• Title/Summary/Keyword: Time-frequency domain reflectometry

Search Result 70, Processing Time 0.029 seconds

Electrical Characterization of BGA interconnection for RF packaging (Radio Frequency 회로 모듈 BGA 패키지)

  • Kim, Dong-Young;Woo, Sang-Hyun;Choi, Soon-Shin;Jee, Yong
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.96-99
    • /
    • 2000
  • We presents a BGA(Ball Grid Array) package for RF circuit modules and extracted its electrical parameters. We constructed a BGA package of ITS(Intelligent Transportation System) RF module and examined electrical parameters with a HP5475A TDR(Time Domain Reflectometry) equipment and compared its electrical parasitic parameters with PCB RF circuits. With a BGA substrate of 3 $\times$ 3 input and output terminals, we have found that self capacitance of BGA solder ball is 68.6fF, self inductance 146pH, mutual capacitance 10.9fF and mutual inductance 16.9pH. S parameter measurement with a HP4396B Network Analyzer showed the resonance frequency of 1.55㎓ and the loss of 0.26dB. Thus, we may improve electrical performance when we use BGA package structures in the design of RF circuit modules.

  • PDF

Time-Frequency Domain Reflectometry based on Real-Time Spectrum Estimation for Detection and Localization of a Fault on a Coaxial Cable (실시간 스펙트럼 추정기에 기반한 시간-주파수 영역에서의 동축케이블 결함 검출 기법)

  • Doo, Seung-Ho;Ra, Won-Sang;Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.300-301
    • /
    • 2007
  • 본 논문에서는 실시간 스펙트럼 추정기에 기반하여 시간-주파수 영역 반사파 계측 시스템에서의 동축케이블 결함을 검출하는 방법을 제안한다. 시간-주파수 영역 반사파 계측 시스템은 가우시안 포락선(Gaussian Envelop)모양의 첩 신호를 기준신호로 하여 도선에 반사파를 분석하는 기법으로써 타 방법에 비하여 높은 정확도를 자랑하는 것으로 알려져 있다. 하지만 결함 위치를 추정하기 위해 Wigner 시간 주파수 분포 함수를 이용하므로 계산량 증가에 따른 실시간 구현이 어렵다는 단점이 있었다. 이러한 단점을 극복하기 위하여 본 논문에서는 LMS 스펙트럼 추정기를 이용한 시간-주파수 영역 반사파 계측 시스템의 구현방법을 새롭게 제안한다. 제안된 기법은 실제 동축케이블에 대한 실험결과를 통하여 그 성능을 입증하도록 한다.

  • PDF

Verification of TDR and FDR Sensors for Volumetric Soil Water Content Measurement in Sandy Loam Soil (사양토에서의 용적수분 함량 측정을 위한 TDR 및 FDR 센서의 검증)

  • Hur, Seung-Oh;Ha, Sang-Keun;Kim, Jeong-Gyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.2
    • /
    • pp.110-116
    • /
    • 2009
  • This study was to verify and calibrate seven kinds of soil water sensors for volumetric soil water content(VSWC) measurement under field. Types of sensors were TDR (Time Domain Reflectometry) and FDR(Frequency Domain Reflectometry). Two kinds of TDR were TRIME(profile type), and Mini-TRASE(rod type). Five kinds of FDR were EasyAG, EnviroSCAN, PR-1(profile type), and WET-1(rod type). VSWC by TRIME and Mini-TRASE compared with VSWC by soil core showed the standard error of about 2.4%, and 1.4% which is the smallest value among all the sensors used in the experiment, respectively. The errors of EasyAG and EnviroSCAN analyzed with scaled frequency(SF) were about 2.6%, and 2.8% and those by 1 versus 1 correspondence were about 2.6%, and 2.6%, respectively. WET-1 showed about 2.0% of error, which is the smallest value among errors by FDR sensors. PR-1 with the error of about 4.7% should be hard for application in field. Therefore, users on soil water sensors have to take into consideration the errors of sensors revealed after the calibration for the correct measurement of VSWC in field. The rest except for PR-1 among the sensors could be used for VSWC measurement with 1.4~2.6% error.

Determination of porosity and effective porosity of saturated porous media using a permittivity method in the laboratory (유전율법을 이용한 다공질 매질의 공극률 및 유효공극률의 측정에 관한 연구)

  • 김만일;니시가끼마코토
    • The Journal of Engineering Geology
    • /
    • v.13 no.4
    • /
    • pp.419-428
    • /
    • 2003
  • In order to evaluate groundwater movement and the infiltration of contaminants, such as petroleum products, the determination of porosity and effective porosity is very important. Porosity and effective porosity are important physical parameters that determine the transfer and movement of water and solutes in porous media. Various methods of determining these parameters have been developed, with varying degrees of accuracy and applicability. Most of the existing methods produce static results. They do not produce instantaneous and real time of porosity and effective porosity in a porous media. In this study, we used a new permittivity method called Frequency Domain Reflectometry with Vector analyzer (FDR-V) to determine the porosity and effective porosity of some sand samples in the laboratory. The advantage of the FDR-V method is that it instantaneously determines the temporal variation of dielectric constants of porous media. Then, the porosity and the effective porosity of porous media are computed using well established empirical equations. Results obtained from the FDR-V method compared favorably with results from other permittivity methods such as gravimetric, injection and replacement tests. The ratio of effective porosity to porosity was 85 - 92 %, when FDR-V was used. This value compared favourably with 90 %, which has been usually quoted in previous studies. Considering the convenience and its applicability, the EDR-V permittivity holds a great potential in porous media and contaminant transport studies.

EMTP Simulations and Analysis for Detection of Fault Location in High Temperature Superconducting Cables (고온 초전도 케이블 고장점 탐지를 위한 EMTP 시뮬레이션 및 분석)

  • Bang, Su Sik;Jang, Seung-Jin;Lee, Geon Seok;Kwon, Gu-Young;Lee, Yeong Ho;Hwang, Min-Jae;Sohn, Song-ho;Park, Kijun;Shin, Yong-June
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.357-358
    • /
    • 2015
  • 본 논문에서는 고온 초전도 케이블 고장점 탐지를 위해 시간-주파수 반사파 계측법(Time-Frequency Domain Reflectometry)을 적용하여 EMTP 시뮬레이션을 수행하고, 고온 초전도 케이블에 적합한 가우시안 첩 포락선 선형 기준 신호를 제시하였다. 고온 초전도 케이블을 EMTP로 모델링하여 TFDR 기법을 통해 케이블의 종단점을 추정하고 기준 신호의 전파 속도를 계산하였다. EMTP를 활용하여 국부적 결함이 발생한 고온 초전도 케이블을 모델링하였고, 결함 발생 케이블의 고장점 탐지 시뮬레이션 결과를 확인하였다.

  • PDF

A study on measurement of physical parameters using electromagnetic wave of the compacted saturated soil (고주파수 전자기파를 이용한 압밀 포화토 물성치 측정을 위한 연구)

  • Kim, Man-Il;Kim, Hyoung-Soo;Suk, Hee-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.354-361
    • /
    • 2005
  • Physical parameters such as porosity and effective porosity are important physical parameters that determine the transfer and movement of water and solutes in porous media. Various methods of determining these parameters have been developed, with varying degrees of accuracy and applicability. Most of the existing methods produce static results. They do not produce instantaneous and real time of porosity and effective porosity in a porous media. In this study, a new permittivity method called Frequency Domain Reflectometry with Vector analyzer (FDR-V) is proposed to determine the porosity and effective porosity of some sand samples in the laboratory. The advantage of the FDR-V method is that it instantaneously determines the temporal variation of dielectric constants of porous media. Then, the porosity and the effective porosity of porous media are computed using well established empirical equations. Results obtained from the FDR-V method compared favorably with results from other permittivity methods such as gravimetric, injection and replacement tests. The ratio of effective porosity to porosity was $85{\sim}92%$, when FDR-V was used. This value compared favourably with 90%, which has been usually quoted in previous studies. Considering the convenience and its applicability, the measurement system of FDR-V permittivity holds a great potential in porous media and contaminant transport studies.

  • PDF

Construction and estimation of soil moisture site with FDR and COSMIC-ray (SM-FC) sensors for calibration/validation of satellite-based and COSMIC-ray soil moisture products in Sungkyunkwan university, South Korea (위성 토양수분 데이터 및 COSMIC-ray 데이터 보정/검증을 위한 성균관대학교 내 FDR 센서 토양수분 측정 연구(SM-FC) 및 데이터 분석)

  • Kim, Hyunglok;Sunwoo, Wooyeon;Kim, Seongkyun;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.2
    • /
    • pp.133-144
    • /
    • 2016
  • In this study, Frequency Domain Reflectometry (FDR) and COSMIC-ray soil moisture (SM) stations were installed at Sungkyunkwan University in Suwon, South Korea. To provide reliable information about SM, soil property test, time series analysis of measured soil moisture, and comparison of measured SM with satellite-based SM product are conducted. In 2014, six FDR stations were set up for obtaining SM. Each of the stations had four FDR sensors with soil depth from 5 cm to 40 cm at 5~10 cm different intervals. The result showed that study region had heterogeneous soil layer properties such as sand and loamy sand. The measured SM data showed strong coupling with precipitation. Furthermore, they had a high correlation coefficient and a low root mean square deviation (RMSD) as compared to the satellite-based SM products. After verifying the accuracy of the data in 2014, four FDR stations and one COSMIC-ray station were additionally installed to establish the Soil Moisture site with FDR and COSMIC-ray, called SM-FC. COSMIC-ray-based SM had a high correlation coefficient of 0.95 compared with mean SM of FDR stations. From these results, the SM-FC will give a valuable insight for researchers into investigate satellite- and model-based SM validation study in South Korea.

A Study for establishment of soil moisture station in mountain terrain (1): the representative analysis of soil moisture for construction of Cosmic-ray verification system (산악 지형에서의 토양수분 관측소 구축을 위한 연구(1): Cosmic-ray 검증시스템 구축을 위한 토양수분량 대표성 분석 연구)

  • Kim, Kiyoung;Jung, Sungwon;Lee, Yeongil
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.1
    • /
    • pp.51-60
    • /
    • 2019
  • The major purpose of this study is to construct an in-situ soil moisture verification network employing Frequency Domain Reflectometry (FDR) sensors for Cosmic-ray soil moisture observation system operation as well as long-term field-scale soil moisture monitoring. The test bed of Cosmic-ray and FDR verification network system was established at the Sulma Catchment, in connection with the existing instrumentations for integrated data provision of various hydrologic variables. This test bed includes one Cosmic-ray Neutron Probe (CRNP) and ten FDR stations with four different measurement depths (10 cm, 20 cm, 30 cm, and 40 cm) at each station, and has been operating since July 2018. Furthermore, to assess the reliability of the in-situ verification network, the volumetric water content data measured by FDR sensors were compared to those calculated through the core sampling method. The evaluation results of FDR sensors- measured soil moisture against sampling method during the study period indicated a reasonable agreement, with average values of $bias=-0.03m^3/m^3$ and RMSE $0.03m^3/m^3$, revealing that this FDR network is adequate to provide long-term reliable field-scale soil moisture monitoring at Sulmacheon basin. In addition, soil moisture time series observed at all FDR stations during the study period generally respond well to the rainfall events; and at some locations, the characteristics of rainfall water intercepted by canopy were also identified. The Temporal Stability Analysis (TSA) was performed for all FDR stations located within the CRNP footprint at each measurement depth to determine the representative locations for field-average soil moisture at different soil profiles of the verification network. The TSA results showed that superior performances were obtained at FDR 5 for 10 cm depth, FDR 8 for 20 cm depth, FDR2 for 30 cm depth, and FDR1 for 40 cm depth, respectively; demonstrating that those aforementioned stations can be regarded as temporal stable locations to represent field mean soil moisture measurements at their corresponding measurement depths. Although the limit on study duration has been presented, the analysis results of this study can provide useful knowledge on soil moisture variability and stability at the test bed, as well as supporting the utilization of the Cosmic-ray observation system for long-term field-scale soil moisture monitoring.

Partial Discharge Characteristics and Localization of Void Defects in XLPE Cable (XLPE 케이블에서 보이드 결함의 부분방전 특성과 위치추정)

  • Park, Seo-Jun;Hwang, Seong-Cheol;Wang, Guoming;Kil, Gyung-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.203-209
    • /
    • 2017
  • Research on condition monitoring and diagnosis of power facilities has been conducted to improve the safety and reliability of electric power supply. Although insulation diagnostic techniques for unit equipment such as gas-insulated switchgears and transformers have been developed rapidly, studies on monitoring of cables have only included aspects such as whether defects exist and partial discharge (PD) detection; other characteristics and features have not been discussed. Therefore, this paper dealt with PD characteristics against void sizes and positions, and with defect localization in XLPE cable. Four types of defects with different sizes and positions were simulated and PD pulses were detected using a high frequency current transformer (HFCT) with a frequency range of 150kHz~30MHz. The results showed that the apparent charge increased when the defect was adjacent to the conductor; the pulse count in the negative half of the applied voltage was about 20% higher than that in the positive half. In addition, the defect location was calculated by time-domain reflectometry (TDR) method, it was revealed that the defect could be localized with an error of less than1m in a 50m cable.

Irrigation Control for Improving Irrigation Efficiency in Coir Substrate Hydroponic System (코이어 배지 수경재배에서 관수효율 향상을 위한 급액 제어)

  • Yoo, Hyung-Joo;Choi, Eun-Young;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.153-160
    • /
    • 2015
  • The objectives of this study were to determine optimal length of off-time between irrigation cycles to improve irrigation efficiency using a frequency domain reflectometry (FDR) sensor-automated irrigation (FAI) system for tomato (Solanum lycopersicum L.) cultivation aimed at minimizing effluent from coir substrate hydroponics. For treatments, the 5-minute off-time length between 3-minute run-times (defined as 3R5F), 10-minute off-time length between 3-minute run-times (defined as 3R10F), or 15-minute off-time length between 5-minute run-times (defined as 5R15F) were set. During the 3-minute or 5-minute run-time, a 60mL or 80mL of nutrient solution was irrigated to each plant, respectively. Until 62 days after transplant (DAT) during the autumn to winter cultivation, daily irrigation volume was in the order of 3R5F (858mL) > 5R15F (409mL) > 3R10F (306mL) treatment, and daily drainage ratio was in the order of 3R5F (44%) > 5R15F (23%) > 3R10F (14%). Between 63 and 102 DAT, daily irrigated volume was in the order of 5R15F (888mL) > 3R5F (695mL) > 3R10F (524mL) with the highest drainage ratio, 19% (${\pm}2.6$), at the 5R15F treatment. During the spring to summer cultivation, daily irrigation volume and drainage ratio per plant was higher in the 3R5F treatment than that of the 3R10F treatment. For both cultivations, a higher water use efficiency (WUE) was observed under the 3R10F treatment. Integrated all the data suggest that the optimal off-time length is 10 minutes.