• 제목/요약/키워드: Time-scaling

검색결과 682건 처리시간 0.032초

H2/CO 합성가스의 난류 제트 확산화염에서 EINOx Scaling (EINOx scaling of H2/CO Syngas Non-premixed Turbulent Jet Flame)

  • 황정재;손기태;김태성;윤영빈
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.55-58
    • /
    • 2012
  • EINOx scaling for $H_2/CO$ non-premixed turbulent jet flame was conducted. NOx concentration and flame length were measured simultaneously with varying flow conditions. Flame length increases with Reynolds number which means the flames in buoyancy-momentum transition region. We assessed the previous Chen & Driscoll's scaling with present results. However, the scaling cannot satisfy the present results. We proposed new scaling which is addressed the simplified flame residence time. The new scaling satisfies the results of $H_2/CO$ syngas flame as well as pure hydrogen flames.

  • PDF

액상화 지반에 대한 1-g 모형실험과 원심모형실험의 비교 연구 (Comparison of 1-g and Centrifuge Model Tests on Liquefied Sand Grounds)

  • 김성렬;황재익;;김명모
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.97-104
    • /
    • 2006
  • The centrifuge and 1-g shaking table tests were performed simultaneously to compare the dynamic behaviors of loose sands of same geotechnical properties. The prototype soils were 10 m thick liquefiable loose sands. The geometric scaling factors were 20 for 1-g and 40 for centrifuge tests. The excess pore pressure, surface settlement, and acceleration in the soil were measured at the same locations in the 1-g and centrifuge tests. The total excess pore pressure from development to dissipation was measured. In the centrifuge test, viscous fluid was used as the pore water to eliminate the time scaling difference between dynamic time and dissipation time. In the 1-g tests, the steady state concept was applied to determine the unit weight of the model soil, and two different time scaling factors were applied for the dynamic time and the dissipationtime. It is concluded that the 1-g tests can simulate the excess pore pressure of the prototype soil if the permeability of the model soil is small enough to prevent dissipation of excess pore pressure during shaking and the dissipation time scaling factor is properly determined.

  • PDF

Hybrid Scaling Based Dynamic Time Warping for Detection of Low-rate TCP Attacks

  • 소원호;유경민;김영천
    • 한국통신학회논문지
    • /
    • 제33권7B호
    • /
    • pp.592-600
    • /
    • 2008
  • In this paper, a Hybrid Scaling based DTW (HS-DTW) mechanism is proposed for detection of periodic shrew TCP attacks. A low-rate TCP attack which is a type of shrew DoS (Denial of Service) attacks, was reported recently, but it is difficult to detect the attack using previous flooding DoS detection mechanisms. A pattern matching method with DTW (Dynamic Time Warping) as a type of defense mechanisms was shown to be reasonable method of detecting and defending against a periodic low-rate TCP attack in an input traffic link. This method, however, has the problem that a legitimate link may be misidentified as an attack link, if the threshold of the DTW value is not reasonable. In order to effectively discriminate between attack traffic and legitimate traffic, the difference between their DTW values should be large as possible. To increase the difference, we analyze a critical problem with a previous algorithm and introduce a scaling method that increases the difference between DTW values. Four kinds of scaling methods are considered and the standard deviation of the sampling data is adopted. We can select an appropriate scaling scheme according to the standard deviation of an input signal. This is why the HS-DTW increases the difference between DTW values of legitimate and attack traffic. The result is that the determination of the threshold value for discrimination is easier and the probability of mistaking legitimate traffic for an attack is dramatically reduced.

Evaluation of Pain Reduction and Clinical Efficacy of Feedback-Controlled Ultrasonic Scaler

  • Min-ju Kim;Hee-jung Lim;Myoung-hee Kim;Young-sun Hwang;Im-hee Jung
    • 치위생과학회지
    • /
    • 제23권2호
    • /
    • pp.176-184
    • /
    • 2023
  • Background: Recently, a piezoelectric ultrasonic scaler based on a feedback control mechanism was introduced for pain relief. This study aimed to investigate the effects of a new ultrasonic scaler in reducing pain and discomfort in adults. Methods: A newly introduced ultrasonic scaler (Master 700®) was used as the test device and a conventional ultrasonic scaler device (PIEZON®) was used as the control device. Forty-one healthy adults visited the dental clinic for dental scaling but did not undergo scaling or periodontal treatment within 6 months. Intraoral examinations were performed before scaling and 3 months later; before scaling, both devices were randomly assigned on the left or right side of each dentition (split-mouth model) and scaling was performed by a registered dental hygienist. The levels of pain and discomfort during scaling were evaluated subjectively and objectively using the visual analog scale (VAS) and physiological monitoring of the heart rate (HR), respectively. Time was measured for each device. Results: All clinical indicators, except bleeding on probing, significantly improved with both devices. The treatment times were 7 minutes, 13 minutes (control) and 6 minutes, 59 minutes (test). VAS scores for pain were 4.89±2.12 (control) and 4.58±2.77 (test) points out of 10; for noise, these were 4.68±2.33 (control) and 4.55±2.55 (test), and for vibration, the values were 4.26±2.0 (control) and 4.18±2.48 (test). HR averages were 72.34±3.39 (control) and 75.97±9.78 (test) beats/min. No statistically significant differences were observed between the devices. Conclusion:The pain, discomfort levels, and scaling time of the new piezoelectric ultrasonic scaler did not differ from those of the conventional device. Further research and development are necessary for more prominent pain-relief effects of scaling devices.

A layer-wise frequency scaling for a neural processing unit

  • Chung, Jaehoon;Kim, HyunMi;Shin, Kyoungseon;Lyuh, Chun-Gi;Cho, Yong Cheol Peter;Han, Jinho;Kwon, Youngsu;Gong, Young-Ho;Chung, Sung Woo
    • ETRI Journal
    • /
    • 제44권5호
    • /
    • pp.849-858
    • /
    • 2022
  • Dynamic voltage frequency scaling (DVFS) has been widely adopted for runtime power management of various processing units. In the case of neural processing units (NPUs), power management of neural network applications is required to adjust the frequency and voltage every layer to consider the power behavior and performance of each layer. Unfortunately, DVFS is inappropriate for layer-wise run-time power management of NPUs due to the long latency of voltage scaling compared with each layer execution time. Because the frequency scaling is fast enough to keep up with each layer, we propose a layerwise dynamic frequency scaling (DFS) technique for an NPU. Our proposed DFS exploits the highest frequency under the power limit of an NPU for each layer. To determine the highest allowable frequency, we build a power model to predict the power consumption of an NPU based on a real measurement on the fabricated NPU. Our evaluation results show that our proposed DFS improves frame per second (FPS) by 33% and saves energy by 14% on average, compared with DVFS.

지진 기록의 확대(Scaling) 기법과 압력토오 말뚝모형실험에의 적용 (Scaling Technique of Earthquake Record and its Application to Pile Load Test for Model Driven into Pressure Chamber)

  • 최용규
    • 한국지반공학회지:지반
    • /
    • 제12권2호
    • /
    • pp.19-32
    • /
    • 1996
  • 시간영역의 지진 가속도-시간 이력을 주파수 영역의 courier 진폭-주파수 이력으로 변화시키는 Trifunac의 경험적 모델을 기초로 하여 지진 관측소에서 측정된 임의 규모의 실제 지진기록들을 필요한 규모의 지진기록으로 유사화시키는 지진 확대 (scaling) 기법을 제안하였다. 또한, 지진 규모(M) 5.6의 지진기록을 이용하여 지진 규모(M) 8.0의 유사지진을 작성하여 동적 재하 시험 장치에 적용가능하도록 하였다. 지진 확대 (scaling) 기법은 MMI(modified mercalli intensity), 지진기록 부지의 조건,진앙거리,지진 가속도 성분의 방향, 해석의 신뢰도 등을 고려할 수 있으며, 다양한 지진 기록들에 적용가능하였다.유사지진은 수평방향의 성분들만을 고려하여 작성되었다. 압력토조내에 설치된 모형인장말뚝과 개단압출말뚝에 대한 유사지진 진동에 의한 동적 말뚝재하시험이 가능하였다. 정적 말뚝재하시험시 인장말뚝과 압축말뚝의 거동은 매우 상이하였는데, 인장말뚝은 2~3회의 급작스런 미끄러짐 변위를 수반하였다. 또한, 유사 지진 진동중 인장말뚝과 개단압축말뚝의 거동특성은 매우 상이하였으며, 지지력 감소특성도 크게 달랐다.

  • PDF

다이애딕 구조를 이용한 TH-PPM UWB 시스템의 성능 분석 (Performance Analysis of a TH-PPM UWB System using Dyadic Tree Structure)

  • 박중후;최진규
    • 한국인터넷방송통신학회논문지
    • /
    • 제8권3호
    • /
    • pp.87-92
    • /
    • 2008
  • In this paper, certain scaling functions are generated using the dyadic subband tree structure and applied to a time-hopping, pulse position modulation, ultra-wideband (TH-PPM UWB) system. Scaling functions can be obtained by iterating a lowpass filter at each level using a critically sampled dyadic tree. The performance of the TH-PPM UWB system employing scaling functions as the mono-cycle waveform is evaluated through computer simulations in a Rayleigh fading environment.

  • PDF

자동 양자이득 조정에 의한 퍼지 제어방식 (Fuzzy Control Method By Automatic Scaling Factor Tuning)

  • 강성호;임중규;엄기환
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2807-2810
    • /
    • 2003
  • In this paper, we propose a fuzzy control method for improving the control performance by automatically tuning the scaling factor. The proposed method is that automatically tune the input scaling factor and the output scaling factor of fuzzy logic system through neural network. Used neural network is ADALINE (ADAptive Linear NEron) neural network with delayed input. ADALINE neural network has simple construct, superior learning capacity and small computation time. In order to verify the effectiveness of the proposed control method, we performed simulation. The results showed that the proposed control method improves considerably on the environment of the disturbance.

  • PDF

Sum rate and Energy Efficiency of Massive MIMO Downlink with Channel Aging in Time Varying Ricean Fading Channel

  • Yang, Lihua;Yang, Longxiang;Zhu, Hongbo;Liang, Yan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권3호
    • /
    • pp.1098-1112
    • /
    • 2018
  • Achievable sum rate and energy efficiency (EE) are investigated for the massive multiple-input multiple-output (Massive MIMO) downlink with channel aging in the time varying Ricean fading channel. Specifically, the expression of the achievable sum rate of the system for the maximum ratio transmission (MRT) precoder with aged channel state information (CSI) in the time varying Ricean fading channel is first presented. Based on the expression, the effect of both channel aging and the Ricean factor on the power scaling law are studied. It is found that the transmit power of base station (BS) is scaled down by $1/{\sqrt{M}}$(where M is the number of the BS antennas) when the Ricean factor K is equal to zero (i.e., time varying Rayleigh fading channel), indicating that aged CSI does not affect the power scaling law. However, the transmit power of the BS is scaled down by 1/M for the time varying Ricean fading channel (where $K{\neq}0$) indicating that the Ricean factor affects the power scaling law and sum rate, and channel aging only leads to a reduction of the sum rate. Second, the EE of the system is analyzed based on the general power consumption model. Both the theoretical analysis and the simulations show that the channel aging could degrade the sum rate and the EE of the system, and it does not affect the power scaling law.

The Clinical Effect with the Use of Gel Anesthesia within Gingival Sulcus during Scaling

  • Park, Seong-Ok;Im, Ae-Jung;Ahn, Yong-Soon;Jung, Im-Hee;Lim, Do-Seon
    • 치위생과학회지
    • /
    • 제18권5호
    • /
    • pp.319-326
    • /
    • 2018
  • Although scaling is the primary method for improving oral health, it is also associated with dental fear. The objective of this study was to empirically verify whether the use of gel anesthetic within the gingival sulcus during scaling relieves pain and improves other factors. A total of 128 patients scheduled to undergo scaling at a dental clinic of a general hospital located in the Gyeonggi Province, between July 2014 and July 2015, were enrolled in the study. The participants underwent scaling following the application of 20% benzocaine gel or placebo gel anesthetic within the gingival sulcus, and the data was collected using a questionnaire. There was a significant difference in the severity of pain, participant satisfaction, perceived sensitivity, overall discomfort, and fear of scaling between the two groups. The two groups were compared in terms of perceived need for gel anesthesia, willingness to pay for anesthesia costs, and willingness to receive scaling in the future. There were significant differences in all the three parameters depending on whether gel anesthesia was used or not. There were significant differences between the two groups in perceived sensitivity immediately after scaling and one day after scaling, with no difference seen one week after scaling. With regards to overall discomfort over time, there were significant differences between the two groups immediately after scaling. Based on these findings, we expect that application of gel anesthetic within the gingival sulcus during scaling will reduce pain, perceived sensitivity, overall discomfort, and fear of scaling with increased satisfaction.