 700 nm were shown in the room temperature PL spectra of the ZnO synthesized using the glycol process, regardless of the addition of water, suggesting that ZnO nanopowders with the best crystallinity were obtained under these conditions.

Mechanical Design and Development of a Digital Tongue Imaging System Equipped with LEDs (LED 광원을 이용한 디지털 혀 영상 촬영장치의 기구설계와 개발)

  • Nam, Dong-Hyun;Kim, Ji-Hye;Lee, Sang-Suk
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.3
    • /
    • pp.41-48
    • /
    • 2012
  • Objectives: The aims of this study are to design a optimized mechanical structure of digital tongue imaging system (DTIS) equipped with LEDs in aspects of object distance and camera angle of coverage. Methods and Results: We tried to find optimized object distance while recording a rectangular object of common tongue size. In case object distance is 22 cm or less, edge of the rectangle was not taken beyond the shooting range. In contrast, if object distance is 40 cm or more, the rectangle image was too small. Therefore when considering the variation of subjects, we selected distance of 35-40 cm as appropriate object distance for the DTIS. We also tried to find optimized angle between camera view axis and horizontal line. We photographed from the side of the face of 7 adults with exposed tongue. We drew an exposed tongue lines to connect the tongue tip points and the tongue root points by using the photos acquired from the side faces. And then we calculated the tongue exposure angles between the vertical line and the exposed tongue lines. Mean tongue exposure angle was $28.3^{\circ}$ when tongue was lightly exposed and $13.3^{\circ}$ when maximally. So we determined $73^{\circ}$ as appropriate slope angle of part in contact with face of the DTIS and by considering that the standard variation was great, we designed control gears to adjust the slope of the camera view axis and to regulate the object distance. Conclusions: We designed a optimized mechanical structure in object distance and slope angle of part in contact with face of the DTIS.

Effect of bST Co-Treatment with FSH on Transvaginal Ultrasound-Guided Oocyte Retrieval(TVR) in Calves (송아지 난소에서 초음파 유도에 의한 한우의 미성숙난자 채취시에 bST-FSH 처리효과에 관한 연구)

  • 이병천;이강남;김남렬;황우석
    • Journal of Embryo Transfer
    • /
    • v.11 no.2
    • /
    • pp.103-109
    • /
    • 1996
  • The aim of this study was to evaluate the effect of recombinant bovine somatotropin (bST; Boostin-S, LG Chem) treatment with FSH (Super OV) or PMSG on superovulatory response for transvaginal ultrasound-guided oocyte retrieval (TVR) in calves. Eight Korean Native Cattle(KNC) heifer calves; 150 to 240 days old; were randomly assigned to four treatment groups: 1) FSH(75 mg); 2) FSH (75 mg) + bST(500mg) 3) PMSG(1;000 IU); 4) PMSG(1, 000 IU) + bST(500 mg). Experimental calves in group 1 (n=2) and 2(n=2) were weekly superovulated for 4 consecutive weeks with daily injection of FSH for 3days and the next day subjected to TVR session. Animals in group 3 (n=2) and 4(n=2) were weekly stimulated for 4 consecutive weeks with a single dose of 1, 000 IU PMSG. TVR was performed on 72 hours after PMSG injection. Calves in group 2 and 4 was received injection of 500 mg of bST every 10 days. At each TVR session, follicle number and size were recorded; the oocytes collected and graded according to cumulus and cytoplasm investment. Collected oocyte were determined viable oocyte according to morphological quality with granulation of oocyte and number and status of cumlulus cells. IVM and IVF were performed and assessed cleavage rate on day 3 after fertilization. A Sonovet 600(Medison, Co., Ltd) realtime ultrasound scanner with a 6.5 MHz convex transducer, fixed at the tip of 500 mm estended handle equipped with a needle guide was used in collecting oocyte. Differences between groups were analysed by chi-square test. The population of large follicle ($\geq$5 nun) and aspiration rate were not significant different among the 4 groups. But, the number of small follicles (<5 mm) and aspirated oocyte in the KNC calves treated with bST were 1.3~1.6 times higher than in KNC calves treat with FSH or PMSG alone. In conclusion, the administration of bST with FSH or PMSG at superovulation for TVR in calves was increase the nurnber of small follicle which was influenced the number of aspiratable follicle.

  • PDF

Effect of Acupuncture at the LU5(Reinforcement), LU10(Reduction) on the Pulsation Scale of Chon, Gwan and Chuk region using High Resolution Infrared Camera (척택.어제 침자가 고해상도 적외선 카메라로 관찰한 촌구맥 부위의 온도 Pulsation 변화에 미치는 영향 연구)

  • Na, Chang-Su;Jeon, Hyo-Sang;Kim, Jee-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.127-133
    • /
    • 2011
  • Arteria radialis is a branch of the brachial artery extending down the forearm around the wrist where it closes to skin surface. In the oriental medicine, the skin above arteria radialis has an important role because oriental medicine practitioners put their finger tips on the area, and diagnose patient's health conditions by feeling the pulsation of the arterial contraction. The finger tip diagnostic method relies on subjective decision of the practitioner; and there is a need to develop an objective diagnostic modality. The pulsation of the arterial contraction appears not only a movement on the site but also as temperature fluctuation due to pulsatile feeding of warmer blood. The goal of this study is to demonstrate a feasibility of using an infrared camera quantitatively to detect the temperature fluctuation on the skin. Clinical important three different areas, called chon, gwan, chuk, near a wrist where the arteria radialis reaches close to skin surface are marked with small pieces of surgical tape. A high-speed and high-resolution infrared camera with a 3 cm of field of view measures these areas for 10 second at 200 frames per second with a 320*240 pixel size. The pulsatile temperature fluctuation is calculated after passing a band pass filter to remove any stationary temperature over 10 second. The temperature fluctuation of a healthy male volunteer is measured at a room temperature as a control, and is compared with another measurement performed after 20 minutes staying in a room at a 40 degree Celsius. This comparison is repeated for three times, and indicates that the fluctuation increases after staying 20 minutes in the warm room. This increase becomes smaller when the person stays in the warm room with an acupuncture treatment that decreases body temperature. So that an objective diagnostics on the site may become feasible.

Micro/Nano Adhesion and Friction Properties of SAMs with Different Head and Functional Group according to the Coating Methods (코팅 방법에 따른 이종 SAMs의 관능기별 마이크로/나노 응착 및 마찰 특성)

  • Yoon Eui-Sung;Oh Hyun-Jin;Han Hung-Gu;Kong Hosung
    • Tribology and Lubricants
    • /
    • v.21 no.3
    • /
    • pp.107-113
    • /
    • 2005
  • Micro/nano adhesion and friction properties of self-assembled monolayers (SAMs) with different head- and end-group were experimentally studied according to the coating methods. Various kinds of SAM having different spacer chains (C10 and C18), head-group and end-group were deposited onto Si-wafer by dipping and chemical vapour deposition (CVD) methods under atmospheric pressure, where the deposited SAM resulted in the hydrophobic nature. The adhesion and friction properties between tip and SAM surfaces under nano scale applied load were measured using an atomic force microscope (AFM) and also those under micro scale applied load were measured using a ball-on-flat type micro-tribotester. Surface roughness and water contact angles were measured with SPM (scanning probe microscope) and contact anglemeter respectively. Results showed that water contact angles of SAMs with the end-group of fluorine show higher relatively than those of hydrogen. SAMs with the end-group of fluorine show lower nano-adhesion but higher micro/nanofriction than those with hydrogen. Water contact angles of SAMs coated by CVD method show high values compared to those by dipping method. SAMs coated by CVD method show the increase of nano-adhesion but the decrease of nano-friction. Nano-adhesion and friction mechanism of SAMs with different end-group was proposed in a view of size of fluorocarbon molecule.

Buckling resistance, bending stiffness, and torsional resistance of various instruments for canal exploration and glide path preparation

  • Kwak, Sang-Won;Ha, Jung-Hong;Lee, WooCheol;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.270-275
    • /
    • 2014
  • Objectives: This study compared the mechanical properties of various instruments for canal exploration and glide-path preparations. Materials and Methods: The buckling resistance, bending stiffness, ultimate torsional strength, and fracture angle under torsional load were compared for C+ file (CP, Dentsply Maillefer), M access K-file (MA, Dentsply Maillefer), Mani K-file (MN, Mani), and NiTiFlex K-file (NT, Dentsply Maillefer). The files of ISO size #15 and a shaft length of 25 mm were selected. For measuring buckling resistance (n = 10), the files were loaded in the axial direction of the shaft, and the maximum load was measured during the files' deflection. The files (n = 10) were fixed at 3 mm from the tip and then bent $45^{\circ}$ with respect to their long axis, while the bending force was recorded by a load cell. For measuring the torsional properties, the files (n = 10) were also fixed at 3 mm, and clockwise rotations (2 rpm) were applied to the files in a straight state. The torsional load and the distortion angle were recorded until the files succumbed to the torque. Results: The CP was shown to require the highest load to buckle and bend the files, and the NT showed the least. While MA and MN showed similar buckling resistances, MN showed higher bending stiffness than MA. The NT had the lowest bending stiffness and ultimate torsional strength (p < 0.05). Conclusions: The tested instruments showed different mechanical properties depending on the evaluated parameters. CP and NT files were revealed to be the stiffest and the most flexible instruments, respectively.

Fracture Behavior of Polycarbonate/Polyestercarbonate Blends (폴리카보네이트/폴리에스터카보네이트 블렌드의 파괴 거동)

  • Lee, Yong-Bum;Lee, Choon-Soo;Kim, Dae-Sik;Kim, Jong-Hyun;Jho, Jae-Young;Lee, Sang-Soo
    • Polymer(Korea)
    • /
    • v.35 no.6
    • /
    • pp.537-542
    • /
    • 2011
  • Fracture behaviors of polycarbonate (PC)/polyestrercarbonate (PEC) blends and their miscibility have been examined to find out the mechanism of ductilie-brittle transition of fracture behavior which would be a main governing factor on the thickness sensitivity of impact strength of PC. $T_g$ measurement showed that PEC with a carbonate content higher than 30 mol% was miscible with PC. In the notched Izod impact test of PC, ductile-brittle transition occurred in the range of 4 to 5 mm thickness. The impact strength of miscible PC/PEC5 blends ductile-fractured in the thin specimens decreased with increasing PEC5 content, which was in accordance with the decrease of elongation at break in tensile test. In the brittle fracture of the thick specimens, the impact strength was well correlated with the plastic zone size in the vicinity of the notch tip.

A practical approach to nasal reconstruction in Asian patients

  • Koh, In Suk;Sun, Hook
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.5
    • /
    • pp.268-275
    • /
    • 2021
  • Background: The study aimed to evaluate nasal reconstruction techniques customized for Asians. The currently available nasal reconstruction guidelines are based on Caucasian patients, and their applicability is limited in Asian patients due to differences in anatomical and structural features. Methods: A retrospective analysis was performed of the medical records of 76 patients who underwent nasal reconstruction at a single center between January 2010 and June 2020. A comprehensive evaluation was conducted of patients' baseline demographics and clinical characteristics, including age, sex, medical history, defect size and location, reconstructive procedure, pathological diagnosis, postoperative complications, and recurrence. Results: In 59 cases (77%), nasal defects resulted from tumor ablation, and the remaining 17 cases involved post-traumatic (20%) and infection-induced (3%) tissue damage. The most common defect location was the alae, followed by the sidewalls, tip, and dorsum. Forehead flaps were the most commonly used reconstructive technique, followed by nasolabial advancement flaps, rotation flaps, and skin grafts. Each procedure was applied considering aspects of structural anatomy and healing physiology specific to Asians. Complications included nasal deformity, hypertrophic scarring, secondary infection, and partial flap necrosis, but no cases required additional surgical procedures. Tumors recurred in two cases, but tumor recurrence did not significantly affect flap integrity. Conclusion: Nasal reconstruction techniques applied considering Asians' facial features resulted in fewer postoperative complications and higher patient satisfaction than the approaches that are currently in widespread use. Therefore, this study is expected to serve as an essential reference for establishing treatment guidelines for nasal reconstruction in Asians.

Change in nostril ratio after cleft rhinoplasty: correction of nostril stenosis with full-thickness skin graft

  • Suh, Joong Min;Uhm, Ki Il
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.2
    • /
    • pp.85-92
    • /
    • 2021
  • Background: Patients with secondary deformities associated with unilateral cleft lip and nose might also suffer from nostril stenosis due to a lack of tissue volume in the nostril on the cleft side. Here, we used full-thickness skin grafts (FTSGs) to reduce nostril stenosis and various methods for skin volume augmentation. We compared the changes in the symmetry of both nostrils before and after surgery. Methods: From February 2016 to January 2020, 34 patients underwent secondary cheiloplasty and open rhinoplasty for secondary deformities of the unilateral cleft lip and nose with nostril stenosis. FTSG was used on the nostril floor, nasal columella, and alar inner lining. The measured nasal profile included the nostril surface, nostril circumference, width of the nostril floor, and distance from the alar-facial groove to the nasal tip. The "overlap area," which was defined as the largest overlapping area when the image of the cleft nostril was flipped to the left and right and overlaid on the image of the normal side nostril, was also calculated. The degree of symmetry was evaluated by dividing the value of the cleft side by that of the normal side of each measured profile and expressed as "ratios." Results: The results of all profile ratios, except for the nostril floor width, became significantly close to 1, which represents full symmetry. The overlap area ratio improved from 62.7% to 77.3%, meaning that the length and width of the nostril as well as the overall shape became similar (p< 0.05). Conclusion: When performing cleft rhinoplasty with nostril stenosis, FTSG is useful to achieve symmetry in the nostril size and shape. Skin grafting is simpler to perform than the other types of local flap, and the results are generally satisfactory.