• 제목/요약/키워드: Time-frequency domain reflectometry

검색결과 70건 처리시간 0.044초

Radio Frequency 회로 모듈 BGA 패키지 (Electrical Characterization of BGA interconnection for RF packaging)

  • 김동영;우상현;최순신;지용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(2)
    • /
    • pp.96-99
    • /
    • 2000
  • We presents a BGA(Ball Grid Array) package for RF circuit modules and extracted its electrical parameters. We constructed a BGA package of ITS(Intelligent Transportation System) RF module and examined electrical parameters with a HP5475A TDR(Time Domain Reflectometry) equipment and compared its electrical parasitic parameters with PCB RF circuits. With a BGA substrate of 3 $\times$ 3 input and output terminals, we have found that self capacitance of BGA solder ball is 68.6fF, self inductance 146pH, mutual capacitance 10.9fF and mutual inductance 16.9pH. S parameter measurement with a HP4396B Network Analyzer showed the resonance frequency of 1.55㎓ and the loss of 0.26dB. Thus, we may improve electrical performance when we use BGA package structures in the design of RF circuit modules.

  • PDF

실시간 스펙트럼 추정기에 기반한 시간-주파수 영역에서의 동축케이블 결함 검출 기법 (Time-Frequency Domain Reflectometry based on Real-Time Spectrum Estimation for Detection and Localization of a Fault on a Coaxial Cable)

  • 두승호;나원상;곽기석;윤태성;박진배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.300-301
    • /
    • 2007
  • 본 논문에서는 실시간 스펙트럼 추정기에 기반하여 시간-주파수 영역 반사파 계측 시스템에서의 동축케이블 결함을 검출하는 방법을 제안한다. 시간-주파수 영역 반사파 계측 시스템은 가우시안 포락선(Gaussian Envelop)모양의 첩 신호를 기준신호로 하여 도선에 반사파를 분석하는 기법으로써 타 방법에 비하여 높은 정확도를 자랑하는 것으로 알려져 있다. 하지만 결함 위치를 추정하기 위해 Wigner 시간 주파수 분포 함수를 이용하므로 계산량 증가에 따른 실시간 구현이 어렵다는 단점이 있었다. 이러한 단점을 극복하기 위하여 본 논문에서는 LMS 스펙트럼 추정기를 이용한 시간-주파수 영역 반사파 계측 시스템의 구현방법을 새롭게 제안한다. 제안된 기법은 실제 동축케이블에 대한 실험결과를 통하여 그 성능을 입증하도록 한다.

  • PDF

사양토에서의 용적수분 함량 측정을 위한 TDR 및 FDR 센서의 검증 (Verification of TDR and FDR Sensors for Volumetric Soil Water Content Measurement in Sandy Loam Soil)

  • 허승오;하상건;김정규
    • 한국토양비료학회지
    • /
    • 제42권2호
    • /
    • pp.110-116
    • /
    • 2009
  • 토양의 용적수분 함량을 현장에서 측정할 수 있어 토양 내 물 이동이나 관개관리에 효과적으로 이용할 수 있는 6종의 토양수분 센서에 대한 검정을 실시했다. TDR형태의 센서가 2종으로 토양단면측정용인 TRIME과 탐침형태인 Mini-TRASE이었으며, 4종은 FDR 형태의 센서로 토양단면 측정용인 EasyAG, EnviroSCAN, PR-1과 탐침형태의 WET-1 센서였다. 코어로 측정한 용적수분함량과 비교한 결과 TRIME은 1차 선형식의 관계에서 코어측정값과 약 2.4%의 오차를 나타냈고, Mini-TRASE는 코어 용적 수분함량과 약 1.4%의 오차를 나타냈으며, 이 오차는 실험에 사용했던 7종의 센서들 중에서 가장 작은 값이었다. EasyAG는 SF로 분석했을 때는 코어측정값과 약 2.6%의 오차를 나타냈고, 센서로 측정한 토양 수분 함량을 코어수분함량과 직접적으로 비교했을 때도 역시 약 2.6%의 오차를 나타냈다. EnviroSCAN은 SF로 분석했을 때는 코어측정값과 약 2.8%의 오차를 나타냈고, 센서로 측정한 토양수분 함량을 코어수분 함량과 직접적으로 비교했을 때는 2.6%의 오차를 나타냈다. WET-1은 센서로 측정한 값과 코어로 실측한 값 사이에 약 2.0%의 오차가 있음을 보여주고 있으며, 이것은 검정에 사용했던 FDR 센서들 중에서는 가장 작은 값이었다. PR-1은 측정시 access 튜브 내에서 방향을 조금씩 바꿀 때마다 측정값이 달리 나오는 경우가 많아 수분함량 측정횟수가 많지 않았으나 실측값과 약 4.7%의 오차를 보였다. 결론적으로 센서의 정확성을 검정하기 위해 사용된 6종의 센서 중 PR-1은 현장 측정에 문제가 있을 것으로 여겨진다.

유전율법을 이용한 다공질 매질의 공극률 및 유효공극률의 측정에 관한 연구 (Determination of porosity and effective porosity of saturated porous media using a permittivity method in the laboratory)

  • 김만일;니시가끼마코토
    • 지질공학
    • /
    • 제13권4호
    • /
    • pp.419-428
    • /
    • 2003
  • 지반을 대상으로 지하수의 이동 및 오염물질 침투에 대한 평가를 위해, 지반을 구성하고 있는 매질의 공극률과 유효공극률을 파악하는 것은 매우 중요하다. 이들은 물질 이동을 결정하는 중요한 물리적 파라메터이다. 본 연구에서는 새로운 유전율 시스템인 FOR-V (Frequency domain reflectometry with vector network analyzer)를 적용하여 표준사 (Standard sand)와 강모래 (River sand)에 대한 공극률 및 유효공극률을 측정하기 위한 실험적 연구를 실시하였다. 또한, 이들을 측정하기 위해, 다공질 매질에 대한 유전율상수의 특성을 고려한 유전율 믹싱모델 (dielectric FDR-V 시스템을 적용한 주입실험 (Injection test)과 주입물질의 농도를 측정하는 치환실험 (Replacement test)을 수행하였다. 두 종류의 실험 결과치를 비교한 결과, 측정된 유효공극률을 공극률과 비교해 보면, 약 85 - 92 %의 범위 내에 존재하는 것으로 측정되었다. 일반적인 흙의 유효공극률은 공극률에 대해 약 90 % 범위 내에 분포하고 있는 것으로 알려져 있으나, 본 연구에서는 다소 낮은 결과치를 보이고 있다. 이러한 현상은 시스템의 측정 프로브의 측정 범위가 직경 0.36 cm의 동축측정프로브 끝부분에서 이루어져 비교적 작기 때문에 제작된 흙 시료전 체적에 대한 유효공극률의 결과치이기 보다는 프로브가 위치한 지점에 대한 측정치로 판단된다. 이러한 측정 프로브의 특성을 고려해 볼 때, FDR-V 시스템은 연구자가 의도한 연구에 따라 특정 지점에 대한 지반의 정밀한 물리적 특성을 파악할 수 있을 것으로 사료된다.

고온 초전도 케이블 고장점 탐지를 위한 EMTP 시뮬레이션 및 분석 (EMTP Simulations and Analysis for Detection of Fault Location in High Temperature Superconducting Cables)

  • 방수식;장승진;이건석;권구영;이영호;황민제;손송호;박기준;신용준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.357-358
    • /
    • 2015
  • 본 논문에서는 고온 초전도 케이블 고장점 탐지를 위해 시간-주파수 반사파 계측법(Time-Frequency Domain Reflectometry)을 적용하여 EMTP 시뮬레이션을 수행하고, 고온 초전도 케이블에 적합한 가우시안 첩 포락선 선형 기준 신호를 제시하였다. 고온 초전도 케이블을 EMTP로 모델링하여 TFDR 기법을 통해 케이블의 종단점을 추정하고 기준 신호의 전파 속도를 계산하였다. EMTP를 활용하여 국부적 결함이 발생한 고온 초전도 케이블을 모델링하였고, 결함 발생 케이블의 고장점 탐지 시뮬레이션 결과를 확인하였다.

  • PDF

고주파수 전자기파를 이용한 압밀 포화토 물성치 측정을 위한 연구 (A study on measurement of physical parameters using electromagnetic wave of the compacted saturated soil)

  • 김만일;김형수;석희준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.354-361
    • /
    • 2005
  • Physical parameters such as porosity and effective porosity are important physical parameters that determine the transfer and movement of water and solutes in porous media. Various methods of determining these parameters have been developed, with varying degrees of accuracy and applicability. Most of the existing methods produce static results. They do not produce instantaneous and real time of porosity and effective porosity in a porous media. In this study, a new permittivity method called Frequency Domain Reflectometry with Vector analyzer (FDR-V) is proposed to determine the porosity and effective porosity of some sand samples in the laboratory. The advantage of the FDR-V method is that it instantaneously determines the temporal variation of dielectric constants of porous media. Then, the porosity and the effective porosity of porous media are computed using well established empirical equations. Results obtained from the FDR-V method compared favorably with results from other permittivity methods such as gravimetric, injection and replacement tests. The ratio of effective porosity to porosity was $85{\sim}92%$, when FDR-V was used. This value compared favourably with 90%, which has been usually quoted in previous studies. Considering the convenience and its applicability, the measurement system of FDR-V permittivity holds a great potential in porous media and contaminant transport studies.

  • PDF

위성 토양수분 데이터 및 COSMIC-ray 데이터 보정/검증을 위한 성균관대학교 내 FDR 센서 토양수분 측정 연구(SM-FC) 및 데이터 분석 (Construction and estimation of soil moisture site with FDR and COSMIC-ray (SM-FC) sensors for calibration/validation of satellite-based and COSMIC-ray soil moisture products in Sungkyunkwan university, South Korea)

  • 김형록;선우우연;김성균;최민하
    • 한국수자원학회논문집
    • /
    • 제49권2호
    • /
    • pp.133-144
    • /
    • 2016
  • 본 연구에서는 수원 성균관대학교 내 Frequency Domain Reflectometry (FDR) 토양수분 측정 장비 및 COSMIC-ray 중성자 측정 장비를 통한 토양수분 지점 관측 사이트를 확립하였다. 또한 양질의 토양수분 데이터 확보를 위해 연구지역 내 토질실험, 토질별 FDR 토양수분 데이터 및 COSMIC-ray 중성자 개수의 시계열 분석, 관측한 토양수분 데이터와 위성 기반 토양수분 데이터와의 비교분석을 실시하였다. 2014년도부터 6개 지점에서 표층으로부터 5 cm에서 40 cm까지 총 24개의 FDR 센서를 5~10 cm 깊이별로 설치하여 토양수분 데이터를 측정하였다. 해당 지점들의 토질 분석결과, Sand에서 Loamy Sand까지의 다양한 토질이 불균질한 층을 이루어 분포되어 있는 것으로 판단되었다. 측정된 토양수분 데이터는 강우 데이터와 높은 상관성을 보이며, 위성 산출 토양수분 데이터와의 비교에서도 상대적으로 높은 상관관계와 낮은 평균제곱근편차(Root mean square deviation, RMSD)값을 보여주었다. 2014년도 설치 지역 토양수분 데이터의 신뢰도가 확보됨에 따라 2015년도에는 10개의 FDR 토양수분 측정 장비 및 COSMIC-ray 중성자 측정 장비가 추가로 설치되어 성균관대학교의 Soil Moisture site with FDR and COSMIC-ray(SM-FC) 연구지역이 구축되었다. SM-FC에 설치된 COSMIC-ray 중성자 측정 장비의 최초 검증을 위해 2015년 8~11월의 COSMIC-ray 중성자 데이터 및 FDR 토양수분 데이터가 활용되었다. 중성자기반 토양수분 값과 전체 지점 FDR 토양수분 평균값을 비교한 결과 매우 높은 상관관계를 볼 수 있었다 (상관계수 0.95). 이러한 연구를 통해 성균관대학교 SM-FC는 향후 한반도 지역 위성 및 모델 토양수분 데이터를 검증하는 대표 연구지역이 될 것으로 기대된다.

산악 지형에서의 토양수분 관측소 구축을 위한 연구(1): Cosmic-ray 검증시스템 구축을 위한 토양수분량 대표성 분석 연구 (A Study for establishment of soil moisture station in mountain terrain (1): the representative analysis of soil moisture for construction of Cosmic-ray verification system)

  • 김기영;정성원;이연길
    • 한국수자원학회논문집
    • /
    • 제52권1호
    • /
    • pp.51-60
    • /
    • 2019
  • 본 연구에서는 Cosmic-ray 토양수분량 관측시스템 구축 시 필요한 검증 네트워크 설계 기법 개발에 목적을 두고 유전율식(dielectric constant) 장비인 Frequency Domain Reflectometry (FDR)와 연계하여 Cosmic-ray 검증시스템을 구축 운영하였다. Cosmic-ray 검증시스템 평가에 필요한 시범지역은 기존 계측 장비와의 연계성과 다양한 수문자료의 활용성을 고려하여 설마천 유역에 구축하였다. 시범지역은 Cosmic-ray 장비와 FDR 센서(10개소)로 구축하였으며 2018년 7월부터 현재까지 운영되고 있다. 본 연구에서는 검증시스템의 신뢰도를 높이기 위해 코어법(soil core sampling method)을 통해 산출한 용적수분함량(volumetric water content)을 유전율식 장비와 정기적으로 검증하였다. 연구기간 중 수행한 코어법과 FDR 센서를 검증한 결과, 두 자료의 통계량이 $bias=-0.03m^3/m^3$$RMSE=0.03m^3/m^3$의 유의한 값을 보였다. 또한 연구기간 동안 FDR 센서의 시계열 특성은 모든 강우에 정상적으로 반응하였다. 그러나 일부 지점에서는 낙엽 및 캐노피의 차단과 상부사면의 유출 등으로 인해 상이한 특성을 보였다. Cosmic-ray 영향원(influence line) 내 FDR 센서의 대표성 분석은 시간 안정성 해석법(temporal stability analysis, TSA)을 이용하여 토심별(10 cm, 20 cm, 30 cm, 40 cm)로 분석하였다. 10개소에 대한 토심별 토양수분량의 대표성을 TSA로 분석한 결과, 토심 10 cm에서는 FDR 5, 토심 20 cm에서는 FDR 8, 토심 30 cm에서는 FDR 2, 토심 40 cm에서는 FDR 1에서 가장 우수한 대표 특성을 보였다. 본 연구의 시범지역 운영 기간이 짧다는 한계는 있지만 지금까지의 분석 결과를 토대로 하여 볼 때, Cosmic-ray 관측시스템 구축 시에는 검증 장비로는 유전율식을 활용하고, Cosmic-ray 영향원 내 토양수분량의 대표성 분석은 TSA 방법으로 수행하는 것이 바람직할 것으로 판단된다.

XLPE 케이블에서 보이드 결함의 부분방전 특성과 위치추정 (Partial Discharge Characteristics and Localization of Void Defects in XLPE Cable)

  • 박서준;황성철;왕국명;길경석
    • 한국철도학회논문집
    • /
    • 제20권2호
    • /
    • pp.203-209
    • /
    • 2017
  • 전력공급의 안정성 및 신뢰도 향상을 위해 각종 전력설비의 예방진단에 관한 연구개발이 활발하다. 가스절연개폐장치와 변압기와 같은 단위 기기의 절연진단기술은 빠르게 발전하고 있으나, 전력케이블에 있어서는 단순히 결함의 유무와 부분방전을 측정할 뿐, 세부적 특성에 대해서는 거의 연구되고 있지 않다. 따라서 본 논문에서는 XLPE 케이블에서 보이드의 크기와 위치에 따른 부분방전 특성과 결함의 위치추정에 관한 연구를 수행하였다. 보이드의 크기 및 위치에 따른 4종의 결함계를 모의하였으며, 부분방전펄스는 주파수 대역 150kHz~30MHz의 고주파변류기로 검출하였다. 실험결과, 도체에 인접한 결함일수록 방전전하량이 크고, 정극성에 비해 부극성의 방전펄스 수가 약 20% 많게 나타났다. 또한 TDR 방법으로 결함위치를 산출하였으며, 50m 케이블에서 1m 이내로 결함의 위치를 추정할 수 있었다.

코이어 배지 수경재배에서 관수효율 향상을 위한 급액 제어 (Irrigation Control for Improving Irrigation Efficiency in Coir Substrate Hydroponic System)

  • 유형주;최은영;이용범
    • 생물환경조절학회지
    • /
    • 제24권3호
    • /
    • pp.153-160
    • /
    • 2015
  • 본 연구는 환경오염과 양수분 손실을 주는 비순환식 수경재배에 FDR센서를 이용한 자동관수시스템을 적용할 때 관수효율을 높이기 위한 최적의 최소대기시간을 설정하고자 수행되었다. 실험은 가을과 겨울철에 봄과 여름철에 두 번 수행하였고 가을과 겨울철에는 3분 급액과 최소대기시간을 5분으로 한 3R5F 처리구, 3분 급액과 최소대기시간을 10분으로 한 3R10F 처리구, 5분 급액과 최소대기시간을 15분으로 한 5R15F 처리구를 설정하여 실험하였고 봄과 여름철에는 3분 급액과 최소대기시간을 5분으로 한 3R5F 처리구, 3분 급액과 최소 대기시간을 10분으로 한 3R10F 처리구를 설정하여 실험하였다. 3분 급액은 주당 60mL, 5분 급액은 주당 80mL가 공급되었다. 가을과 겨울철 재배에서 정식 후 62일 까지 주당 급액량은 3R5F (858mL) > 5R15F (409mL) > 3R10F (306mL) 처리 순으로 나타났고 배액률은 3R5F (44%) > 5R15F (23%) > 3R10F (14%) 순으로 나타났다. 정식 후 62일부터 102일 까지는 일일 주당 급액량이 5R15F (888mL)> 3R5F (695mL)> 3R10F (524mL) 순으로 나타났고 이 시기에 배액률은 5R15F에서 가장 높았다. 봄과 여름재배에서는 일일 주당 급액량과 배액율이 3R5F 처리구에서 3R10F 처리구보다 높았다. 두 재배 모두에서 수분이용효율 (WUE)은 3R10F 처리에서 높았다. 따라서 FDR 센서를 활용한 자동화 관수 시스템에서 관수효율을 높이기 위한 최소대기시간은 10분으로 고찰된다.