• Title/Summary/Keyword: Time-mean Flow

Search Result 758, Processing Time 0.026 seconds

A study on the measurement of Blood flow-turbulence (혈류의 Flow-Turbulence 측정에 관한 연구)

  • Ko, Yeon-Soon;Kang, Chung-Shin;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.294-296
    • /
    • 1988
  • The tomographic imaging that employs ultrasonic echos has achieved outstanding advances in recent years, and today, ultrasonic diagnostic equipment has become the tool that is absolutely indispensible for clinical operations. Meanwhile, the feasility of measuring blood flow in the heart and vessels by the use of Doppler effect in ultrasonic waves is a well known fact. With respect to the method of blood flow measurment, there are two kinds which employ continous wave and pulse wave doppler system. In this paper, we describe the measurment of Blood flow-turbulence using general purpose Digital Signal Processing Board which had been implemented for the purpose of real-time spectrum analyser. Blood flow-turbulence means the blood-flow behavior. And it's value proportional to the spectrum variance. Therefore mean frequency of blood signal and variance provide useful diagnostic information. We have applied to the major arteries and vein, obtained the information about the time dependent blood-flow behavior.

  • PDF

PIV Measurement and Flow Characteristics of Internal Flow Field within Ginseng Washing Machine (인삼세척기 내부유동장의 PIV계측 및 유동특성)

  • Na, Eun-Su;Song, Chi-Seong
    • 연구논문집
    • /
    • s.30
    • /
    • pp.59-65
    • /
    • 2000
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry)to high_speed flow characteristics within Ginseng washing machine. Three different kinds of flow rate(15,20,27 $\ell$/min)are selected as experimental conditions. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. Instantaneous velocity distribution, time-mean velocity distribution and velocity profiles are represented quantitatively at the full-scale region for the deeper understanding of the flow characteristics in Ginseng washing machine.

  • PDF

Job sequencing decision in flow shop using revised Multi-Criteria Decision Making Method (수정된 다기준 의사결정을 이용한 흐름방식에서의 작업순서 결정)

  • 안춘수;강태건;정상윤;홍성일
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.44
    • /
    • pp.135-151
    • /
    • 1997
  • In this paper, we propose a simple and relatively efficient heuristic method to determine job sequencing in the flow-shop considering multiple criteria such as processing time, due date and cost. The proposed method is applicable to the flow- shop where the jobs are released simultaneously and their processing sequence is predetermined and not changed until the whole jobs are processed. To develop this method, we mixed and modified some well-known multi-attribute decision heuristics such as the simple linear weighting scheme, the lexicographic rule and the 'elimination by aspect' rule. Some computer simulations were conducted to test the efficiency of the proposed method and it has been compared with the SWPT (Shortest Working Processing Time) rule and EDD (Earliest Due Date) rule. The results show that our method is as effective as the traditional ones in terms of mean flow time, tardiness, makespan, cycle time, machine utilization, etc., and proved to be much simpler and more flexible to be used in real situations.

  • PDF

Flow Holding Time based Advanced Hybrid QoS Routing Link State Update in QoS Routing

  • Cho, Kang Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.4
    • /
    • pp.17-24
    • /
    • 2016
  • In this paper, we propose a AH LSU(Advanced Hybrid QoS Routing Link State Update) Algorithm that improves the performance of Hybrid LSU(Hybrid QoS Link State State Update) Algorithm with statistical information of flow holding time in network. AH LSU algorithm has had both advantages of LSU message control in periodic QoS routing LSU algorithm and QoS routing performance in adaptive LSU algorithm. It has the mechanism that calculate LSU message transmission priority using the flow of statistical request bandwidth and available bandwidth and include MLMR(Meaningless LSU Message Removal) mechanism. MLMR mechanism can remove the meaningless LSU message generating repeatedly in short time. We have evaluated the performance of the MLMR mechanism, the proposed algorithm and the existing algorithms on MCI simulation network. We use the performance metric as the QoS routing blocking rate and the mean update rate per link, it thus appears that we have verified the performance of this algorithm.

Studies on the Paper Electrophoresis, I On the Mobility of Egg Albumin(Ovalbumin) (페이퍼 에레크트로포레시스에 關한 硏究 (제1보) 계란단백의 移動度에 關하여)

  • Chang, Sei-Hun;Kim, Si-Joong
    • Journal of the Korean Chemical Society
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 1957
  • The mobilities and the electrophoretic phenomena of human serum albumin, and of horse serum albumin, etc., on paper were reported, but there is no information about the mobility and the electrophoretic phenomena of ovalbumin. In this study they are determined and considered at various time durations. The mean value of this mobility is compared with the value determined by the electrophoresis in solution. Also, the mobilities of the electroendosmotic flow, which affect on the mobility seriously, are determined at various time durations. Apparatus and method used, are a closed system type and a method with electrode vessels. It is concluded that: 1) The mobilities of ovalbumin have the nearly constant mobilities at six and eight hours of time durations, but it decreases at ten hours of long time duration. Their mean value is (0.243 ${\pm}$ 0.003)cm./hr./v./cm. toward anode at pH 8.0. 2) Under these experimental conditions, ovalbumin cannot be separated into three fractions (A1, A2, A3) on paper. 3) Most of the factors, which affect on the mobility, are fixed by the initial experimental conditions, but the electroendosmotic flow due to the characteristic capillarity of paper is measured. Then, the mean value of its mobilities shows the good constancy, and the value is (0.073 ${\pm}$ 0.0003)cm/hr./v./cm. toward cathode at pH 8.0. 4) By the above facts, if the same paper and the same experimental conditions are chosen, it may be preferred to determine the mobility of the electroendosmotic flow once time, even when many observations are required.

  • PDF

The Effectiveness of Order Release Strategies considering Production Plan and Dispatching Rules (생산계획 및 우선순위규칙에 따른 Order Release 정책의 유효성에 관한 연구)

  • 최병대;이기창;박찬권;박진우
    • Journal of the Korea Society for Simulation
    • /
    • v.8 no.4
    • /
    • pp.73-87
    • /
    • 1999
  • Order Review/Release (ORR) System is the linkage between planning system and actual production. Reduction of the waiting time on the machines, work in process and lead time variation may be achieved by adopting ORR strategies. But researchers on the ORR do not agree on the effectiveness of ORR. Some say that the overall system flow time may be increased if ORR is adopted, but others say that ORR can reduce work in process, flow time and variation of flow time. The objective of this research is to clarify under what environments order release strategy is effective. Simulation study was conducted in a hypothetical job shop. The experimental results show that dispatching rule is much more important than ORR is in controlling the shop floor. But the results indicate that ORR can reduce mean shop flow time, average work in process and variation of shop flow time under such environments where utilization level is high and planned order is weekly released to the order pool. And the results also show that the effect of plan smoothing on the ORR is insignificant, which is inconsistent with the results of the previous researches.

  • PDF

Residence Time Distributions of Liquid pbase Flow and Mass Transfers in the Trickle Bed Reactor (점적상 반응기에서 액상흐름의 체류시간 분포 및 물질전달)

  • Kim, Ki-Chang
    • Journal of Industrial Technology
    • /
    • v.6
    • /
    • pp.19-31
    • /
    • 1986
  • The residence time distribution of liquid flow in a 4.0cm diameter column packed with porous $Al_2O_3$ spheres of 0.37cm diameter were measured with pulse injections of a tracer under cocurrent trickling flow conditions. The mean residence time of liquid flow and liquid hold-up calculated by the transient curve of tracer were unaffected by gas flow rates under experimental ranges of liquid flow rates from 2.4 to $4.5(kg/m^2\;sec)$ and gas flow rates from 0 to $0.13(kg/m^2\;sec)$. The axial dispersion coefficient of liquid stream and apparent diffusivity of tracer in a micropore of solid particle were estimated from the response curve of tracer. The calculated Peclet No. were increased in ranges of 68-to 82 with a increasing of liquid mass velocity, and the external effective contacting efficiency between liquid and solid which can be expressed. by $(D_i)_{app}/D_i$ varied in ranges of 0.54 to 0.68 depending on the liquid flow rates. The gas to liquid(water) volumetric mass transfer coefficient were determined from desorption experiments with oxygen at $25^{\circ}C$ and 1 atm. The measured mass transfer coefficients were increased with liquid flow rates and the effect of gas flow rates on the mass transfer coefficient was insignificant.

  • PDF

Measurement of Flow Field in a Ginseng Cleaner Model Using PIV (PIV에 의한 인삼세척기 모델 내부의 유동계측)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.139-145
    • /
    • 2001
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry) to high_speed flow characteristics within ginseng cleaner model. Three different kinds of flow rate(15. 20, 27l/min) are selected as experimental condition. Optimized cross correlation identification to obtain velocity distribution, time-mean velocity distribution, velocity, profile, kinetic energy and turbulence intensity are represented quantitatively for the deeped understanding of the flow characteristics in a ginseng cleaner model.

  • PDF

A Study on Flow Characteristics of a Ginseng Cleaner Using PIV (PIV에 의한 인삼세척기의 특성연구)

  • 송치성
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.140-145
    • /
    • 2000
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry) to high_speed flow characteristics within ginseng cleaner model. Three different kinds of flow rate(15.20 27ℓ/min) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. The instantaneous velocity distribution time0mean velocity distribution and velocity profile are represented quantitatively for the deeper understanding of the flow characteristics in a ginseng cleaner model.

  • PDF