• 제목/요약/키워드: Tip Test

검색결과 817건 처리시간 0.028초

광학추적항법장치를 이용한 르포씨 제1형 골절단 가상 수술의 정확성에 대한 연구 (Accuracy of simulation surgery of Le Fort I osteotomy using optoelectronic tracking navigation system)

  • 부연지;김성민;김지연;박정민;명훈;이종호;김명진
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권2호
    • /
    • pp.114-121
    • /
    • 2011
  • Introduction: The aim of this study was to demonstrate that the simulation surgery on rapid prototype (RP) model, which is based on the 3-dimensional computed tomography (3D CT) data taken before surgery, has the same accuracy as traditional orthograthic surgery with an intermediate splint, using an optoelectronic tracking navigation system. Materials and Methods: Simulation surgery with the same treatment plan as the Le Fort I osteotomy on the patient was done on a RP model based on the 3D CT data of 12 patients who had undergone a Le Fort I osteotomy in the department of oral and maxillofacial surgery, Seoul National University Dental Hospital. The 12 distances between 4 points on the skull, such as both infraorbital foramen and both supraorbital foramen, and 3 points on maxilla, such as the contact point of both maxillary central incisors and mesiobuccal cuspal tip of both maxillary first molars, were tracked using an optoelectronic tracking navigation system. The distances before surgery were compared to evaluate the accuracy of the RP model and the distance changes of 3D CT image after surgery were compared with those of the RP model after simulation surgery. Results: A paired t-test revealed a significant difference between the distances in the 3D CT image and RP model before surgery.(P<0.0001) On the other hand, Pearson's correlation coefficient, 0.995, revealed a significant positive correlation between the distances.(P<0.0001) There was a significant difference between the change in the distance of the 3D CT image and RP model in before and after surgery.(P<0.05) The Pearson's correlation coefficient was 0.13844, indicating positive correlation.(P<0.1) Conclusion: Theses results suggest that the simulation surgery of a Le Fort I osteotomy using an optoelectronic tracking navigation system I s relatively accurate in comparing the pre-, and post-operative 3D CT data. Furthermore, the application of an optoelectronic tracking navigation system may be a predictable and efficient method in Le Fort I orthognathic surgery.

다양한 거칠기의 알루미늄 옥사이드(Al2O3) 연마석을 이용한 치주기구 날 세우기의 효율성 비교 (Comparing the efficiency of periodontal instrument sharpening using aluminum oxide stones with different levels of roughness)

  • Kim, Yong-Gun
    • 구강회복응용과학지
    • /
    • 제30권2호
    • /
    • pp.131-137
    • /
    • 2014
  • 목적: 이 연구는 다양한 거칠기를 가진 알루미늄 옥사이드 연마석으로 치주기구 날 세우기를 시행시 연마석의 거칠기에 따른 치주기구 날 세우기의 효율성 및 마모도를 비교 평가하였다. 연구 재료 및 방법: 30개의 No. 9 - 10 그레이시 큐렛이 사용되었고, 모든 큐렛은 치석제거술 및 치근활택술을 시행함으로써 날을 무디게 만들고 3가지 그룹(240, 600, 800 grit)으로 임의로 나누었다. 치주기구의 예민도는 연마석을 최대 20회 기구에 적용한 후 평가되었고, 마모도는 최대 80회 후 기구 날의 끝 1 mm와 2 mm에서 기구 날의 폭으로 평가되었다. 결과: 치주기구 예민도는 5회와 10회 상하 운동시 240 grit에서 유의하게 높게 나타났으며(P < 0.001), 15회, 20회에서는 유의한 차이는 없었다(P > 0.05). 마모도는 240 grit의 경우 600 grit과 800 grit에 비해 약간 높게 나타났지만 통계적 유의성은 없었다. 결론: 알루미늄 옥사이드 연마석의 입자가 클수록 치주기구 날 세우기의 효율성은 증가하였다. 하지만 기구의 마모에 유의해야 한다.

실험적으로 유도된 백서의 치수염에서의 INTERLEUKIN-6와 INTERLEUKIN-10의 농도와 분포에 관한 연구 (Interleukin-6 and Interleukin-10 in experimentally induced rat Pulpal inflammation)

  • 장석우;백승호;김철호;임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.232-238
    • /
    • 2002
  • 연구목적 : Cytokine은 유해 미생물에 대한 숙주의 방어기전으로서의 염증반응에서 숙주세포 상호간의 작용을 매개해 주는 역할을 하며, 인간의 치수조직에서도 그 존재가 확인된 바 있다. Interleukin-6와 Interleukin-10은 염증의 초기에 작용하는 cytokine으로 알려져 있으나, 치수 및 치근단 질환에서의 역할과 상호작용에 대해서는 잘 알려져 있지 않다. 본 연구에서는 치수염의 원인균으로 알려진 Prevotella nigrescens를 이용하여 백서의 치수염을 유도한 후 시간의 변화에 따른 Interleukin-6, Interleukin-10의 농도의 변화를 측정하여 이들의 치수염에서의 작용을 알아보는 것을 목적으로 한다. 방법 : 실험적으로 치수의 염증반응을 일으키기 위하여 치수염의 원인균으로 알려진 Prevotella nigrescens를 이용하였다. 실험동물의 하악절치의 incisal tip부분을 절단한 후(n=120), 치수강을 개방시켰다. 실험군에서는 Prevotella nigrescens를 멸균된 면구에 묻혀서 개방된 치수강 내에 접종하였으며, 대조군에서는 균을 접종하지 않고 멸균된 면구만을 개방된 치수강 내에 위치시켰다. 그 후 1, 2, 5일이 경과되었을 때 실험에 사용된 치아를 발치하여, 치수조직을 적출하였다. Amersham사의 ELISA kit를 사용하여 적출된 치수조직내의 Interleukin-6와 Interleukin-10의 양을 측정하였으며 그 결과를 Mann-Whitney rank sum test를 사용하여 통계학적 유의성을 검증하였다. 조직학적 검사를 위해서는 발치된 치아를 nitric acid를 사용하여 탈회시킨 후 헤마톡실린-에오신 염색을 시행한 후 관찰하였다. 결과 : 1) Interleukin-6의 농도는 균접종 후 1일, 2일, 5일 모두에서 실험군에서 대조군보다 높게 나타났으며, 균접종 1일째의 결과는 통계적 유의성이 있었다(P<0.05). 2) Interleukin-10의 농도는 균접종 후 1일, 2일, 5일 모두에서 실험군에서 대조군보다 높게 나타났으며, 균접종 1일째의 결과는 통계적 유의성이 있었다(P<0.05). 3) Interleukin-10/1nterleukin-6 ratio는 실험군과 대조군 모두에서 1일보다 2일째의 결과에서 더 높은 값을 보였으며 대조군에서는 통계적 유의성을 보였다(P<0.05). 4)조직학적 관찰결과 균접종 후 2일째의 조직표본에서는 림프구의 침윤과 부분적인 조직의 괴사 등 염증반응의 양상을 관찰할 수 있었으며, 균접종 5일째의 조직표본에서는 염증의 정도가 감소되는 양상을 확인할 수 있었다.

먹이트랩을 이용한 복숭아순나방[Grapholita molesta (Busck)]의 교미교란제 효과 검정 (Efficacy Test of Mating Disruptors Using Food Trap of Oriental Fruit Moth, Grapholita molesta (Busck))

  • 김용균;배성우;최경희;이동혁;이순원
    • 한국응용곤충학회지
    • /
    • 제46권2호
    • /
    • pp.269-274
    • /
    • 2007
  • 본 연구는 복숭아순나방(Grapholita molesta (Busck))의 상용 교미교란제가 사과원에서 미치는 교미교란 효과를 분석하기 위해 먹이트랩으로 암컷을 채집하여 교미율을 결정하였다. 복숭아순나방 월동집단을 대상으로 세 종류의 교미교란제가 비교되었으며, 교미교란 효과는 수컷 유인력 감소, 신초피해 및 암컷 교미율을 상호 비교하였다. 야외 암컷은 테르피닐아세테이트 트랩에 수컷과 함께 유인되었다. 수컷의 정자주머니는 암컷의 교미낭과 유사한 크기를 가졌다. 교미교란제가 처리된 지역은 95% 이상의 수컷 유인력 저하를 나타냈으나, 사과의 신초 피해가 발생하였다. 한편 교미교란제가 처리된 지역에서 채집된 암컷의 교미율은 약 35% 이상을 나타내었다. 본 연구는 교미교란제 효능 분석에 수컷의 유인력 감소보다는 암컷의 교미율 판정이 보다 교미교란 효과를 작물피해로 연결시키는데 의미가 있다는 것을 보여주었다.

투명 fiber 포스트를 통한 광중합형 접착레진의 중합 반응 (CURING REACTION OF THE LIGHT CURED FLOWABLE COMPOSITE RESINS THROUGH THE ENDODONTIC TRANSLUCENT FIBER POST)

  • 안석;박상원;양홍서;방몽숙;박하옥
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.1-9
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the efficacy and substitute possibility of a newly developed flowable composite resins as a luting cement for translucent fiber post. Material & Method: Two kinds of 12 mm translucent fiber Post (D.T. Light-Post (Bisco, USA) and FRC Postec (Ivoclar vivadent, Liechtenstein) was inserted into the teflon mold (7 mm diameter, 9 mm long) and Filtek-Flow (3M ESPE. USA), a light activated flowable composite resin, was polymerized for 60 seconds through the post. Also, the post was cut from the tip to 9 mm, 6 mm, 3 mm, and Filtek-Flow was light cured according to each length. For comparison, 60 seconds light-cured and 24 hours self-cured two dual cured resin cement (Duo-cement (Bisco, USA) and 2 Panavia-F (Kuraray, Japan)) samples were prepared as control group. Also cavities (1 mm in width, 1 mm in depth and 12 mm in length) were prepared using acrylic plate and aluminum bar, and flowable composite resin was flied and light cured by the diffused light from the fiber post's side wall. The degree of polymerization was measured according to the distance from curing light using Vickers' hardness test. Result: Within the limitation of this study, the following conclusions were drawn: 1. Vickers' hardness of light cured dual cured resin cement and flowable composite resin decreased from Panavia-F, Filtek-Flow and Duo-cement accordingly (p<0.05). In the dual curing resin cement, light curing performed group showed higher surface hardness value than self cured only group (p<0.05). 2. Surface hardness ratio (light cured through fiber post /directly light cured) of D.T. Light-Post using Filtek-Flow showed about 70% in the 6 mm deep and about 50% in the 12 mm deep FRC Postec showed only 40% of surface hardness ratio. 3. Surface hardness ratio by diffused light from the post's side wall showed about 50% at 6 mm and 9 mm deep, and about 40% at 12 mm deep in D.T. Light-Post. However, FRC Postec showed about 40% at 6 mm deep, and almost no polymerization in 9 mm and 12 mm deep.

유한요소법을 이용한 전부주조관의 교합점 위치와 하중방향이 시멘트층 내 응력에 미치는 영향 (Characterization of the Stresses in the Luting Cement Layer Affected by Location of the Occlusal Points and Loading Direction on a Full Veneer Crown)

  • 이정훈;이규복;이청희;조광헌
    • 구강회복응용과학지
    • /
    • 제24권4호
    • /
    • pp.317-324
    • /
    • 2008
  • 이 논문의 목적은 전부주조관에서 교합점의 위치와 교합력의 방향이 합착용 시멘트층 내의 응력에 미치는 영향에 대해서 알아보는 것이다. 하악 제 1대구치상에서 서로 다른 9 개의 교합점과 3가지 교합력 방향을 가진 27가지 조합의 유한요소 모델을 상정하였다. 금관의 소재는 제 3형 금합금이고, 변연의 형태는 chamfer이다. 합착용 시멘트로는 전 층에서 균일하게 $70{\mu}m$의 두께를 가지는 글라스 아이오노머 시멘트가 사용되었다. 금관에는 100N의 하중을 적용하였다. 협측과 설측 변연의 근접도에 따라서 시멘트층 내 응력은 다른 양상을 나타내었다. 협측은 변연으로부터 약 0.5 mm, 설측은 변연으로부터 약 1 mm 내측에서 최대 응력 값을 가졌다. 하중 방향이 치축에 대해 경사가 클수록, 하중점이 교두첨에 근접해 있을수록 더 큰 응력이 발생하였다.

LNG선박용 열교환기 세관의 SCC에 미치는 응력의 영향 (The Effect of Stress on SCC of Heat Exchanger Tube for LNG Vessel)

  • 정해규;임우조
    • 한국가스학회지
    • /
    • 제7권2호
    • /
    • pp.22-32
    • /
    • 2003
  • Al-황동은 기계적 특성 및 열전도성이 우수하고 해수 중에서 표면 보호피막을 형성하므로 부식저항성이 높아 해수를 냉각수로 사용하는 선박용 열교환기의 세관재로 널리 사용되고 있다 Al-황동 세관은 실제 사용 환경에서 굽힘 등에 의한 소성변형된 상태로 사용되는 경우가 많다. 이와 같은 소성변형에 의한 Al-황동 세관의 균열 파손사례는 선박의 오일탱크 내의 가열코일, 각종 열교환기의 세관 등에서 흔히 찾아 볼 수 있다. 또한 세관의 확관에 의한 밀봉 방법에 따라 세관의 변형에 의한 잔류응력 및 어패류 혼입에 의한 해수 유입부의 국부적인 유속증가 등에 기인하여 Al-황동 세관의 균열 및 침식 등의 파손사례가 보고되고있다. 본 연구에서는 $3.5\%$ NaCl. + $0.1\%\;NH_4OH$ 수용액을 시험편 표면에 5 m/s로 액분사하의 가속실험에서 Al-황동 세관의 응력부식균열 거동에 미치는 응력의 영향에 대하여 고찰하였다.

  • PDF

선박 추진시스템 유동 소음원 상대적 기여도 분석 (Investigation on relative contribution of flow noise sources of ship propulsion system)

  • 하준범;구가람;정철웅;설한신;정홍석;정민석
    • 한국음향학회지
    • /
    • 제41권3호
    • /
    • pp.268-277
    • /
    • 2022
  • 본 논문에서는 KVLCC2 선체 축소모형에 설치된 추진시스템의 세부 구성품별 유동 소음원을 분석하였으며, 각각의 소음원이 수중방사소음에 미치는 영향에 대해 정량적으로 분석하였다. 수치 해석 영역은 실험 결과와의 비교를 위하여 선박해양플랜트연구소 대형 캐비테이션 터널의 시험부와 동일하게 설정하였다. 먼저 유동장내 소음원을 정확하게 모사하기 위하여 고정밀 해석기법인 비압축성 다상 Delayed Detached Eddy Simulation 방법을 적용하였고, 유동해석 결과를 기반으로 Ffowcs Williams and Hawkings 적분방정식을 사용하여 수중방사소음을 예측하였으며, 터널 실험결과와의 비교를 통해 해석절차의 유효성을 확인하였다. 추진시스템의 유동 소음원별 영향을 정량적으로 비교하기 위하여 추진기 날개 끝-와류 공동, 날개 표면 그리고 방향타 표면을 소음원 영역으로 선정하였으며, 음압과 파워 스펙트럼 밀도, 음향 파워를 비교하였다. 공동에 의한 홀극 소음원의 기여도가 추진기 날개 및 방향타에 의한 쌍극 소음원에 비해 수중방사소음에 크게 기여하였으며, 추진기 후류의 영향으로 방향타에 의한 기여도가 추진기 보다 더 크게 발생함을 확인하였다.

간극수압비를 이용한 부산점토의 CPTu 콘계수 추정 (Evaluation of CPTu Cone Factors for Busan Clay Using Pore Pressure Ratio)

  • 홍성진;이문주;김태준;이우진
    • 한국지반공학회논문집
    • /
    • 제25권1호
    • /
    • pp.77-88
    • /
    • 2009
  • 본 연구에서는 부산지역 점토의 비 배수전단강도를 추정하기 위해 현장 및 실내시험을 통해 부산점토의 콘계수를 평가하였다. 이를 위해 부산신항 지역 및 녹산지역에서 $CK_0U$ 삼축압축시험, 베인전단시험, 피에조 콘 관입시험(CPTu) 등을 실시하였다. 시험결과, 현장 점토의 비배수전단강도는 심도에 따라 증가하였으며, 강도증가비는 각각 $S_{u(CKU)}/{\sigma}'_v\;{\fallingdotseq}\;0.26{\sim}0.44$${\mu}_{su(VST)}/{\sigma}'_v\;{\fallingdotseq}\;0.20{\sim}0.23$로 삼축 비배수전단강도가 베인 비배수전단강도에 비해 1.5배 정도 크게 나타났다. 또한 CPTu 시험결과 콘선단저항($q_c$)과 간극수압($u_2$)은 심도에 따라 증가하였으며, 간극수압비($B_q$)는 $0.3{\sim}1.0$정도로 나타났다. 삼축압축 및 베인시험 결과와 CPTu 결과로부터 콘계수를 산정한 후 간극수압비와 비교한 결과, 삼축 비배수전단강도와 베인 비배수전단강도를 추정하기 위한 부산지역 점토의 콘계수는 각각 $5{\sim}20$, $10{\sim}35$로 나타났다. 그리고 콘계수는 간극수압비가 증가함에 따라 선형적으로 감소하였으며, 이로부터 간극수압비를 이용한 부산점토 콘계수 추정방법을 제안하였다.

연약지반 평가를 위한 블레이드 타입 현장 전단파 속도 프로브 (Blade Type Field Vs Probe for Evaluation of Soft Soils)

  • 윤형구;이창호;엄용훈;이종섭
    • 한국지반공학회논문집
    • /
    • 제23권12호
    • /
    • pp.33-42
    • /
    • 2007
  • 연약지반의 강성평가는 샘플링(sampling)과 현장 접근에 따른 교란으로 인해 정확하게 평가하는 것이 상당히 어렵다. 이를 위해 개발된 링 타입 FVP를 이용하여 부산 신항에서 실험이 수행 되었다. 이 논문의 목적은 지반 관입시 발생하는 교란을 최소화 할 수 있도록 기존의 링 타입 FVP를 블레이드 타입 FVP로 개량하는 것이다. 블레이드 타입 FVP는 하단의 웨지 모양, 시료 교란, 트랜스듀서, 케이블의 보호, 그리고 케이블과 트랜스듀서간의 전자기적 커플링을 고려하여 설계하였다. 케이블 간 누화현상은 케이블의 접지와 통합을 통해 제거 할 수 있었다. FVP의 전단파 속도는 초기 도달 시간과 이동거리를 이용하여 간단하게 계산될 수 있었다. FVP 블레이드의 관입에 의한 교란 효과 조사 및 FVP를 통해 측정된 전단파 속도의 타당성을 확인하기 위하여 실내 대형 calibration 챔버를 이용하여 비교 시험을 수행하였다. 블레이드 타입 FVP는 30m 깊이까지 측정이 되었으며, 전단파 속도는 매 심도 10cm마다 측정이 되었다. 본 논문에서 제시된 개량된 블레이드 타입의 FVP는 대상 지반의 교란을 최소화 시키며 현장에서 직접 전단파 속도를 측정 할 수 있는 효과적인 장비라고 할 수 있다.