• Title/Summary/Keyword: Timer

Search Result 380, Processing Time 0.027 seconds

Monitoring of Misfiring Status of Ship Engines Using Minute Speed Changes in the Crankshaft (크랭크축의 미세속도변화를 이용한 선박엔진의 착화불량 상태 감시)

  • Kang, Ho Hyeon;Ahn, Jung Hwan;Kim, Hwa Young
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.51-56
    • /
    • 2022
  • In this study an efficient method for detecting and monitoring engine misfiring, focusing on minute speed changes in the crankshaft is proposed., Its validity is verified using various misfiring cases. Typically, the crankshaft speed fluctuates around the normal value depending on the engine misfiring status. Even a minute speed change in the crankshaft can be estimated by measuring the rotation time of each tooth of the 118-tooth flywheel attached to the crankshaft with a 2-MHz timer. Therefore, a speed pattern for an in-line six-cylinder engine consists of 236 tooth rotation speeds corresponding to the two rotations of the crankshaft, in which all the cylinders complete four-stroke cycle. FFT analysis can reduce the number of components of a speed pattern from 236 to just four major components: - fundamental frequency_(f), 2f, 3f, 6f., - This makes the comparison of the misfiring cases simpler and faster. In the experiment, five engine status cases (one normal firing and, four misfiring cases) were simulated. While the 6f component was the largest for the normal case, the f component increased as misfiring occurred one, two apart, and two consecutive times. The 3D FFT pattern comprising the ratio of f, 2f, and 3f, 6f showed that the distance between the misfiring and normal states was larger

A Study on the Fire Risk of High-voltage Cables for Electrical Vehicles (전기차용 고전압 케이블의 화재 위험성에 관한 연구)

  • Sin Dong Kang;Ye Jin Park;Si Hyun Kim;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.8-14
    • /
    • 2023
  • This study presents the characteristics of short circuits (SCs) caused by excessive currents in high-voltage cables used in electric vehicles and emphasizes the need to calculate the cross-sectional areas of these cables according to the SC current. Three direct current power supplies were connected in parallel to test the SC characteristics caused by excessive currents, and a timer and a magnetic contactor were used to deliver the conduction time and SC current. A circular infrared-radiation heater was used to test the temperature-dependent SC characteristics, a thermocouple was used to measure the temperature, and a shunt resistor was used to measure the current. As the SC current increased, the fusing time of the cable decreased. Additionally, a high-voltage cable (with an area of 16 mm2 ) used in electric vehicles fused when a current (approximately equal to 55 times the allowable current) flowed for 0.2 s (operating time of the protective device). When the SC current is 10 kA, the cable may fuse during the operating time of the protective device, thus creating a fire hazard. In electric vehicles, the size of the SC current increases in proportion to the capacity of the battery. Thus, the cross-sectional areas of the cables used should be calculated accordingly, and cable operations should be properly coordinated with the surrounding protective devices.

A Non-Linear Overload Control Scheme for SIP Proxy Queues (SIP 프록시 큐의 비선형적 과부하 제어 방법)

  • Lee, Jong-Min;Jeon, Heung-Jin;Kwon, Oh-Jun
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.4
    • /
    • pp.43-50
    • /
    • 2010
  • Recently, the Internet telephony has been used rather than the traditional telephony by many Internet users, with low cost. Session Initiation Protocol(SIP) is the standard of application layer protocol for establishment and disconnection of the session for Internet telephony. SIP mainly runs over the UDP for transport. So in case of the loss of the INVITE request message, the message is retransmitted by an appropriate timer for reliable transmission of the UDP message. Though the retransmission is useful for ensuring the reliability of SIP messages sent by the users, it may cause the overload traffic in the SIP proxy server. The overload in SIP proxy servers results in the loss of many input messages. This paper presents a non-linear overload control algorithm to resolve the overload condition of the server. we simulate our proposed algorithm using the network simulator ns-2. The simulation results show that the throughput of the server with the proposed algorithm have been improved about 12% compared to the existing linear control algorithm.

Implementation of cusomized RFID receiver module for In-VIVO wireless transmission (체내심부 무선전송을 위한 맞춤형 RFID 수신 모듈 구현)

  • An, Jinyoung;Sa, Gi-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.55-57
    • /
    • 2022
  • In this study, a customized semi-passive RFID receiver module was implemented for in-VIVO deep tissue photo-therapy. A novel wireless technique is required due to a limitation of RF communication in body environment, as internal body has a complex structure such as, skin, fat, skeleton, water, and so on. Recently, coherently incoherent beamforming (CIB) based on RFID was introduced and it is able to transmit wireless signal with high reliability under the incoherent condition such as in-VIVO deep tissue. The proposed miniature photo capsule based on RFID consists of miniature controller, ultra small LED array and wireless RFID chip. RF Reader can access with standard RFID protocol (ISO 18000-6c) using UHF RFID antenna, a control command is wirelessly writtern on USER Bank memory. With received control command, therapy LED array dims with mulilevel under timer control. The signal process of designed RFID photo therapy capsule is analyzed and evaluated under the various environments in detailed.

  • PDF

C4orf47 is a Novel Prognostic Biomarker and Correlates with Infiltrating Immune Cells in Hepatocellular Carcinoma

  • Hye-Ran Kim;Choong Won Seo;Sang Jun Han;Jongwan Kim
    • Biomedical Science Letters
    • /
    • v.29 no.1
    • /
    • pp.11-25
    • /
    • 2023
  • In hepatocellular carcinoma (HCC), chromosome 4 open-reading frame 47 (C4orf47) has not been so far investigated for its prognostic value or association with infiltrating immune cells. We performed bioinformatics analysis on HCC data and analyzed the data using online databases such as TIMER, UALCAN, Kaplan-Meier plotter, LinkedOmics, and GEPIA2. We found that C4orf47 expression in HCC was higher compared to normal tissues. High C4orf47 expression was associated with a worse prognosis in HCC. The correlation between C4orf47 and infiltrating immune cells is positively associated with CD4+T cells, B cells, neutrophils, macrophages, and dendritic cells in HCC. Moreover, high C4orf47 expression was correlated with a poor prognosis of infiltrating immune cells. Analysis of C4orf47 gene co-expression networks revealed that 12501 genes were positively correlated with C4orf47, whereas 7200 genes were negatively correlated. The positively related genes of C4orf47 are associated with a high hazard ratio in different types of cancer, including HCC. Regarding the biological functions of C4orf47 gene, it mainly regulates RNA metabolic process, DNA replication, and cell cycle. The C4orf47 gene may play a prognostic role by regulating the global transcriptome process in HCC. Our findings demonstrate that high C4orf47 expression correlates with poor prognosis and tumor-infiltrating immune cells in HCC. We suggest that C4orf47 is a novel prognostic biomarker and potential immune therapeutic target for HCC.

A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus (전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구)

  • Hansol Jang;U-Ryeong Chung;Jeong-Hyun Moon;Seong-Kyeong Choi;Won-Suk Sung;Min-Seop Hwang;Seung-Deok Lee;Kyung-Ho Kim;Jong-Hwa Yoon;Eun-Jung Kim
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.150-163
    • /
    • 2022
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

Bioinformatic analyses reveal the prognostic significance and potential role of ankyrin 3 (ANK3) in kidney renal clear cell carcinoma

  • Keerakarn Somsuan;Siripat Aluksanasuwan
    • Genomics & Informatics
    • /
    • v.21 no.2
    • /
    • pp.22.1-22.15
    • /
    • 2023
  • Kidney renal clear cell carcinoma (KIRC) is one of the most aggressive cancer type of the urinary system. Metastatic KIRC patients have poor prognosis and limited therapeutic options. Ankyrin 3 (ANK3) is a scaffold protein that plays important roles in maintaining physiological function of the kidney and its alteration is implicated in many cancers. In this study, we investigated differential expression of ANK3 in KIRC using GEPIA2, UALCAN, and HPA databases. Survival analysis was performed by GEPIA2, Kaplan-Meier plotter, and OS-kirc databases. Genetic alterations of ANK3 in KIRC were assessed using cBioPortal database. Interaction network and functional enrichment analyses of ANK3-correlated genes in KIRC were performed using GeneMANIA and Shiny GO, respectively. Finally, the TIMER2.0 database was used to assess correlation between ANK3 expression and immune infiltration in KIRC. We found that ANK3 expression was significantly decreased in KIRC compared to normal tissues. The KIRC patients with low ANK3 expression had poorer survival outcomes than those with high ANK3 expression. ANK3 mutations were found in 2.4% of KIRC patients and were frequently co-mutated with several genes with a prognostic significance. ANK3-correlated genes were significantly enriched in various biological processes, mainly involved in peroxisome proliferator-activated receptor (PPAR) signaling pathway, in which positive correlations of ANK3 with PPARA and PPARG expressions were confirmed. Expression of ANK3 in KIRC was significantly correlated with infiltration level of B cell, CD8+ T cell, macrophage, and neutrophil. These findings suggested that ANK3 could serve as a prognostic biomarker and promising therapeutic target for KIRC.

Implementation of Yoga Posture Training Application Using Google ML Kit (Google ML Kit를 이용한 요가 자세 훈련 애플리케이션 구현)

  • Kim, Hyoung Min;Yoon, Jong Hyeon;Park, Su Hyun;Yu, Yun Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.178-180
    • /
    • 2022
  • An application implementation that allows users to train yoga posture based on the landmark of yoga posture of yoga instructors obtained from the Google Firebase ML Kit was introduced. Using the ML Kit, the user's posture is classified and landmarks corresponding to each joint are obtained. The accuracy measurement reference value for the yoga posture is set through the angle formed by the joints of the obtained landmark. The accuracy between the reference landmark for the yoga posture of professional yoga instructors and the landmark for the user's pose through the ML Kit was compared. According to the accuracy reference value, information on malfunction and correct motion is provided to the user through Text-to-Speech (TTS). Users are managed effectively with Firebase, and a system that displays the amount of exercise through a counter and timer when the user performs an exercise that meets the accuracy reference value was explained.

  • PDF

A Study on the X-ray Image Reading of Radiological Dispersal Device (방사능 폭발물의 X-ray 영상판독에 관한 연구)

  • Geun-Woo Jeong;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.2_2
    • /
    • pp.437-443
    • /
    • 2024
  • The purpose of radiological Dispersal Device(RDD) is to kill people by explosives and to cause radiation exposure by dispersing radioactive materials. And It is a form of explosive that combines radioactive materials such as Co-60 and Ir-192 with improvised explosives. In this study, we tested and evaluated whether it was possible to read the internal structure of an explosive using X-rays in a radioactive explosive situation. The improvised explosive device was manufactured using 2 lb of model TNT explosives, one practice detonator, one 9V battery, and a timer switch in a leather briefcase measuring 41×35×10 cm3. The radioactive material used was the Co-60 source used in the low-level gamma ray irradiation device operated at the Advanced Radiation Research Institute of the Korea Atomic Energy Research Institute. The radiation dose used was gamma ray energy of 1.17 MeV and 1.33 MeV from a Co-60 source of 2208 Ci. The dose rates are divided into 0.5, 1, 2, and 4 Gy/h, and the exposure time was divided into 1, 3, 5, and 10 minutes. Co-60 source was mixed with the manufactured explosive and X-ray image reading was performed. As a result of the experiment, the X-ray image appeared black in all conditions divided by dose rate and time, and it was impossible to confirm the internal structure of the explosive. This is because γ-rays emitted from radioactive explosives have higher energy and stronger penetrating power than X-rays, so it is believed that imaging using X-rays is limited By blackening the film. The results of this study are expected to be used as basic data for research and development of X-ray imaging that can read the internal structure of explosives in radioactive explosive situations.

The effects of continuous and intermittent compressive pressure on alkaline phosphatase activity of MC3T3-E1 cells (지속적 및 간혈적 가압력이 MC3T3-E1 세포의 Alkaline phosphatase 활성도에 미치는 영향)

  • Song, Hye-Seob;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.449-454
    • /
    • 1996
  • The propose of this study was to evaluate the difference of cellular activity dependent on intermittent compressive force by determining the alkaline phosphatase activity. Alkaline phosphatase activity was measured on control and experimental groups every 24, 48, 72hours. Experimental groups consisted of continous and intermittent compressive group which were compressed by $300gm/cm^2$ of diaphram pump. The intermittent compressive group was connected by timer which was worked on 10 minutes an off 10 minutes. The results were as follows; 1. The alkaline phosphatase activity between control and experimental groups showed not significant difference at compressed 24 hours. 2. The alkaline phosphatase activity of experimental groups were more increased than control group at compressed 48 hours. 3. The alkaline phosphatase activity of intermittent compressive group showed significant increased to control group. Whereby continuous compressive group showed not significant difference to control at 72 hours. 4. The alkaline phosphatase activity of intermittent compressive group were stringly increased than continuous compressive groups. 5. Between experimental groups and control group no other morphologic changes were detected by microscopic findings.

  • PDF